Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

SCOPE
1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance.  
1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level.  
1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices.  
1.4 The values stated in SI units are to be regarded as the standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Oct-1999
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1143-99 - Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E1143–99
Standard Test Method for
Determining the Linearity of a Photovoltaic Device
Parameter with Respect To a Test Parameter
This standard is issued under the fixed designation E 1143; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 3.2.1 photovoltaic device parameter—a characteristic of a
photovoltaic device, such as short-circuit current or open-
1.1 This test method determines the degree of linearity of a
circuit voltage.
photovoltaic device parameter with respect to a test parameter,
3.2.2 test parameter—a characteristic of the test conditions
for example, short-circuit current with respect to irradiance.
to which the photovoltaic device is exposed, such as irradiance
1.2 The linearity determined by this test method applies
or temperature.
only at the time of testing, and implies no past or future
3.3 Symbols:
performance level.
Meaning Symbol
1.3 This test method applies only to non-concentrator ter-
Test parameter X
restrial photovoltaic devices.
Device parameter Y
1.4 Units—The values stated in SI units are to be regarded
Number of data pairs taken n
Slope of the linear function m
as the standard. No other units of measurement are included in
Fit to the data
this standard.
Estimated variance of the slope s
1.5 This standard does not purport to address all of the
4. Summary of Test Method
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
4.1 This test method requires the measurement of the
priate safety and health practices and determine the applica-
parameters in question at or near the anticipated device
bility of regulatory limitations prior to use.
operating conditions.The number of measurements made must
be sufficient to cover the range of operating conditions ex-
2. Referenced Documents
pected.
2.1 ASTM Standards:
4.2 Device electrical parameters shall be measured in ac-
E 772 Terminology Relating to Solar Energy Conversion
cordance with Test Methods E 948 or Methods E 1036, which-
E 948 Test Methods for Electrical Performance of Non-
ever is applicable.
Concentrator Terrestrial Photovoltaic Cells Using Refer-
4.3 A linear function that passes through the origin is fit to
ence Cells
the data, and the deviation of these data from the function is
E 1036 Test Methods for Testing Electrical Performance of
used as the criterion for determining linearity.
Nonconcentrator Terrestrial Photovoltaic Modules and Ar-
5. Significance and Use
rays Using Reference Cells
E 1328 Terminology Relating to Photovoltaic Solar Energy
5.1 This test method is used to evaluate the applicability of
Conversion
other ASTM test methods to a photovoltaic device.
5.2 The procedure described in this test method is intended
3. Terminology
to be used to determine the degree of linearity between the
3.1 Definitions—For definitions of terms used in this test
short-circuit current of a photovoltaic device and the irradiance
method, see Terminologies E 772 and E 1328.
level incident on the device. This test method can be used for
3.2 Definitions of Terms Specific to This Standard:
other device parameters, provided the functi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.