Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)

SIGNIFICANCE AND USE
5.1 This practice establishes the basic parameters for the application and control of the CR examination method. This practice is written so it can be specified on the engineering drawing, specification, or contract.  
5.2 Weld Examination—Additional information on weld examination may be found in Practice E1032, ISO 17636-2, or both.  
5.3 Casting Examination—Additional information on casting examination may be found in Practice E1030.  
5.4 Electronic Components—Radiographic examination of electronic components shall comply with Practice E1161.  
5.5 Part-Specific Examination Technique—A detailed written procedure in the form of a part-specific examination technique (7.5) shall be documented for each part, or group of parts, and shall be approved by the Cognizant Radiographic Level 3.  
5.6 Personnel Qualification—Personnel performing examinations to this practice shall be qualified in accordance with ISO 9712, NAS 410, EN 4179, ANSI/ASNT CP 189, or SNT-TC-1A and certified by the employer or certifying agency as applicable. Other equivalent qualification documents may be used when specified on the contract or purchase order. The applicable revision shall be the latest unless otherwise specified in the contractual agreement between parties.  
5.7 System Qualification—All CR systems shall be qualified for their intended use. System qualification requirements are specified in subsection 7.1.  
5.8 Process Control—All CR systems shall be monitored for long term stability (process control) as specified in subsection 7.1.4.  
5.9 Preventative Maintenance—All CR systems and X-ray machines require periodic maintenance to ensure proper functionality. Preventative maintenance requirements are specified in subsection 6.2.  
5.10 Environmental Conditions—CR systems should be operated within environmental conditions that are in compliance with manufacturer’s stated acceptable environmental conditions, e.g., temperature and humidity. When CR systems are operated outsid...
SCOPE
1.1 This practice establishes the minimum requirements for computed radiographic (CR) examination for metallic and nonmetallic materials using X-ray or gamma radiation.  
1.2 Applicability—The requirements in this practice are intended to control the quality of computed radiographic examinations and are not intended to establish acceptance criteria for parts or materials.  
1.3 Basis of Application—The requirements of this practice, Practice E2445 and E2446 shall be used together. The requirements of Practice E2445 will provide the baseline performance evaluation and long term stability test procedures for the CR system. Practice E2446 CR performance levels are recommended in Table 1. The user of the CR system shall establish a written procedure that addresses the specific requirements and tests to be used in their application and shall be approved by the Cognizant Radiographic Level 3 before examination of production hardware. The items that shall be determined and addressed in the written procedure are:
(a) Personnel qualification and certification.
(b) Minimum effective pixel coverage appropriate to the acceptance criteria and to meet the radiographic image quality level requirements of Table 1.
(c) Additional tests per Practice E2445 deemed appropriate.
(d) Organizations using a gamma source or radiation energy above 320 kV may need to modify the E2445 tests, gauges, or both.
(e) Maximum allowed unsharpness when other than Table 1.
(f) The method used to provide image traceability to the part and the examination facility.  
1.3.1 This practice also requires the user to perform a system qualification suitable for its intended purpose and to issue a system qualification report (see subsection 7.1). Additionally, the user shall develop part specific inspection procedures (see subsections 5.5 and 7.5).  
1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as s...

