ASTM F794-01
(Specification)Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diameter
Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and Fittings Based on Controlled Inside Diameter
SCOPE
1.1 This specification covers requirements for poly(vinyl chloride) (PVC) profile sewer pipe and fittings with integral bell and elastomeric seal joints or plain end pipe with couplings in sizes (4 to 48 in.) based on a controlled inside diameter.
1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 The following safety hazard caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—Pipe and fittings produced to this specification should be installed in accordance with Practice D 2321.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
An American National Standard
Designation: F 794 – 01
Standard Specification for
Poly(Vinyl Chloride) (PVC) Profile Gravity Sewer Pipe and
1
Fittings Based on Controlled Inside Diameter
This standard is issued under the fixed designation F 794; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope D 2412 Test Method for Determination of External Loading
4
Characteristics of Plastic Pipe by Parallel-Plate Loading
1.1 This specification covers requirements for poly(vinyl
D 2444 Test Method for Impact Resistance of Thermoplas-
chloride) (PVC) profile sewer pipe and fittings with integral
4
tic Pipe and Fittings by Means of a Tup (Falling Weight)
bell and elastomeric seal joints or plain end pipe with couplings
D 2855 Practice for Making Solvent-Cemented Joints with
in sizes (4 to 48 in.) based on a controlled inside diameter.
4
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
1.2 The values stated in inch-pound units are to be regarded
D 3034 Specification for Type PSM Poly(Vinyl Chloride)
as the standard. The values given in parentheses are for
4
(PVC) Sewer Pipe and Fittings
information only.
D 3212 Specification for Joints for Drain and Sewer Plastic
1.3 The following safety hazard caveat pertains only to the
4
Pipes Using Flexible Elastomeric Seals
test methods portion, Section 8, of this specification: This
F 402 Practice for Safe Handling of Solvent Cements,
standard does not purport to address all of the safety concerns,
Primers, and Cleaners Used for Joining Thermoplastic Pipe
if any, associated with its use. It is the responsibility of the user
4
and Fittings
of this standard to establish appropriate safety and health
4
F 412 Terminology Relating to Plastic Piping Systems
practices and determine the applicability of regulatory limita-
F 477 Specification for Elastomeric Seals (Gaskets) for
tions prior to use.
4
Joining Plastic Pipe
NOTE 1—Pipe and fittings produced to this specification should be
F 679 Specification for Poly(Vinyl Chloride) (PVC) Large-
installed in accordance with Practice D 2321.
4
Diameter Plastic Gravity Sewer Pipe and Fittings
2.2 American Water Works Association (AWWA) Standard:
2. Referenced Documents
5
AWWA Manual M45 Fiberglass Pipe Design
2.1 ASTM Standards:
2.3 Federal Standard:
D 618 Practice for Conditioning Plastics and Electrical
6
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
2
Insulating Materials for Testing
2.4 Military Standard:
D 1600 Terminology for Abbreviated Terms Relating to
6
MIL-STD-129 Marking for Shipment and Storage
2
Plastics
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
3. Terminology
Compounds and Chlorinated Poly(Vinyl Chloride)
3.1 Definitions—Definitions are in accordance with Termi-
3
(CPVC) Compounds
nology F 412, and abbreviations are in accordance with Ter-
D 2122 Test Method for Determining Dimensions of Ther-
minology D 1600, unless otherwise specified. The abbreviation
4
moplastic Pipe and Fittings
for poly(vinyl chloride) is (PVC).
D 2152 Test Method for Degree of Fusion of Extruded
3.2 Definitions of Terms Specific to This Standard:
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
3.2.1 dual wall corrugated profile (DWCP)gravity sewer
4
Acetone Immersion
pipe—a pipe product consisting of a smooth waterway braced
D 2321 Practice for Underground Installation of Flexible
cumferentially with an external corrugated wall (see Fig. 1)
4
Thermoplastic Sewer Pipe
3.2.2 open profile (OP) gravity sewer pipe—a pipe product
consisting of an essentially smooth waterway braced circum-
ferentially or spirally with outside projections or ribs (see Fig.
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic
2).
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Dec. 10, 2001. Published May 2002. Originally
5
published as F 794 – 83. Last previous edition F 794 – 99. Available from American Water Works Association, 1401 New York Ave. NW,
2
Annual Book of ASTM Standards, Vol 08.01. Suite 640, Washington, DC 20005.
3 6
Annual Book of ASTM Standards, Vol 08.02. Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
4
Annual Book of ASTM Standards, Vol 08.04. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new vers
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.