ASTM D2844/D2844M-13
(Test Method)Standard Test Method for Resistance R-Value and Expansion Pressure of Compacted Soils
Standard Test Method for Resistance <i>R</i>-Value and Expansion Pressure of Compacted Soils
SIGNIFICANCE AND USE
4.1 This test method is used to measure the potential strength of subgrade, subbase, and base course materials for use in road and airfield pavements. The R-value is used by some agencies as criteria for acceptance of aggregates for base course and bituminous courses.
FIG. 1 Tamper Shoe for Kneading Compactor
4.2 The expansion pressure testing has been used in conjunction with the R-value test to determine cover requirements (thickness) and construction controls to reduce pavement distortion from expansive subgrade soils. Note 1—The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this test method are cautioned that compliance with Practice D3740 does not in itself ensure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
SCOPE
1.1 This test method covers the procedure for testing both treated and untreated laboratory compacted soils or aggregates with the stabilometer and expansion pressure devices to obtain results indicative of performance when placed in the base, subbase, or subgrade of a road subjected to traffic.
1.2 Units—The values stated in either SI units or inch-pound units [presented in brackets] are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. However, use of equipment manufactured to be readable in inch-pound units only should not be considered as non-conformance to the test method. Many stabilometers and expansion pressure devices are manufactured to be readable in inch-pound units only.
1.3 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.
1.3.1 For purposes of comparing measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal or significant digits in the specified limits.
1.3.2 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user's objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D2844/D2844M − 13
Standard Test Method for
ResistanceR-Value and Expansion Pressure of Compacted
1
Soils
This standard is issued under the fixed designation D2844/D2844M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 1.4 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
1.1 This test method covers the procedure for testing both
responsibility of the user of this standard to establish appro-
treated and untreated laboratory compacted soils or aggregates
priate safety and health practices and determine the applica-
with the stabilometer and expansion pressure devices to obtain
bility of regulatory limitations prior to use.
results indicative of performance when placed in the base,
subbase, or subgrade of a road subjected to traffic.
2. Referenced Documents
2
1.2 Units—The values stated in either SI units or inch- 2.1 ASTM Standards:
pound units [presented in brackets] are to be regarded sepa- C670Practice for Preparing Precision and Bias Statements
ratelyasstandard.Thevaluesstatedineachsystemmaynotbe for Test Methods for Construction Materials
exact equivalents; therefore, each system shall be used inde- D653Terminology Relating to Soil, Rock, and Contained
pendentlyoftheother.Combiningvaluesfromthetwosystems Fluids
may result in non-conformance with the standard. However, D3740Practice for Minimum Requirements for Agencies
use of equipment manufactured to be readable in inch-pound Engaged in Testing and/or Inspection of Soil and Rock as
units only should not be considered as non-conformance to the Used in Engineering Design and Construction
test method. Many stabilometers and expansion pressure de- D6026Practice for Using Significant Digits in Geotechnical
vicesaremanufacturedtobereadableininch-poundunitsonly. Data
E4Practices for Force Verification of Testing Machines
1.3 All observed and calculated values shall conform to the
E11Specification forWovenWireTest Sieve Cloth andTest
guidelines for significant digits and rounding established in
Sieves
Practice D6026.
2.2 AASHTO Documents:
1.3.1 For purposes of comparing measured or calculated
T190 Test Method for Resistance R-Value and Expansion
value(s) with specified limits, the measured or calculated 3
Pressure of Compacted Soils
value(s) shall be rounded to the nearest decimal or significant
4
2.3 ASTM Adjuncts:
digits in the specified limits.
Exudation Device
1.3.2 Theproceduresusedtospecifyhowdataarecollected/
Expansion Pressure Apparatus
recorded or calculated, in this standard are regarded as the
Stabilometer
5
industry standard. In addition, they are representative of the
2.4 CALTRANS Standard:
significant digits that generally should be retained. The proce-
California Test 103Method of Test For Calibration of
dures used do not consider material variation, purpose for
Expansion Pressure Devices
obtaining the data, special purpose studies, or any consider-
ations for the user’s objectives; and it is common practice to
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
increase or reduce significant digits of reported data to be
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
commensuratewiththeseconsiderations.Itisbeyondthescope Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
of this standard to consider significant digits used in analytical
3
Available from American Association of State Highway and Transportation
methods for engineering design.
Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001,
http://www.transportation.org.
4
CopiesofdetaileddrawingsoftheapparatusshowninFigs.4(1drawing),7(4
drawings), 10 and 11 (7 drawings) are available at a nominal cost from ASTM
1
ThistestmethodisunderthejurisdictionofASTMCommitteeD18onSoiland International Headquarters. RequestAdjunct Nos. ADJD284401,ADJD284402, and
Rock and is the direct responsibility of Subcommittee D18.08 on Special and ADJD284403, respectively.
5
Construction Control Tests. Available from State of California Department of Transportation
Current edition approved Jan. 1, 2013. Published February 2013. Originally (CALTRANS), P.O. Box 942873, Sacramento, CA 94273-0001, http://
ε1
approved in 1969. Last previous edition approved in 2007 as D2844 – 07 . DOI: www.dot.ca.gov. Proving Lever Assembly detailed drawings are available here as
10.1520/D2844_D2844M-13. well.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Bo
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: D2844 − 07 D2844/D2844M − 13
Standard Test Method for
Resistance R-Value and Expansion Pressure of Compacted
1
Soils
This standard is issued under the fixed designation D2844;D2844/D2844M; the number immediately following the designation indicates
the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Added research report information to Section 12 editorially in September 2010.
1. Scope*
1.1 This test method covers the procedure for testing both treated and untreated laboratory compacted soils or aggregates with
the stabilometer and expansion pressure devices to obtain results indicative of performance when placed in the base, subbase, or
subgrade of a road subjected to traffic.
1.2 Units—The values stated in either SI units or inch-pound units [presented in brackets] are to be regarded as the separately
as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently
of the other. Combining values from the two systems may result in non-conformance with the standard. However, use of equipment
manufactured to be readable in inch-pound units only should not be considered as non-conformance to the test method. Many
stabilometers and expansion pressure devices are manufactured to be readable in inch-pound units only.
1.3 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice
D6026.
1.3.1 For purposes of comparing measured or calculated value(s) with specified limits, the measured or calculated value(s) shall
be rounded to the nearest decimal or significant digits in the specified limits.
1.3.2 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry
standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not
consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives;
and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations.
It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
D653 Terminology Relating to Soil, Rock, and Contained Fluids
D3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or Inspection of Soil and Rock as Used in
Engineering Design and Construction
D6026 Practice for Using Significant Digits in Geotechnical Data
E4 Practices for Force Verification of Testing Machines
E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves
2.2 AASHTO Documents:
3
T 190 Test Method for Resistance R-Value and Expansion Pressure of Compacted Soils
1
This test method is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.08 on Special and Construction
Control Tests.
Current edition approved Feb. 1, 2007Jan. 1, 2013. Published March 2007February 2013. Originally approved in 1969. Last previous edition approved in 20012007 as
ε1
D2844 – 0107 . DOI: 10.1520/D2844-07E01.10.1520/D2844_D2844M-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American Association of State Highway and Transportation Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001,
http://www.transportation.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
D2844/D2844M − 13
4
2.3 ASTM Adju
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.