General Information

Status
Published
Publication Date
31-Oct-2017
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E2033-17 - Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E2033-17 - Standard Practice for Radiographic Examination Using Computed Radiography (Photostimulable Luminescence Method)
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2033 − 17
Standard Practice for
Radiographic Examination Using Computed Radiography
1
(Photostimulable Luminescence Method)
This standard is issued under the fixed designation E2033; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Additionally, the user shall develop part specific inspection
procedures (see subsections 5.5 and 7.5).
1.1 This practice establishes the minimum requirements for
computed radiographic (CR) examination for metallic and 1.4 Units—The values stated in either SI units or inch-
nonmetallic materials using X-ray or gamma radiation. pound units are to be regarded separately as standard. The
values stated in each system may not be exact equivalents;
1.2 Applicability—The requirements in this practice are
therefore,eachsystemshallbeusedindependentlyoftheother.
intended to control the quality of computed radiographic
Combining values from the two systems may result in non-
examinations and are not intended to establish acceptance
conformance with the standard. Where applicable, SI units are
criteria for parts or materials.
shown in brackets [xx].
1.3 Basis of Application—Therequirementsofthispractice,
1.5 Compliance—Systems, equipment and materials that do
Practice E2445 and E2446 shall be used together.The require-
not comply with this practice shall require a waiver from the
mentsofPracticeE2445willprovidethebaselineperformance
Cognizant Engineering Organization (CEO).
evaluation and long term stability test procedures for the CR
1.6 This standard does not purport to address all of the
system. Practice E2446 CR performance levels are recom-
safety concerns, if any, associated with its use. It is the
mended in Table 1. The user of the CR system shall establish
responsibility of the user of this standard to establish appro-
a written procedure that addresses the specific requirements
priate safety, health, and environmental practices and deter-
and tests to be used in their application and shall be approved
mine the applicability of regulatory limitations prior to use.
by the Cognizant Radiographic Level 3 before examination of
1.7 This international standard was developed in accor-
production hardware. The items that shall be determined and
dance with internationally recognized principles on standard-
addressed in the written procedure are:
ization established in the Decision on Principles for the
(a)Personnel qualification and certification.
Development of International Standards, Guides and Recom-
(b)Minimum effective pixel coverage appropriate to the
mendations issued by the World Trade Organization Technical
acceptance criteria and to meet the radiographic image quality
Barriers to Trade (TBT) Committee.
level requirements of Table 1.
(c)Additional tests per Practice E2445 deemed appropri-
2. Referenced Documents
ate.
2
(d)Organizations using a gamma source or radiation en-
2.1 ASTM Standards:
ergy above 320 kV may need to modify the E2445 tests,
E746Practice for Determining Relative Image Quality Re-
gauges, or both.
sponse of Industrial Radiographic Imaging Systems
(e)Maximum allowed unsharpness when other than Table
E747Practice for Design, Manufacture and Material Group-
1.
ing Classification of Wire Image Quality Indicators (IQI)
(f)The method used to provide image traceability to the
Used for Radiology
part and the examination facility.
E1025Practice for Design, Manufacture, and Material
1.3.1 This practice also requires the user to perform a
Grouping Classification of Hole-Type Image Quality In-
system qualification suitable for its intended purpose and to
dicators (IQI) Used for Radiology
issue a system qualification report (see subsection 7.1).
E1030Practice for Radiographic Examination of Metallic
Castings
1
This test method is under the jurisdiction of ASTM Committee E07 on
Nondestructive Testing and is the direct responsibility of Subcommittee E07.01 on
2
Radiology (X and Gamma) Method. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved Nov. 1, 2017. Published December 2017. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1999. Last previous edition approved in 2013 as E2033-99(2013). Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/E2033-17. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. U
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: E2033 − 99 (Reapproved 2013) E2033 − 17
Standard Practice for
Computed RadiologyRadiographic Examination Using
Computed Radiography (Photostimulable Luminescence
1
Method)
This standard is issued under the fixed designation E2033; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice establishes the minimum requirements for computed radiographic (CR) examination for metallic and
nonmetallic materials using X-ray or gamma radiation.
1.2 Applicability—The requirements in this practice are intended to control the quality of computed radiographic examinations
and are not intended to establish acceptance criteria for parts or materials.
1.3 Basis of Application—This practiceThe requirements covers application details for computedof this practice, Practice E2445
radiology (CR)and E2446 examination using a process in which photostimulable luminescence isshall be used together. The
requirements of Practice E2445 emitted by the penetrating radiation detector, a storage phosphor imaging plate (SPIP). Because
the techniques involved and thewill provide the baseline performance evaluation and long term stability test procedures for the CR
system. Practice E2446 applications for CR examination are diverse, this practice is not intended to be limiting or restrictive, but
rather to address the general applications of the technology and thereby facilitate its use. Refer to GuidesCR performance levels
are recommended in Table 1. The user of the CR system shall establish a written procedure that addresses the specific requirements
and tests to be used in their application and shall E94 andbe approved E2007, Terminologyby the E1316, and PracticesCognizant
Radiographic Level E747 and3 before E1025, and 21 CFR 1020.40 and 29 CFR 1910.96 for additional information and
guidance.examination of production hardware. The items that shall be determined and addressed in the written procedure are:
(a) Personnel qualification and certification.
(b) Minimum effective pixel coverage appropriate to the acceptance criteria and to meet the radiographic image quality level
requirements of Table 1.
(c) Additional tests per Practice E2445 deemed appropriate.
(d) Organizations using a gamma source or radiation energy above 320 kV may need to modify the E2445 tests, gauges, or
both.
(e) Maximum allowed unsharpness when other than Table 1.
(f) The method used to provide image traceability to the part and the examination facility.
1.3.1 This practice also requires the user to perform a system qualification suitable for its intended purpose and to issue a system
qualification report (see subsection 7.1). Additionally, the user shall develop part specific inspection procedures (see subsections
5.5 and 7.5).
1.4 Units—The general principles discussed in this practice apply broadly to penetrating radiation CR systems. However, this
document is written specifically for use with X-ray and gamma-ray systems. Other CR systems, such as those employing neutrons,
will involve equipment and application details unique to such systems.values stated in either SI units or inch-pound units are to
be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall
be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
Where applicable, SI units are shown in brackets [xx].
1.5 Compliance—Systems, equipment and materials that do not comply with this practice shall require a waiver from the
Cognizant Engineering Organization (CEO).
1
This test method is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.01 on Radiology
(X and Gamma) Method.
Current edition approved June 1, 2013Nov. 1, 2017. Published June 2013December 2017. Originally approved in 1999. Last previous edition approved in 20062013 as
E2033 - 99 (2006).(2013). DOI: 10.1520/E2033-99R13.10.1520/E2033-17.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2033 − 17
TABLE 1 Total Image Unsharpness, Maximum
Material Thickness Maximum Allowed Image Unsharpness Recommended CR Performa
...