Standard Specification for Concrete Roof Tile

ABSTRACT
This specification deals with the standards for concrete tiles intended for use as roof covering where durability and appearance are required to provide a weather-resistant surface of specified design. The tiles are manufacture from cement, water, and mineral aggregates and shaped during manufacturing by molding, pressing, or extrustion. The tiles may or may not contain inclusion of other materials. The tiles shall also be tested for the following requirements: dimensional tolerance, freeze thaw, transverse strength, permeability, and water absorption.
SCOPE
1.1 This specification covers concrete tiles intended for the use as roof covering where durability and appearance are required to provide a weather-resistant surface of specified design.  
1.2 Tiles are manufactured from portland cement, water, and mineral aggregates with or without the inclusion of other materials.  
1.3 Tiles are shaped during manufacturing by molding, pressing, or extrusion. The shaping method can be used to describe the tile.  
1.4 Other constituents, such as chemical and mineral admixtures established as suitable for use in concrete, shall conform to ASTM standard specifications where applicable, or shall be shown by tests or experience not to be detrimental to the durability of concrete.  
1.5 Tiles are generally planar or undulating rectangular shapes available in a variety of cross-sectional areas profiles, shapes, sizes, surface textures, and colors.
Note 1: Concrete roof tiles covered by this specification are made from lightweight or normal weight aggregates, or both.
Note 2: When particular features are desired, such as color, surface texture for appearance, or other special features, such properties should be specified by the purchaser. However. the local sellers should be consulted as to the availability of concrete roof tile having a desired feature.  
1.6 The text of this specification references notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.  
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
28-Feb-2022
Drafting Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM C1492-22 - Standard Specification for Concrete Roof Tile
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM C1492-22 - Standard Specification for Concrete Roof Tile
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:C1492 −22
Standard Specification for
1
Concrete Roof Tile
This standard is issued under the fixed designation C1492; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom-
1.1 This specification covers concrete tiles intended for the
mendations issued by the World Trade Organization Technical
use as roof covering where durability and appearance are
Barriers to Trade (TBT) Committee.
required to provide a weather-resistant surface of specified
design.
2. Referenced Documents
1.2 Tiles are manufactured from portland cement, water,
2
2.1 ASTM Standards:
and mineral aggregates with or without the inclusion of other
C33/C33MSpecification for Concrete Aggregates
materials.
C67/C67MTest Methods for Sampling and Testing Brick
1.3 Tiles are shaped during manufacturing by molding,
and Structural Clay Tile
pressing, or extrusion. The shaping method can be used to
C90Specification for Loadbearing Concrete Masonry Units
describe the tile.
C140/C140MTest Methods for Sampling and Testing Con-
crete Masonry Units and Related Units
1.4 Otherconstituents,suchaschemicalandmineraladmix-
C150/C150MSpecification for Portland Cement
tures established as suitable for use in concrete, shall conform
C260/C260MSpecification for Air-Entraining Admixtures
toASTM standard specifications where applicable, or shall be
for Concrete
shown by tests or experience not to be detrimental to the
C331/C331MSpecification for Lightweight Aggregates for
durability of concrete.
Concrete Masonry Units
1.5 Tiles are generally planar or undulating rectangular
C494/C494MSpecification for Chemical Admixtures for
shapes available in a variety of cross-sectional areas profiles,
Concrete
shapes, sizes, surface textures, and colors.
C595/C595MSpecification for Blended Hydraulic Cements
NOTE 1—Concrete roof tiles covered by this specification are made
C618Specification for Coal Fly Ash and Raw or Calcined
from lightweight or normal weight aggregates, or both.
Natural Pozzolan for Use in Concrete
NOTE 2—When particular features are desired, such as color, surface
C979/C979MSpecification for Pigments for Integrally Col-
textureforappearance,orotherspecialfeatures,suchpropertiesshouldbe
ored Concrete
specified by the purchaser. However. the local sellers should be consulted
as to the availability of concrete roof tile having a desired feature. C989/C989MSpecification for Slag Cement for Use in
Concrete and Mortars
1.6 The text of this specification references notes and
C1157/C1157MPerformance Specification for Hydraulic
footnotes,whichprovideexplanatorymaterial.Thesenotesand
Cement
footnotes (excluding those in tables and figures) shall not be
considered as requirements of the standard.
