This document is applicable to hinged and pivoted doors, doorsets and door assemblies with glass based leaves. Throughout this document the term “doorset” will be used to cover doors, doorsets and door assemblies. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
—   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
—   ambient temperature smoke control (Sa) and medium temperature smoke control (S200) classifications;
—   ability to close and durability of self-closing (C0 – C5);
—   glazed elements;
—   side, transom or over panels;
—   items of building hardware;
—   decorative and protective finishes;
—   intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals;
—   alternative supporting construction(s).
This document does not apply to horizontal doorsets and windows.

  • Standard
    120 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to all coverings, including but not limited to renderings, boards with and without air gaps and installed with various support systems. This document specifies a method for determining the ability of a covering to protect underlying materials against damage during a specified fire exposure.
The document is not used for the evaluation of fire resistance classifications (e.g. EI, EW, E) or reaction to fire classifications (specified in EN 13501-1).
The fire protection ability is influenced by the presence of combustible materials in the cavity behind the covering. The applicability of the results is limited according to the quantity and position of such combustible materials within that cavity.
NOTE   The amount of combustible materials permissible in the cavity is generally laid down in national regulations.

  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies performance, requirements, methods of test and marking requirements for the following equipment for use in automatic fire protection systems:
— wet alarm valves;
— retard devices;
— water motor alarms;
— dry pipe valves;
— accelerators;
— deluge valves;
— preaction valves;
— check valves.
Performance and test requirements for trim valves for alarm valves are not covered by this document.
The requirements for pressure reducing valves and fire pump relief valves are provided by ISO 6182-16 and ISO 6182-17.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    29 pages
    English language
    sale 15% off

This document specifies a test method for determining the fire resistance of various elements of construction when subjected to fire exposure conditions, represented with standardized time-temperature curves. The test data thus obtained will permit subsequent classification on the basis of the duration for which the performance of the tested elements under these conditions satisfies specified criteria.

  • Standard
    54 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    48 pages
    English language
    sale 15% off
  • Standard
    54 pages
    French language
    sale 15% off
  • Standard
    54 pages
    French language
    sale 15% off

This document specifies requirements for gaseous fire-extinguishing systems, with respect to FK-5-1-12 extinguishant. It includes details of physical properties, specification, usage and safety aspects.
This document is applicable only to systems operating at nominal pressures of 25 bar, 34,5 bar, 42 bar, 50 bar and 70 bar1 with nitrogen propellant. This does not preclude the use of other systems.
1   1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm².

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of the EN 1366 series specifies a method of test and criteria for the evaluation (including field of direct application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service or services. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts as well as combined penetration seals are excluded from this part of the EN 1366 series.
NOTE   EN 15882-5 [6] deals with penetration seals including ducts and dampers.
Supporting constructions are used in this part of the EN 1366 series to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice.
This part of the EN 1366 series is intended to be used in conjunction with EN 1363 1.
The purpose of a test described in this part of the EN 1366 series is to assess the integrity and insulation performance of the penetration seal, of the penetrating service or services and of the separating element in the surrounding area of the penetration seal.
No information can be implied by the test concerning the influence of the inclusion of such penetrations and penetration seals on the loadbearing capacity of the separating element.
It is assumed that in each case the lintel above a penetration seal in the wall is designed in hot and cold state in a way that it does not apply any additional vertical load on the penetration seal.
It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only noted in the test report in describing the general behaviour of test specimens during the test.
Tests in accordance with this part of the EN 1366 series are not intended to supply any information on the ability of the penetration seal to withstand stress caused by movements or displacements of the penetrating services.
The risk of spread of fire downwards caused by burning material, which drips e.g. through a pipe downwards to floors below, is at present excluded from this document.
Tests in accordance with this part of the EN 1366 series do not address any risks associated with leakage of dangerous liquids or gases caused by failure of pipes in case of fire.
Tests in accordance with this part of the EN 1366 series of pipe penetration seals for pipes of pneumatic dispatch systems, pressurized air systems, etc. simulate a situation where the systems are shut off in case of fire.
Explanatory notes to this test method are given in Annex H.
All values given without tolerances in this document are nominal ones unless otherwise specified.
All pipe diameters are outside diameters unless otherwise specified.

