Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)

SIGNIFICANCE AND USE
6.1 The wind resistance of sealed asphalt shingles is directly related to the ability of the sealed shingle to resist the force of the wind acting to lift the shingle from the shingle below. This test method employs the measured resistance of the shingle to mechanical uplift after sealing under defined conditions, in a calculation which determines whether this resistance exceeds the calculated force induced by wind passing over the surface of the shingle. Natural wind conditions differ with respect to intensity, duration, and turbulence; while these conditions were considered, and assumptions that specify higher than actual loads are used, extreme natural variations are beyond the means of this test method to simulate.  
6.2 Many factors influence the sealing characteristics of shingles in the field; for example, temperature, time, roof slope, contamination by dirt and debris, and fasteners that are misaligned or under driven and interfere with sealing. It is beyond the scope of this test method to address all of these influences. The classification determined in this test method is based on the mechanical uplift resistance determined when representative samples of shingles are sealed under defined conditions before testing.  
6.3 The calculations that support the Classes in 4.1 use several standard building environment factors. These include the 3-s wind gust exposure from ASCE 7-16, installation on Category I through IV buildings for all slopes, surface ground roughness B or C, and installation on buildings 60 ft tall or less.
Note 4: The assumptions used in the calculations for the classes in 4.1 cover the requirements for the majority of the asphalt shingle roofs installed. If environmental factors are outside those used in the calculations for these classes, such as surface ground roughness D, building heights greater than 60 ft tall, and other exposures as defined by ASCE 7-16, other calculations are required. Consult the shingle manufacturer for the speci...
SCOPE
1.1 This test method covers the procedure for calculating the wind resistance of asphalt shingles when applied in accordance with the manufacturer's instructions, and sealed under defined conditions. Shingle designs that depend on interlocking or product rigidity to resist the wind cannot be evaluated using this test method. The method calculates the uplift force exerted on the shingle by the action of wind at a specified velocity, and compares that to the mechanical uplift resistance of the shingle. A shingle is determined to be wind resistant at a specified basic wind speed when the measured uplift resistance exceeds the calculated uplift force for that velocity (3-second gust, ASCE 7).  
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
31-Dec-2018
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D7158/D7158M-19 - Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
English language
17 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D7158/D7158M-19 - Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
English language
17 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D7158/D7158M − 19
Standard Test Method for
Wind Resistance of Asphalt Shingles (Uplift Force/Uplift
1
Resistance Method)
This standard is issued under the fixed designation D7158/D7158M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This test method covers the procedure for calculating
D228/D228MTest Methods for Sampling, Testing, and
the wind resistance of asphalt shingles when applied in
Analysis of Asphalt Roll Roofing, Cap Sheets, and
accordance with the manufacturer’s instructions, and sealed
Shingles Used in Roofing and Waterproofing
under defined conditions. Shingle designs that depend on
D1079Terminology Relating to Roofing and Waterproofing
interlocking or product rigidity to resist the wind cannot be
D3161/D3161MTest Method for Wind-Resistance of Steep
evaluated using this test method. The method calculates the
Slope Roofing Products (Fan-Induced Method)
uplift force exerted on the shingle by the action of wind at a
D3462/D3462MSpecification for Asphalt Shingles Made
specified velocity, and compares that to the mechanical uplift
from Glass Felt and Surfaced with Mineral Granules
resistance of the shingle. A shingle is determined to be wind
D6381/D6381MTest Method for Measurement of Asphalt
resistant at a specified basic wind speed when the measured
Shingle Mechanical Uplift Resistance
uplift resistance exceeds the calculated uplift force for that
3
2.2 ASCE Standard:
velocity (3-second gust, ASCE 7).
ASCE7-16MinimumDesignLoadsandAssociatedCriteria
1.2 The values stated in either SI units or inch-pound units
for Buildings and Other Structures
are to be regarded separately as standard. The values stated in
ASCE 49-12Wind Tunnel Testing for Buildings and Other
each system may not be exact equivalents; therefore, each
Structures
system shall be used independently of the other. Combining
2.3 ANSI/UL Standard:
values from the two systems may result in non-conformance
ANSI/UL 2390–04Test Method for Wind ResistantAsphalt
with the standard.
