ASTM D2868-96(2001)
(Test Method)Standard Test Method for Nitrogen Content (Kjeldahl) and Hide Substance Content of Leather
Standard Test Method for Nitrogen Content (Kjeldahl) and Hide Substance Content of Leather
SCOPE
1.1 This test method covers the determination of the nitrogen content of all types of leather. The nitrogen content is used to calculate the hide substance (protein fiber) content of leather.
Note 1—This test method is essentially a composite of Method 6441 of Federal Test Method Standard No. 311 and Method B 5 of the American Leather Chemists Association.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D2868–96 (Reapproved 2001)
Standard Test Method for
Nitrogen Content (Kjeldahl) and Hide Substance Content of
1
Leather
This standard is issued under the fixed designation D 2868; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 3.3 The amount of ammonia in the boric acid is then
determined by back titration with standardized acid using a
1.1 This test method covers the determination of the nitro-
sharp color change indicator (green to purple) to determine the
gen content of all types of leather.The nitrogen content is used
end point.
tocalculatethehidesubstance(proteinfiber)contentofleather.
NOTE 1—ThistestmethodisessentiallyacompositeofMethod 6441of 4. Significance and Use
Federal Test Method Standard No. 311 and Method B 5 of the American
4.1 The nitrogen content as determined by this test method
Leather Chemists Association.
is normally considered to be related to the amount of hide
1.2 This standard does not purport to address all of the
substance (protein fiber) present in the leather sample.Afactor
safety concerns, if any, associated with its use. It is the
of 5.62 is normally used to calculate the hide substance from
responsibility of the user of this standard to establish appro-
the nitrogen content.
priate safety and health practices and determine the applica-
4.1.1 The 5.62 factor represents the average result of many
bility of regulatory limitations prior to use.
analyses of animal hides, but it cannot be considered to be
accuratesinceitvariessomewhatfromhidetohideofthesame
2. Referenced Documents
type, from type of hide to type of hide, and also with the
2.1 ASTM Standards:
thickness of hide retained in the final leather (split thickness as
D 2813 Practice for Sampling Leather for Physical and
compared to original hide thickness). As a result of these
2
Chemical Tests
variations, the true factor for any given leather may be
5
E 180 Practice for Determining the Precision of ASTM
expected to vary from 5.44 to 5.80 or about 63%.
3
Methods forAnalysis and Testing of Industrial Chemicals
4.2 A given leather sample may contain nitrogenous sub-
stances other than hide substance (protein fiber) which will be
3. Summary of Test Method
analyzed for by this test method, such as resins, dyestuffs, etc.,
3.1 The ground leather specimen prepared according to an
that contain nitrogen. Therefore, although this test method is
4
accepted procedure is digested with acid in the presence of a
fairly accurate for determining the nitrogen content of leather,
catalyst to convert the nitrogen to ammonium ion. The ammo-
its use for determining hide substance may result in large
nium ion formed is nonvolatile under these highly acid
errors.
conditions.
4.3 The hide substance value derived from this determina-
3.2 Theacidmixtureisthenmadealkalineandtheammonia
tion has a large bearing on other chemical determinations of a
liberated is distilled into a boric acid solution which absorbs
given leather. Any errors, such as those described in 4.1.1 and
the ammonia.
4.2,willbecarriedoverintotheseotheranalyticalcalculations.
5. Apparatus
1
This test method is under the jurisdiction ofASTM Committee D31 on Leather
5.1 Kjeldahl Apparatus consisting of:
and is the direct responsibility of Subcommittee D31.06 on Chemical Analysis—
5.1.1 Kjeldahl Flask, of 500 or 800-mL capacity for diges-
General. This test method was developed in cooperation with theAmerican Leather
Chemists Assn. (Standard Method B 5 – 1954).
tion of the sample.
Current edition approved May 10, 1996. Published July 1996. Originally
5.1.2 Heater, (gas or electric) for the Kjeldahl flask with
e1
published as D 2868 – 70 T. Last previous edition D 2868 – 73 (1991) .
2 fume hood or other exhaust system.
Annual Book of ASTM Standards, Vol 15.04.
3
Annual Book of ASTM Standards, Vol 15.05.
4
Acceptable procedures are published in Journal of the American Leather
5
Chemists Association, Vol 51, 1956 p. 497; or Offıcial Methods of Analysis, Am. Dahl, S., “Determination of Hide Substance in the Kjeldahl Method,” in
Leather Chemists Assn., available through the Office of the Secretary-Treasurer, Chemistry and Technology of Leather, Vol 4, Reinhold Publishing Co., New York,
Campus Station, Cincinnati, Ohio 45221; see Practice D 2813. NY, 1965.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D2868
5.1.3 Distillation Apparatus, consisting of an efficient vapor 7. Standardization
trap that can be sealed tightly in the top of the K
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.