Standard Specification for Steel Wire, Plain, for Concrete Reinforcement

SCOPE
1.1 This specification covers cold-drawn steel wire, as-drawn or galvanized, to be used as such, or in fabricated form, for the reinforcement of concrete, in sizes not less than 2.03 mm (0.080 in.) nominal diameter.
1.2 Supplement S1 describes high-strength wire, which shall be furnished when specifically ordered. It shall be permissible to furnish high-strength wire in place of regular wire if mutually agreed to by the purchaser and the supplier.
1.3 The values stated in either inch-pound units or SI units are to be regarded as standard. Within the text the inch-pound units are shown in parentheses. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values may result in nonconformance with the specification.

General Information

Status
Historical
Publication Date
09-Dec-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM A82-01 - Standard Specification for Steel Wire, Plain, for Concrete Reinforcement
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
American Association State Highway and Transportation Officials
Designation: A 82 – 01 Standard AASHTO No.: M 32
Standard Specification for
1
Steel Wire, Plain, for Concrete Reinforcement
ThisstandardisissuedunderthefixeddesignationA82;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope 2.3 U.S. Federal Standard:
7
Fed. Std. No. 123 Marking for Shipments (CivilAgencies)
1.1 This specification covers cold-drawn steel wire, as-
2.4 Other Standard:
drawn or galvanized, to be used as such, or in fabricated form,
ACI 318 Building Code Requirements for Structural Con-
for the reinforcement of concrete, in sizes not less than 2.03
8
crete
mm (0.080 in.) nominal diameter.
1.2 Supplement S1 describes high-strength wire, which
3. Ordering Information
shall be furnished when specifically ordered. It shall be
3.1 Orders for material to this specification should include
permissible to furnish high-strength wire in place of regular
the following information:
wire if mutually agreed to by the purchaser and the supplier.
3.1.1 Quantity (weight),
1.3 The values stated in either inch-pound units or SI units
3.1.2 Name of material (cold-drawn steel wire for concrete
are to be regarded as standard. Within the text the inch-pound
reinforcement),
units are shown in parentheses. The values stated in each
3.1.3 Wire size number (see Section 8),
system are not exact equivalents; therefore, each system must
3.1.4 Packaging (see Section 15), and
be used independently of the other. Combining values may
3.1.5 ASTM designation and year of issue.
result in nonconformance with the specification.
3.1.6 Special requirements, if any. (See Supplement S1.)
2. Referenced Documents
NOTE 1—A typical ordering description is as follows: 100 000 lb
2.1 ASTM Standards: cold-drawn steel wire for concrete reinforcement, Size No. W5 in 500 lb
secured coils, to ASTM – _________.
A 185 Specification for Steel Welded Wire Reinforcement,
2
Plain, for Concrete
4. Materials and Manufacture
A 370 Test Methods and Definitions for MechanicalTesting
3
4.1 The steel shall be made by one of the following
of Steel Products
processes: open-hearth, electric furnace, or basic-oxygen.
A 641 Specification for Zinc-Coated (Galvanized) Carbon
4
4.2 The wire shall be cold drawn from rods that have been
Steel Wire
hot rolled from billets.
A 700 Practices for Packaging, Marking, and Loading
5
4.3 Unless otherwise specified, the wire shall be supplied
Methods for Steel Products for Domestic Shipment
uncoated. When specified as galvanized, it shall be galvanized
E83 Practice for Verification and Classification of Exten-
6
at finish size.
someters
2.2 U.S. Military Standards:
5. Mechanical Property Requirements
7
MIL-STD-129 Marking for Shipment and Storage
5.1 Tension Tests:
MIL-STD-163 Steel Mill Products Preparation for Ship-
7
5.1.1 When tested as described in Test Methods and Defi-
ment and Storage
nitions A 370, the material, except as specified in 5.1.2, shall
conform to the tensile property requirements in Table 1 based
1
This specification is under the jurisdiction of ASTM Committee A01 on Steel, on nominal area of wire.
Stainless Steel, and RelatedAlloys and is the direct responsibility of Subcommittee
5.1.2 The yield strength shall be determined as described in
A01.05 on Steel Reinforcement.
TestMethodsandDefinitionsA 370atanextensionof0.5 %of
Current edition approved December 10, 2001. Published February 2002. Origi-
e1
gage length. The manufacturer is not required to test for yield
nally published as A 82 – 21 T. Last previous edition A 82 – 97a .
2
Annual Book of ASTM Standards, Vol 01.04.
strength, but is responsible for supplying a product that will
3
Annual Book of ASTM Standards, Vol 01.03.
meet the stipulated limit when tested in conformance with the
4
Annual Book of ASTM Standards, Vol 01.06.
5
Annual Book of ASTM Standards, Vol 01.05.
6
Annual Book of ASTM Standards, Vol 03.01.
7 8
Available from Standardization Documents Order Desk, Bldg. 4, Section D, Available fromAmerican Concrete Institute, P. O. Box 9094, Farmington Hills,
700 Robbins Ave., Philadelphia, PA 19111-5094. MI 48333–9094.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
A 82–01
TABLE 1 Tension Test Requirements TABLE 3 Bend Test Requireme
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.