Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

SIGNIFICANCE AND USE
Sound transmission loss as defined in Terminology C 634, refers to the response of specimens exposed to a diffuse incident sound field, and this is the test condition approached by this laboratory test method. The test results are therefore most directly relevant to the performance of similar specimens exposed to similar sound fields. They provide, however, a useful general measure of performance for the variety of sound fields to which a partition or element may typically be exposed.
This test method is not intended for field tests. Field tests should be performed according to Test Method E 336.
SCOPE
1.1 This test method covers the laboratory measurement of airborne sound transmission loss of building partitions such as walls of all kinds, operable partitions, floor-ceiling assemblies, doors, windows, roofs, panels, and other space-dividing elements.
1.2 Laboratory Accreditation—A procedure for accrediting a laboratory for performing this test method is given in Annex A3.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Mar-2004
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E90-04 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E90-04 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
English language
15 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E 90 – 04
Standard Test Method for
Laboratory Measurement of Airborne Sound Transmission
1
Loss of Building Partitions and Elements
ThisstandardisissuedunderthefixeddesignationE90;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
INTRODUCTION
Thistestmethodispartofasetforevaluatingthesound-insulatingpropertiesofbuildingelements.
It is designed to measure the transmission of sound through a partition or partition element in a
laboratory. Others in the set cover the measurement of sound isolation in buildings (Test Method
E336),thelaboratorymeasurementofimpactsoundtransmissionthroughfloors(TestMethodE492),
the measurement of impact sound transmission in buildings (Test Method E1007), the measurement
of sound transmission through building facades and facade elements (Guide E966), the measurement
of sound transmission through a common plenum between two rooms (Test Method E1414), a quick
method for the determination of airborne sound isolation in multiunit buildings (Practice E597), and
the measurement of sound transmission through door panels and systems (Test Method E1408).
1. Scope E336 Test Method for Measurement of Airborne Sound
Insulation in Buildings
1.1 This test method covers the laboratory measurement of
E413 Classification for Rating Sound Insulation
airborne sound transmission loss of building partitions such as
E492 Test Method for Laboratory Measurement of Impact
walls of all kinds, operable partitions, floor-ceiling assemblies,
Sound Transmission Through Floor-Ceiling Assemblies
doors, windows, roofs, panels, and other space-dividing ele-
Using the Tapping Method
ments.
E597 Practice for Determining a Single-Number Rating of
1.2 Laboratory Accreditation—A procedure for accrediting
Airborne Sound Isolation for Use in Multiunit Building
a laboratory for performing this test method is given inAnnex
Specifications
A3.
E966 Guide for Field Measurement of Airborne Sound
1.3 This standard does not purport to address all of the
Insulation of Building Facades and Facade Elements
safety concerns, if any, associated with its use. It is the
E1007 Test Method for Field Measurement of Tapping
responsibility of the user of this standard to establish appro-
Machine Impact Sound Transmission through Floor-
priate safety and health practices and determine the applica-
Ceiling Assemblies and Associated Support Structures
bility of regulatory limitations prior to use.
E1289 Specification for Reference Specimen for Sound
2. Referenced Documents Transmission Loss
2
E1332 Classification for Determination of Outdoor-Indoor
2.1 ASTM Standards:
Transmission Class
C634 Terminology Relating to Environmental Acoustics
E1375 Test Method for Measuring the Interzone Attenua-
tion of Furniture Panels Used as Acoustical Barriers
1
ThistestmethodisunderthejurisdictionofASTMCommitteeE33onBuilding E1408 Test Method for Laboratory Measurement of the
and Environmental Acoustics and is the direct responsibility of Subcommittee
Sound Transmission Loss of Door Panels and Door Sys-
E33.03 on Sound Transmission.
tems
Current edition approved April 1, 2004. Published May 2004. Originally
E1414 Test Method for Airborne Sound Attenuation Be-
approved in 1955. Last previous edition approved 2002 E90–02.
