ASTM E2481-12(2023)
(Test Method)Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules
Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules
SIGNIFICANCE AND USE
4.1 The design of a photovoltaic module or system intended to provide safe conversion of the sun's radiant energy into useful electricity must take into consideration the possibility of partial shadowing of the module(s) during operation. This test method describes a procedure for verifying that the design and construction of the module provides adequate protection against the potential harmful effects of hot spots during normal installation and use.
4.2 This test method describes a procedure for determining the ability of the module to provide protection from internal defects which could cause loss of electrical insulation or combustion hazards.
4.3 Hot spot heating occurs in a module when its operating current exceeds the reduced short-circuit current (ISC) of a shadowed or faulty cell or group of cells. When such a condition occurs, the affected cell or group of cells is forced into reverse bias and must dissipate power, which can cause overheating.
Note 1: The correct use of bypass diodes can prevent hot spot damage from occurring.
4.4 Fig. 1 illustrates the hot spot effect in a module of a series string of cells, one of which, cell Y, is partially shadowed. The amount of electrical power dissipated in Y is equal to the product of the module current and the reverse voltage developed across Y. For any irradiance level, when the reverse voltage across Y is equal to the voltage generated by the remaining (s-1) cells in the module, power dissipation is at a maximum when the module is short-circuited. This is shown in Fig. 1 by the shaded rectangle constructed at the intersection of the reverse I-V characteristic of Y with the image of the forward I-V characteristic of the (s-1) cells.
FIG. 1 Hot Spot Effect
4.5 Bypass diodes, if present, as shown in Fig. 2, begin conducting when a series-connected string in a module is in reverse bias, thereby limiting the power dissipation in the reduced-output cell.
FIG. 2 Bypass Diode Effect
Note 2: If the ...
SCOPE
1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or nonuniform) shadowing, or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials.
1.2 There are two ways that cells can cause a hot spot problem: either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high current flow in a localized region. This test method selects cells of both types to be stressed.
1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method.
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2481 − 12 (Reapproved 2023) An American National Standard
Standard Test Method for
1
Hot Spot Protection Testing of Photovoltaic Modules
This standard is issued under the fixed designation E2481; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This test method provides a procedure to determine the
E772 Terminology of Solar Energy Conversion
ability of a photovoltaic (PV) module to endure the long-term
E927 Classification for Solar Simulators for Electrical Per-
effects of periodic “hot spot” heating associated with common
formance Testing of Photovoltaic Devices
fault conditions such as severely cracked or mismatched cells,
E1036 Test Methods for Electrical Performance of Noncon-
single-point open circuit failures (for example, interconnect
centrator Terrestrial Photovoltaic Modules and Arrays
failures), partial (or nonuniform) shadowing, or soiling. Such
Using Reference Cells
effects typically include solder melting or deterioration of the
E1799 Practice for Visual Inspections of Photovoltaic Mod-
encapsulation, but in severe cases could progress to combus-
ules
tion of the PV module and surrounding materials.
E1802 Test Methods for Wet Insulation Integrity Testing of
Photovoltaic Modules
1.2 There are two ways that cells can cause a hot spot
problem: either by having a high resistance so that there is a
3. Terminology
large resistance in the circuit, or by having a low resistance
3.1 Definitions—Definitions of terms used in this test
area (shunt) such that there is a high current flow in a localized
method may be found in Terminology E772.
region. This test method selects cells of both types to be
3.2 Definitions of Terms Specific to This Standard:
stressed.
3.2.1 hot spot—a condition that occurs, usually as a result of
1.3 This test method does not establish pass or fail levels.
shadowing, when a solar cell or group of cells is forced into
The determination of acceptable or unacceptable results is
reverse bias and must dissipate power, which can result in
beyond the scope of this test method.
abnormally high cell temperatures.
1.4 The values stated in SI units are to be regarded as
4. Significance and Use
standard. No other units of measurement are included in this
4.1 The design of a photovoltaic module or system intended
standard.
to provide safe conversion of the sun’s radiant energy into
1.5 This standard does not purport to address all of the
useful electricity must take into consideration the possibility of
safety concerns, if any, associated with its use. It is the
partial shadowing of the module(s) during operation. This test
responsibility of the user of this standard to establish appro- method describes a procedure for verifying that the design and
priate safety, health, and environmental practices and deter- construction of the module provides adequate protection
against the potential harmful effects of hot spots during normal
mine the applicability of regulatory limitations prior to use.
installation and use.
1.6 This international standard was developed in accor-
dance with internationally recognized principles on standard-
4.2 This test method describes a procedure for determining
ization established in the Decision on Principles for the
the ability of the module to provide protection from internal
Development of International Standards, Guides and Recom- defects which could cause loss of electrical insulation or
mendations issued by the World Trade Organization Technical combustion hazards.
Barriers to Trade (TBT) Committee.
4.3 Hot spot heating occurs in a module when its operating
current exceeds the reduced short-circuit current (I ) of a
SC
shadowed or faulty cell or group of cells. When such a
1
This test method is under the jurisdiction of ASTM Committee E44 on Solar,
Geothermal and Other Alternative Energy Sources and is the direct responsibility of
2
Subcommittee E44.09 on Photovoltaic Electric Power Conversion. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Aug. 1, 2023. Published August 2023. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2006. Last previous edition approved in 2018 as E2481 – 12 (2018). Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/E2481-12R23. the ASTM website.
Copyright © ASTM Internation
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.