  • Corrigendum
    2 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the procedure for classification of the resistance to fire performance of construction products and building elements used as components of building service installations, using data from fire resistance tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this document.
Construction products or building elements for use in ventilation systems include (excluding smoke control system):
—   fire resisting ventilation ducts;
—   fire dampers.
Construction products or building elements for use in or as cables systems:
—   unprotected electric cables with intrinsic fire resistance;
—   fire protective systems for cable systems and associated components.
Relevant test methods which have been prepared for these construction products/building elements are listed in Clause 2.
NOTE   Cables associated with fire dampers are not generally covered by this document unless there is a local regulation that requires it.

  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies fire testing requirements for water mist systems used for fire protection of domestic and residential occupancies up to a maximum ceiling height of 5,5 m.
EXAMPLE   Examples for residential occupancies are family dwelling/house, bed and breakfast, apartment buildings, blocks of flats, care homes, small hotels or hostels, and residential areas in hotel bedrooms and guest corridors.
NOTE   Some countries might have a national annex with guidance on the maximum height of the building, minimum design area and any additional requirements.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames. Annex A gives details of assessing the smoke development, when required.
This method is applicable to all types of flooring, e.g. textile carpet, cork, wood, rubber and plastics coverings as well as coatings. Results obtained by this method reflect the reaction to fire performance of the flooring, including any substrate if used. Modifications of the backing, bonding to a substrate, underlay or other changes of the flooring can affect test results. It cannot be used alone to describe or appraise the fire hazard or fire risk of floorings under actual fire conditions.
Information on the precision of the test method is given in Annex B.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The requirements of this document set out the materials, construction, and performance of components intended for use in fixed foam fire fighting systems, and using foam concentrates conforming to EN 1568-1 to EN 1568-4. The components covered are: proportioners, sprayers, semi-subsurface hose units, branchpipes, low/medium expansion foam generators, high expansion foam generators, foam chambers, tanks and pressure vessels. Methods of test are given in Annex A to Annex K.
Requirements are also given for the provision of the characteristic data needed for correct application of components.
NOTE 1   Unless otherwise stated pressures are gauge pressures expressed in bar.
The requirements of this document do not cover, except where stated, the use of combinations of components to form part, or the whole, of a fire fighting system.
NOTE 2   Components conforming to this document are not necessarily compatible one with another.
Requirements for pumps, motors and the functioning of mechanical components (i.e. remote control turrets) are outside the scope of this document.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and gives recommendations for the design, installation, inspection and maintenance of all types of fixed land based water mist systems.
This document is intended to apply to water mist automatic nozzle systems and water mist deluge systems supplied by stand alone or pumped systems.
The document covers only applications and occupancies which are covered by the fire test protocols of the EN 14972 series.
Aspects of water mist associated with explosion protection and/or use within vehicles are not covered by this document.
This document does not cover all legislative requirements. In certain countries specific national regulations apply and take precedence over this document. Users of this document are advised to inform themselves of the applicability or non-applicability for this document by their national responsible authorities.

  • Standard
    122 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and describes the test methods for check valves for water mist firefighting systems.
Check valves allow the passage in the direction of flow and they prevent flow in the reverse direction.
This document is applicable to check valves installed in the pipework of water mist firefighting systems.

  • Standard
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for spray pattern sprinklers with a k-factor of at least K160, extended coverage (EC) sprinklers of at least K80, extended coverage storage sprinklers of at least K200 and control mode special application (CMSA) sprinklers. This document only covers sprinkler types up to K360.
This document does not apply to concealed, conventional, flat spray, flush and recessed sprinklers.

