SIST EN 13830:2015+A1:2020
(Main)Curtain walling - Product standard
Curtain walling - Product standard
This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and could be replaced independently of it.
This standard applies to curtain walling kit ranging from a vertical position to ± 15° from the vertical. Any sloping parts should be contained within the curtain walling kit.
This standard is applicable to the whole of the curtain walling kits, including the fixings.
Curtain walling according to this standard is intended to be used as part of the building envelope.
This European Standard does not include:
— “Patent glazing” (glazed sloping roofs) kits;
— Roof glazing constructions;
— Façades made of precast concrete panels as part of the wall (see EN 14992).
NOTE 1 Precast concrete panels may be used in curtain walling kits as infill panels.
NOTE 2 Durability of structural sealed glazing infills is not covered by this standard.
Vorhangfassaden - Produktnorm
Diese Europäische Norm legt die Anforderungen an Vorhangfassadenbausätze fest, die zur Verwendung als Gebäude¬hülle vorgesehen sind, um Witterungsbeständigkeit, Nutzungssicherheit, Energieeinsparung und Wärmeschutz zu ermöglichen, und enthält Prüf / Bewertungs /Berechnungsverfahren und Konformitäts¬kriterien für die entsprechenden Leistungen.
Eine Vorhangfassade nach dieser Norm verfügt über ihre eigene mechanische Stabilität und Standsicherheit, sie trägt aber nicht zur Lastabtragung oder Stabilität des Hauptbaukörpers bei und kann unabhängig von diesem ersetzt werden.
Diese Norm gilt für Vorhangfassadenbausätze, die von einer vertikalen Konstruktion bis hin zu Konstruktionen mit einer Neigung von bis zu 15° von der Vertikalen reichen. Jegliche geneigten Teile sollten im Vorhangfassadenbausatz eingeschlossen sein.
Diese Norm gilt für den gesamten Vorhangfassadenbausatz einschließlich der Befestigungsmittel.
Vorhangfassaden nach dieser Norm sind zur Verwendung als Teil der Gebäudehülle vorgesehen.
Diese Europäische Norm gilt nicht für:
- Bausätze für Patentverglasungen (Schrägdachverglasungen);
- Konstruktionen von Dachverglasungen;
- Fassaden aus Fertigbetonelementen als Teil der Wand (siehe EN 14992).
ANMERKUNG 1 Fertigbetonelemente dürfe in Vorhangfassadenbausätzen als Ausfachungspaneele verwendet werden.
ANMERKUNG 2 Die Dauerhaftigkeit von Ausfachungen aus geklebten Glaskonstruktionen ist nicht Gegenstand dieser Norm
Façades rideaux - Norme de produit
La présente Norme européenne spécifie les exigences applicables au kit de façades-rideaux destiné à être utilisé comme une enveloppe du bâtiment afin de fournir une résistance aux sollicitations climatiques, une sécurité d'utilisation, de l'économie d'énergie et d’isolation thermique et fournit également des méthodes d’essai/d’évaluation/de calcul et des critères de conformité des performances associées.
Le kit de façade rideau couvert par la présente norme doit contribuer à sa propre intégrité et stabilité, mais sans contribuer à la résistance ou à la stabilité de la structure du bâtiment et pourrait être remplacé de manière indépendante.
La présente norme s’applique au kit de façade rideau variant de la position verticale à une position inclinée de ± 15° par rapport à la verticale. Il convient que toutes pièces inclinées soient contenues dans le kit de façade rideau.
La présente norme s'applique à l'intégralité des kits de façades rideaux, y compris les points d'attache.
Conformément à la présente norme, une façade rideau est conçue pour être utilisée comme une partie de l’enveloppe du bâtiment.
La présente Norme européenne n’inclut pas :
des kits de systèmes de vitrages auto-drainant à joint secs (toits inclinés vitrés) ;
des verrières ;
façades constituées de panneaux en béton préfabriqués faisant partie du mur (voir l'EN 14992).
NOTE 1 Les panneaux de béton préfabriqués peuvent être utilisés dans les kits de façades rideaux comme panneaux de remplissage.
NOTE 2 Durabilité des remplissages de vitrage collés (VEC) ne sont pas couverts par cette norme.
