ASTM F820-11
(Test Method)Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems
Standard Test Method for Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems
SIGNIFICANCE AND USE
The test results allow the comparison of the maximum air power available when no dirt has been introduced into the vacuum cleaning system, that is, a completely clean filter or an empty, clean dirt container.
SCOPE
1.1 This test method covers procedures for determining air performance characteristics of household central vacuum cleaning systems, which use a flexible cleaning hose assembly and incorporates a series universal motor(s). This test method does not apply to the carpet cleaning mode of operation where dirt or debris is involved.
1.2 These tests and calculations include determination of suction, airflow, air power, maximum air power, and input power under standard operating conditions (see Note 0).Note 0
For more information on air performance characteristics, see Refs ().
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Note 0.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F820 − 11 AnAmerican National Standard
Standard Test Method for
Measuring Air Performance Characteristics of Central
1
Vacuum Cleaning Systems
ThisstandardisissuedunderthefixeddesignationF820;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope eters with Low-Hazard Precision Liquids
F431 Specification for Air Performance Measurement Ple-
1.1 This test method covers procedures for determining air
num Chamber for Vacuum Cleaners
performance characteristics of household central vacuum
4
2.2 AMCA Standard:
cleaning systems, which use a flexible cleaning hose assembly
210–85 Laboratory Methods of Testing Fans for Rating
and incorporates a series universal motor(s). This test method
5
does not apply to the carpet cleaning mode of operation where
2.3 IEC Standard:
dirt or debris is involved.
IEC 60312 Ed 3.2 Vacuum Cleaners for Household Use—
Methods of Measuring the Performance
1.2 These tests and calculations include determination of
suction, airflow, air power, maximum air power, and input
3. Terminology
power under standard operating conditions (see Note 1).
3.1 Definitions:
NOTE 1—For more information on air performance characteristics, see
2
3.1.1 airpower,AP,W,n—in a vacuum cleaner, the net time
Refs (1-6).
rate of work performed by an air stream while expending
1.3 The values stated in inch-pound units are to be regarded
energy to produce an airflow by a vacuum cleaner under
as the standard. The values given in parentheses are provided
specified air resistance conditions.
for information only.
3.1.2 automatic bleed valve, n—any device a part of a
1.4 This standard does not purport to address all of the
vacuum cleaner’s design, which automatically introduces an
safety concerns, if any, associated with its use. It is the
intentional leak within the vacuum cleaner’s system when
responsibility of the user of this standard to establish appro-
manufacturer specified conditions are met.
priate safety and health practices and determine the applica-
3.1.3 corrected airflow, Q, cfm, n—in a vacuum cleaner, the
bility of regulatory limitations prior to use. A specific precau-
volume of air movement per unit of time under standard
tionary statement is given in Note 4.
atmospheric conditions.
2. Referenced Documents
3.1.4 input power, W, n—the rate at which electrical energy
3
is absorbed by a vacuum cleaner.
2.1 ASTM Standards:
E1 Specification for ASTM Liquid-in-Glass Thermometers
3.1.5 model, n—the designation of a group of vacuum
E177 Practice for Use of the Terms Precision and Bias in
cleaners having the same mechanical and electrical construc-
ASTM Test Methods
tion with only cosmetic or nonfunctional differences.
E691 Practice for Conducting an Interlaboratory Study to
3.1.6 population, n—the total of all units of a particular
Determine the Precision of a Test Method
model vacuum cleaner being tested.
E2251 Specification for Liquid-in-Glass ASTM Thermom-
3.1.7 repeatability limit (r), n—the value below which the
absolutedifferencebetweentwoindividualtestresultsobtained
1
This test method is under the jurisdiction ofASTM Committee F11 on Vacuum under repeatability conditions may be expected to occur with a
Cleaners and is the direct responsibility of Subcommittee F11.22 on Air Perfor-
probability of approximately 0.95 (95 %).
mance.
