Standard Specification for Glass Mat Gypsum Panels

ABSTRACT
This specification covers the glass mat gypsum panels. Glass mat interior gypsum panel, designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration. Glass mat coreboard gypsum panel, and glass mat shaftliner gypsum panel, designed for use as a base in multilayer systems or as gypsum studs or cores in semisolid or solid gypsum board partitions, or in shaftwall assemblies. Glass mat water-resistant gypsum panel, designed to be used as a base for the application of ceramic or plastic tile on walls or ceilings. Glass mat gypsum panel shall consist of a noncombustible core, gypsum, surfaced with glass mat partially or completely embedded in the core. Flexural strength, humidified deflection, null pull resistance, water resistance, and surface water absorption and shall conform to the physical property requirements of the materials specified.
SCOPE
1.1 This specification covers the glass mat gypsum panels described in 1.1.1 – 1.1.3.  
1.1.1 Glass mat interior gypsum panel, designed for use on walls, ceilings, or partitions and that affords a surface suitable to receive decoration.  
1.1.2 Glass mat coreboard gypsum panel, and glass mat shaftliner gypsum panel, designed for use as a base in multilayer systems or as gypsum studs or cores in semisolid or solid gypsum board partitions, or in shaftwall assemblies.  
1.1.3 Glass mat water-resistant gypsum panel, designed to be used as a base for the application of ceramic or plastic tile on walls or ceilings. This product is also suitable for decoration. (This is distinct from a coated glass mat water-resistant gypsum panel ASTM 1178.)  
1.2 Specifications applicable to all glass mat gypsum panels are located in Sections 1 – 4 and 8 – 10. Specifications applicable to specific glass mat gypsum panels are located in the following sections:
Section  
Glass mat interior gypsum panel  
5  
Glass mat coreboard gypsum panel,
and glass mat shaftliner
gypsum panel  
6  
Glass mat water-resistant gypsum panel  
7
1.3 The values stated in either inch-pound units or SI (metric) are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems shall not be combined.

