This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile. Coated glass mat water-resistant gypsum backing panel shall consist of a noncombustible water-resistant gypsum core, surfaced with glass mat, partially or completely embedded in the core, and with a water-resistant coating on one surface. The specimens shall be tested for flexural strength, humidified deflection, core hardness, end hardness, edge hardness, nail pull resistance, water resistance, and surface water absorption. Coated glass mat water-resistant gypsum backing panel shall have surfaces true and free of imperfections that render the panel unfit for its designed use.
SCOPE
1.1 This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in bath and shower areas as a base for the application of ceramic or plastic tile.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Within the text, the SI units are shown in brackets.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1178/C1178M – 08
Standard Specification for
1
Coated Glass Mat Water-Resistant Gypsum Backing Panel
ThisstandardisissuedunderthefixeddesignationC1178/C1178M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 3.2 Definitions of Terms Specific to This Standard:
3.2.1 glass mat, n—a mat of glass fibers with or without a
1.1 This specification covers coated glass mat water-
binder.
resistant gypsum backing panel designed for use on ceilings
3.2.2 edge, n—the bound edge as manufactured.
and walls in bath and shower areas as a base for the application
3.2.3 face, n—the coated surface.
of ceramic or plastic tile.
3.2.4 nominal thickness, n—the manufacturer-stated frac-
1.2 The values stated in either SI units or inch-pound units
tional value of thickness of the gypsum panel product ex-
are to be regarded separately as standard. The values stated in
pressed in decimal value to the nearest one-thousandth (0.001)
each system may not be exact equivalents; therefore, each
of an inch.
system shall be used independently of the other. Combining
values from the two systems may result in non-conformance
4. Materials and Manufacture
with the standard. Within the text, the SI units are shown in
4.1 Coated glass mat water-resistant gypsum backing
brackets.
panel shall consist of a noncombustible water-resistant core,
1.3 The text of this standard references notes and footnotes
essentially gypsum, surfaced with glass mat, partially or
that provide explanatory material. These notes and footnotes
completely embedded in the core, and with a water-resistant
(excluding those in tables and figures) shall not be considered
coating on one surface.
as requirements of the standard.
4.2 Coated glass mat water-resistant gypsum panels, type X
2. Referenced Documents (special fire-resistant) designates glass mat gypsum panels
2
complying with this specification that provide not less than 1-h
2.1 ASTM Standards:
5 3
fire resistance rating for boards ⁄8 in. [15.9 mm] thick or ⁄4-h
C11 TerminologyRelatingtoGypsumandRelatedBuilding
1
fire resistance rating for panels ⁄2 in. [12.7 mm] thick, applied
Materials and Systems
parallel with and on each side of load bearing 2 by 4 wood
C473 Test Methods for Physical Testing of Gypsum Panel
studs spaced 16 in. [406 mm] on center with 6d coated nails,
Products
7 1
1 ⁄8 in. [48-mm] long, 0.0915 in. [2.3 mm] diameter shank, ⁄4
C645 Specification for Nonstructural Steel Framing Mem-
in. [6.4 mm] diameter heads, spaced 7 in. [178 mm] on center
bers
with glass mat gypsum panel joints staggered 16 in. [406 mm]
C1264 Specification for Sampling, Inspection, Rejection,
on each side of the partition and tested in accordance with Test
Certification, Packaging, Marking, Shipping, Handling,
Methods E119.
and Storage of Gypsum Panel Products
E119 Test Methods for Fire Tests of Building Construction
NOTE 1—Consult manufacturers for independent test data on assembly
and Materials
details and fire resistance ratings for other types of construction. See fire
test reports or listings from recognized fire testing laboratories for
3. Terminology
assembly particulars, materials, and ratings.
3.1 Definitions shall be in accordance with Terminology
5. Physical Properties
C11.
5.1 Specimens shall be taken from the samples obtained in
accordance with Specification C1264.
