Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing

SCOPE
1.1 This specification covers (1) inorganic fiber-reinforced organic felt underlayment and ( 2) inorganic fiber-based felt for use as underlayment with steep-slope roofing products. The intent of this specification is to provide criteria for producing and evaluating underlayments with a significantly reduced tendency to wrinkle before or after the installation of steep roofing products.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 The following safety hazards caveat pertains only to the test method portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

General Information

Status
Historical
Publication Date
31-Dec-2004
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D6757-05 - Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep-Slope Roofing
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6757 – 05
Standard Specification for
Underlayment Felt Containing Inorganic Fibers Used in
1
Steep-Slope Roofing
This standard is issued under the fixed designation D 6757; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope F 1087 Test Method for Linear Dimensional Stability of a
Gasket Material to Moisture
1.1 This specification covers (1) inorganic fiber-reinforced
organic felt underlayment and (2) inorganic fiber-based felt for
3. Terminology
use as underlayment with steep-slope roofing products. The
3.1 Definitions—For definitions of terms used in this speci-
intent of this specification is to provide criteria for producing
fication, refer to Terminology D 1079.
and evaluating underlayments with a significantly reduced
tendency to wrinkle before or after the installation of steep
4. Classification
roofing products.
4.1 Organicfeltsthatarereinforcedwithinorganicfibersare
1.2 The values stated in SI units are to be regarded as the
covered by this specification.
standard. The values in parentheses are for information only.
4.2 Inorganic fiber-based asphaltic and nonasphaltic felts
1.3 The following safety hazards caveat pertains only to the
are covered by this specification.
test method portion, Section 8, of this specification: This
standard does not purport to address all of the safety concerns,
5. Materials and Manufacture
if any, associated with its use. It is the responsibility of the user
5.1 In the process of manufacture, a single thickness of
of this standard to establish appropriate safety and health
inorganic mat or organic felt that is reinforced with inorganic
practices and determine the applicability of regulatory require-
fibers shall be uniformly saturated or coated.
ments prior to use.
6. Performance Requirements
2. Referenced Documents
6.1 The material shall conform to the physical requirements
2
2.1 ASTM Standards:
prescribed in Table 1.
D 146 Test Methods for Sampling and Testing Bitumen-
6.2 The finished product shall not crack nor be so sticky as
Saturated Felts and Woven Fabrics for Roofing and Wa-
to cause tearing or other damage upon being unrolled at
terproofing
temperatures between –1 and 60°C (30 and 140°F). The
D 228 Test Methods for Sampling, Testing, andAnalysis of
finished product shall pass the water shower exposure test in
Asphalt Roll Roofing, Cap Sheets, and Shingles Used in
accordance with 8.1.4, indicating resistance to liquid water
Roofing and Waterproofing
transmission.
D 1079 Terminology Relating to Roofing, Waterproofing,
and Bituminous Materials
7. Dimensions, Masses, Workmanship, Finish, and
D 3462 SpecificationforAsphaltShinglesMadefromGlass
Appearance
Felt and Surfaced with Mineral Granules
7.1 Dimensions and masses to be agreed upon between
D 4869 Specification for Asphalt-Saturated Organic Felt
buyer and seller.
Underlayment Used in Steep Slope Roofing
7.2 The finished material shall be free of visible external
defects, such as holes, ragged or untrue edges, breaks, cracks,
1
tears, bulges, and indentations.
This specification is under the jurisdiction of ASTM Committee D08 on
Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.02
on Prepared Roofing, Shingles, and Siding Materials. 8. Sampling and Test Methods
Current edition approved Jan. 1, 2005. Published January 2005. Originally
8.1 Sample the material and determine the properties enu-
approved in 2002. Last previous edition approved in 2004 as D 6757 – 04a.
2
merated in this specification in accordance with Test Methods
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
D 146.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D6757–05
TABLE 1 Performance Requirements
8.2.2 Precision and Bias—To be determined.
Tear strength, min at 23 6 2°C, (73 6 4°F), 4.0, (0.88) (in any direction)
N, (lbf)
9. Inspection
Pliability at 23 6 2°C, (73 6 4°F), the ten strips pass
tested shall not crack when bent 90° 9.1 Inspection of the material shall be made as agreed upon
at a uniform speed over a 19 mm (0.75 in.)
betweenthepurchaserandthesupplierasapartofthepurchase
radius corner in 2 s
contract.
Behavior (loss) on heating at 105°C (221°F) 4
for 5 h, max, %
Liquid water transmission test pass
10. Rejection and Resubmittal
Dimensional stability, 1.65
low humidity to high humidity, 10.1 F
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.