SIGNIFICANCE AND USE
5.1 Soil placed as engineering fill (embankments, foundation pads, road bases) is compacted to a dense state to obtain satisfactory engineering properties such as, shear strength, compressibility, or permeability. In addition, foundation soils are often compacted to improve their engineering properties. Laboratory compaction tests provide the basis for determining the percent compaction and molding water content needed to achieve the required engineering properties, and for controlling construction to assure that the required compaction and water contents are achieved.
5.2 During design of an engineered fill, shear, consolidation, permeability, or other tests require preparation of test specimens by compacting at some molding water content to some unit weight. It is common practice to first determine the optimum water content (wopt) and maximum dry unit weight (γd,max) by means of a compaction test. Test specimens are compacted at a selected molding water content (w), either wet or dry of optimum (wopt) or at optimum (wopt), and at a selected dry unit weight related to a percentage of maximum dry unit weight (γd,max). The selection of molding water content (w), either wet or dry of optimum (wopt) or at optimum (wopt) and the dry unit weight (γd,max) may be based on past experience, or a range of values may be investigated to determine the necessary percent of compaction.
5.3 Experience indicates that the methods outlined in 5.2 or the construction control aspects discussed in 5.1 are extremely difficult to implement or yield erroneous results when dealing with certain soils. 5.3.1 – 5.3.3 describe typical problem soils, the problems encountered when dealing with such soils and possible solutions for these problems.
5.3.1 Oversize Fraction—Soils containing more than 30 % oversize fraction (material retained on the 3/4-in. (19-mm) sieve) are a problem. For such soils, there is no ASTM test method to control their compaction and very few laboratories are equip...
SCOPE
1.1 These test methods cover laboratory compaction methods used to determine the relationship between molding water content and dry unit weight of soils (compaction curve) compacted in a 4 or 6-in. (101.6 or 152.4-mm) diameter mold with a 5.50-lbf (24.5-N) rammer dropped from a height of 12.0 in. (305 mm) producing a compactive effort of 12 400 ft-lbf/ft3 (600 kN-m/m3).
Note 1: The equipment and procedures are similar as those proposed by R. R. Proctor (Engineering News Record—September 7, 1933) with this one major exception: his rammer blows were applied as “12 inch firm strokes” instead of free fall, producing variable compactive effort depending on the operator, but probably in the range 15 000 to 25 000 ft-lbf/ft3 (700 to 1200 kN-m/m3). The standard effort test (see 3.1.4) is sometimes referred to as the Proctor Test.
1.1.1 Soils and soil-aggregate mixtures are to be regarded as natural occurring fine- or coarse-grained soils, or composites or mixtures of natural soils, or mixtures of natural and processed soils or aggregates such as gravel or crushed rock. Hereafter referred to as either soil or material.
1.2 These test methods apply only to soils (materials) that have 30 % or less by mass of particles retained on the 3/4-in. (19.0-mm) sieve and have not been previously compacted in the laboratory; that is, do not reuse compacted soil.
1.2.1 For relationships between unit weights and molding water contents of soils with 30 % or less by mass of material retained on the 3/4-in. (19.0-mm) sieve to unit weights and molding water contents of the fraction passing 3/4-in. (19.0-mm) sieve, see Practice D4718.
1.3 Three alternative methods are provided. The method used shall be as indicated in the specification for the material being tested. If no method is specified, the choice should be based on the material gradation.
1.3.1 Method A:
1.3.1.1 Mold—4-in. (101.6-mm) diameter.
1.3.1.2 Material—Passing N...
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´2
Designation: D698 − 12
Standard Test Methods for
Laboratory Compaction Characteristics of Soil Using
3 3 1
Standard Effort (12,400 ft-lbf/ft (600 kN-m/m ))
This standard is issued under the fixed designation D698; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1
ε NOTE—Editorial corrections made throughout in January 2014.
2
ε NOTE—Editorially corrected variable for Eq A1.2 in July 2015.
1. Scope* being tested. If no method is specified, the choice should be
based on the material gradation.
