(Test Method)Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight
Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight
SCOPE
1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure.
1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions.
1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution.
1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest.
1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level.
1.5 There is no similar or equivalent ISO standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E948–95 (Reapproved 2001)
Standard Test Method for
Electrical Performance of Photovoltaic Cells Using
1
Reference Cells Under Simulated Sunlight
This standard is issued under the fixed designation E948; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
TABLE 1 Standard Reporting Conditions
1. Scope
1.1 This test method covers the determination of the elec- NOTE 1—The extraterrestrial solar constant and spectral irradiance
contained in Tables E490 do not represent the latest measurements of
trical performance of a photovoltaic cell under simulated
5
these quantities. The World Radiation Center recommends a value of
sunlight by means of a calibrated reference cell procedure.
−2
1367Wm for the solar constant along with more reliable measurements
1.2 Electrical performance measurements are reported with
of the extraterrestrial spectral irradiance.
respect to a select set of standard reporting conditions (SRC)
Reference Spectral Irradiance Total Irradiance Temperature
(see Table 1) or to user-specified conditions.
−2
Distribution (Wm ) (°C)
1.2.1 The SRC or user-specified conditions include the cell
Tables E 891 1000 25
temperature, the total irradiance, and the reference spectral
Tables E 892 1000 25
irradiance distribution. Tables E 490 1353 25
1.3 This test method is applicable only to photovoltaic cells
with a linear response over the range of interest.
1.4 The cell parameters determined by this test method
E927 Specification for Solar Simulation for Terrestrial
apply only at the time of test, and imply no past or future
4
Photovoltaic Testing
performance level.
E973 Test Method for Determination of the Spectral Mis-
1.5 There is no similar or equivalent ISO standard.
match Parameter Between a Photovoltaic Device and a
1.6 This standard does not purport to address all of the
4
Photovoltaic Reference Cell
safety concerns, if any, associated with its use. It is the
E1021 Test Methods for Measuring Spectral Response of
responsibility of the user of this standard to establish appro-
4
Photovoltaic Cells
priate safety and health practices and determine the applica-
E 1039 Test Method for Calibration of Silicon Non-
bility of regulatory limitations prior to use.
Concentrator Photovoltaic Primary Reference Cells Under
4
Global Irradiation
2. Referenced Documents
E1040 Specification for Physical Characteristics of Non-
2.1 ASTM Standards:
4
concentrator Terrestrial Photovoltaic Reference Cells
E490 Solar Constant and Zero Air Mass Solar Spectral
E1125 Test Method for Calibration of Primary Non-
2
Irradiance Tables
Concentrator Terrestrial Photovoltaic Reference Cells Us-
E491 Practice for Solar Simulation for Thermal Balance
4
ing a Tabular Spectrum
2
Testing of Spacecraft
E1328 Terminology Relating to Photovoltaic Solar Energy
E691 Practice for Conducting an Interlaboratory Study to
4
Conversion
3
Determine the Precision of a Test Method
E1362 Test Method for Calibration of Non-Concentrator
4
E772 Terminology Relating to Solar Energy Conversion
4
Photovoltaic Secondary Reference Cells
E891 Terrestrial Direct Normal Solar Spectral Irradiance
3
Tables for Air Mass 1.5
3. Terminology
E892 Tables for Terrestrial Solar Spectral Irradiance atAir
3.1 Definitions—Definitions of terms in this test method
3
Mass 1.5 for a 37° Tilted Surface
may be found in Terminology E772 and Terminology E1328.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 cell temperature, °C, n—the temperature of the semi-
1 conductor junction of a photovoltaic cell.
This test method is under the jurisdiction of ASTM Committee E44 on Solar,
3.2.2 junction temperature, n—synonym for cell tempera-
Geothermal,andOtherAlternativeEnergySourcesandisthedirectresponsibilityof
Subcommittee E44.09 on Photovoltaic Electric Power Conversion.
ture.
Current edition approved Oct. 10, 1995. Published March 1996.
3.2.3 light source, n—a source of radiant energy used for
2
Annual Book of ASTM Standards, Vol 15.03.
3
cellperformancemeasurementsthatsimulatesnaturalsunlight.
Annual Book of ASTM Standards, Vol 14.02.
4
Annual Book of ASTM Standards, Vol 12.02. 3.3 Symbols:Symbols:
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
E948
3.3.1 The following symbols and units are used in this test such as different manufacturers’ products. Repeated measure-
method: ments of the same cell may be used to study changes in device
2
A—cell area, m performance.
−1
a —temperature coefficient of reference cell,° C 5.3 This test method determine
...