Standard Specification for Shelter, Electrical, Equipment S-280/G

SCOPE
1.1 This specification covers one type of lightweight field and mobile shelter designed for transport by cargo truck, fixed or rotary winged aircraft, by rail, and ship, as Shelter, Electrical Equipment S-280/G (see 15.5).
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 The following safety hazards caveat refers only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Oct-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E1975-01a - Standard Specification for Shelter, Electrical, Equipment S-280/G
English language
17 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E 1975 – 01a
Standard Specification for
1
Shelter, Electrical, Equipment S-280/G
This standard is issued under the fixed designation E 1975; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope E 1773 Practice for Sealing Rigid Wall Tactical Shelters
5
with Polysulfide Based Sealants
1.1 This specification covers one type of lightweight field
E 1794 SpecificationforAdhesiveforBondingFoamCored
and mobile shelter designed for transport by cargo truck, fixed
SandwichPanels(200°FElevatedHumidityService),Type
orrotarywingedaircraft,byrail,andship,asShelter,Electrical
5
II Panels
Equipment S-280/G (see 15.5).
E 1801 Practice for Adhesive Bonding of Aluminum Fac-
1.2 The values stated in inch-pound units are to be regarded
5
ings in Foam and Beam Type Shelters
as the standard. The values given in parentheses are for
E 1851 Test Method for Electromagnetic Shielding Effec-
information only.
5
tiveness of Durable Rigid Wall Relocatable Structures
1.3 The following safety hazards caveat refers only to the
E 1925 Specification for Engineering and Design Criteria
test methods described in this specification. This standard does
5
for Rigid Wall Relocatable Structures
not purport to address the safety concerns, if any, associated
2.2 Federal Air Regulation (FAR):
with its use. It is the responsibility of the user of the standard
6
FAR 25.853 Compartment Interior
to establish appropriate safety and health practices and
2.3 Military Standards:
determine the applicability of regulatory limitations prior to
MIL-W-6858 Welding Resistance: Aluminum, Magnesium,
use.
Non-Hardening Steels or Alloys, Nickel Alloys, Nickel
2. Referenced Documents
Alloys, Heat-Resisting Alloys and Titanium Alloys; Spot
7
and Seam
2.1 ASTM Standards:
7
MIL-M-13231 Marking of Electronic Items
C 272 Test Method for WaterAbsorption of Core Materials
7
2
MIL-F-14072 Finishes for Ground Electronic Equipment
for Structural Sandwich Constructions
MIL-DTL-55507 Shelter, Electrical Equipment, (With or
C 273 Test Method for Shear in Flatwise Plane of Flat
7
2
Without Equipment), Packaging of
Sandwich Constructions or Sandwich Cores
MIL-STD-105 Sampling Procedures and Tables for Inspec-
D 1621 Test Method for Compressive Strength of Rigid
7
3
tion by Attributes
Cellular Plastics
MIL-STD-202 Test Methods for Electronic and Electrical
D 1622 Test Method forApparent Density of Rigid Cellular
7
3
Component Parts
Plastics
MIL-STD-252 Classification of Visual and Mechanical De-
D 2842 Test Method forWaterAbsorption of Rigid Cellular
4
fects for Equipment, Electronic, Wired, and Other De-
Plastics
7
vices
E 864 Practice for Preparation of Aluminum Alloys to be
5
MIL-STD-810 Environmental Engineering Considerations
Adhesively Bonded in Honeycomb Shelter Panels
7
and Laboratory Tests
E 1730 Specification for Rigid Foam for Use in Shelter
5
MIL-STD-1235 Single and Multilevel Continuous Sam-
Sandwich Panel Cores
7
pling Procedures and Tables for Inspection by Attributes
E 1749 Terminology Relating to Rigid Wall Relocatable
5
MIL-STD-1595 Qualification ofAircraft, Missile andAero-
Shelters
7
space Fusion Welders
2.4 Drawings:
8
SC-D-36423 Hold Down Assembly
1
This specification is under the jurisdiction of ASTM Committee E06 on
Performance of Buildings and is the direct responsibility of Subcommittee E06.53
on Materials and Processes for Durable Rigid Wall Relocatable Structures.
6
Current edition approved Oct. 10, 2001. Published November 2001. Originally Available from Flight Standards Service, FederalAviationAdministration, 800
e1
published as E 1975–98. Last previous edition E 1975–01 . Independence Ave., SW, Washington, DC 20591.
2 7
Annual Book of ASTM Standards, Vol 15.03. AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
3
Annual Book of ASTM Standards, Vol 08.01. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
4 8
Annual Book of ASTM Standards, Vol 08.02. Available from USArmy Natick Soldier Center,ATTN:AMSRD-NSC-CP-CS,
5
Annual Book of ASTM Standards, Vol 04.11. Kansas Street, Natick, MA 01760-5018.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E 1975 – 01a
8
SC-C-36424 Cable Assembly 3.1.2 examination—examination consists of simple, gener-
8
SC-C-200154 Keeper ally nondestructive determinations of compliance, without the
8
use of special testing equipment.
SM-D-450462 Panel Assembly, Emergency Exit
8
3.1.3 inspection
...

Questions, Comments and Discussion