ASTM C1330-02
(Specification)Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid Applied Sealants
Standard Specification for Cylindrical Sealant Backing for Use with Cold Liquid Applied Sealants
SCOPE
1.1 This specification covers the basic requirements for cylindrical sealant backing to be used with cold liquid applied sealants for use in building seals.
1.2 Cylindrical sealant backing serves one or more of the following functions:
1.2.1 Limits the amount and depth of sealant applied into a joint,
1.2.2 Acts as a bond breaker to allow joint movement without undue stress to the sealant,
1.2.3 Provides a form to assist the sealant in developing the proper shape factor, and
1.2.4 Acts as a barrier to the flow of sealant through the joint.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other ASTM committees or other organizations.
1.4 This specification may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 1330 – 02
Standard Specification for
Cylindrical Sealant Backing for Use with Cold Liquid-
1
Applied Sealants
This standard is issued under the fixed designation C 1330; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D 1623 Test Method for Tensile and Tensile Adhesion
3
Properties of Rigid Cellular Plastics
1.1 This specification covers the basic requirements for
D 5249 Specification for Backer Material for Use with
cylindrical sealant backing to be used with cold liquid applied
Cold- and Hot-Applied Joint Sealants in Portland-Cement
sealants for use in building seals.
4
Concrete and Asphalt Joints
1.2 Cylindrical sealant backing serves one or more of the
following functions:
3. Terminology
1.2.1 Limits the amount and depth of sealant applied into a
3.1 Definitions—The definitions for the following terms
joint,
used in this standard are found in Terminology C 717:
1.2.2 Acts as a bond breaker to allow joint movement
3.1.1 bi-cellular sealant backing, bond breaker, closed cell,
without undue stress to the sealant,
joint, open cell, outgassing, seal, sealant, sealant backing, skin.
1.2.3 Provides a form to assist the sealant in developing the
proper shape factor, and
4. Classification
1.2.4 Acts as a barrier to the flow of sealant through the
4.1 Cylindrical sealant backings are divided into three
joint.
types.
1.3 Thecommitteewithjurisdictionoverthisstandardisnot
4.1.1 Type C—cylindrical flexible sealant backings com-
aware of any comparable standards published by other ASTM
posed predominately of closed cell material as defined in
committees or other organizations.
Terminology C 717.
1.4 This specification may involve hazardous materials,
4.1.2 Type O—cylindrical flexible sealant backings com-
operations, and equipment. This standard does not purport to
posed of predominantly open cell material as defined in
address all of the safety concerns, if any, associated with its
Terminology C 717.
use. It is the responsibility of the user of this standard to
4.1.3 Type B—cylindrical flexible sealant backings com-
establish appropriate safety and health practices and deter-
posed of bi-cellular material as defined in Terminology C 717.
mine the applicability of regulatory limitations prior to use.
5. Significance and Use
2. Referenced Documents
5.1 This specification is designed to give some indication as
2.1 ASTM Standards:
2 tothedifferencesinperformanceforvariouscylindricalsealant
C 717 Terminology of Building Seals and Sealants
backings.
C 1016 Test Method for Determination ofWaterAbsorption
2 5.2 Althoughthisspecificationqualifiesacylindricalsealant
of Sealant Backing (Joint Filler) Material
backing for use, it does not address the compatibility of the
C 1087 Test Method for Determining Compatibility of
backing with the sealants with which it will make contact.
Liquid-Applied Sealants with Accessories Used in Struc-
Sealant compatibility should be confirmed by the sealant
2
tural Glazing Systems
manufacturer. Compatibility characteristics of sealants in con-
C 1253 Test Method for Determining the Outgassing Poten-
2 tact with cylindrical sealant backings can be determined by
tial of Sealant Backing
Test Method C 1087.
D 1622 Test Method forApparent Density of Rigid Cellular
3
Plastics
6. Test Methods
6.1 WaterAbsorption—Testingforwaterabsorptionshallbe
1
made in accordance with Test Method C 1016, Procedure B.
This specification is under the jurisdiction of ASTM Committee C24 on
Building Seals and Sealants and is the direct responsibility of Subcommittee C24.10
6.2 Density—Testing for density shall be made in accor-
on Specifications, Guides and Practices.
dance with Test Method D 1622.
Current edition approved May 10, 2002. Published June 2002. Originally
published as C 1330–96. Last previous edition C 1330–96.
2
Annual Book of ASTM Standards, Vol 04.07.
3 4
Annual Book of ASTM Standards, Vol 08.01. Annual Book of ASTM Standards, Vol 04.03.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1330–02
TABLE 1 Sealant Backer Properties
6.3 Outgassing—Testing for outgassing shall be made in
accordance with Test Method C 1253.
NOTE 1—This table applies to cylindrical sealant backing for use with
cold liquid applied sealants.
6.4 Compression Deflection and Recovery—Testing to be
made in accordance with Specification D 5249. Property Test Method Type C Type B Type O
6.5 Tensile Strength—Testingfortensilestrengthtobemade Water absorption (g/cc) C 1016 <0.03 0.03–0.10 >0.10
Procedure
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.