  • Standard
    80 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies safety and performance requirements for powered rescue tools manufactured after the date of publication.
This document is applicable to powered rescue tools which are intended for use by the firefighting and rescue services, principally for cutting, crushing, spreading, squeezing, pushing or pulling the structural parts of road vehicles, ships, trains, aircraft and building structures involved in accidents. This document is not applicable to hydraulic power packs covered by 2000/14/EC.
Powered rescue tools consist of tool(s) and the necessary system components (e.g. energy source, drive system and prime mover) and intended accessories, as defined in Clause 3.
This document deals with all significant hazards, hazardous situations or hazardous events relevant to the machinery, when it is used as intended and under conditions or misuse which are reasonably foreseeable by the manufacturer.
NOTE 1   The aim of powered rescue tools is to assist the firefighting and rescue services while extracting the casualties or to create a working space for paramedical services taking the local conditions into account.
This document does not include:
-   tools with pneumatic drive systems or pneumatic energy sources;
-   tools which are single acting (for example spring /gravity return jacks, powered struts, etc.).
It is not applicable to additional requirements for:
a)   operation in severe conditions (e.g. extreme environmental conditions such as temperatures outside the range –20 °C and +55 °C, corrosive environment, tropical environment, contaminating environments, strong magnetic fields, potentially explosive atmospheres, underwater use);
b)   the risk directly arising from the means provided for the portability, transportability, mobility and decommissioning of powered rescue tools during periods of their operation;
c)   generic tools such as, but not limited to, powered drills, angle grinders, saws, not solely intended for extrication purposes;
d)   tools intended to lift and/or hoist, not solely intended for extrication purposes.
NOTE 2   EN 13731:2007 deals with lifting bag systems for fire and rescue services.
NOTE 3   For the EU/EEA other Directives can be applicable to the equipment in the scope, for example the Electro Magnetic Compatibility Directive.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This test method specifies methods for determining the fire resistance of open-state cavity barriers and is to be used in conjunction with EN 1363-1.
This document is applicable to non-loadbearing vertically or horizontally oriented open-state cavity barriers, which are designed to close and provide fire separation in the event of fire.
Open-state cavity barriers in facades, where the fire exposure comes as a result of a breaking window and allowing a developed fire to come into contact with the façade, can be tested to the optional "flame" criteria.
This document is not applicable to cavity barriers containing penetration seals, which are covered by EN 1366-3.
This document is not applicable to closed cavity barriers, which are covered by EN 1366-4.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the common requirements for safety and the (minimum) common performance requirements of firefighting and rescue service vehicles as designated in EN 1846-1.
NOTE 1 Categories and mass classes of these vehicles are given in EN 1846-1.
NOTE 2 Vehicle means terrestrial vehicles that can also drive on rails and amphibious vehicles.
When drafting this document, it has been assumed that the finished standard automotive chassis (or
the chassis designed in accordance with the same principles) that is the basis for the firefighting or
rescue vehicle offers an acceptable safety level for its basic transport functions within the limits
specified by the manufacturer. Therefore, this document does not formulate requirements for this
chassis.
This document deals with all significant hazards, hazardous situations and events relevant to
firefighting and rescue service vehicles, when they are used as intended and under the conditions of
misuse which are reasonably foreseeable by the manufacturer.
Complementary specific requirements for aerial appliances are the subject of the following European
Standards:
— EN 1777: Hydraulic platforms (HPs) for firefighting and rescue services,
— EN 14043: Turntable ladders with combined movements,
— EN 14044: Turntable ladders with sequential movements.
NOTE 3 Additional regulations, not dealt with in this document, can apply in relation with the use of the
vehicles on public roads.
This document deals with firefighting and rescue vehicles intended for use in a temperature range
from –15 °C to +40 °C.
NOTE 4 In the case of utilization outside this temperature range, additional measures might be necessary as agreed between the manufacturer and the user. Such requirements are outside the scope of this document.
1.2   This document does not deal with the following types of firefighting or rescue vehicles or equipment:
-   vehicles designed exclusively for carrying personnel;
-   vehicles with a gross laden mass not exceeding 3 t;
-   boats;
-   aircraft;
-   railway vehicles;
-   ambulances (see EN 1789);
-   provisions for non-firefighting removable equipment driven by PTO;
-   airport vehicles in the scope of the recommendations of the International Civil Aviation Organization (ICAO).
1.3   This document deals with the technical requirements to minimize the hazards listed in Annex K which can arise during operational use, routine checking and maintenance of firefighting and rescue service vehicles when carried out in accordance with the specifications given by the manufacturer or his authorized representative.
It does not cover the hazards generated by:
-   non-permanently installed equipment i.e. portable equipment carried on the vehicle;
-   use in potentially explosive atmospheres;
-   commissioning and decommissioning;
-   electromagnetic compatibility.
Additional measures not dealt with in this document might be necessary for specific use (e.g. fire in natural environment, flooding, etc.).
1.4   This document is not applicable to machines that are manufactured before its date of publication as a European Standard.

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the design and installation of early suppression fast response (ESFR) and control mode specific application (CMSA) sprinklers in automatic sprinkler systems, in accordance with this standard and additionally the EN 12845 series of standards.
This document does not cover all legislative requirements.
NOTE   In certain countries, specific national regulations can apply. Attention is drawn to the applicability or non-applicability for this document as specified by national responsible authorities.

