Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines

SIGNIFICANCE AND USE
5.1 This is not a routine test. The values recorded are applicable only to the pipe being tested and at the time of testing.
SCOPE
1.1 This practice covers procedures for testing installed non-perforated, gasketed corrugated high-density polyethylene (HDPE) and corrugated polypropylene (PP) pipelines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity via the level of leakage of the installed materials, construction procedures and installation qualityvia the level of leakage. Pipe to be tested under this practice shall include corrugated HDPE and PP drainage pipe meeting the requirements of Specifications F2306/F2306M, F2763, F2764/F2764M, F2881/F2881M and F2947/F2947M.
Note 1: The performance criteria specified in this standard may be used for other plastic pipe products. The engineer, however, must assess if the testing procedures are adequate for the particular material and installation being considered.
Note 2: The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 600 mm (24 in.) diameter or larger, may be accepted by visual inspection when testing for infiltration.  
1.2 This test method shall be performed on lines after all connections and service laterals have been plugged and braced adequately to withstand the test pressures. The time between completion of the backfill operations and testing shall be specified by the approving authority.  
1.3 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Nov-2021
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F2487-21 - Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F2487-21 - Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2487 −21 An American National Standard
Standard Practice for
Infiltration and Exfiltration Acceptance Testing of Installed
Corrugated High Density Polyethylene and Polypropylene
1
Pipelines
This standard is issued under the fixed designation F2487; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
1.1 This practice covers procedures for testing installed
mendations issued by the World Trade Organization Technical
non-perforated, gasketed corrugated high-density polyethylene
Barriers to Trade (TBT) Committee.
(HDPE) and corrugated polypropylene (PP) pipelines using
either water infiltration or exfiltration acceptance limits to
2. Referenced Documents
demonstrate the integrity via the level of leakage of the
2
2.1 ASTM Standards:
installed materials, construction procedures and installation
D3212 Specification for Joints for Drain and Sewer Plastic
qualityvia the level of leakage. Pipe to be tested under this
Pipes Using Flexible Elastomeric Seals
practice shall include corrugated HDPE and PP drainage pipe
F412 Terminology Relating to Plastic Piping Systems
meeting the requirements of Specifications F2306/F2306M,
F2306/F2306M Specification for 300 mm to 1500 mm [12
F2763, F2764/F2764M, F2881/F2881M and F2947/F2947M.
in. to 60 in.] Annular Corrugated Profile-Wall Polyethyl-
NOTE 1—The performance criteria specified in this standard may be
ene (PE) Pipe and Fittings for Non-Pressure Gravity-Flow
used for other plastic pipe products.The engineer, however, must assess if
Storm Sewer and Subsurface Drainage Applications
the testing procedures are adequate for the particular material and
F2763 Specification for 12 to 60 in. [300 to 1500 mm] Dual
installation being considered.
and Triple Profile-Wall Polyethylene (PE) Pipe and Fit-
NOTE 2—The user of this practice is advised that test criteria presented
in this practice are similar to those in general use. Pipe, 600 mm (24 in.) tings for Sanitary Sewer Applications
diameter or larger, may be accepted by visual inspection when testing for
F2764/F2764M Specification for 6 to 60 in. [150 to 1500
infiltration.
mm] Polypropylene (PP) Corrugated Double and Triple
1.2 This test method shall be performed on lines after all
Wall Pipe and Fittings for Non-Pressure Sanitary Sewer
connections and service laterals have been plugged and braced
Applications
adequately to withstand the test pressures. The time between
F2881/F2881M Specification for 12 to 60 in. [300 to 1500
completion of the backfill operations and testing shall be
mm] Polypropylene (PP) Dual Wall Pipe and Fittings for
specified by the approving authority.
Non-Pressure Storm Sewer Applications
F2947/F2947M Specification for 150 to 1500 mm [6 to 60
1.3 Units—The values stated in SI units are to be regarded
in.] Annular Corrugated Profile-Wall Polyethylene (PE)
as standard. The values given in parentheses after SI units are
Pipe and Fittings for Sanitary Sewer Applications
provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the
3. Terminology
safety concerns, if any, associated with its use. It is the
3.1 Definitions—For definitions of terms relating to plastic
responsibility of the user of this standard to establish appro-
pipe, see Terminology F412.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use. 4. Summary of Practice
1.5 This international standard was developed in accor-
4.1 Determine the groundwater conditions surrounding the
dance with internationally recognized principles on standard-
section of pipeline to be tested and select the type of test to be
conducted.
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic
2
Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Dec. 1, 2021. Published February 2022. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approvedin2006.Lastpreviouseditionapprovedin2017asF2487–13(2017).DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F2487-21. the AST
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F2487 − 13 (Reapproved 2017) F2487 − 21 An American National Standard
Standard Practice for
Infiltration and Exfiltration Acceptance Testing of Installed
Corrugated High Density Polyethylene and Polypropylene
1,21
Pipelines
This standard is issued under the fixed designation F2487; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope*
1.1 This practice covers procedures for testing installed non-perforated, gasketed corrugated high-density polyethylene (HDPE)
and corrugated polypropylene (PP) pipelines using either water infiltration or exfiltration acceptance limits to demonstrate the
integrity via the level of leakage of the installed materials, construction procedures and installation qualityvia the level of leakage.
Pipe to be tested under this practice shall include corrugated HDPE and PP drainage pipe meeting the requirements of AASHTO
M 252, AASHTO M 294 and Specifications F2306/F2306M, F2736, F2762, F2763, F2764/F2764M, F2881/F2881M and
F2947/F2947M.
NOTE 1—The performance criteria specified in this standard may be used for other plastic pipe products. The engineer, however, must assess if the testing
procedures are adequate for the particular material and installation being considered.
NOTE 2—The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 600-mm (24-in.)600 mm
(24 in.) diameter or larger, may be accepted by visual inspection when testing for infiltration.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are mathematical conversions to
inch-pounds, which are provided for informational purposes only and are not considered standard.
1.2 This test method shall be performed on lines after all connections and service laterals have been plugged and braced adequately
to withstand the test pressures. The time between completion of the backfill operations and testing shall be specified by the
approving authority.
1.3 Units—The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided
for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of
regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1
This practice is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.
Current edition approved Nov. 1, 2017Dec. 1, 2021. Published November 2017February 2022. Originally approved in 2006. Last previous edition approved in 20122017
as F2487–06(2012).F2487–13(2017). DOI: 10.1520/F2487-13.10.1520/F2487-21.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2487 − 21
2. Referenced Documents
2
2.1 ASTM Standards:
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
F412 Terminology Relating to Plastic Piping Systems
F2306/F2306M Specification for 300 mm to 1500 mm [12 in. to 60 in.] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe
and Fittings for Non-Pressure Gravity-Flow Storm Sewer and Subsurface Drainage Applications
F2736 Specification for 6 to 30 in. (152 To 762 mm) Polypropylene (PP) Corrugated Single Wall Pipe And Double Wall Pipe
4
(Withdrawn 2018)
F2762 Specification for 12 to 30 in. (300 to 750 mm) Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for
4
Sanitary Sewer Applications (Withdrawn 2016)
F2763 Specification for 12 to 60 in. [300 to 1500 mm] Dual and Trip
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.