ASTM E2357-11
(Test Method)Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
SIGNIFICANCE AND USE
This method is intended to simulate the performance of various air barrier materials/accessories when combined into an assembly. Based upon the results of the measurements, this procedure then assigns an air leakage rating for the air barrier assembly.
This method does not purport to establish all criteria necessary for consideration in the selection of an air barrier assembly. The results are intended to be used for comparison purposes and may not represent the field installed performance of the air barrier assembly when installed as part of an air barrier system in a building. However, the results of these tests may be useful in determining the appropriate use of a specified air barrier system assembly.
This method does not purport to establish all criteria necessary for air barrier systems of all construction types. Test Method E2178 provides an air permeance test method for testing of some air barrier materials. Specification E1677 provides a specification for air barrier systems for low-rise framed building walls.
SCOPE
1.1 This test method covers the determination of the air leakage rate of air barrier assemblies that are used in building enclosures. This procedure measures the air leakage of a representative air barrier assembly before and after exposure to specific conditioning cycles and then assigns a rating dependent upon the results. Although this is a laboratory procedure, the method may also be applied to site mockups.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2357 − 11
Standard Test Method for
1
Determining Air Leakage of Air Barrier Assemblies
This standard is issued under the fixed designation E2357; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 3. Terminology
3.1 Definitions:
1.1 This test method covers the determination of the air
3.1.1 For definitions of general terms related to building
leakage rate of air barrier assemblies that are used in building
construction used in this test method, refer to Terminology
enclosures. This procedure measures the air leakage of a
E631.
representative air barrier assembly before and after exposure to
specific conditioning cycles and then assigns a rating depen-
3.2 Definitions of Terms Specific to This Standard:
dent upon the results. Although this is a laboratory procedure,
3.2.1 air barrier—a designated “plane” of reduced air flow
the method may also be applied to site mockups.
between different environments.
1.2 The values stated in SI units are to be regarded as 3.2.2 air barrier accessory—atransitionalcomponentofthe
standard. No other units of measurement are included in this air barrier that provides continuity.
standard.
3.2.3 air barrier assembly—the air barrier materials and
accessories that provide a continuous designated plane to the
1.3 This standard does not purport to address all of the
movement of air through portions of building enclosure assem-
safety concerns, if any, associated with its use. It is the
blies.
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
3.2.4 air barrier material—a primary element that provides
bility of regulatory limitations prior to use.
a continuous barrier to the movement of air.
3.2.5 air barrier system—a combination of air barrier as-
2. Referenced Documents
semblies installed to provide a continuous barrier to the
2
movement of air through building enclosures.
2.1 ASTM Standards:
E283 Test Method for Determining Rate of Air Leakage
3.2.6 air leakage rate—the quantitative measure of air
Through Exterior Windows, Curtain Walls, and Doors
passage through a set surface area of an assembly within a
Under Specified Pressure Differences Across the Speci-
given time period under a pressure differential between the two
men
sides of the assembly.
E330 Test Method for Structural Performance of Exterior
3.2.7 building enclosure—a system of building components
Windows,Doors,SkylightsandCurtainWallsbyUniform
and materials designed and installed in such a manner as to
Static Air Pressure Difference
provide a barrier between different environments, including
E631 Terminology of Building Constructions
dissimilar interior environments.
E783 Test Method for Field Measurement of Air Leakage
3.2.8 continuity—an uninterrupted succession of an air bar-
Through Installed Exterior Windows and Doors
rier materials, accessories and assemblies.
E1677 SpecificationforAirBarrier(AB)MaterialorSystem
3.2.9 durability—the ability of a building component to
for Low-Rise Framed Building Walls
perform its required functions over a period of time within the
E2178 Test Method forAir Permeance of Building Materials
environment to which it is exposed.
3.2.10 negative pressure—air pressure on one side of a
1 building enclosure lower than on the other side.
This test method is under the jurisdiction of ASTM Committee E06 on
Performance of Buildings and is the direct responsibility of Subcommittee E06.41
3.2.11 positive pressure—air pressure on one side of a
on Air Leakage and Ventilation Performance.
building enclosure higher than on the other side.
Current edition approved Sept. 1, 2011. Published October 2011. Originally
approved in 2005. Last previous edition approved in 2005 as E2357–05. DOI:
4. Summary of Test Method
10.1520/E2357-11.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
4.1 This test method establishes a specimen preparation
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
protocol with which an air barrier assembly may be evaluated.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. Atest specimen is constructed and tested in separate pressures.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
E2357 − 11
Up to three specimens are constructed, each additionally 7.2.2 Pressure Measuring Apparatus—A device to measure
representing different field conditions. Specimen 3 is optional t
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:E2357–05 Designation: E2357 – 11
Standard Test Method for
1
Determining Air Leakage of Air Barrier Assemblies
This standard is issued under the fixed designation E2357; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of the air leakage rate of air barrier assemblies that are used in building
enclosures. This procedure measures the air leakage of a representative air barrier assembly before and after exposure to specific
conditioning cycles and then assigns a rating dependent upon the results.Although this is a laboratory procedure, the method may
also be applied to site mockups.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
E283 Test Method for Determining Rate ofAir LeakageThrough ExteriorWindows, CurtainWalls, and Doors Under Specified
Pressure Differences Across the Specimen
E330 Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform StaticAir
Pressure Difference
E631 Terminology of Building Constructions
E783 Test Method for Field Measurement of Air Leakage Through Installed Exterior Windows and Doors
E1677 Specification for an Air Barrier (AB) Material or System for Low-Rise Framed Building Walls
E2178 Test Method for Air Permeance of Building Materials
1
This test method is under the jurisdiction ofASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.41 onAir Leakage
and Ventilation Performance.
Current edition approved Oct. 1, 2005. Published October 2005. DOI: 10.1520/E2357-05.
Current edition approved Sept. 1, 2011. Published October 2011. Originally approved in 2005. Last previous edition approved in 2005 as E2357–05. DOI:
10.1520/E2357-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
E2357 – 11
3. Terminology
3.1 Definitions:
3.1.1 For definitions of general terms related to building construction used in this test method, also refer to Terminology E631.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 air barrier—a designated “plane” of reduced air flow between different environments.
3.2.2 air barrier material—a primary element that provides a continuous barrier to the movement of air.
3.2.3air barrier accessory—a transitional component of the air barrier that provides continuity.
3.2.4
3.2.3 air barrier assembly—the air barrier materials and accessories that provide a continuous designated plane to the
movement of air through portions of building enclosure assemblies.
3.2.4 air barrier material—a primary element that provides a continuous barrier to the movement of air.
3.2.5 air barrier system—a combination of air barrier assemblies installed to provide a continuous barrier to the movement of
air through building enclosures.
3.2.6 air leakage rate—the quantitative measure of air passage through a set surface area of an assembly within a given time
period under a pressure differential between the two sides of the assembly.
3.2.7 building enclosure—a system of building components and materials designed and installed in such a manner as to provide
a barrier between different environments, including dissimilar interior environments.
3.2.8 continuity—an uninterrupted succession of an air barrier materials, accessories and assemblies.
3.2.9 durability—the ability of a building component to perform its required functions over a period of time within the
environment to which it is exposed.
3.2.10 negative pressure—air pressure on one side of a building enclosure lower than on the other
...