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies design, assembly, installation and commissioning requirements for pump sets for use in sprinkler systems conforming to EN 12845:2015+A1:2019.
Where applicable, this document can also be used for pump sets for other water based fixed firefighting systems.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and gives recommendations for the design, installation, testing, maintenance and safety of gas extinguishing systems in buildings, plants or other structures, and the characteristics of the various extinguishants and types of fire for which they are a suitable extinguishing medium.
This document describes total flooding systems primarily related to buildings, plants and other specific applications, utilizing electrically non-conducting gaseous fire extinguishants that do not leave a residue after discharge and for which there are sufficient data currently available to enable validation of performance and safety characteristics by an appropriate independent authority. This document is not applicable to explosion suppression.
This document is not intended to indicate approval of the extinguishants listed therein by the appropriate authorities, as other extinguishants may be equally acceptable. CO2 is not included as it is covered by its own European standard.
This document is applicable to the extinguishants listed in Table 1. This document is intended to be used in conjunction with the given parts of EN 15004 for fire extinguishing agents in Table 1.
Table 1 - Listed extinguishant
[...table not represented...]

  • Standard
    126 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of the EN 1366 series specifies a method of test and criteria for the evaluation (including field of direct application rules) of the ability of a penetration seal to maintain the fire resistance of a separating element at the position at which it has been penetrated by a service or services. Penetration seals used to seal gaps around chimneys, air ventilation systems, fire rated ventilation ducts, fire rated service ducts, shafts and smoke extraction ducts as well as combined penetration seals are excluded from this part of the EN 1366 series.
NOTE   EN 15882-5 [6] deals with penetration seals including ducts and dampers.
Supporting constructions are used in this part of the EN 1366 series to represent separating elements such as walls or floors. These simulate the interaction between the test specimen and the separating element into which the sealing system is to be installed in practice.
This part of the EN 1366 series is intended to be used in conjunction with EN 1363 1.
The purpose of a test described in this part of the EN 1366 series is to assess the integrity and insulation performance of the penetration seal, of the penetrating service or services and of the separating element in the surrounding area of the penetration seal.
No information can be implied by the test concerning the influence of the inclusion of such penetrations and penetration seals on the loadbearing capacity of the separating element.
It is assumed that in each case the lintel above a penetration seal in the wall is designed in hot and cold state in a way that it does not apply any additional vertical load on the penetration seal.
It is not the intention of this test to provide quantitative information on the rate of leakage of smoke and/or hot gases or on the transmission or generation of fumes. Such phenomena are only noted in the test report in describing the general behaviour of test specimens during the test.
Tests in accordance with this part of the EN 1366 series are not intended to supply any information on the ability of the penetration seal to withstand stress caused by movements or displacements of the penetrating services.
The risk of spread of fire downwards caused by burning material, which drips e.g. through a pipe downwards to floors below, is at present excluded from this document.
Tests in accordance with this part of the EN 1366 series do not address any risks associated with leakage of dangerous liquids or gases caused by failure of pipes in case of fire.
Tests in accordance with this part of the EN 1366 series of pipe penetration seals for pipes of pneumatic dispatch systems, pressurized air systems, etc. simulate a situation where the systems are shut off in case of fire.
Explanatory notes to this test method are given in Annex H.
All values given without tolerances in this document are nominal ones unless otherwise specified.
All pipe diameters are outside diameters unless otherwise specified.

  • Standard
    194 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation of the fire performance of water mist systems for non-stacking garages, fully enclosed garages and underground garages.
This document is applicable for horizontal, solid, flat ceilings with heights of 2 m and above.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers single and double leaf, hinged and pivoted, steel based doorsets except steel doorsets with metal framed door leaves covered by EN 15269-5. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples:
-   integrity (E), integrity and radiation (EW) or integrity and insulation (EI1 or EI2) classification;
-   door leaf;
-   side panels, transom panels, flush overpanels;
-   air transfer grilles (e.g. ventilation grilles/louvres);
-   components (e.g. frame/suspension system) fixed to the supporting construction (e.g. wall/ceiling);
-   glazing within the doorset (e.g. for door leaf, side, transom and flush overpanels);
-   items of building hardware;
-   decorative and protective finishes;
-   intumescent seals, strips and non-intumescent (smoke, draught or acoustic) seals;
-   alternative supporting construction(s).
This document does not cover horizontally installed doorsets (e.g. traps).
The effect on the classification ‘C’ for the doorsets following an extended application process is not addressed in this document.