Obešene fasade - Standard za proizvod
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 13830:2015+A1:2020
01-julij-2020
Nadomešča:
SIST EN 13830:2015
Obešene fasade - Standard za proizvod
Curtain walling - Product standard
Vorhangfassaden - Produktnorm
Façades rideaux - Norme de produit
Ta slovenski standard je istoveten z: EN 13830:2015+A1:2020
ICS:
91.060.10 Stene. Predelne stene. Walls. Partitions. Facades
Fasade
SIST EN 13830:2015+A1:2020 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 13830:2015+A1:2020
---------------------- Page: 2 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1
EUROPEAN STANDARD
NORME EUROPÉENNE
May 2020
EUROPÄISCHE NORM
ICS 91.060.10 Supersedes EN 13830:2015
English Version
Curtain walling - Product standard
Façades rideaux - Norme de produit Vorhangfassaden - Produktnorm
This European Standard was approved by CEN on 7 February 2015 and includes Amendment 1 approved by CEN on 7 October
2019.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13830:2015+A1:2020 E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
Contents Page
European foreword . 6
Introduction . 7
1 Scope . 8
2 Normative references . 8
3 Terms, definitions and abbreviated terms . 12
3.1 Definitions . 12
3.2 Abbreviations used in this standard . 14
4 Product characteristics . 14
4.1 Reaction to fire (of components, when relevant) . 14
4.2 Fire resistance . 15
4.3 Fire propagation (to upper levels) . 15
4.4 Watertightness . 15
4.5 Resistance to its own dead load . 15
4.6 Wind load resistance . 15
4.7 Resistance to snow load (only for elements subjected to snow load). 16
4.8 Impact resistance . 16
4.8.1 General . 16
4.8.2 Internal . 16
4.8.3 External . 16
4.9 Resistance to live horizontal loads at sill level . 16
4.10 Seismic resistance . 16
4.10.1 General . 16
4.10.2 Safety in use. 17
4.10.3 Serviceability (where specially required) . 17
4.11 Thermal shock resistance . 17
4.12 Direct airborne sound insulation . 17
4.13 Flanking sound transmission . 17
4.14 Thermal transmittance . 17
4.15 Air permeability . 17
4.16 Water vapour permeability . 17
4.17 Radiation properties . 18
4.18 Durability . 18
4.18.1 General . 18
4.18.2 Durability of watertightness . 18
4.18.3 Durability of thermal transmittance . 18
4.18.4 Durability of air permeability . 18
5 Testing, assessment and sampling methods . 19
5.1 Sampling . 19
5.1.1 General . 19
5.1.2 Sequence of testing . 19
5.2 Reaction to fire (of components, when relevant) . 20
5.3 Fire resistance . 20
5.4 Fire propagation (to upper levels) . 20
5.5 Watertightness . 20
5.6 Resistance to its own dead load . 20
2
---------------------- Page: 4 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
5.7 Wind load resistance . 21
5.8 Resistance to snow load (only for elements subject to snow load) . 21
5.9 Impact resistance. 21
5.10 Resistance to live horizontal loads at sill level . 22
5.11 Seismic resistance . 22
5.11.1 Safety in use . 22
5.11.2 Serviceability (where specially required) . 22
5.12 Direct airborne sound insulation . 22
5.13 Flanking sound transmission . 22
5.14 Thermal transmittance. 22
5.15 Air permeability . 23
5.16 Radiation properties . 23
5.17 Durability. 23
5.17.1 General . 23
5.17.2 Durability of watertightness . 23
5.17.3 Durability of thermal transmittance . 24
5.17.4 Durability of air permeability . 24
6 Assessment and verification of constancy of performance (AVCP) . 25
6.1 General . 25
6.2 Type testing . 25
6.2.1 General . 25
6.2.2 Test samples, testing and compliance criteria . 26
6.2.3 Test reports . 27
6.2.4 Cascading determination of the product type results . 27
6.3 Factory production control (FPC) . 28
6.3.1 General . 28
6.3.2 Requirements . 29
6.3.3 Product specific requirements . 32
6.3.4 Initial inspection of factory and of FPC . 32
6.3.5 Continuous surveillance of FPC (only for curtain walling kits covered by AVCP
system 1) . 33
6.3.6 Procedure for modifications . 33
6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced
in very low quantity . 33
Annex A " (informative) Resistance to actions: guidance on the use of Eurocodes . 38
A.1 Introduction of the annex . 38
A.2 Scope of the annex . 38
A.3 Symbols and abbreviations in the annex . 38
A.4 Definition and principle . 39
A.4.1 General . 39
A.4.2 Classes of consequence . 40
A.4.3 Curtain walling kit operating as safety barrier . 40
A.4.4 Loaded area "A" . 40
A.4.5 System redundancy . 42
A.5 Requirements . 42
A.6 Actions . 42
3
---------------------- Page: 5 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
A.6.1 Dead load action . 42
A.6.2 Wind action . 42
A.6.3 Actions for curtain walling serving as parapets . 43
A.7 Assumptions related the combinations of actions . 44
A.7.1 General . 44
A.7.2 Combinations of actions: generalities . 45
Annex B " (normative) Seismic resistance. 50
B.1 General principles . 50
B.1.1 Required performance limits . 50
B.1.2 Factors affecting seismic performance . 50
B.2 Assessment of seismic serviceability limit . 50
B.3 Assessment of seismic safety limit . 51
B.4 Seismic movement regime . 51
B.4.1 General . 51
B.4.2 Principles . 52
B.4.3 Test apparatus. 52
B.4.4 Test procedure . 52
Annex C " (normative) Selection, preparation, mounting and fixing of test specimen for
reaction to fire tests of curtain walling and field of direct application . 58
C.1 General . 58
C.2 EN ISO 11925-2:2010 (Single flame test) . 59
C.2.1 Profile . 59
C.2.2 Infill . 61
C.2.3 Sealing between infill and profile . 61
C.2.4 Organic coating/top layers . 63
C.3 Mounting and fixing for EN 13238 (SBI-test) . 63
C.4 EN ISO 1182 (Non-combustibility test) . 64
C.5 EN ISO 1716 (Determination of the heat of combustion) . 65
C.6 Field of direct application . 65
Annex D " (normative) Characteristics and range of direct application . 67
D.1 General . 67
D.2 Selection of a representative test specimen . 74
Annex E " (informative) Characteristics and performances of curtain walling kit . 77
Annex F " (informative) Interchangeability between characteristics and components . 80
Annex G " (informative) Basic approach to durability . 83
Annex ZA (informative) !Relationship to this European Standard with
Regulation (EU) No.305/2011 (When applying this standard as a harmonized
4
---------------------- Page: 6 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
standard under Regulation (EU) No. 305/2011, manufacturers and Member States
are obliged by this regulation to use this Annex) " . 85
ZA.1 Scope and relevant characteristics . 85
ZA.2 !System of Assessment and Verification of Constancy of Performance (AVCP)" . 87
ZA.3 !Assignment of AVCP tasks . 87
Bibliography . 90
5
---------------------- Page: 7 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
European foreword
This document (EN 13830:2015+A1:2020) has been prepared by Technical Committee CEN/TC 33
“Doors, windows, shutters, building hadware and curtain walling”, the secretariat of which is held by
AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by November 2020, and conflicting national standards
shall be withdrawn at the latest by February 2023.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
This document includes Amendment 1 approved by CEN on 7 October 2019.