3. Terminology
1.7 The values stated in inch-pound units are to be regarded
3.1 Definitions—Thefollowingtermsareusedinconnection
as standard. The values given in parentheses are mathematical
with concrete roof tiles:
conversions to SI units that are provided for information only
3.2 batten lugs, n—protrusions on the underside of the tile
and are not considered standard.
designed to engage over the upper edge of tiling battens.
1.8 This international standard was developed in accor-
3.3 head lap, n—distance of overlap measured from the
dance with internationally recognized principles on standard-
uppermost course to the point that it laps over the undermost
course.
1
This specification is under the jurisdiction of ASTM Committee C15 on
Manufactured Masonry Units and is the direct responsibility of Subcommittee
2
C15.06 on Roofing Tile. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved March 1, 2022. Published April 2022. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
published in 2001. Last previous edition approved in 2016 as C1492–03(2016). Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/C1492-22. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1492−22
3.4 high profile tile, n—tile with a rise to width ratio greater 5.1.5 Ground Granulated Blast Furnace Slag—
than 1:5. Specification C989/C989M.
5.1.6 Performance Specification C1157/C1157M.
3.5 int
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1492 − 03 (Reapproved 2016) C1492 − 22
Standard Specification for
1
Concrete Roof Tile
This standard is issued under the fixed designation C1492; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This specification covers concrete tiles intended for the use as roof covering where durability and appearance are required to
provide a weather-resistant surface of specified design.
1.2 Tiles are manufactured from portland cement, water, and mineral aggregates with or without the inclusion of other materials.
1.3 Tiles are shaped during manufacturing by molding, pressing, or extrusion. The shaping method can be used to describe the
tile.
1.4 Other constituents, such as chemical and mineral admixtures established as suitable for use in concrete, shall conform to
ASTM standard specifications where applicable, or shall be shown by tests or experience not to be detrimental to the durability
of concrete.
1.5 Tiles are generally planar or undulating rectangular shapes available in a variety of cross-sectional areas profiles, shapes, sizes,
surface textures, and colors.
NOTE 1—Concrete roof tiles covered by this specification are made from lightweight or normal weight aggregates, or both.
NOTE 2—When particular features are desired, such as color, surface texture for appearance, or other special features, such properties should be specified
by the purchaser. However. the local sellers should be consulted as to the availability of concrete roof tile having a desired feature.
1.6 The text of this specification references notes and footnotes, which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as requirements of the standard.
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1
This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.06 on Roofing
Tile.
Current edition approved Dec. 1, 2016March 1, 2022. Published December 2016April 2022. Originally published in 2001. Last previous edition approved in 20092016
as C1492–01(2009).C1492–03(2016). DOI: 10.1520/C1492-03R16.10.1520/C1492-22.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1492 − 22
2. Referenced Documents
2
2.1 ASTM Standards:
C33C33/C33M Specification for Concrete Aggregates
C67C67/C67M Test Methods for Sampling and Testing Brick and Structural Clay Tile
C90 Specification for Loadbearing Concrete Masonry Units
C140C140/C140M Test Methods for Sampling and Testing Concrete Masonry Units and Related Units
C150C150/C150M Specification for Portland Cement
C260C260/C260M Specification for Air-Entraining Admixtures for Concrete
C331C331/C331M Specification for Lightweight Aggregates for Concrete Masonry Units
C494/C494M Specification for Chemical Admixtures for Concrete
C595C595/C595M Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C979C979/C979M Specification for Pigments for Integrally Colored Concrete
C989C989/C989M Specification for Slag Cement for Use in Concrete and Mortars
C1157C1157/C1157M Performance Specification for Hydraulic Cement
3. Terminology
3.1 Definitions—The following terms are used in connection with concrete roof tiles:
3.2 batten lugs—lugs, n—protrusions on the underside of the tile designed to engage over the upper edge of tiling battens.
3.3 head lap—lap, n—distance of overlap measured from the uppermost course to the point that it laps over the undermost course.
3.4 high profile tile—tile, n—tile with a rise to width ratio greater than 1:5.
3.5 interlocking tile—tile, n—tiles with a system of ribs or
...

Questions, Comments and Discussion