Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster

ABSTRACT
This specification covers the installation of lathing and furring to receive interior and exterior Portland cement-based plaster. The following materials shall be used: metal plaster bases—expanded metal lath and wire laths; accessories—steel, PVC plastic, zinc alloy, and cornerite; channels—external corner reinforcement and foundation weep screed; wire; rod and strap hangers; clips; fasteners—nails and screws. Hangers and cold-rolled channel main runner shall conform to the allowable spacing and spans, respectively. The following methods are discussed: installation of hangers for suspended ceilings under wood constructions, attachment of hangers to main runners, installation of main runners, installation of cross furring, metal furring for walls, lapping of metal plaster bases, spacing of attachments for metal plaster bases, application of metal plaster bases, and application of accessories.
SCOPE
1.1 This specification covers the minimum technical requirements for lathing and furring for the application of exterior and interior portland cement-based plaster, as in Specifications C841 or C926. These requirements do not by default define a unit of work or assign responsibility for contractual purposes, which is the purview of a contract or contracts made between contracting entities.  
1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.  
1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable requirements of Test Method E90.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

General Information

Status
Historical
Publication Date
14-Sep-2016
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1063-16c - Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1063-16c - Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
English language
11 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1063 −16c
Standard Specification for
Installation of Lathing and Furring to Receive Interior and
1
Exterior Portland Cement-Based Plaster
This standard is issued under the fixed designation C1063; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* B221 Specification forAluminum andAluminum-Alloy Ex-
truded Bars, Rods, Wire, Profiles, and Tubes
1.1 This specification covers the minimum technical re-
C11 Terminology Relating to Gypsum and Related Building
quirements for lathing and furring for the application of
Materials and Systems
exterior and interior portland cement-based plaster, as in
C841 Specification for Installation of Interior Lathing and
Specifications C841 or C926. These requirements do not by
Furring
default define a unit of work or assign responsibility for
C847 Specification for Metal Lath
contractual purposes, which is the purview of a contract or
C926 Specification for Application of Portland Cement-
contracts made between contracting entities.
Based Plaster
1.2 Where a fire resistance rating is required for plastered
C933 Specification for Welded Wire Lath
assembliesandconstructions,detailsofconstructionshallbein
C954 SpecificationforSteelDrillScrewsfortheApplication
accordance with reports of fire tests of assemblies that have
of Gypsum Panel Products or Metal Plaster Bases to Steel
met the requirements of the fire rating imposed.
Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in
Thickness
1.3 Where a specific degree of sound control is required for
plastered assemblies and constructions, details of construction C1002 Specification for Steel Self-Piercing Tapping Screws
for Application of Gypsum Panel Products or Metal
shallbeinaccordancewithofficialreportsoftestsconductedin
recognized testing laboratories in accordance with the appli- Plaster Bases to Wood Studs or Steel Studs
C1032 Specification for Woven Wire Plaster Base
cable requirements of Test Method E90.
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
1.4 The values stated in inch-pound units are to be regarded
Compounds and Chlorinated Poly(Vinyl Chloride)
as standard. The values given in parentheses are mathematical
(CPVC) Compounds
conversions to SI units that are provided for information only
D4216 Specification for Rigid Poly(Vinyl Chloride) (PVC)
and are not considered standard.
and Related PVC and Chlorinated Poly(Vinyl Chloride)
(CPVC) Building Products Compounds
2. Referenced Documents
E90 Test Method for Laboratory Measurement of Airborne
2
2.1 ASTM Standards:
Sound Transmission Loss of Building Partitions and
A641/A641M Specification for Zinc–Coated (Galvanized)
Elements
Carbon Steel Wire
A653/A653M Specification for Steel Sheet, Zinc-Coated
3. Terminology
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed)
by the Hot-Dip Process 3.1 Definitions—For definitions relating to ceilings and
B69 Specification for Rolled Zinc
walls, see Terminology C11.
3.2 Definitions of Terms Specific to This Standard:
1
This specification is under the jurisdiction of ASTM Committee C11 on
3.2.1 barrier wall, n—typeofwallsystemthatisintendedto
Gypsum and Related Building Materials and Systems and is the direct responsibility
block or interrupt the movement of water to the interior.
ofSubcommitteeC11.03onSpecificationsfortheApplicationofGypsumandOther
Products in Assemblies.
3.2.2 building enclosure, n—system of building assemblies
Current edition approved Sept. 15, 2016. Published October 2016. Originally
and materials designed and installed in such a manner as to
approved in 1986. Last previous edition approved in 2016 as C1063 – 16b. DOI:
provide a barrier between different environments.
10.1520/C1063-16C.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
3.2.3 control joint, n—a joint that accommodates movement
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
of plaster shrinkage and curing along predetermined, usually
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. straight, lines.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1063−16c
3.2.4 drainage plane, n—surface between the back of the
cladding and the front of the water resistive barrier which
resistsliquidmoistureinfiltrationandprovidesforgravitational
flow to a collection or exhaust loc
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1063 − 16b C1063 − 16c
Standard Specification for
Installation of Lathing and Furring to Receive Interior and
1
Exterior Portland Cement-Based Plaster
This standard is issued under the fixed designation C1063; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This specification covers the minimum technical requirements for lathing and furring for the application of exterior and
interior portland cement-based plaster, as in Specifications C841 or C926. These requirements do not by default define a unit of
work or assign responsibility for contractual purposes, which is the purview of a contract or contracts made between contracting
entities.
1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in
accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.
1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall
be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable
requirements of Test Method E90.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
2. Referenced Documents
2
2.1 ASTM Standards:
A641/A641M Specification for Zinc–Coated (Galvanized) Carbon Steel Wire
A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the
Hot-Dip Process
B69 Specification for Rolled Zinc
B221 Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
C11 Terminology Relating to Gypsum and Related Building Materials and Systems
C841 Specification for Installation of Interior Lathing and Furring
C847 Specification for Metal Lath
C926 Specification for Application of Portland Cement-Based Plaster
C933 Specification for Welded Wire Lath
C954 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs
from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
C1002 Specification for Steel Self-Piercing Tapping Screws for Application of Gypsum Panel Products or Metal Plaster Bases
to Wood Studs or Steel Studs
C1032 Specification for Woven Wire Plaster Base
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D4216 Specification for Rigid Poly(Vinyl Chloride) (PVC) and Related PVC and Chlorinated Poly(Vinyl Chloride) (CPVC)
Building Products Compounds
1
This specification is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of
Subcommittee C11.03 on Specifications for the Application of Gypsum and Other Products in Assemblies.
Current edition approved Sept. 1, 2016Sept. 15, 2016. Published September 2016October 2016. Originally approved in 1986. Last previous edition approved in 2016 as
C1063 – 16a.C1063 – 16b. DOI: 10.1520/C1063-16B.10.1520/C1063-16C.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1063 − 16c
E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
3. Terminology
3.1 Definitions—For definitions relating to ceilings and walls, see Terminology C11.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 barrier wall, n—type of wall system that is intended to block or interrupt the movement of water to the interior.
3.2.2 building enclosure, n—system of building assemblies and materials designed and installed in such a manner as to provid
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.