ASTM ISO/ASTM51956-13
(Main)Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing
Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing
SIGNIFICANCE AND USE
4.1 In radiation processing, TLDs are mainly used in the irradiation of blood products (see ISO/ASTM Practice 51939) and insects for sterile insect release programs (see ISO/ASTM Guide 51940). TLDs may also be used in other radiation processing applications such as the sterilization of medical products, food irradiation, modification of polymers, irradiation of electronic devices, and curing of inks, coatings and adhesives. (See ISO/ASTM Practices 51608, 51649, and 51702.)
4.2 For radiation processing, the absorbed-dose range of interest is from 1 Gy to 100 kGy. Some TLDs can be used in applications requiring much lower absorbed doses (for example, for personnel dosimetry), but such applications are outside the scope of this practice. Examples of TLDs and applicable dose ranges are given in Table 1. Information on various types of TLDs and their applications can be found in Refs (1-10).7
SCOPE
1.1 This practice covers procedures for the use of thermoluminescence dosimeters (TLDs) to measure the absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Thermoluminescence-dosimetry systems (TLD systems) are generally used as routine dosimetry systems.
1.2 The thermoluminescence dosimeter (TLD) is classified as a type II dosimeter on the basis of the complex effect of influence quantities on the dosimeter response. See ISO/ASTM Practice 52628.
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM 52628 “Practice for Dosimetry in Radiation Processing” for a TLD system. It is intended to be read in conjunction with ISO/ASTM 52628.
1.4 This practice covers the use of TLD systems under the following conditions:
1.4.1 The absorbed-dose range is from 1 Gy to 10 kGy.
1.4.2 The absorbed-dose rate is between 1 × 10-2 and 1 × 1010 Gy s-1.
1.4.3 The radiation-energy range for photons and electrons is from 0.1 to 50 MeV.
1.5 This practice does not cover measurements of absorbed dose in materials subjected to neutron irradiation.
1.6 This practice does not cover procedures for the use of TLDs for determining absorbed dose in radiation-hardness testing of electronic devices. Procedures for the use of TLDs for radiation-hardness testing are given in ASTM Practice E668.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ISO/ASTM 51956:2013(E)
Standard Practice for
Use of a Thermoluminescence-Dosimetry System (TLD
1
System) for Radiation Processing
This standard is issued under the fixed designation ISO/ASTM 51956; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision.
1. Scope priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
1.1 Thispracticecoversproceduresfortheuseofthermolu-
minescence dosimeters (TLDs) to measure the absorbed dose
2. Referenced documents
in materials irradiated by photons or electrons in terms of
2
2.1 ASTM Standards:
absorbed dose to water. Thermoluminescence-dosimetry sys-
E170Terminology Relating to Radiation Measurements and
tems (TLD systems) are generally used as routine dosimetry
Dosimetry
systems.
E666Practice for CalculatingAbsorbed Dose From Gamma
1.2 The thermoluminescence dosimeter (TLD) is classified
or X Radiation
as a type II dosimeter on the basis of the complex effect of
E668Practice for Application of Thermoluminescence-
influencequantitiesonthedosimeterresponse.SeeISO/ASTM
Dosimetry (TLD) Systems for Determining Absorbed
Practice 52628.
DoseinRadiation-HardnessTestingofElectronicDevices
2
1.3 This document is one of a set of standards that provides
2.2 ISO/ASTM Standards:
recommendations for properly implementing dosimetry in
51261Practice for Calibration of Routine Dosimetry Sys-
radiation processing, and describes a means of achieving
tems for Radiation Processing
compliancewiththerequirementsofISO/ASTM52628“Prac-
51608PracticeforDosimetryinanX-Ray(Bremsstrahlung)
ticeforDosimetryinRadiationProcessing”foraTLDsystem.
Facility for Radiation Processing
ItisintendedtobereadinconjunctionwithISO/ASTM52628.