  • Standard
    141 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes the minimum requirements applicable to the design, installation, functioning, test and maintenance of fixed automatic fire extinguishing systems for kitchen protection that covers the cooking appliances, the hood, the plenum and the air extract ducts. This document also provides requirements for the construction and components performance as applicable to specific types, designs, sizes and arrangements of pre-engineered kitchen fire-extinguishing systems.
This document does not cover household kitchens or industrial food production equipment.
The detailed test procedures for the plenum and air extract ducts are contained in CEN/TS 17749.
Closed plenum type ventilated ceilings designed similar to standard hoods are included in this document. Open plenum type ventilated ceilings are excluded and require an engineered solution for the plenum protection. Protection for appliances below open or closed plenum ventilated ceilings are included.

  • Standard
    36 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and gives recommendations for the design, installation, testing, maintenance and safety of fixed carbon dioxide firefighting systems in buildings, plants or other structures. It is not applicable to extinguishing systems on ships, in aircraft, on vehicles or on mobile fire appliances, or to below ground systems in the mining industry; nor does it apply to carbon dioxide pre-inerting systems.
Design of systems where unclosable opening(s) of the protected volume exceed a specified area and where the opening(s) can be subject to the effect of wind is not specified, although general guidance on the procedure to be followed in such cases is given (see 7.4.3.2).

  • Standard
    77 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a test method for determining the fire resistance of smoke extraction ducts. It is applicable only to smoke extraction ducts that pass through another fire compartment apart from the compartment from where smoke needs to be extracted in case of fire. It represents fire exposure of a fully developed fire.
This method of test is only applicable to fire resistant ventilation ducts (same construction) with the following classification according to EN 13501-3:
-   fire from inside and outside i ↔ o;
-   applicable to a pressure difference up to 500 Pa in fire conditions;
NOTE 1   It is assumed that the duct A test(s) in accordance with EN 1366-1 has been performed with an under-pressure of minimum 500 Pa.
-   with integrity (E) and insulation (I) criteria equal to or higher than the intended classification for the smoke extraction duct.
For the purposes of the test described in this document, the duct is referred to as duct C.
This test method has been designed to cover both vertical and horizontal smoke extraction ducts. A vertical system need not be evaluated to this method provided that:
-   both horizontal (ho) and vertical (ve) classification according to EN 13501-3 has been obtained for the ventilation duct;
-   it has been tested in a horizontal orientation to this method.
If the ventilation duct in practise is only used for vertical applications in smoke extraction systems, only vertical (ve) classification is obtained in accordance with EN 13501-3 and tested only in a vertical orientation to this test method.
This test method is suitable for ducts constructed from non-combustible materials (class A1 and A2-s1, d0 according to EN 13501-1).
NOTE 2   Reaction with components of the duct can affect the oxygen concentration inside the duct leading to inaccurate calculation of the leakage rate. If it is determined this has happened refer to Annex D.
This document applies to four sided rectangular and circular ducts only (with fire exposure on all sides). Ducts that utilize elements of construction for one, two or three sides are not covered. An alternative test method for one, two and three sided ducts will be developed separately.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies product characteristics and test methods of open nozzles and automatic nozzles for use in water mist systems.
NOTE   All pressure data in this document are given as gauge pressures in bar.

  • Standard
    37 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of EN 1366 specifies a test method for determining the fire resistance of smoke extraction ducts that are used for single compartment applications only. In such applications, the smoke extraction system is only intended to function up to flashover (typically 600 °C).
This method of test is only suitable for ducts constructed from non-combustible materials (class A1 and A2-s1, d0 according to EN 13501-1).
It is applicable only to four sided and circular ducts. One-, two- and three-sided ducts are not covered. This document is applicable only for the standard sizes or smaller as described.
This test method of part 9 is applicable only to smoke extraction ducts that do not pass into other fire compartments. For smoke extraction ducts that pass into other compartments, the method of test described in EN 1366-8 is used.
The smoke extraction duct is part of the smoke extraction system which also includes smoke control dampers and smoke extract fans.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies test methods for smoke control dampers to assess their performance under elevated temperature or fire conditions, as well as at ambient temperatures.
Smoke control damper tests are used to confirm that the furnace testing requirements of EN 12101-8 are met and EN 12101-8 is for consideration before carrying out these tests.
Smoke control dampers tested to this document are expected to be classified using EN 13501-4 and this document is expected to be considered before carrying out these tests.
NOTE   Some smoke control dampers to be tested might require testing following the information given in EN 1366-2 and this needs consideration before carrying out testing.
This document is expected to be read in conjunction with EN 12101-8, EN 13501-4, EN 1366-2 and EN 1363-1, the latter giving further details for fire resistance testing.
For installation details, the requirements for smoke extraction ducts are for consideration and these are defined in EN 1366-8 and EN 1366-9.

