This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...
view more

    • sale 10% off
    • Standard
      90 pages
      English language
    • e-Library read for
      1 day

This document specifies methods for the calculation of the thermal transmittance of windows and
pedestrian doors consisting of glazed and/or opaque panels fitted in a frame, with and without shutters.
This document allows for
— different types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity
coatings, and with spaces filled with air or other gases),
— opaque panels within the window or door,
— various types of frames (wood, plastic, metallic with and...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      53 pages
      English language
    • e-Library read for
      1 day

ISO 10077-1:2017 specifies methods for the calculation of the thermal transmittance of windows and pedestrian doors consisting of glazed and/or opaque panels fitted in a frame, with and without shutters.

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      53 pages
      English language
    • e-Library read for
      1 day

This part of ISO 10140 specifies laboratory methods for measuring the impact sound insulation of floor assemblies. The test results can be used to compare the sound insulation properties of building elements, classify elements according to their sound insulation capabilities, help design building products which require certain acoustic properties and estimate the in situ performance in complete buildings. The measurements are performed in laboratory test facilities in which sound transmission vi...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...
view more

    • sale 10% off
    • Standard
      90 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a pendulum impact test method for single flat panes of glass for use in buildings. The test is intended to classify flat glass products in three principal classes by performance under impact and by mode of breakage.
This standard does not specify requirements for applications, nor does it specify requirements for durability.

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies a pendulum impact test method for single flat panes of glass for use in buildings. The test is intended to classify flat glass products in three principal classes by performance under impact and by mode of breakage.
This standard does not specify requirements for applications, nor does it specify requirements for durability.

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This standard defines the method to be used to check for any points of water leakage that may occur in curtain walling when installed on a building. It is a supplementary test not required for classification purposes. It is intended for use primarily where water leaks have already occured. It may also be used on new installations, when specified.
It describes how an area of curtain walling that is installed on a building shall be subjected to a continuous film of water over its outside face
...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This standard defines the method for determining the watertightness of curtain walling, both its fixed and openable parts. It describes how the outside face of the specimen should be subjected to a continuous film of water with a positive static air pressure. NOTE: This standard applies to curtain walling in accordance with WI 00033238.

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

This standard defines the method to be used to determine the air permeability of curtain walling, both its fixed and openable parts. It describes how the specimen shall be tested under positive and negative air pressure. NOTE: This standard applies to any curtain walling product as defined in WI 00033238.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This standard defines the method for determining the resistance to wind load of curtain walling, both its fixed and openable parts, under postive and negative static air pressure. NOTE : This standard applies to any curtain walling product as defined in WI 00033238.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This standard defines the method to be used to check for any points of water leakage that may occur in curtain walling when installed on a building. It is a supplementary test not required for classification purposes. It is intended for use primarily where water leaks have already occured. It may also be used on new installations, when specified.
It describes how an area of curtain walling that is installed on a building shall be subjected to a continuous film of water over its outside face
...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This standard defines the method to be used to determine the air permeability of curtain walling, both its fixed and openable parts. It describes how the specimen shall be tested under positive and negative air pressure. NOTE: This standard applies to any curtain walling product as defined in WI 00033238.

    • sale 10% off
    • Standard
      13 pages
      English language
    • e-Library read for
      1 day

This standard defines the method for determining the watertightness of curtain walling, both its fixed and openable parts. It describes how the outside face of the specimen should be subjected to a continuous film of water with a positive static air pressure. NOTE: This standard applies to curtain walling in accordance with WI 00033238.

    • sale 10% off
    • Standard
      12 pages
      English language
    • e-Library read for
      1 day

This standard defines the method for determining the resistance to wind load of curtain walling, both its fixed and openable parts, under postive and negative static air pressure. NOTE : This standard applies to any curtain walling product as defined in WI 00033238.

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document provides a test method for determining the bearing capacity (pull out force) of a connection consisting of a screw in a screw thread channel, which cannot be calculated in accordance with current codes or conventional calculations. This document can be applied to several products, including doors, windows and curtain walling.
This document applies to screw thread channels made out of metal as well as metal screws.
The pull out forces of such connections may already be assessed in...
view more

    • sale 10% off
    • Draft
      13 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...
view more

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

ISO 10140-3:2010 specifies laboratory methods for measuring the impact sound insulation of floor assemblies.
The test results can be used to compare the sound insulation properties of building elements, classify elements according to their sound insulation capabilities, help design building products which require certain acoustic properties and estimate the in situ performance in complete buildings.

    • sale 10% off
    • Amendment
      4 pages
      German language
    • e-Library read for
      1 day

ISO 10140-3:2010 specifies laboratory methods for measuring the impact sound insulation of floor assemblies.
The test results can be used to compare the sound insulation properties of building elements, classify elements according to their sound insulation capabilities, help design building products which require certain acoustic properties and estimate the in situ performance in complete buildings.

    • sale 10% off
    • Amendment
      4 pages
      German language
    • e-Library read for
      1 day

This European Standard specifies requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
The curtain walling kit covered by this standard should fulfil its own integrity and mechanical stability but does not contribute to the load bearing or stability of the main building structure, and co...
view more

    • sale 10% off
    • Amendment
      8 pages
      English language
    • e-Library read for
      1 day

This document provides a test method for determining the bearing capacity (pull out force) of a connection consisting of a screw in a screw thread channel, which cannot be calculated in accordance with current codes or conventional calculations. This document can be applied to screw thread channels used in several products, including doors, windows and curtain walling.
This document is applicable to screw thread channels made out of metal, as well as metal screws.
The pull out forces of such c...
view more

    • sale 10% off
    • Draft
      13 pages
      English language
    • e-Library read for
      1 day