1
This specification is under the jurisdiction of ASTM Committee C11 on
5.2 Specimens shall be tested in accordance with Test
Gypsum and Related Building Materials and Systems and is the direct responsibility
Methods C473.
of Subcommittee C11.01 on Specifications and Test Methods for Gypsum Products.
5.2.1 Flexural Strength—The specimens shall be tested face
Current edition approved Aug. 1, 2008. Published September 2008. Originally
approved in 1991. Last previous edition approved in 2006 as C1178/C 1178M – 06.
up and face down. The average breaking load shall not be less
DOI: 10.1520/C1178_C1178M-08.
than the following:
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1178/C1178M – 08
6.2 Thickness, width, and length shall be determined in
Method B
Load, lbf [N]
accordance with Test Methods C473.
1 1 5
6.2.1 Thickness—The thick
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1178/C1178M–06 Designation: C 1178/C 1178M – 08
Standard Specification for
1
Coated Glass Mat Water-Resistant Gypsum Backing Panel
This standard is issued under the fixed designation C 1178/C 1178M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in
bath and shower areas as a base for the application of ceramic or plastic tile.
1.2The values stated in either inch-pound units or SI (metric) are to be regarded separately as standard. Within the text, the SI
unitsareshowninbrackets.Thevaluesstatedineachsystemshallbeusedindependentlyoftheother.Valuesfromthetwosystems
shall not be combined.
1.1 This specification covers coated glass mat water-resistant gypsum backing panel designed for use on ceilings and walls in
bath and shower areas as a base for the application of ceramic or plastic tile.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard. Within the text, the SI units are shown in brackets.
1.3 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
2. Referenced Documents
2
2.1 ASTM Standards:
C 11 Terminology Relating to Gypsum and Related Building Materials and Systems
C 473 Test Methods for Physical Testing of Gypsum Panel Products
C 645 Specification for Nonstructural Steel Framing Members
C 1264 Specification for Sampling, Inspection, Rejection, Certification, Packaging, Marking, Shipping, Handling, and Storage
of Gypsum Panel Products
E 119 Test Methods for Fire Tests of Building Construction and Materials
3. Terminology
3.1 Definitions shall be in accordance with Terminology C 11.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 glass mat, n—a mat of glass fibers with or without a binder.
3.2.2 edge, n—the bound edge as manufactured.
3.2.3 face, n—the coated surface.
3.2.4 nominal thickness, n—the manufacturer-stated fractional value of thickness of the gypsum panel product expressed in
decimal value to the nearest one-thousandth (0.001) of an inch.
4. Materials and Manufacture
4.1 Coated glass mat water-resistant gypsum backing panel shall consist of a noncombustible water-resistant core, essentially
gypsum, surfaced with glass mat, partially or completely embedded in the core, and with a water-resistant coating on one surface.
4.2 Coated glass mat water-resistant gypsum panels, type X (special fire-resistant) designates glass mat gypsum panels
5 3
complying with this specification that provide not less than 1-h fire resistance rating for boards ⁄8 in. [15.9 mm] thick or ⁄4-h fire
1
resistance rating for panels ⁄2 in. [12.7 mm] thick, applied parallel with and on each side of load bearing 2 by 4 wood studs spaced
7 1
16 in. [406 mm] on center with 6d coated nails, 1 ⁄8 in. [48-mm] long, 0.0915 in. [2.3 mm] diameter shank, ⁄4 in. [6.4 mm]
diameter heads, spaced 7 in. [178 mm] on center with glass mat gypsum panel joints staggered 16 in. [406 mm] on each side of
1
This specification is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of
Subcommittee C11.01 on Specifications and Test Methods for Gypsum Products .
´1
Current edition approved Nov. 1, 2006. Published December 2006. Originally approved in 1991. Last previous edition approved in 2004 as C1178/C1178M–04 .
Current edition approved Aug. 1, 2008. Published September 2008. Originally approved in 1991. Last previous edition approved in 2006 as C 1178/C 1178M – 06.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.