  • Standard
    99 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for the construction and performance of residential sprinklers as well as test methods for their type approval, which are operated by a change of state of an element or bursting of a glass bulb under the influence of heat and incorporating the following types of water seals:
—   conical metal spring with a PTFE gasket or coating;
—   metal cap or disc with PTFE gasket or coating;
—   copper gasket, with or without a PTFE coating.
Sprinklers in accordance with this document are only used in automatic sprinkler systems for domestic and residential applications as defined in EN 16925.

  • Standard
    61 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation of the fire fighting performance of water mist systems used for fire protection of commercial deep fat cooking fryers.
This document covers the area of the fryer and its close vicinity only and does not include surrounding areas beyond that the system is intended to cover.
This document includes protection of the cooking area, filters, exhaust hood, and duct against fires originating from the fryer.
This document covers only manually operated systems.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides specific requirements for gaseous fire-extinguishing systems with respect to the Halocarbon Blend 55 extinguishant. It includes details of physical properties, specification, usage and safety aspects. It also covers systems operating at nominal pressures of 25 bar, 35 bar, and 42 bar and 50 bar, superpressurized with nitrogen. This document does not preclude the use of other systems.
NOTE   1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for materials, construction and performance of components intended for use in powder firefighting systems complying with EN 12416-2:2001+A1:2007.
The components covered are as follows:
-   powder containers;
-   expellant gas container assemblies;
-   pressure regulators and gauges;
-   actuators;
-   main isolating valves and selector valves;
-   nozzles.
The components are suitable for powder firefighting systems for general use in buildings and other construction works. In areas with a risk of explosion, earthquake zones, extreme environmental conditions, e.g. marine, offshore, mining or aircraft additional considerations apply.
This document covers components for use in powder extinguishing systems complying with EN 12416-2:2001+A1:2007. It does not cover, for example, pipes and fittings which are covered by more general standards for which requirements and recommendations are given in EN 12416-2:2001+A1:2007. Nor does it cover fire detectors or electrical control and indicating equipment.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for earthquake protection of automatic sprinkler systems in accordance with EN 12845:2015+A1:2019.
This document applies only to locations in earthquake zones in accordance with EN 1998-1:2004, 3.2.1 and the Nationally Determined Parameters.
NOTE   The requirements in this document are based on the principle that certain peak ground acceleration values are considered as an earthquake which require special means. Attention is drawn to EN 1998-1:2004, where a peak ground acceleration above 0,08 g (0,78 m/s2) is considered an earthquake risk. Additional characteristics, NDP and/or NCI can exist in some countries as well as national annexes.
The principles defined in this document can be applicable to other water based fixed manual or automatic fire fighting systems, according to local requirements.

  • Standard
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation of the fire performance of water mist systems for lightly loaded non-storage and non-manufacturing occupancies with ordinary combustibles, such as offices, schools, hospitals and hotels.
This document is applicable to ceiling mounted and sidewall automatic nozzles to be used in restricted and/or unlimited areas.
This document is applicable for horizontal, solid, flat ceilings with heights of 2 m and above, up to the maximum tested ceiling height.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document defines terminology relating to fire safety as used in ISO and IEC International Standards.

  • Standard
    74 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes the method of specifying the design, installation and labelling criteria for chimney systems, construction of custom-built chimneys, the relining or converting of existing chimneys, connecting flue pipes and air supply pipes for room sealed combustion appliances as well as the use of chimney products. It also gives information on commissioning of an installed chimney.
This document applies to chimneys which are subject to the following limiting conditions:
-   the distance between the supports not to exceed 4 m;
-   the distance above the last structural attachment not to exceed 3 m;
-   the free-standing height above the uppermost structural support attachment for chimneys with rectangular cross section is not more than five times the smallest external dimension.
This document does not cover:
-   chimneys which serve a mixture of fan assisted or forced draught burners or natural draught appliances,
-   installations having a configuration of the type C2.
NOTE   Room sealed gas appliances are classified as type C according to EN 1749.
The methods in this part of this document are applicable to chimneys and connecting flue pipes for room sealed combustion appliances. The methods in Part 1 of this document are applicable to chimneys and connecting flue pipes for non-room sealed combustion appliances.

