ASTM C981-05
(Guide)Standard Guide for Design of Built-Up Bituminous Membrane Waterproofing Systems for Building Decks
Standard Guide for Design of Built-Up Bituminous Membrane Waterproofing Systems for Building Decks
SIGNIFICANCE AND USE
This guide provides information and guidelines for the selection of components and the design of a built-up bituminous membrane waterproofing system in building deck construction. Where the state of the art is such that criteria for particular conditions are not established or have numerous variables that require consideration, applicable portions of Design Considerations, Sections 5-16, serve as reference and guidance for selection by the designer of the system.
SCOPE
1.1 This guide describes the design of fully adhered built-up bituminous membrane waterproofing systems for plaza deck and promenade construction over occupied spaces of buildings where covered by a separate wearing course.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C981 −05
StandardGuide for
Design of Built-Up Bituminous Membrane Waterproofing
1
Systems for Building Decks
This standard is issued under the fixed designation C981; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D41 Specification for Asphalt Primer Used in Roofing,
Dampproofing, and Waterproofing
1.1 This guide describes the design of fully adhered built-up
D43 Specification for Coal Tar Primer Used in Roofing,
bituminous membrane waterproofing systems for plaza deck
Dampproofing, and Waterproofing
and promenade construction over occupied spaces of buildings
D173 Specification for Bitumen-Saturated Cotton Fabrics
where covered by a separate wearing course.
Used in Roofing and Waterproofing
1.2 The values stated in SI units are to be regarded as the
D226 Specification forAsphalt-Saturated Organic Felt Used
standard. The values given in parentheses are for information
in Roofing and Waterproofing
only.
D227 Specification for Coal-Tar-Saturated Organic Felt
1.3 Thecommitteewithjurisdictionoverthisstandardisnot
Used in Roofing and Waterproofing
aware of any comparable standards published by other orga-
D312 Specification for Asphalt Used in Roofing
nizations.
D449 Specification for Asphalt Used in Dampproofing and
1.4 This standard does not purport to address all of the Waterproofing
safety concerns, if any, associated with its use. It is the D450 Specification for Coal-Tar Pitch Used in Roofing,
responsibility of the user of this standard to establish appro-
Dampproofing, and Waterproofing
priate safety and health practices and determine the applica-
D1079 Terminology Relating to Roofing and Waterproofing
bility of regulatory limitations prior to use.
D1327 Specification for Bitumen-Saturated Woven Burlap
Fabrics Used in Roofing and Waterproofing
2. Referenced Documents
D1668 Specification for Glass Fabrics (Woven and Treated)
2
2.1 ASTM Standards: for Roofing and Waterproofing
C33 Specification for Concrete Aggregates D2178 Specification forAsphalt Glass Felt Used in Roofing
C578 Specification for Rigid, Cellular Polystyrene Thermal and Waterproofing
Insulation
D2822 Specification for Asphalt Roof Cement, Asbestos-
C717 Terminology of Building Seals and Sealants
Containing
C755 Practice for Selection of Water Vapor Retarders for
D4022 Specification for Coal Tar Roof Cement, Asbestos
Thermal Insulation
Containing
C1193 Guide for Use of Joint Sealants
D4586 Specification for Asphalt Roof Cement, Asbestos-
C1299 Guide for Use in Selection of Liquid-Applied Seal-
Free
3
ants (Withdrawn 2012)
D4601 Specification for Asphalt-Coated Glass Fiber Base
C1472 Guide for Calculating Movement and Other Effects
Sheet Used in Roofing
When Establishing Sealant Joint Width
D4990 SpecificationforCoalTarGlassFeltUsedinRoofing
and Waterproofing
D5295 Guide for Preparation of Concrete Surfaces for Ad-
1
This guide is under the jurisdiction of ASTM Committee D08 on Roofing and
hered (Bonded) Membrane Waterproofing Systems
Waterproofing and is the direct responsibility of Subcommittee D08.22 on Water-
D5898 Guide for Details for Adhered Sheet Waterproofing
proofing and Dampproofing Systems.
Current edition approved July 1, 2005. Published August 2005. Originally
D5957 Guide for Flood Testing Horizontal Waterproofing
approved in 1983. Last previous edition approved in 2001 as C981 – 01. DOI:
Installations
10.1520/C0981-05.
2 D6152 Specification for SEBS-Modified Mopping Asphalt
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Used in Roofing
Standards volume information, refer to the standard’s Document Summary page on
D6162 Specification for Styrene Butadiene Styrene (SBS)
the ASTM website.
3
Modified Bituminous Sheet Materials Using a Combina-
The last approved version of this historical standard is referenced on
www.astm.org. tion of Polyester and Glass Fiber Reinforcements
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
C981−05
D6163 Specification for Styrene Butadiene Styrene (SBS) amount and intensity of vibration resulting from function or
Modified Bituminous Sheet Materials Using Glass Fiber adjacent occupancies, and design live loads both normal and
Reinforcements emergency.
D6164 Specification for Styrene Butadiene Styrene (SBS)
6.2 It is essential that all components and contiguous
Modified Bituminous Sheet Materials Using Polyester
elements be compatible and coordinated to form a totally
Reinforcements
integrated waterproofing syste
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.