4
Shingles with Sealed Tabs
1.3 This standard does not purport to address all of the
3. Terminology
safety concerns, if any, associated with its use. It is the
3.1 Definitions:
responsibility of the user of this standard to establish appro-
3.1.1 For definition of terms used in this test method, refer
priate safety, health, and environmental practices and deter-
to Terminology D1079.
mine the applicability of regulatory limitations prior to use.
3.2 Definitions of Terms Specific to This Standard:
1.4 This international standard was developed in accor-
3.2.1 sealant—as it relates to steep roofing shingles,is
dance with internationally recognized principles on standard-
defined as factory-applied or field-applied typically asphaltic
ization established in the Decision on Principles for the
material designed to seal the shingles to each other under the
Development of International Standards, Guides and Recom-
action of time and temperature after the shingles are applied to
mendations issued by the World Trade Organization Technical
a roof.
Barriers to Trade (TBT) Committee.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
1
ThistestmethodisunderthejurisdictionofASTMCommitteeD08onRoofing Standards volume information, refer to the standard’s Document Summary page on
andWaterproofingandisthedirectresponsibilityofSubcommitteeD08.02onSteep the ASTM website.
3
Roofing Products and Assemblies. Available fromAmerican Society of Civil Engineers (ASCE), 1801Alexander
Current edition approved Jan. 1, 2019. Published January 2019. Originally Bell Dr., Reston, VA 20191, http://www.asce.org.
4
approved in 2005. Last previous edition approved in 2017 as D7158/D7158M–17. Available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St.,
DOI: 10.1520/D7158_D7158M-19. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D7158/D7158M − 19
3.2.2 seal—as it relates to steep roofing shingles,isthe (factoryorfieldapplied)appliedinapatternalignedparallelto
bondingthatresultsfromtheactivationofthesealantunderthe the windward edge of the shingle.
action of time and temperature.
NOTE 3—It is not prohibited to use this test method for research
3.2.3 sealed—the condition of the shingles after they are
purposesusingvariationsinthenumberandplacementoffasteners.Ifth
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D7158/D7158M − 17 D7158/D7158M − 19
Standard Test Method for
Wind Resistance of Asphalt Shingles (Uplift Force/Uplift
1
Resistance Method)
This standard is issued under the fixed designation D7158/D7158M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the procedure for calculating the wind resistance of asphalt shingles when applied in accordance
with the manufacturer’s instructions, and sealed under defined conditions. Shingle designs that depend on interlocking or product
rigidity to resist the wind cannot be evaluated using this test method. The method calculates the uplift force exerted on the shingle
by the action of wind at a specified velocity, and compares that to the mechanical uplift resistance of the shingle. A shingle is
determined to be wind resistant at a specified basic wind speed when the measured uplift resistance exceeds the calculated uplift
force for that velocity (3-second gust, ASCE 7).
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D228/D228M Test Methods for Sampling, Testing, and Analysis of Asphalt Roll Roofing, Cap Sheets, and Shingles Used in
Roofing and Waterproofing
D1079 Terminology Relating to Roofing and Waterproofing
D3161/D3161M Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan-Induced Method)
D3462/D3462M Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules
D6381/D6381M Test Method for Measurement of Asphalt Shingle Mechanical Uplift Resistance
3
2.2 ASCE Standard:
ASCE 7-107-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures
ASCE 49-12 Wind Tunnel Testing for Buildings and Other Structures
2.3 ANSI/UL Standard:
4
ANSI/UL 2390–04 Test Method for Wind Resistant Asphalt Shingles with Sealed Tabs
3. Terminology
3.1 Definitions:
3.1.1 For definition of terms used in this test method, refer to Terminology D1079.
3.2 Definitions of Terms Specific to This Standard:
1
This test method is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.02 on Steep
Roofing Products and Assemblies.
Current edition approved Jan. 1, 2017Jan. 1, 2019. Published January 2017January 2019. Originally approved in 2005. Last previous edition approved in 20162017 as
D7158/D7158M – 16.D7158/D7158M – 17. DOI: 10.1520/D7158_D7158M-17.10.1520/D7158_D7158M-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from American Society of Civil Engineers (ASCE), 1801 Alexander Bell Dr., Reston, VA 20191, http://www.asce.org.
4
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D7158/D7158M − 19
3.2.1 sealant—as it relates to steep roofing shingles, is defined as factory-applied or field-applied typically asphaltic material
designed to seal the shingles to each other under the action of time and temperature after the shingles are applied to a roof.
3.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.