91.060.10 - Walls. Partitions. Facades
Walls. Partitions. Facades
Wande. Trennwande. Fassaden
Murs. Cloisons. Façades
Stene. Predelne stene. Fasade
General Information
This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...view more
- Standard90 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of lightweight partitions which have been tested in accordance with EN 1364-1, and classified according to EN 13501-2.
This document only applies to non-loadbearing lightweight partitions with a single steel framework, provided at both sides with a lining. The lightweight partition can be insulated or not with a mineral wool insulation.
This doc...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft12 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of lightweight partitions, which have been tested in accordance with EN 1364-1, and classified according to EN 13501-2.
This document only applies to non-loadbearing lightweight partitions with a single steel framework, provided with a lining on both sides of the steel framework. The lightweight partition can be insulated with a mineral wool insu...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft12 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies test methods for the determination of bearing capacity (ultimate limit state and serviceability limit state) of infill support which cannot be calculated in accordance with current codes or conventional calculations based upon the strength of the materials.
Mechanical performances of the infill support are already assessed while testing the glazed product or infill in regards to safety in use. Additional information with respect to mechanical performance of the ...view more
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of fire resistant glazed elements which have been tested in accordance with EN 1364-1, and classified according to EN 13501-2.
Extended application of fire resistant glazed elements shall be based on test evidence.
This standard only applies to vertically installed fire resistant glazed elements.
This standard does not apply to doorset...view more
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies test methods for the determination of the bearing capacity (ultimate limit state and serviceability limit state) of infill support which cannot be calculated in accordance with current codes or conventional calculations based upon the strength of the materials or to compare the calculation when necessary.
Three different types of infill (glass) supports are dealt in this standard:
- The cantilever infill (glass) supports, see Figure 1 (a);
- The cruciform infill (glass...view more
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides guidance and, where appropriate, defines procedures for variations of certain parameters and factors associated with the design of fire resistant glazed elements which have been tested in accordance with EN 1364-1:2015, and classified according to EN 13501-2.
Extended application of fire resistant glazed elements is based on test evidence.
This standard only applies to vertically installed fire resistant glazed elements.
This standard does not apply to door sets and ope...view more
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard defines rules for extended applications, provides guidance, and, where appropriate, defines procedures, for variations of certain parameters and factors associated with the design of internal and external non-loadbearing walls constructed of metal sandwich panels and that have been tested in accordance with EN 1364-1.
EN 15254-5 applies for self-supporting, double skin metal faced sandwich panels having an insulating core bonded to both facings as defined in EN 14509.
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of ISO 9705 specifies the test method to evaluate the reaction of wall and ceiling products to
fire when installed at the surface of a small room and exposed directly to a specified ignition source.
The test represents a fire scenario, which starts under well-ventilated conditions in a corner of a
specified room with a single open doorway.
Tests performed in accordance with the method specified in this part of ISO 9705 provide data
for the early stages of a fire from ignition up t...view more
- Standard45 pagesFrench language
sale 15% off- Standard42 pagesEnglish language
sale 15% off- Standard45 pagesFrench language
sale 15% off- Standard48 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard defines rules for extended applications, provides guidance, and, where appropriate, specifies procedures, for variations of certain parameters and factors associated with the design of internal non-load-bearing ceilings constructed of metal faced sandwich panels that have been tested in accordance with EN 1364-2.
This European Standard applies to self-supporting, double skin metal faced sandwich panels, which have an insulating core bonded to both facings as defined in EN...view more
- Standard23 pagesEnglish language
sale 10% off- e-Library read for1 day
This document defines rules for extended applications, provides guidance, and, where appropriate, defines procedures, for variations of certain parameters and factors associated with the design of internal and external non-loadbearing walls constructed of metal sandwich panels and that have been tested in accordance with EN 1364-1, which could generate a classification in accordance with EN 13501-2.
EN 15254-5 applies for self-supporting, double skin metal faced sandwich panels having an insula...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
Revision of EN ISO 12631:2012
This International Standard specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.
The calculation includes:
- different types of glazing, e.g. glass or plastic; single or multiple glazing; with or without low emissivity coating; with cavities filled with air or other gases;
- frames (of any material) with or without thermal breaks;
- different types of opaque ...view more
- Draft53 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard60 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 12631:2017 specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames.
The calculation includes:
- different types of glazing, e.g. glass or plastic; single or multiple glazing; with or without low emissivity coating; with cavities filled with air or other gases;
- frames (of any material) with or without thermal breaks;
- different types of opaque panels clad with metal, glass, ceramics or an...view more
- Draft53 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard60 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies definitions and requirements for non-structural facade sealants intended for sealing exterior wall joints, window and door perimeter joints in building construction, including the interior face.
NOTE Provisions on assessment and verification of constancy of performance - AVCP (i.e. Product type determination and Factory Production Control) and marking of these products are given in EN 15651-5.
This European Standard does not apply to non-structural sealants in ...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements for prefabricated lintels for maximum spans of 4,5 m and made from steel, autoclaved aerated concrete, manufactured stone, concrete, fired clay units, calcium silicate units, natural stone units, or a combination of these materials. Concrete and steel beams conforming to EN 1090-1, EN 12602 and EN 13225, as appropriate, are not covered by this standard.
Prefabricated lintels can be either complete lintels or the prefabricated part of a composite lin...view more
- Standard43 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements for wall ties, tension straps, hangers and brackets for interconnecting masonry and for connecting masonry to other parts of works and buildings including walls, floors, beams, and columns. Where anchors or fasteners are supplied or specified as part of an ancillary component, the requirements including performance requirements apply to the complete product.
This European Standard is not applicable to:
a) anchors and fasteners other than as part of...view more
- Standard60 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements for masonry bed joint reinforcement for structural use (see 5.2.1) and for non-structural use (see 5.2.2).
Where products are intended for use in cavity wall construction, this European Standard covers only the performance of the meshwork as reinforcement in bed joints and not its performance as wall ties across the cavity.
This European Standard is not applicable to:
a) products in the form of individual bars or rods;
b) products formed from...view more
- Standard28 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the test method to determine the bearing capacity connections between framing members of curtain walling for which the bearing capacity cannot be calculated in accordance with current codes or conventional calculations based upon the strength of the materials.
- Standard20 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard defines performance requirements of curtain walling (excluding ‘glass in building’ which is classified under EN 12600) under soft body impact load criteria specified herein and tested in accordance with EN 13049.
Its criteria is targeted to safety in use and integrity of curtain wall in the event of sudden impact forces on the curtain wall surfaces. Compliance with the performance requirement is determined by the laboratory test.
It applies to those areas of curtain walling which f...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard de¬scribes terminology used in documents, drawings, specifications etc., when referring to the detailed elements of curtain wall¬ing and provides a comprehensive, though not total, list of regu¬lar terms.
It does not set out to repeat those physical definitions properly included within individual curtain walling standards related to performance requirements and associated test methods.
- Standard25 pagesEnglish, French and German language
sale 10% off- e-Library read for1 day