Standard Practice for Sealing Seams of Resilient Sheet Flooring Products by Use of Liquid Seam Sealers

SIGNIFICANCE AND USE
4.1 Seams in some sheet resilient flooring are sealed to prevent openings from forming between cut edges and prevent penetrations of dirt, liquids, etc., into the seams.
SCOPE
1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet resilient flooring sealed with liquid seam sealers.  
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
28-Feb-2018
Drafting Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM F693-01(2018)e1 - Standard Practice for Sealing Seams of Resilient Sheet Flooring Products by Use of Liquid Seam Sealers
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F693-01(2018)e1 - Standard Practice for Sealing Seams of Resilient Sheet Flooring Products by Use of Liquid Seam Sealers
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation: F693 − 01 (Reapproved 2018)
Standard Practice for
Sealing Seams of Resilient Sheet Flooring Products by Use
of Liquid Seam Sealers
This standard is issued under the fixed designation F693; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
ε NOTE—Editorial changes were made in 5.2 and 5.3 for clarification in March 2018.
1. Scope 5. Instructions
1.1 This practice covers the instructions and precautions to
5.1 Flooring shall be installed in accordance with the
be observed to ensure satisfactory performance of seams in manufacturer’s instructions.
sheet resilient flooring sealed with liquid seam sealers.
5.2 Particular attention shall be paid to proper cutting of the
1.2 This standard does not purport to address all of the
seams to obtain a net fit so that there are no gaps or overlaps.
safety concerns, if any, associated with its use. It is the
5.3 In making up the seam, care shall be taken to prevent
responsibility of the user of this standard to establish appro-
any flooring adhesive used to bond the floor covering to the
priate safety, health, and environmental practices and deter-
substrate from getting between the cut edges of seam. It is
mine the applicability of regulatory limitations prior to use.
almost impossible to remove such adhesive, and the seam
1.3 This international standard was developed in accor-
sealer will not bond properly in those areas and may result in
dance with internationally recognized principles on standard-
the seam separating and discoloration.
ization established in the Decision on Principles for the
5.4 The proper seam sealer and applicator as recommended
Development of International Standards, Guides and Recom-
by the resilient flooring manufacturer shall be used. Follow the
mendations issued by the World Trade Organization Technical
resilient flooring manufacturer’s instructions as to the method
Barriers to Trade (TBT) Committee.
of application for the specific product being installed.
2. Referenced Documents
5.5 Two-part seam sealers, mixed at a specific ratio per the
2.1 ASTM Standards:
manufacturer’s directions, should be used for a single
F141 Terminology Relating to Resilient Floor Coverings
installation, with any remaining unused sealer properly dis-
posed of.
3. Terminology
5.6 It is important for performance reasons of bonding,
3.1 For definitions of terms used in this practice refer to
adhesion strength, etc., that chemical sealers be appropriately
Terminology F141.
matched to the flooring products they are used to seam. Refer
4. Significance and Use
to the manu
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: F693 − 01 (Reapproved 2012) F693 − 01 (Reapproved 2018)
Standard Practice for
Sealing Seams of Resilient Sheet Flooring Products by Use
of Liquid Seam Sealers
This standard is issued under the fixed designation F693; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
ε NOTE—Editorial changes were made in 5.2 and 5.3 for clarification in March 2018.
1. Scope
1.1 This practice covers the instructions and precautions to be observed to ensure satisfactory performance of seams in sheet
resilient flooring sealed with liquid seam sealers.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2.1 ASTM Standards:
F141 Terminology Relating to Resilient Floor Coverings
3. Terminology
3.1 For definitions of terms used in this practice refer to Terminology F141.
4. Significance and Use
4.1 Seams in some sheet resilient flooring are sealed to prevent openings from forming between cut edges and prevent
penetrations of dirt, liquids, etc., into the seams.
5. Instructions
5.1 Flooring shall be installed in accordance with the manufacturer’s instructions.
5.2 Particular attention shall be paid to proper cutting of the seams to obtain a net fit so that there are no gaps or overlaps.
5.3 In making up the seam, care shall be taken to prevent any flooring adhesive used to bond the floor covering to the substrate
from getting between the cut edges of seam. It is almost impossible to remove such adhesive, and the seam sealer will not bond
properly in those areas and may result in the seam separating and discoloration.
5.4 The proper seam sealer and applicator as recommended by the resilient flooring manufacturer shall be used. Follow the
resilient flooring manufacturer’s instructions as to the method of application for the specific product being installed.
5.5 Two-part seam sealers, mixed at a specific ratio per the manufacturer’s d
...