3.1.8 reproducibilitylimit(R),n—thevaluebelowwhichthe
Current edition approved Nov. 1, 2011. Published December 2011. Originally
approved in 1988. Last previous edition approved in 2006 as F820 – 06. DOI:
absolute difference between two test results obtained under
10.1520/F0820-11.
2
The boldface numbers in parentheses refer to the list of references at the end of
this standard.
3 4
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from Air Movement and Control Association, Inc., 30 West Univer-
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM sity Dr., Arlington Heights, IL 60004–1893.
5
Standards volume information, refer to the standard’s Document Summary page on Available from the IEC Web store, webstore.iec.ch, or American National
the ASTM website. Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F820 − 11
reproducibility conditions may be expected to occur with a 5.5 Barometer, with an accuracy of 60.05 in. (1.27 mm) of
probability of approximately 0.95 (95 %). mercury, capable of measuring and displaying absolute baro-
m
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F820–06 Designation: F820 – 11
Standard Test Method for
Measuring Air Performance Characteristics of Central
1
Vacuum Cleaning Systems
ThisstandardisissuedunderthefixeddesignationF820;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscript
epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers procedures for determining air performance characteristics of household central vacuum cleaning
systems, which use a flexible cleaning hose assembly and incorporates a series universal motor(s).This test method does not apply
to the carpet cleaning mode of operation where dirt or debris is involved.
1.2 Thesetestsandcalculationsincludedeterminationofsuction,airflow,airpower,maximumairpower,andinputpowerunder
standard operating conditions (see Note 1).
2
NOTE 1—For more information on air performance characteristics, see Refs (1-6).
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for
information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. A specific precautionary statement is given in Note 4.
2. Referenced Documents
3
2.1 ASTM Standards:
E1 Specification for ASTM Liquid-in-Glass Thermometers
E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E2251 Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
F431 Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
4
2.2 AMCA Standard:
210–85 Laboratory Methods of Testing Fans for Rating
5
2.3 IEC Standard:
IEC 60312 Ed 3.2 Vacuum Cleaners for Household Use—Methods of Measuring the Performance
3. Terminology
3.1 Definitions:
3.1.1 air power, AP, W, n—in a vacuum cleaner, the net time rate of work performed by an air stream while expending energy
to produce an airflow by a vacuum cleaner under specified air resistance conditions.
3.1.2 automatic bleed valve, n—any device a part of a vacuum cleaner’s design, which automatically introduces an intentional
leak within the vacuum cleaner’s system when manufacturer specified conditions are met.
3.1.3 corrected airflow, Q, cfm, n—in a vacuum cleaner, the volume of air movement per unit of time under standard
atmospheric conditions.
3.1.4 input power, W, n—the rate at which electrical energy is absorbed by a vacuum cleaner.
3.1.5 model, n—the designation of a group of vacuum cleaners having the same mechanical and electrical construction with
only cosmetic or nonfunctional differences.
1
This test method is under the jurisdiction of ASTM Committee F11 on Vacuum Cleaners and is the direct responsibility of Subcommittee F11.22 on Air Performance.
Current edition approved AprilNov. 1, 2006.2011. Published April 2006.December 2011. Originally approved in 1988. Last previous edition approved in 20032006 as
F820 – 036. DOI: 10.1520/F0820-06.10.1520/F0820-11.
2
The boldface numbers in parentheses refer to the list of references at the end of this standard.
3
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
4
Available from Air Movement and Control Association, Inc., 30 West University Dr., Arlington Heights, IL 60004–1893.
5
Available from the IEC Web store, webstore.iec.ch, or American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
F820 – 11
3.1.6 population, n—the total of all units of a particular model vacuum cleaner being tested.
3.1.7 repeatabilitylimit(r),n—thevaluebelowwhichtheabsolutedifferencebetweentwoindividualtestresultsobtainedunder
repeatability conditions may be expected to occur with a probability of approximately 0.95 (95 %).
3.1.8 reproducibility limit (R), n
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.