ASTM A750-77(1994)e1
(Specification)Standard Specification for Steel Air Ventilating Grille Units for Detention Areas (Withdrawn 2004)
Standard Specification for Steel Air Ventilating Grille Units for Detention Areas (Withdrawn 2004)
SCOPE
1.1 This specification applies to air ventilating grille units for detention areas, assembled in part from materials conforming to Specifications A627, A628, and A629.
1.2 The assemblies described herein are intended to provide two types of security, designated Type A and Type B.
1.2.1 Type A -A ventilation unit, utilizing homogeneous TR steel bars for the principal security component.
1.2.2 Type B -A ventilation unit utilizing perforated tool-resisting steel plate for the principal security component.
1.3 It is presumed that equipment manufacturers will fabricate and assemble the materials so as not to impair the performance characteristics specified in the applicable material specifications.
1.4 The descriptions herein of certain assemblies are not intended to infer that other assemblies cannot be used to obtain similar results.
WITHDRAWN RATIONALE
This specification applies to air ventilating grille units for detention areas, assembled in part from materials conforming to Specifications A 627, A 628, and A 629.
This specification is being withdrawn due to lack of interest and support for continued use.
Formerly under the jurisdiction of Committee F33 on Detention and Correctional Facilities, this specification was withdrawn in April 2004.
General Information
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
e1
Designation: A 750 – 77 (Reapproved 1994)
Standard Specification for
Steel Air Ventilating Grille Units for Detention Areas
This standard is issued under the fixed designation A 750; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
e NOTE—Section 8 was added editorially in June 1994.
1. Scope 3. Terminology
1.1 This specification applies to air ventilating grille units 3.1 Definitions:
for detention areas, assembled in part from materials conform- 3.1.1 grille unit—assembly of steel plate, round bars, flat
ing to Specifications A 627, A 628, and A 629. bars, wire mesh, and other steel shapes, suitably fastened by
1.2 The assemblies described herein are intended to provide welds, rivets, bolts, or other means in walls and ceilings for the
two types of security, designated Type A and Type B. purpose of permitting air to flow in or out of detention areas
1.2.1 Type A—A ventilation unit, utilizing homogeneous TR while preventing ingress or egress of persons confined therein.
steel bars for the principal security component. 3.2 Definitions of Terms Specific to This Standard:
1.2.2 Type B—A ventilation unit utilizing perforated tool- 3.2.1 Equipment Manufacturer—A manufacturer who fab-
resisting steel plate for the principal security component. ricates and assembles security products, including tool-
1.3 It is presumed that equipment manufacturers will fabri- resisting steel enclosures, for installation in areas requiring
cate and assemble the materials so as not to impair the security against ingress and egress. This manufacturer pro-
performance characteristics specified in the applicable material cesses the semifinished bar to produce a finished bar suitable
specifications. for fabrication into components and is responsible for all heat
1.4 The descriptions herein of certain assemblies are not treating and other fabricating processes to obtain the perfor-
intended to infer that other assemblies cannot be used to obtain mance characteristics specified. The manufacturer is also
similar results. responsible for fabricating and assembling all ancillary items
so as not to impair the performance characteristics of the
2. Referenced Documents
materials.
2.1 ASTM Standards:
3.2.2 Performance Characteristics—The response to tests
A 6/A 6M Specification for General Requirements for of specific materials as required in Specifications A 627, A 628,
Rolled Structural Steel Bars, Plates, Shapes, and Sheet
and A 629.
Piling
4. Ordering Information
A 29/A 29M Specification for Steel Bars, Carbon and Alloy,
Hot-Wrought and Cold-Finished, General Requirements 4.1 Orders for material under this specification shall include
for the following information:
A 627 Specification for Homogeneous Tool-Resisting Steel 4.1.1 Description of Bars:
Bars for Security Applications 4.1.1.1 Name of material (homogeneous steel, mild steel, or
A 628 Specification for Tool-Resisting Composite Steel other name),
Plates for Security Applications 4.1.1.2 Cross section (double ribbed round, hexagon, or
A 629 Specification for Tool-Resisting Steel Flat Bars and other shape),
Shapes for Security Applications 4.1.1.3 Dimensions (nominal diameter), and
4.1.1.4 ASTM designation A 627 and date of issue.
4.1.2 Description of Flat Bars and Shapes:
4.1.2.1 Dimensions (thickness, width, web thickness, other
This specification is under the jurisdiction of ASTM Committee F-33 on
descriptions of special shapes), and
Detention and Correctional Facilities and is the direct responsibility of Subcommit-
4.1.2.2 ASTM designation A 629 and date of issue.
tee F33.02 on Physical Barriers.
Current edition approved Aug. 26, 1977. Published October 1977.
4.1.3 Description of Tool-Resisting Composite Plate:
Annual Book of ASTM Standards, Vol 01.04.
4.1.3.1 Dimensions (width, length, and thickness),
Annual Book of ASTM Standards, Vol 01.05.
4.1.3.2 Size and spacing of holes in plate, and
Annual Book of ASTM Standards, Vol. 04.07.
Discontinued; see 1982 Annual Book of ASTM Standards, Vol 01.03. 4.1.3.3 ASTM designation A 628 and date of issue.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Copyright by ASTM Int'l (all rights reserved);
Reproduction authorized per License Agreement with ASTM International; Tue Jun 22 08:35:10 EDT 2004
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
e1
A 750 – 77 (1994)
4.1.4 Description of Wire Mesh: 5.1.1.1 Homogeneous bars shall be in accordance with
4.1.4.1 Material description (welded wire mesh, woven wire Specification A 627.
mesh), and
5.1.1.2 The spacing between the homogeneous bars shall be
4.1.4.2 Free air requirements.
4 6 ⁄16 in. (101.6 6 1.6 mm) on centers.
4.1.5 Description of Framing Members:
5.1.2 Steel Flat Bars:
4.1.5.1 Material description (thickness, width, length).
5.1.2.1 Non-tool-resisting steel bars, conforming to any of
4.1.6 Description of Fastening:
the specifications of Specifications A 6 and A 29, are accept-
4.1.6.1 Welding where required,
able. Other steel bars may also be used as agreed upon between
4.1.6.2 Bolting (methods of preventing removal of nuts),
the purchaser and the manufacturer.
4.1.6.3
...
Questions, Comments and Discussion