2
Annual Book of ASTM Standards, Vol 04.06.
tween Rooms Sharing a Common Ceiling Plenum
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
E2235 Test Method for Determination of Decay Rates for
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Use in Sound Insulation Test Methods
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. 2.2 ANSI Standards:
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E90–04
3
S1.4 Specification for Sound-Level Meters 3.2 Definitions of Terms Specific to This Standard:
2
S1.6 Standard Preferred Frequencies, Frequency Levels, 3.2.1 sound absorption, A, [L ]—of a room, in a specified
3
and Band Numbers for Acoustical Measurements frequency band, the hypothetical area of a totally absorbing
S1.10 Pressure Calibration of Laboratory Standard Pressure surface without diffraction effects which, if it were the only
3
Microphones absorbing element in the room, would give the same sound
S1.11 Specification for Octave-Band and Fractional- decay rate as the room under consideration.
3
Octave-Band Analog and Digital Filters
4. Summary of Test Method
S12.
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:E90–02 Designation: E 90 – 04
Standard Test Method for
Laboratory Measurement of Airborne Sound Transmission
1
Loss of Building Partitions and Elements
ThisstandardisissuedunderthefixeddesignationE90;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
INTRODUCTION
Thistestmethodispartofasetforevaluatingthesound-insulatingpropertiesofbuildingelements.
It is designed to measure the transmission of sound through a partition or partition element in a
laboratory. Others in the set cover the measurement of sound isolation in buildings (Test Method
E336),thelaboratorymeasurementofimpactsoundtransmissionthroughfloors(TestMethodE492),
the measurement of impact sound transmission in buildings (Test Method E1007), the measurement
of sound transmission through building facades and facade elements (Guide E966), the measurement
of sound transmission through a common plenum between two rooms (Test Method E1414), a quick
method for the determination of airborne sound isolation in multiunit buildings (Practice E597), and
the measurement of sound transmission through door panels and systems (Test Method E1408).
1. Scope
1.1 Thistestmethodcoversthelaboratorymeasurementofairbornesoundtransmissionlossofbuildingpartitionssuchaswalls
of all kinds, operable partitions, floor-ceiling assemblies, doors, windows, roofs, panels, and other space-dividing elements.
1.2 Laboratory Accreditation—Aprocedure for accrediting a laboratory for performing this test method is given inAnnexA3.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C634634 Terminology Relating to Environmental Acoustics
E336 Test Method for Measurement of Airborne Sound Insulation in Buildings
E413 Classification for Rating Sound Insulation
E492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-CeilingAssemblies Using the
Tapping Method
E597 Practice for Determining a Single-Number Rating of Airborne Sound Isolation for Use in Multiunit Building
Specifications
E966 Guide for Field Measurement of Airborne Sound Insulation of Building Facades and Facade Elements
E1007 TestMethodforFieldMeasurementofTappingMachineImpactSoundTransmissionthroughFloor-CeilingAssemblies
and Associated Support Structures
E1289 Specification for Reference Specimen for Sound Transmission Loss
E1332 Classification for Determination of Outdoor-Indoor Transmission Class
E1375 Test Method for Measuring the Interzone Attenuation of Furniture Panels Used as Acoustical Barriers
E1408 Test Method for Laboratory Measurement of the Sound Transmission Loss of Door Panels and Door Systems
1
This test method is under the jurisdiction ofASTM Committee E33 on Building and EnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.03
on Sound Transmission.
Current edition approved May 10, 2002. Published August 2002. Originally published as E90–55. Last previous edition E90–99.
Current edition approved April 1, 2004. Published May 2004. Originally approved in 1955. Last previous edition approved 2002 E90–02.
2
Annual Book of ASTM Standards, Vol 04.06.
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E90–04
2
E1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum Test Method for
Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
E2235 Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods
2.2 ANSI Standards:
3
S1.4 Specification for Sound-Level Meters
3
S1.6 Standard Preferred Frequencies, Frequency Levels, and Band Numbers for Acoustical Measurements
3
S1.10 Pressure Calibration of Laboratory Standard Pr
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.