51649Practice for Dosimetry in an Electron-Beam Facility
for Radiation Processing at Energies Between 300 keV
1.4 This practice covers the use of TLD systems under the
and 25 MeV
following conditions:
51702Practice for Dosimetry in Gamma Irradiation Facili-
1.4.1 The absorbed-dose range is from 1 Gy to 10 kGy.
-2
ties for Radiation Processing
1.4.2 The absorbed-dose rate is between1×10 and1×
10 -1
51707Guide for Estimating Uncertainties in Dosimetry for
10 Gy s .
Radiation Processing
1.4.3 The radiation-energy range for photons and electrons
51939Practice for Blood Irradiation Dosimetry
is from 0.1 to 50 MeV.
51940Guide for Dosimetry for Sterile Insect Release Pro-
1.5 This practice does not cover measurements of absorbed
grams
dose in materials subjected to neutron irradiation.
52628Practice for Dosimetry in Radiation Processing
1.6 This practice does not cover procedures for the use of
52701Guide for Performance Characterization of Dosim-
TLDs for determining absorbed dose in radiation-hardness
eters and Dosimetry Systems for Use in Radiation Pro-
testing of electronic devices. Procedures for the use of TLDs
cessing
for radiation-hardness testing are given in ASTM Practice
2.3 Joint Committee for Guides in Metrology (JCGM)
E668.
Reports:
1.7 This standard does not purport to address all of the
JCGM 100:2008, GUM 1995, with minor corrections,
safety concerns, if any, associated with its use. It is the
Evaluation of measurement data—Guide to the Expres-
3
responsibility of the user of this standard to establish appro-
sion of Uncertainty in Measurement
1 2
This practice is under the jurisdiction of ASTM Committee E61 on Radiation For referenced ASTM and ISO/ASTM standards, visit the ASTM website,
Processing and is the direct responsibility of Subcommittee E61.02 on Dosimetry www.astm.org, or contact ASTM Customer Service at service@astm.org. For
Systems, and is also under the jurisdiction of ISO/TC 85/WG 3. Annual Book of ASTM Standards volume information, refer to the standard’s
Current edition approved Aug. 1, 2013. Published November 2013. Originally Document Summary page on the ASTM website.
3
published as ASTM E 1956–98. The present International Standard ISO/ASTM DocumentproducedbyWorkingGroup1oftheJointCommitteeforGuidesin
51956:2013(E) is a major revision of the last previous edition ISO/ASTM Metrology (JCGM/WG 1). Available free of charge at the BIPM website (http://
51956:2005(E). www.bipm.org.
© ISO/ASTM International 2018 – All rights reserved
1
---------------------- Page: 1 ----------------------
ISO/ASTM 51956:2013(E)
JCGM 200:2008, VIM, International Vocabulary of 3.1.7 dosimetry system—system used for measuring ab-
Metrology—Basis and general concepts and associated sorbed dose, consisting of dosimeters, measurement instru-
4
terms mentsandtheirassociatedreferencestandards,andprocedures
for the system’s use.
...
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
ISO/ASTM 51956:2013(E)
Standard Practice for
Use of a Thermoluminescence-Dosimetry System (TLD
1
System) for Radiation Processing
This standard is issued under the fixed designation ISO/ASTM 51956; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision.
1. Scope priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
1.1 This practice covers procedures for the use of thermo-
luminescence dosimeters (TLDs) to measure the absorbed dose
2. Referenced documents
in materials irradiated by photons or electrons in terms of
2
2.1 ASTM Standards:
absorbed dose to water. Thermoluminescence-dosimetry sys-
E170 Terminology Relating to Radiation Measurements and
tems (TLD systems) are generally used as routine dosimetry
Dosimetry
systems.
E666 Practice for Calculating Absorbed Dose From Gamma
1.2 The thermoluminescence dosimeter (TLD) is classified
or X Radiation
as a type II dosimeter on the basis of the complex effect of
E668 Practice for Application of Thermoluminescence-
influence quantities on the dosimeter response. See ISO/ASTM
Dosimetry (TLD) Systems for Determining Absorbed
Practice 52628.
