ASTM E1975-15
(Specification)Standard Specification for Shelter, Electrical, Equipment S-280/G
Standard Specification for Shelter, Electrical, Equipment S-280/G
ABSTRACT
This specification covers one type of lightweight field and mobile shelter designed for transport by cargo truck, fixed or rotary winged aircraft, rail, and ship, as shelter, electrical equipment S-280/G. Core, adhesive, and sealer materials used in the construction of this item shall be in accordance with the density, compressive strength, shear strength, flammability, and water absorption requirements. Shock mounts shall be subjected to hardness, resilience, and depression-deflection tests to check for compliance with specified requirements. Construction properties shall comply with the cleaning, arc or resistance welding, lamination (impact resistance), vapor seal, interchangeability, riveting, finishing, marking, shelter gross weight, service integrity, and tightness preconditioning specifications. Environmental service conditions such as moisture resistance, rapid temperature changes, and thermal differential including thermal deformation and heat transfer shall be met. The shelter shall also conform to the requirements for transportability whether in rail or air transport, capability to withstand flat and rotational drops and simulated towing, lifting and towing eye casting hardness, and static door and roof access steps vertical loads for structural integrity. Tightness tests shall be conducted as well to verify shielding from air, door latch torque, light, electromagnetic interference, water, and fording.
SCOPE
1.1 This specification covers one type of lightweight field and mobile shelter designed for transport by cargo truck, fixed or rotary winged aircraft, by rail, and ship, as Shelter, Electrical Equipment S-280/G (see 15.5).
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat refers only to the test methods described in this specification. This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of the standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E1975 −15
Standard Specification for
1
Shelter, Electrical, Equipment S-280/G
This standard is issued under the fixed designation E1975; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope E1749 Terminology Relating to Rigid Wall Relocatable
Shelters
1.1 This specification covers one type of lightweight field
E1773 Practice for Sealing RigidWallTactical Shelters with
and mobile shelter designed for transport by cargo truck, fixed
Polysulfide Based Sealants
orrotarywingedaircraft,byrail,andship,asShelter,Electrical
E1794 Specification for Adhesive for Bonding Foam Cored
Equipment S-280/G (see 15.5).
Sandwich Panels (200°F Elevated Humidity Service),
1.2 The values stated in inch-pound units are to be regarded
Type II Panels
as standard. The values given in parentheses are mathematical
E1801 Practice forAdhesive Bonding ofAluminum Facings
conversions to SI units that are provided for information only
in Foam and Beam Type Shelters
and are not considered standard.
E1851 Test Method for Electromagnetic Shielding Effec-
1.3 The following safety hazards caveat refers only to the
tiveness of Durable Rigid Wall Relocatable Structures
test methods described in this specification.This standard does E1925 Specification for Engineering and Design Criteria for
not purport to address the safety concerns, if any, associated
Rigid Wall Relocatable Structures
3
with its use. It is the responsibility of the user of the standard
2.2 Commercial Standards:
to establish appropriate safety and health practices and
SAE AMS-W-6858 Welding, Resistance: Spot and Seam
determine the applicability of regulatory limitations prior to
SAEAMS-STD-1595 Qualification ofAircraft, Missile, and
use.
Aerospace Fusion Welders
4
2.3 Federal Air Regulation (FAR):
2. Referenced Documents
FAR 25.853 Compartment Interior
2
2.1 ASTM Standards:
2.4 Military Standards:
C273/C273M Test Method for Shear Properties of Sandwich
5
MIL-F-14072 Finishes for Ground Electronic Equipment
Core Materials
MIL-DTL-55507 Shelter, Electrical Equipment, (With or
D1621 Test Method for Compressive Properties of Rigid
5
Without Equipment), Packaging of
Cellular Plastics
5
MIL-STD-202 Electronic and Electrical Component Parts
D1622/D1622M Test Method forApparent Density of Rigid
MIL-STD-252 Wired Equipment, Classification of Visual
Cellular Plastics
and Mechanical Defects for Equipment, Electronic,
D2842 Test Method for Water Absorption of Rigid Cellular
5
Wired, and Other Devices
Plastics
MIL-STD-810 Environmental Engineering Considerations
E631 Terminology of Building Constructions
5
and Laboratory Tests
E864 Practice for Surface Preparation of Aluminum Alloys
MIL-STD-1916 DOD Preferred Methods for Acceptance of
to Be Adhesively Bonded in Honeycomb Shelter Panels
6
Product
E1730 Specification for Rigid Foam for Use in Structural
MIL-STD-2219 Fusion Welding for Aerospace Applica-
Sandwich Panel Cores
6
tions
5
MIL-M-13231 Marking of Electronic Items
1
This specification is under the jurisdiction of ASTM Committee E06 on
Performance of Buildings and is the direct responsibility of Subcommittee E06.53
3
on Materials and Processes for Durable Rigidwall Relocatable Structures. Available from AMS Publications, SAE International (SAE), 400 Common-
Current edition approved May 1, 2015. Published August 2015. Originally wealth Dr., Warrendale, PA 15096-0001, http://www.sae.org.