1.1 These test methods cover laboratory compaction meth-
1.3.1 Method A:
ods used to determine the relationship between molding water
1.3.1.1 Mold—4-in. (101.6-mm) diameter.
content and dry unit weight of soils (compaction curve)
1.3.1.2 Material—Passing No. 4 (4.75-mm) sieve.
compacted ina4or 6-in. (101.6 or 152.4-mm) diameter mold
1.3.1.3 Layers—Three.
witha5.50-lbf(24.5-N)rammerdroppedfromaheightof12.0
1.3.1.4 Blows per Layer—25.
in. (305 mm) producing a compactive effort of 12400 ft-lbf/
3 3 1.3.1.5 Usage—May be used if 25% or less (see 1.4)by
ft (600 kN-m⁄m ).
mass of the material is retained on the No. 4 (4.75-mm) sieve.
NOTE 1—The equipment and procedures are similar as those proposed
1.3.1.6 Other Usage—If this gradation requirement cannot
by R. R. Proctor (Engineering News Record—September 7, 1933) with
be met, then Method C may be used.
thisonemajorexception:hisrammerblowswereappliedas“12inchfirm
1.3.2 Method B:
strokes”insteadoffreefall,producingvariablecompactiveeffortdepend-
1.3.2.1 Mold—4-in. (101.6-mm) diameter.
ing on the operator, but probably in the range 15000 to 25000
3 3
3
ft-lbf/ft (700 to 1200 kN-m/m ). The standard effort test (see 3.1.4)is
1.3.2.2 Material—Passing ⁄8-in. (9.5-mm) sieve.
sometimes referred to as the Proctor Test.
1.3.2.3 Layers—Three.
1.3.2.4 Blows per Layer—25.
1.1.1 Soilsandsoil-aggregatemixturesaretoberegardedas
naturaloccurringfine-orcoarse-grainedsoils,orcompositesor 1.3.2.5 Usage—May be used if 25% or less (see 1.4)by
3
mass of the material is retained on the ⁄8-in. (9.5-mm) sieve.
mixtures of natural soils, or mixtures of natural and processed
1.3.2.6 Other Usage—If this gradation requirement cannot
soils or aggregates such as gravel or crushed rock. Hereafter
be met, then Method C may be used.
referred to as either soil or material.
1.3.3 Method C:
1.2 These test methods apply only to soils (materials) that
1.3.3.1 Mold—6-in. (152.4-mm) diameter.
3
have 30% or less by mass of particles retained on the ⁄4-in.
3
1.3.3.2 Material—Passing ⁄4-in. (19.0-mm) sieve.
(19.0-mm) sieve and have not been previously compacted in
1.3.3.3 Layers—Three.
the laboratory; that is, do not reuse compacted soil.
1.3.3.4 Blows per Layer—56.
1.2.1 For relationships between unit weights and molding
1.3.3.5 Usage—May be used if 30% or less (see 1.4)by
water contents of soils with 30% or less by mass of material
3
mass of the material is retained on the ⁄4-in. (19.0-mm) sieve.
3
retained on the ⁄4-in. (19.0-mm) sieve to unit weights and
1.3.4 The6-in.(152.4-mm)diametermoldshallnotbeused
3
molding water contents of the fraction passing ⁄4-in. (19.0-
with Method A or B.
mm) sieve, see Practice D4718.
NOTE 2—Results have been found to vary slightly when a material is
1.3 Three alternative methods are provided. The method
tested at the same compactive effort in different size molds, with the
used shall be as indicated in the specification for the material
smaller mold size typically yielding larger values of density/unit weight
2
(1, pp. 21+).
1.4 If the test specimen contains more than 5% by mass of
1
These Test Methods are under the jurisdiction of ASTM Committee D18 on oversize fraction (coarse fraction) and the material will not be
SoilandRockandarethedirectresponsibilityofSubcommitteeD18.03onTexture,
Plasticity and Density Characteristics of Soils.
Current edition approved May 1, 2012. Published June 2012. Originally
ε1 2
approved in 1942. Last previous edition approved in 2000 as D698 – 07 . DOI: Theboldfacenumbersinparenthesesrefertothelistofreferencesattheendof
10.1520/D0698-12E01. this standard.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
´2
D698 − 12
included in the test, corrections must be made to the unit mass C136Test Method for Sieve Analysis of Fine and Coarse
and molding water content of the specimen o
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´2 ´2
Designation: D698 − 12 D698 − 12
Standard Test Methods for
Laboratory Compaction Characteristics of Soil Using
3 3 1
Standard Effort (12 400 ft-lbf/ft (600 kN-m/m ))
This standard is issued under the fixed designation D698; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1
ε NOTE—Editorial corrections made throughout in January 2014.
