Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation

ABSTRACT
This specification covers the material, dimensional, and requirements and corresponding test methods for folded poly(vinyl chloride) (PVC) pipes suitable for the rehabilitation of existing nonpressure sewers and conduits, wherein the folded PVC pipe is inserted into, and then expanded to conform to the wall of, the original conduit forming a new pipe-within-a-pipe structure. This specification does not include pipes manufactured from reprocessed, recycled, or reclaimed PVC. Appropriately sampled specimens shall be tested, and shall thereby conform accordingly to specified requirements for flattening resistance, impact strength, stiffness, extrusion quality by acetone immersion and heat reversion, flexural modulus of elasticity, and rounded pipe diameter and wall thickness.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is inserted into and then expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe.
Note 1—For installation procedures refer to Practice F1947.  
1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary statement pertains to the test method portion only, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Nov-2010
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1504-10 - Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F1504-10 - Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F1504 −10 AnAmerican National Standard
Standard Specification for
Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer
1
and Conduit Rehabilitation
This standard is issued under the fixed designation F1504; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* D790 Test Methods for Flexural Properties of Unreinforced
and Reinforced Plastics and Electrical Insulating Materi-
1.1 This specification covers requirements and test methods
als
for materials, dimensions, workmanship, flattening resistance,
D1600 Terminology forAbbreviatedTerms Relating to Plas-
impact resistance, pipe stiffness, extrusion quality, and a form
tics
of marking for folded (vinyl chloride) (PVC) pipe for existing
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
sewer and conduit rehabilitation.
Compounds and Chlorinated Poly(Vinyl Chloride)
1.2 Pipe produced to this specification is for use in non-
(CPVC) Compounds
pressure sewer and conduit rehabilitation where the folded
F1947 Practice for Installation of Folded Poly (Vinyl Chlo-
PVC pipe is inserted into and then expanded to conform to the
ride) (PVC) Pipe into Existing Sewers and Conduits
wall of the original conduit forming a new structural pipe-
D2122 Test Method for Determining Dimensions of Ther-
within-a-pipe.
moplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded
NOTE 1—For installation procedures refer to Practice F1947.
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
1.3 This specification includes pipe made only from mate-
Acetone Immersion
rials specified in Section 6. This specification does not include
D2412 Test Method for Determination of External Loading
pipe manufactured from reprocessed, recycled, or reclaimed
Characteristics of Plastic Pipe by Parallel-Plate Loading
PVC.
D2444 Test Method for Determination of the Impact Resis-
1.4 The values stated in inch-pound units are to be regarded
tance of Thermoplastic Pipe and Fittings by Means of a
as standard. The values given in parentheses are mathematical
Tup (Falling Weight)
conversions to SI units that are provided for information only
F412 Terminology Relating to Plastic Piping Systems
and are not considered standard.
F1057 Practice for Estimating the Quality of Extruded Poly
1.5 The following precautionary statement pertains to the (Vinyl Chloride) (PVC) Pipe by the Heat Reversion
test method portion only, Section 11, of this specification: This Technique
standard does not purport to address all of the safety concerns,
2.2 Federal Standard:
3
if any, associated with its use. It is the responsibility of the user
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
of this standard to establish appropriate safety and health
2.3 Military Standard:
practices and determine the applicability of regulatory limita-
3
MIL-STD-129 Marking for Shipment and Storage
tions prior to use.
3. Terminology
2. Referenced Documents
2
3.1 General—Abbreviations used in this specification are in
2.1 ASTM Standards:
accordance with Terminology D1600 and definitions are in
D618 Practice for Conditioning Plastics for Testing
accordancewithTerminologyF412unlessotherwiseindicated.
3.2 Definitions of Terms Specific to This Standard:
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
3.2.1 folded pipe—pipe that has been manufactured in a
Piping Systems and is the direct responsibility of Subcommittee F17.67 on
folded shape or that is subsequently folded for use in existing
Trenchless Plastic Pipeline Technology.
sewer and conduit rehabilitation. See Fig. 1.
Current edition approved Nov. 15, 2010. Published January 2011. Originally
approved in 1994. Last previous edition approved in 2002 as F1504 –02. DOI:
10.1520/F1504-10.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,
Standards volume information, refer to the standard’s Document Summary page on Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://
the ASTM website. dodssp.daps.dla.mil.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1504−10
6.2 Rework Material—Clean rework material, generated
from the manufacturer’s own PVC sewer pipe production may
be used by the same manufacturer provided that the rework
material meets the requirem
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F1504–02 Designation: F1504 – 10
Standard Specification for
Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer
1
and Conduit Rehabilitation
This standard is issued under the fixed designation F1504; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance,
impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded (vinyl chloride) (PVC) pipe for existing sewer
and conduit rehabilitation.
1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe
is inserted into and then expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe.
NOTE1—AnASTMspecificationfortheinstallationoffoldedPVCpipeisunderpreparationandwillbereferencedinthisspecificationwhenpublished.
1—For installation procedures refer to Practice F1947.
1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe
manufactured from reprocessed, recycled, or reclaimed PVC.
1.4The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for
information only.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary statement pertains to the test method portion only, Section 11, of this specification: This
standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior
to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
F1947 Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
F412 Terminology Relating to Plastic Piping Systems
F1057 Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique
2.2 Federal Standard:
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.67 on Trenchless
Plastic Pipeline Technology.
´1
Current edition approved Sept. 10, 2002. Published December 2002. Originally published as F1504–94. Last previous edition F1504–97 . DOI: 10.1520/F1504-02.
Current edition approved Nov. 15, 2010. Published January 2011. Originally approved in 1994. Last previous edition approved in 2002 as F1504 –02. DOI:
10.1520/F1504-10.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
F1504 – 10
3
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2.3 Military Standard:
3
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 General—Abbre
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.