General Information

Status
Historical
Publication Date
30-Sep-2013
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C1658/C1658M-13 - Standard Specification for Glass Mat Gypsum Panels
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1658/C1658M-13 - Standard Specification for Glass Mat Gypsum Panels
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1658/C1658M −13
Standard Specification for
1
Glass Mat Gypsum Panels
This standard is issued under the fixed designation C1658/C1658M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
1.1 This specification covers the glass mat gypsum panels 2.1 ASTM Standards:
described in 1.1.1 – 1.1.3. C11 Terminology Relating to Gypsum and Related Building
1.1.1 Glass mat interior gypsum panel, designed for use on Materials and Systems
walls, ceilings, or partitions and that affords a surface suitable C22 Specification for Gypsum
to receive decoration. C473 Test Methods for Physical Testing of Gypsum Panel
1.1.2 Glass mat coreboard gypsum panel, and glass mat Products
shaftliner gypsum panel, designed for use as a base in C645 Specification for Nonstructural Steel Framing Mem-
multilayer systems or as gypsum studs or cores in semisolid or bers
solid gypsum board partitions, or in shaftwall assemblies. C1264 Specification for Sampling, Inspection, Rejection,
1.1.3 Glass mat water-resistant gypsum panel, designed to Certification, Packaging, Marking, Shipping, Handling,
be used as a base for the application of ceramic or plastic tile and Storage of Gypsum Panel Products
on walls or ceilings. This product is also suitable for decora- E84 Test Method for Surface Burning Characteristics of
tion. (This is distinct from a coated glass mat water-resistant Building Materials
gypsum panel ASTM 1178.) E119 Test Methods for Fire Tests of Building Construction
and Materials
1.2 Specifications applicable to all glass mat gypsum panels
are located in Sections 1–4 and 8–10. Specifications
3. Terminology
applicable to specific glass mat gypsum panels are located in
3.1 Definitions used in this specification shall be in accor-
the following sections:
dance with Terminology C11.
Section
Glass mat interior gypsum panel 5
3.2 Definitions of Terms Specific to This Standard:
Glass mat coreboard gypsum 6
3.2.1 glass mat, n—a mat of glass fibers with or without a
panel,
binder.
and glass mat shaftliner
gypsum panel
Glass mat water-resistant gypsum 7
4. Materials and Manufacture
panel
4.1 Glass mat gypsum panel shall consist of a noncombus-
1.3 The values stated in either inch-pound units or SI
tible core, essentially gypsum complying with Specification
(metric) are to be regarded separately as standard. Within the
C22, surfaced with glass mat partially or completely embedded
text, the SI units are shown in brackets. The values stated in
in the core.
each system shall be used independent of the other. Values
4.1.1 Glass mat interior gypsum panel shall consist of a
from the two systems shall not be combined.
noncombustible core, essentially gypsum complying with
1.4 This international standard was developed in accor-
Specification C22, surfaced on both the face and back with
dance with internationally recognized principles on standard-
glass mat partially or completely embedded into the core.
ization established in the Decision on Principles for the
4.1.2 Glass mat coreboard gypsum panel, and glass mat
Development of International Standards, Guides and Recom-
shaftliner gypsum panel shall be either a single panel or
mendations issued by the World Trade Organization Technical
composed of two factory-laminated gypsum panels to provide
Barriers to Trade (TBT) Committee.
up to 1 in. [25.4 mm] total nominal thickness, surfaced on both
face and back with glass mat partially or completely embedded
into the core.
1
This test method is under the jurisdiction ofASTM Committee C11 on Gypsum
and Related Building Materials and Systems and is the direct responsibility of
2
Subcommittee C11.01 on Specifications and Test Methods for Gypsum Products. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Oct. 1, 2013. Published October 2013. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2006. Last previous edition approved in 2012 as C1658/C1658M – 12. Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/C1658_C1658M-13. the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1658/C1658M − 13
4.1.3 Glass mat gypsum water-resistant panel shall consist 4.5.5 Tapered Edge Depth—The average thickness of the
of a noncombustible water-resistant core, essentially gypsum edge of recessed or tapered
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1658/C1658M − 12 C1658/C1658M − 13
Standard Specification for
1
Glass Mat Gypsum Panels
This standard is issued under the fixed designation C1658/C1658M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Scope*
1.1 This specification covers the glass mat gypsum panels described in 1.1.1 – 1.1.3.
1.1.1 Glass mat interior gypsum panel, designed for use on walls, ceilings, or partitions and that affords a surface suitable to
receive decoration.
1.1.2 Glass mat coreboard gypsum panel, and glass mat shaftliner gypsum panel, designed for use as a base in multilayer
systems or as gypsum studs or cores in semisolid or solid gypsum board partitions, or in shaftwall assemblies.
1.1.3 Glass mat water-resistant gypsum panel, designed to be used as a base for the application of ceramic or plastic tile on walls
or ceilings. This product is also suitable for decoration. (This is distinct from a coated glass mat water-resistant gypsum panel
ASTM 1178.)
1.2 Specifications applicable to all glass mat gypsum panels are located in Sections 1 – 4 and 8 – 10. Specifications applicable
to specific glass mat gypsum panels are located in the following sections:
Section
Glass mat interior gypsum panel 5
Glass mat coreboard gypsum 6
panel,
and glass mat shaftliner
gypsum panel
Glass mat water-resistant gypsum 7
panel
1.3 The values stated in either inch-pound units or SI (metric) are to be regarded separately as standard. Within the text, the SI
units are shown in brackets. The values stated in each system shall be used independent of the other. Values from the two systems
shall not be combined.
2. Referenced Documents
2
2.1 ASTM Standards:
C11 Terminology Relating to Gypsum and Related Building Materials and Systems
C22 Specification for Gypsum
C473 Test Methods for Physical Testing of Gypsum Panel Products
C645 Specification for Nonstructural Steel Framing Members
C1264 Specification for Sampling, Inspection, Rejection, Certification, Packaging, Marking, Shipping, Handling, and Storage of
Gypsum Panel Products
E84 Test Method for Surface Burning Characteristics of Building Materials
E119 Test Methods for Fire Tests of Building Construction and Materials
3. Terminology
3.1 Definitions used in this specification shall be in accordance with Terminology C11.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 glass mat, n—a mat of glass fibers with or without a binder.
1
This test method is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of
Subcommittee C11.01 on Specifications and Test Methods for Gypsum Products.
Current edition approved Jan. 15, 2012Oct. 1, 2013. Published March 2012October 2013. Originally approved in 2006. Last previous edition approved in 20062012 as
E841 – 06.E841 – 12. DOI: 10.1520/C1658_C1658M-12.10.1520/C1658_C1658M-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1658/C1658M − 13
4. Materials and Manufacture
4.1 Glass mat gypsum panel shall consist of a noncombustible core, essentially gypsum, gypsum complying with Specification
C22, surfaced with glass mat partially or completely embedded in the core.
4.1.1 Glass mat interior gypsum panel shall consist of a noncombustible core, essentially gypsum, gypsum complying with
Specification C22, surfaced on both the face and back with glass mat partially or completely embedded into the core.
4.1.2 Glass mat coreboard gypsum panel, and glass mat shaftliner gypsum panel shall be either a single panel or composed of
two factory-laminated gypsum panels to provide up to 1 in. [25.4 mm] total nominal thickness, surfaced on both face and back
with glass mat partially or completely embedded into the core.
4.1.3 Glass mat gypsum water-resistant panel shall consist of a noncombustible water-resistant core, essentially gypsum,
gypsum complying with Specification C22,
...

Questions, Comments and Discussion