2
ε NOTE—Editorially corrected variable for Eq A1.2 in July 2015.
1. Scope*
1.1 These test methods cover laboratory compaction methods used to determine the relationship between molding water content
and dry unit weight of soils (compaction curve) compacted in a 4 or 6-in. (101.6 or 152.4-mm) diameter mold with a 5.50-lbf
3
(24.5-N) rammer dropped from a height of 12.0 in. (305 mm) producing a compactive effort of 12 400 ft-lbf/ft (600
3
kN-m/mkN-m ⁄m ).
NOTE 1—The equipment and procedures are similar as those proposed by R. R. Proctor (Engineering News Record—September 7, 1933) with this one
major exception: his rammer blows were applied as “12 inch firm strokes” instead of free fall, producing variable compactive effort depending on the
3 3
operator, but probably in the range 15 000 to 25 000 ft-lbf/ft (700 to 1200 kN-m/m ). The standard effort test (see 3.1.4) is sometimes referred to as the
Proctor Test.
1.1.1 Soils and soil-aggregate mixtures are to be regarded as natural occurring fine- or coarse-grained soils, or composites or
mixtures of natural soils, or mixtures of natural and processed soils or aggregates such as gravel or crushed rock. Hereafter referred
to as either soil or material.
3
1.2 These test methods apply only to soils (materials) that have 30 % or less by mass of particles retained on the ⁄4-in.
(19.0-mm) sieve and have not been previously compacted in the laboratory; that is, do not reuse compacted soil.
1.2.1 For relationships between unit weights and molding water contents of soils with 30 % or less by mass of material retained
3 3
on the ⁄4-in. (19.0-mm) sieve to unit weights and molding water contents of the fraction passing ⁄4-in. (19.0-mm) sieve, see
Practice D4718.
1.3 Three alternative methods are provided. The method used shall be as indicated in the specification for the material being
tested. If no method is specified, the choice should be based on the material gradation.
1.3.1 Method A:
1.3.1.1 Mold—4-in. (101.6-mm) diameter.
1.3.1.2 Material—Passing No. 4 (4.75-mm) sieve.
1.3.1.3 Layers—Three.
1.3.1.4 Blows per Layer—25.
1.3.1.5 Usage—May be used if 25 % or less (see 1.4) by mass of the material is retained on the No. 4 (4.75-mm) sieve.
1.3.1.6 Other Usage—If this gradation requirement cannot be met, then Method C may be used.
1.3.2 Method B:
1.3.2.1 Mold—4-in. (101.6-mm) diameter.
3
1.3.2.2 Material—Passing ⁄8-in. (9.5-mm) sieve.
1.3.2.3 Layers—Three.
1.3.2.4 Blows per Layer—25.
3
1.3.2.5 Usage—May be used if 25 % or less (see 1.4) by mass of the material is retained on the ⁄8-in. (9.5-mm) sieve.
1.3.2.6 Other Usage—If this gradation requirement cannot be met, then Method C may be used.
1.3.3 Method C:
1
These Test Methods are under the jurisdiction of ASTM Committee D18 on Soil and Rock and are the direct responsibility of Subcommittee D18.03 on Texture, Plasticity
and Density Characteristics of Soils.
ε1
Current edition approved May 1, 2012. Published June 2012. Originally approved in 1942. Last previous edition approved in 2000 as D698 – 07 . DOI:
10.1520/D0698-12E01.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
´2
D698 − 12
1.3.3.1 Mold—6-in. (152.4-mm) diameter.
3
1.3.3.2 Material—Passing ⁄4-in. (19.0-mm) sieve.
1.3.3.3 Layers—Three.
1.3.3.4 Blows per Layer—56.
3
1.3.3.5 Usage—May be used if 30 % or less (see 1.4) by mass of the material is retained on the ⁄4-in. (19.0-mm) sieve.
1.3.4 The 6-in. (152.4-mm) diameter mold shall not be used with Method A or B.
NOTE 2—Results have been found to vary slightly when a material is tested at the same compactive effort in different size molds, with the smaller mold
2
size typically yielding larger values of density/unit weight (1, p
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.