Dose in Radiation-Hardness Testing of Electronic Devices
2
1.3 This document is one of a set of standards that provides
2.2 ISO/ASTM Standards:
recommendations for properly implementing dosimetry in
51261 Practice for Calibration of Routine Dosimetry Sys-
radiation processing, and describes a means of achieving
tems for Radiation Processing
compliance with the requirements of ISO/ASTM 52628 “Prac-
51608 Practice for Dosimetry in an X-Ray (Bremsstrahlung)
tice for Dosimetry in Radiation Processing” for a TLD system.
Facility for Radiation Processing
It is intended to be read in conjunction with ISO/ASTM 52628.
51649 Practice for Dosimetry in an Electron-Beam Facility
for Radiation Processing at Energies Between 300 keV
1.4 This practice covers the use of TLD systems under the
and 25 MeV
following conditions:
51702 Practice for Dosimetry in Gamma Irradiation Facili-
1.4.1 The absorbed-dose range is from 1 Gy to 10 kGy.
-2
ties for Radiation Processing
1.4.2 The absorbed-dose rate is between 1 × 10 and 1 ×
10 -1
51707 Guide for Estimating Uncertainties in Dosimetry for
10 Gy s .
Radiation Processing
1.4.3 The radiation-energy range for photons and electrons
51939 Practice for Blood Irradiation Dosimetry
is from 0.1 to 50 MeV.
51940 Guide for Dosimetry for Sterile Insect Release Pro-
1.5 This practice does not cover measurements of absorbed
grams
dose in materials subjected to neutron irradiation.
52628 Practice for Dosimetry in Radiation Processing
1.6 This practice does not cover procedures for the use of
52701 Guide for Performance Characterization of Dosim-
TLDs for determining absorbed dose in radiation-hardness
eters and Dosimetry Systems for Use in Radiation Pro-
testing of electronic devices. Procedures for the use of TLDs
cessing
for radiation-hardness testing are given in ASTM Practice
2.3 Joint Committee for Guides in Metrology (JCGM)
E668.
Reports:
1.7 This standard does not purport to address all of the
JCGM 100:2008, GUM 1995, with minor corrections,
safety concerns, if any, associated with its use. It is the
Evaluation of measurement data—Guide to the Expres-
3
responsibility of the user of this standard to establish appro-
sion of Uncertainty in Measurement
1 2
This practice is under the jurisdiction of ASTM Committee E61 on Radiation For referenced ASTM and ISO/ASTM standards, visit the ASTM website,
Processing and is the direct responsibility of Subcommittee E61.02 on Dosimetry www.astm.org, or contact ASTM Customer Service at service@astm.org. For
Systems, and is also under the jurisdiction of ISO/TC 85/WG 3. Annual Book of ASTM Standards volume information, refer to the standard’s
Current edition approved Aug. 1, 2013. Published November 2013. Originally Document Summary page on the ASTM website.
3
published as ASTM E 1956–98. The present International Standard ISO/ASTM Document produced by Working Group 1 of the Joint Committee for Guides in
51956:2013(E) is a major revision of the last previous edition ISO/ASTM Metrology (JCGM/WG 1). Available free of charge at the BIPM website (http://
51956:2005(E). www.bipm.org.
© ISO/ASTM International 2024 – All rights reserved
1
---------------------- Page: 1 ----------------------
ISO/ASTM 51956:2013(E)
JCGM 200:2008, VIM, International Vocabulary of 3.1.7 dosimetry system—system used for measuring ab-
Metrology—Basis and general concepts and associated sorbed dose, consisting of dosimeters, measurement instru-
4
terms ments and their associated reference standards, and procedures
for the system’s use.
2.4 ISO Standard:
3.1.8 electron equilibrium—charged-particle e
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.