ASTM C1216-92(1997)
(Test Method)Standard Test Method for Adhesion and Cohesion of One-Part Elastomeric Solvent Release Sealants
Standard Test Method for Adhesion and Cohesion of One-Part Elastomeric Solvent Release Sealants
SCOPE
1.1 This test method is a laboratory procedure that determines the adhesion and cohesion performance of one-part elastomeric, solvent release sealants at high and low temperatures by the extension and compression of test specimens.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Note 2.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
Designation: C 1216 – 92 (Reapproved 1997)
Standard Test Method for
Adhesion and Cohesion of One-Part Elastomeric Solvent
Release Sealants
This standard is issued under the fixed designation C 1216; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope both. This test method evaluates the performance of one-part
elastomeric solvent release sealants in joints subjected to
1.1 This test method is a laboratory procedure that deter-
movement and temperature aging.
mines the adhesion and cohesion performance of one-part
elastomeric, solvent release sealants at high and low tempera-
5. Apparatus
tures by the extension and compression of test specimens.
5.1 Extension-Compression Machine, as shown in Fig. 1,
1.2 The values stated in SI units are to be regarded as the
designed to extend the test specimens automatically at a
standard. The values given in parentheses are for information
constant rate of 3.20 mm ( ⁄8 in.)/h from a joint width of 11.2
only.
7 9
mm ( ⁄16 in.) to 14.29 mm ( ⁄16 in.) at −12 6 2.8°C ( +106
1.3 This standard does not purport to address all of the
5°F).
safety concerns, if any, associated with its use. It is the
5.2 Oven, forced-draft type, having the temperature con-
responsibility of the user of this standard to establish appro-
trolled to 70 6 1°C (158 6 2°F).
priate safety and health practices and determine the applica-
5.3 Oven, convection type, having the temperature con-
bility of regulatory limitations prior to use. For a specific
trolled to 50 6 1°C (122 6 2°F).
precautionary statement, see Note 2.
5.4 Freezer Chest or Cold Box, having the temperature
2. Referenced Documents controlled to −12 6 2.8°C (+10 6 5°F).
5.5 C-Clamps, or other clamping devices.
2.1 ASTM Standards:
C 33 Specification for Concrete Aggregates
6. Reagents
C 109 Test Method for Compressive Strength of Hydraulic
6.1 Purity of Reagents—Reagent grade chemicals shall be
Cement Mortars (Using 2-in. or 50-mm Cube Specimens)
3 used in all tests. Unless otherwise indicated, it is intended that
C 150 Specification for Portland Cement
all reagents shall conform to the specifications of the Commit-
C 717 Terminology of Building Seals and Sealants
tee on Analytical Reagents of the American Chemical Society,
2.2 Aluminum Association Standard:
where such specifications are available. Other grades may be
DAF-45 Designation System for Aluminum Finishes
used, provided it is first ascertained that the reagent is of
3. Terminology sufficiently high purity to permit its use without lessening the
accuracy of the determination.
3.1 Definitions—Refer to Definitions C 717 for definitions
6.2 Acetone or Methyl Ethyl Ketone Solvents.
of the following terms used in this test method: adhesive
6.3 Detergent Solution.
failure, bond breaker, cohesive failure, elastomeric, joint,
6.4 Distilled Water.
primer, sealant, solvent release sealant, and substrate.
6.5 Primer, if required.
4. Significance and Use
4.1 The failure of a building sealant in a joint that experi-
ences movement is manifested by cohesive failure in the
Series 520 Sealant Compound Tester, manufactured by Applied Test Systems,
Inc., 348 New Castle Rd., Butler, PA 16001, and a durability tester manufactured by
sealant or adhesive failure between the sealant and substrate, or
Ambard, Inc., 269-11 Sist Ave., New Hyde Park, NY 11040, have been found
suitable for this purpose.
1 7
This test method is under the jurisdiction of ASTM Committee C24 on Building “Reagent Chemicals, American Chemical Society Specifications,” Am. Chemi-
Seals and Sealants and is the direct responsibility of Subcommittee C24.20 on cal Soc., Washington, DC. For suggestions on the testing of reagents not listed by
General Sealant Standards. the American Chemical Society, see “Reagent Chemicals and Standards,” by Joseph
Current edition approved June 15, 1992. Published August 1992. Rosin, D. Van Nostrand Co., Inc., New York, NY, and the “United States
Annual Book of ASTM Standards, Vol 04.02. Pharmacopeia.”
3 8
Annual Book of ASTM Standards, Vol 04.01. Dawn, a registered trademark of Proctor and Gamble, Co., P.O. Box 599,
Annual Book of ASTM Standards, Vol 04.07. Cincinnati, OH 54201, or Palmolive Green, a registered trademark of Colgate
Available from Aluminum Association, 818 Connecticut Ave. NW, Washington, Palmolive Co., 300-T Park Ave., New York, NY 10022, have been found suitable for
DC 20006. this purpose.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
C 1216 – 92 (1997)
NOTE 1—Three-dimensional view of compression-extension machine with automatic control units shows four specimens ready for compression-
extension cycling.
FIG. 1 Compression Extension Machine
7. Sealants, Substrates, and Accessories 7.4 Release Paper, or other suitable material, if necessary,
to serve as a bond breaker to spacer bars for the preparation of
7.1 The sealants shall be obtained from previously un-
test specimens.
opened containers. Precondition the unopened containers of
sealant at 23 6 2°C (73.4 6 3.6°F) and 50 6 5 % relative
8. Preparation of Substrates
humidity for a minimum of 24 h.
8.1 Prior to use, the glass and aluminum (and, when
7.2 The standard substrates used in the test shall be Portland
cement mortar, float glass, and aluminum alloy. specified, other metallic substrates) shall be cleaned by wiping
the surface with methyl ethyl ketone or a similar solvent. Dip
NOTE 1—When requested, other substrates such as brick, marble, etc.
the surface in a 0.1 % detergent solution of a clear hand
may be specified by the purchaser in addition to the standard substrates.
dishwashing detergent in distilled or deionized water. Rinse the
7.2.1 Mortar blocks, six, prepared as described in 8.2. The
surface without touching it in distilled or deionized water and
blocks shall be 25.4-mm (1-in.) wide by 76.2-mm (3-in.) long
allow it to air dry.
by 25.4-mm (1-in.) thick.
NOTE 2—Methyl ethyl ketone and similar solvents are toxic and
7.2.2 Glass Plates, six, of clear float glass 25.4-mm (1-in.)
flammable and should be handled with caution in a well-ventilated area.
wide by 76.2-mm (3-in.) long by 6.35-mm ( ⁄4-in.) thick. The
float glass may require reinforcement to survive the rigors of 8.2 Mortar Slabs—Prepare cement mortar slabs, each 76 by
the subsequent test procedure. This must be completed prior to 25.4 by 25.4 mm (3 by 1 by 1 in.) in size, using one part of high
the compression-extension cycling described in Section 10. early strength Portland cement conforming to Type III of
Reinforcement is provided by adhering aluminum plates, Specification C 150 to two parts by weight of clean, uniformly
25.4-mm wide by 76.2-mm long by 6.35-mm thick, to the graded, concrete fine aggregate (sand) conforming to Specifi-
cation C 33. Use an amount of water sufficient to produce a
outside surfaces of the glass. Commercially available two-part
epoxies are suitable as adhesives. Although the time of flow of 100 6 5 when tested in accordance with the procedure
for the determination of consistency of cement mortar de-
reinforcement is not critical, it has been found convenient to
apply the aluminum plates to the glass before preparing the test scribed in Test Method C 109. After curing f
...
Questions, Comments and Discussion