  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    108 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies fire testing requirements for water mist systems used for fire protection of commercial low hazard occupancies up to 5 m ceiling height.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document describes the method of specifying the design, installation and labelling criteria for system chimneys, construction of custom-built chimneys, the relining of existing chimneys and connecting flue pipes for non-room sealed combustion appliances as well as the use of chimney products. It also gives information on commissioning of an installed chimney.
This document applies to chimneys which are subject to the following limiting conditions:
-   the distance between the supports not to exceed 4 m;
-   the distance above the last structural attachment not to exceed 3 m;
-   the free-standing height above the uppermost structural support attachment for chimneys with rectangular cross section is not more than five times the smallest external dimension.
The methods in this part of this document are applicable to chimneys and connecting flue pipes for non-room sealed combustion appliances. The methods in Part 2 of this document are applicable to chimneys and connecting flue pipes for room sealed combustion appliances.

  • Standard
    96 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for single stage and multi-stage centrifugal pumps with mechanical seal or soft packing for use in automatic sprinkler systems and is for use with EN 12845 and EN 17451 .
This document is applicable for the following pumps, independent of installed orientation (vertical, horizontal or sloped according to the manufacturer indications):
-   end suction pumps (close coupled or long coupled) of the back pull-out type pump;
-   axial horizontal split case pumps;
-   ring section pumps including multistage single or multi outlet;
-   single or multistage inline pumps (pump with inlet and outlet in line);
-   submersible motor borehole pumps.
This document is also applicable to vertical turbine pumps.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation of the firefighting performance of water mist systems for false ceilings and false floors with heights between 300 mm and 800 mm.
This fire test protocol is applicable to pendent or upright automatic nozzles to be used in unlimited volume.
This document is applicable for horizontal, solid, flat ceilings.
It is not possible to apply these tests to other applications than the ones specified within this fire test protocol.

  • Standard
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies fire testing requirements for water mist systems used for fire protection of cable tunnels. The test protocol covers deluge water mist systems with open nozzles which are either activated with an automatic release system, e.g. fire detection system, or manually released.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the procedure for classification of construction products and building elements using data from fire resistance and/or smoke leakage/control tests and/or mechanical tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this document.
This document deals with:
a)   loadbearing elements without a fire separating function:
-   walls;
-   floors;
-   roofs;
-   beams;
-   columns;
-   balconies;
-   walkways;
-   stairs.
b)   loadbearing elements with a fire separating function, with or without glazing, services and fixtures:
-   walls;
-   floors;
-   roofs;
-   raised floors.
c)   products and systems for protecting elements or parts of the works:
-   ceilings with no independent fire resistance;
-   fire protective coatings, claddings and screens;
d)   non-loadbearing elements or parts of works, with or without glazing, services and fixtures:
-   partitions;
-   facades (curtain walls) and external walls;
-   ceilings with independent fire resistance;
-   raised floors;
-   fire resisting doorsets, shutter assemblies and openable windows and their closing devices;
-   smoke control doorsets and shutter assemblies and their closing devices;
-   conveyor systems and their closures;
-   penetration seals;
-   linear joint seals;
-   combined penetration seals;
-   service ducts and shafts;
-   air transfer grilles.
-   chimneys.
e)   wall and ceiling coverings with fire protection ability.
f)   lift landing doors which are tested according to EN 81-58 are excluded from this document. Lift landing doors which are tested in accordance with EN 1634-1 are classified in accordance with 7.5.5.
Relevant test methods which have been prepared for these construction products are listed in Clauses 2 and 7.

  • Standard
    86 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to single and double leaf, hinged and pivoted doorsets with timber-based leaves or timber framed glazed door leaves, covered by EN 15269-3 and / or EN 15269-20.
This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 1191 and or EN 12605:2000, as appropriate.
Subject to the completion of the appropriate self-closing test(s), the extended application can cover all or some of the following examples:
-   door leaf; pass doors;
-   glazed doorsets including vision panels and framed glazed doorsets;
-   side, transom and/or overpanels;
-   ventilation grilles and/or louvres;
-   wall or ceiling fixed elements (door frame/suspension system);
-   glazing for door leaf, side, transom and flush over panels;
-   items of building hardware;
-   decorative finishes;
-   intumescent, strips, smoke, draught or acoustic seals;
-   alternative supporting construction(s).

