Standard Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods

SIGNIFICANCE AND USE
Personnel that are responsible for the creation, transfer, and storage of computed radiography NDE data will use this practice. This practice will define a set of information modules that along with the Practice E2339 and the DICOM standard will provide a standard means to organize CR inspection data. The CR inspection data may be displayed and analyzed on any device that conforms to the standard. Personnel wishing to view any CR inspection data stored in accordance with Practice E2339 may use this practice to help them decode and display the data contained in the DICONDE compliant inspection record.
SCOPE
1.1 This practice facilitates the interoperability of computed radiography (CR) imaging and data acquisition equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This practice is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information object definitions, information modules and a data dictionary that are specific to computed radiography test methods.
1.2 This practice has been developed to overcome the issues that arise when analyzing or archiving data from CR test equipment using proprietary data transfer and storage methods. As digital technologies evolve, data must remain decipherable through the use of open, industry-wide methods for data transfer and archival storage. This practice defines a method where all standard CR technique parameters and test results are communicated and stored in a standard manner regardless of changes in digital technology.
1.3 This practice does not specify:
1.3.1 A testing or validation procedure to assess an implementation's conformance to the standard.
1.3.2 The implementation details of any features of the standard on a device claiming conformance.
1.3.3 The overall set of features and functions to be expected from a system implemented by integrating a group of devices each claiming DICONDE conformance.
1.4 Although this practice contains no values that require units, it does describe methods to store and communicate data that do require units to be properly interpreted. The SI units required by this practice are to be regarded as standard. No other units of measurement are included in this practice.

General Information

Status
Historical
Publication Date
14-Feb-2010
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E2738-10 - Standard Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2738 – 10
Standard Practice for
Digital Imaging and Communication Nondestructive
Evaluation (DICONDE) for Computed Radiography (CR) Test
Methods
This standard is issued under the fixed designation E2738; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.3.2 The implementation details of any features of the
standard on a device claiming conformance.
1.1 This practice facilitates the interoperability of computed
1.3.3 The overall set of features and functions to be ex-
radiography (CR) imaging and data acquisition equipment by
pected from a system implemented by integrating a group of
specifying image data transfer and archival storage methods in
devices each claiming DICONDE conformance.
commonly accepted terms. This practice is intended to be used
1.4 Although this practice contains no values that require
in conjunction with Practice E2339 on Digital Imaging and
units, it does describe methods to store and communicate data
Communication in Nondestructive Evaluation (DICONDE).
that do require units to be properly interpreted. The SI units
Practice E2339 defines an industrial adaptation of the NEMA
required by this practice are to be regarded as standard. No
Standards Publication titled Digital Imaging and Communica-
other units of measurement are included in this practice.
tions in Medicine (DICOM, see http://medical.nema.org), an
international standard for image data acquisition, review,
2. Referenced Documents
storage and archival storage. The goal of Practice E2339,
2.1 ASTM Standards:
commonly referred to as DICONDE, is to provide a standard
E1316 Terminology for Nondestructive Examinations
that facilitates the display and analysis of NDE results on any
E1475 Guide for Data Fields for Computerized Transfer of
system conforming to the DICONDE standard. Toward that
Digital Radiological Examination Data
end, Practice E2339 provides a data dictionary and a set of
E2339 Practice for Digital Imaging and Communication in
information modules that are applicable to all NDE modalities.
Nondestructive Evaluation (DICONDE)
This practice supplements Practice E2339 by providing infor-
2.2 Other Documentation:
mation object definitions, information modules and a data
National Electrical ManufacturersAssociation Standard for
dictionary that are specific to computed radiography test
Digital Imaging and Communication in Medicine (DI-
methods.
COM), 2008.
1.2 This practice has been developed to overcome the issues
that arise when analyzing or archiving data from CR test
3. Terminology
equipment using proprietary data transfer and storage methods.
3.1 Definitions:
As digital technologies evolve, data must remain decipherable
3.1.1 Nondestructive evaluation terms used in this practice
through the use of open, industry-wide methods for data
can be found in Terminology E1316.
transfer and archival storage. This practice defines a method
3.1.2 DICONDE terms used in this practice are defined in
where all standard CR technique parameters and test results are
Practice E2339.
communicated and stored in a standard manner regardless of
changes in digital technology.
4. Summary of Practice
1.3 This practice does not specify:
4.1 A fundamental principle of DICONDE is the use of
1.3.1 A testing or validation procedure to assess an imple-
standard definitions and attribute formats for data communica-
mentation’s conformance to the standard.
tion and storage. This means all systems that are DICONDE
compliant use a common data dictionary and common com-
munication protocols. To further standardization, the elements
This practice is under the jurisdiction of ASTM Committee E07 on Nonde-
in the data dictionary are organized into common groups
structive Testing and is the direct responsibility of Subcommittee E07.11 on Digital
referred to as information modules. The data dictionary and
Imaging and Communication in Nondestructive Evaluation (DICONDE).
information modules common to all NDE modalities are
Current edition approved Feb. 15, 2010. Published March 2010. DOI: 10.1520/
E2738-10. defined in Practice E2339.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
E2738 – 10
TABLE 1 NDE CR Image Information Object Definition
DICOM Module DICONDE Module Reference Usage
Patient Component E2339, Section 7 M
Clinical Trial Subject Not Applicable
General Study Component Study E2339, Section 7 M
Patient Study Not Applicable
Clinical Trial Study Not Applicable
General Series Component Series E2339, Section 7 M
CR Series NDE
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.