4
approved in 1998. Last previous edition approved in 2009 as E1975 – 09. DOI: Available from Flight Standards Service, Federal Aviation Administration
10.1520/E1975-15. (FAA), 800 Independence Ave., SW, Washington, DC 20591, http://www.faa.gov.
2 5
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from DLA Document Services, Building 4/D, 700 Robbins Ave.,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Philadelphia, PA 19111-5094, http://quicksearch.dla.mil.
6
Standards volume information, refer to the standard’s Document Summary page on Available from US Army Natick Soldier Systems Center, ATTN: AMSRD-
the ASTM website. NSC-CP-CS, Kansas Street, Natick, MA 01760-5018, http://www.army.mil/natick.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E1975−15
6
2.5 Drawings: 3.1.2 examination—examination consists of simple, gener-
SC-D-36423 Hold Down Assembly ally nondestructive determinations of compliance, without the
SC-D-36424
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E1975 − 09 E1975 − 15
Standard Specification for
1
Shelter, Electrical, Equipment S-280/G
This standard is issued under the fixed designation E1975; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope
1.1 This specification covers one type of lightweight field and mobile shelter designed for transport by cargo truck, fixed or
rotary winged aircraft, by rail, and ship, as Shelter, Electrical Equipment S-280/G (see 15.5).
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information
only.mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following safety hazards caveat refers only to the test methods described in this specification.This standard does not
purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of the standard to establish
appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C273C273/C273M Test Method for Shear Properties of Sandwich Core Materials
D1621 Test Method for Compressive Properties of Rigid Cellular Plastics
D1622D1622/D1622M Test Method for Apparent Density of Rigid Cellular Plastics
D2842 Test Method for Water Absorption of Rigid Cellular Plastics
E631 Terminology of Building Constructions
E864 Practice for Surface Preparation of Aluminum Alloys to Be Adhesively Bonded in Honeycomb Shelter Panels
E1730 Specification for Rigid Foam for Use in Structural Sandwich Panel Cores
E1749 Terminology Relating to Rigid Wall Relocatable Shelters
E1773 Practice for Sealing Rigid Wall Tactical Shelters with Polysulfide Based Sealants
E1794 Specification for Adhesive for Bonding Foam Cored Sandwich Panels (200°F Elevated Humidity Service), Type II Panels
E1801 Practice for Adhesive Bonding of Aluminum Facings in Foam and Beam Type Shelters
E1851 Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures
E1925 Specification for Engineering and Design Criteria for Rigid Wall Relocatable Structures
3
2.2 Commercial Standards:
SAE AMS-W-6858 Welding, Resistance: Spot and Seam
SAE AMS-STD-1595 Qualification of Aircraft, Missile, and Aerospace Fusion Welders
4
2.3 Federal Air Regulation (FAR):
FAR 25.853 Compartment Interior
2.4 Military Standards:
5
MIL-F-14072 Finishes for Ground Electronic Equipment
5
MIL-DTL-55507 Shelter, Electrical Equipment, (With or Without Equipment), Packaging of
5
MIL-STD-202 Electronic and Electrical Component Parts
1
This specification is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.53 on Materials
and Processes for Durable Rigidwall Relocatable Structures.
Current edition approved Nov. 1, 2009May 1, 2015. Published December 2009August 2015. Originally approved in 1998. Last previous edition approved in 20062009
as E1975 – 06.E1975 – 09. DOI: 10.1520/E1975-09.10.1520/E1975-15.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from AMS Publications, Society of Automotive Engineers, SAE International (SAE), 400 Commonwealth Dr., Warrendale, PA 15096-0001, http://www.sae.org.
4
Available from Flight Standards Service, Federal Aviation Administration (FAA), 800 Independence Ave., SW, Washington, DC 20591, http://www.faa.gov.
5
Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA
19111-5098, http://dodssp.daps.dla.mil.19111-5094, http://quicksearch.dla.mil.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E1975 − 15
MIL-STD-252 Wired Equipment, Classification of Visual and Mechanical Defects for Equipment, Electronic, Wired, and Other
5
Devices
5
MIL-STD-810 Environment
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.