  • Standard
    78 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives guidelines for fulfilling the requirements contained in ISO 6183:2022, 6.4.1 and 7.4.1 and ISO 14520‑1:2023, 5.2.1 h) and 5.3 h), in respect to over- and under-pressurization venting and post-discharge extract.
It considers the design, selection and installation of vents to safeguard the structural integrity of enclosures protected by fixed gaseous extinguishing systems and the post-discharge venting provisions where used.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives the procedures for preparing standards and reports following the extended application (EXAP) process using the results of reaction to fire tests, fire resistance tests (including other performance characteristics e.g. smoke leakage/control and/or durability of self-closing), and external fire exposure to roof tests undertaken for fire classification of products and product families in accordance with the various parts of EN 13501. EXAP rules limit the number of tests required by implementing methods to determine the fire classification of a range of products (e.g. range of product, larger dimensions etc.) and EXAP rules form a standardized technical agreement on the parameter changes.
The fundamental concept of EXAP is the development of safe methods that provide extensions to the scope of the tested product while maintaining the required classification for the product. Test reports constitute the basis of an EXAP report.
This document makes reference to ‘extended application standards’ throughout; wherever this term is used it refers to either a standard prepared by CEN/TC 127 ‘Fire safety in buildings’ or the relevant product standard which includes information on extended application.
The European system currently permits extended application rules to be included in technical specifications. CEN Technical Committees and EOTA Working groups producing these rules are asked to seek the guidance of CEN/TC 127 to ensure that their rules comply with standards prepared by CEN/TC 127. In cases where extended application rules in harmonized EN product standards and ETAs do not comply with standards prepared by CEN/TC 127 the CEN BT are informed.
This document does not cover the incorporation of the product into the construction works that is justified by national rules.
Expert judgements (i.e. an opinion that is not considered/covered by an EXAP standard and only based on the experience of one individual) do not form part of this process.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers steel rolling shutters as covered by EN 15269 10 or EN 15269 20.
This document prescribes the methodology for extending the application of test results obtained from durability self-closing test(s) conducted in accordance with EN 16034.
Subject to the completion of the appropriate self-closing test or tests, the extended application could cover all or some of the following non-exhaustive list:
—   shutter curtain;
—   wall/ceiling fixed elements (frame/suspension system);
—   decorative finishes;
—   intumescent, smoke, draught or acoustic seals;
—   alternative supporting construction(s).

  • Standard
    73 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document is applicable to the following types of steel based doorsets: horizontally sliding single and double leaf doorsets, horizontally sliding single and double leaf telescopic doorsets, vertically sliding single leaf doorsets and vertically sliding single leaf telescopic doorsets as covered by EN 15269-7 or EN 15269-20.
This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 12605:2000 and/or EN 1191.
Subject to the completion of the appropriate durability of self-closing test or tests, the extended application can cover all or some of the following non-exhaustive list:
- door leaf (of the sliding doorset and its pass door);
- integrated pass doors;
- wall or ceiling fixed parts or items of the doorset, e.g. frame or suspension systems;
- ventilation grilles and/or louvres;
- glazing for door leaf;
- items of building hardware;
- decorative finishes;
- intumescent, smoke, draught or acoustic seals;
- alternative supporting construction(s).

  • Standard
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for early suppression and fast response (ESFR) sprinklers with a nominal discharge coefficient of 200 (pendent and upright), 240 (pendent and upright), 320 (pendent), 360 (pendent), 400 (pendent) and 480 (pendent) l/min/(bar)1/2.

  • Standard
    64 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides the reaction to fire classification procedure for electric cables.
NOTE   For the purpose of this document, the term "electric cables" covers all power, control and communication cables, including optical fibre cables.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document covers hinged or pivoted doorsets and door assemblies with wood-based door leaves and/or timber framed glazed door leaves and openable timber framed windows. Throughout this document, the term “doorset” will be used to cover doorsets, door assemblies and openable windows. It prescribes the rules for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1.
This document covers only doorsets with wood-based or metal frames. The door leaves are comprised of wood-based perimeter framing and wood-based structural facings.
Subject to the completion of the appropriate test or tests, the extended application can cover all or some of the following examples:
-   integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classifications;
-   glazing within the doorset, e.g. side and over panels, vision panels and framed glazed doorsets;
-   air transfer grilles (e.g. ventilation grilles/louvres);
-   side, transom or over panels;
-   items of building hardware;
-   decorative and protective finishes;
-   intumescent strips and non-intumescent seals (e.g. smoke, draught or acoustic seals);
-   alternative supporting construction(s).
This document covers only the effect on the fire resistance classifications E, EW, EI1 and EI2.
This document does not cover horizontal doorsets.