This document supersedes !EN 13830:2015".
The start and finish of text introduced or altered by amendment is indicated in the text by tags !".
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements of EU Directive(s).
For relationship with EU Directive, see informative Annexe ZA, which is an integral part of this
document.
The new revision extends the scope to sloping parts included in the curtain walling kit and clarifies the
exclusion of the following products:
−
“Patent glazing” (glazed sloping roofs) kits;
−
Roof glazing constructions;
−
Façades made of precast concrete panels as part of the wall (see EN 14992).
Here below the list the most important changes compared with the previous version EN 13830:2003:
−
new characteristics were added;
−
new annexes were introduced, particularly the one for the range of direct application of
characteristics (extension rules);
−
the durability was dealt in details in !Annex G";
−
updated Clause 6 and Annex ZA with the provisions of the EU Construction Product Regulation No.
305/2011.
According to the CEN-CENELEC Internal Regulations, the national standards organisations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, North Macedonia, Norway, Poland,
Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United
Kingdom.
6
---------------------- Page: 8 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
Introduction
This European Standard specifies the technical characteristics of curtain walling kit and includes a
systematic framework of requirements, test methods and compliance criteria to allow the product to
fulfil with it.
Curtain walling kit might not be completed in all respects within a manufacturing area, and some kit
components could be supplied separately on site. Curtain walling kit could be also preassembled in
plant(s) as prefabricated units.
7
---------------------- Page: 9 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
1 Scope
This European Standard specifies requirements of curtain walling kit intended to be used as a building
envelope to provide weather resistance, safety in use and energy economy and heat retention and
provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability
but does not contribute to the load bearing or stability of the main building structure, and could be
replaced independently of it.
This standard applies to curtain walling kit ranging from a vertical position to ± 15° from the vertical.
Any sloping parts should be contained within the curtain walling kit.
This standard is applicable to the whole of the curtain walling kits, including the fixings.
Curtain walling according to this standard is intended to be used as part of the building envelope.
This European Standard does not include:
— “Patent glazing” (glazed sloping roofs) kits;
— Roof glazing constructions;
— Façades made of precast concrete panels as part of the wall (see EN 14992).
NOTE 1 Precast concrete panels may be used in curtain walling kits as infill panels.
NOTE 2 Durability of structural sealed glazing infills is not covered by this standard.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 410, Glass in building - Determination of luminous and solar characteristics of glazing
EN 1096-2, Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S
coatings
EN 1096-3, Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D
coatings
EN 1096-4, Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard
EN 1279-1, Glass in Building - Insulating glass units - Part 1: Generalities, dimensional tolerances and
rules for the system description
EN 1279-2, Glass in building - Insulating glass units - Part 2: Long term test method and requirements for
moisture penetration
EN 1279-3, Glass in building - Insulating glass units - Part 3: Long term test method and requirements for
gas leakage rate and for gas concentration tolerances
EN 1279-4, Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of
edge seals
8
---------------------- Page: 10 ----------------------
SIST EN 13830:2015+A1:2020
EN 13830:2015+A1:2020 (E)
EN 1279-5, Glass in building - Insulating glass units - Part 5: Evaluation of conformity
EN 1364-3, Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration
(complete assembly)
EN 1364-4, Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part
configuration
EN 1991-1-1, Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self-weight,
imposed loads for buildings
EN 1991-1-3, Eurocode 1 - Actions on structures - Part 1-3: General actions - Snow loads
EN 1991-1-4, Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions
EN 1998-1:2004, Eurocode 8: Design of structures for earthquake resistance - Part 1: General
...
Questions, Comments and Discussion