SIGNIFICANCE AND USE
5.1 The maximum energy input rate test is used to confirm that the dishwasher is operating at the manufacturer's rated input prior to further testing. This test would also indicate any problems with the electric power supply, gas service pressure, or steam supply flow or pressure.  
5.2 The tank and booster temperature are verified and water consumption is adjusted to NSF specifications to ensure that the test is applied to a properly functioning dishwasher.  
5.3 Because much of a dishwasher's operating period is spent in the idle condition, tank heater and booster idle energy consumption rate is an important part of predicting an end user's energy consumption. The test is run with the door(s) open and with the door(s) closed, so that the energy use of both end-user behaviors can be characterized.  
5.4 A washing energy test generates an energy per rack usage. This is useful both as a measure for comparing the energy performance of one dishwasher to another and as a predictor of an end users energy consumption.  
5.5 Water-consumption characterization is useful for estimating water and sewage costs associated with dishwashing machine operation.
SCOPE
1.1 This test method covers the evaluation of the energy and water consumption of single-rack, door-type commercial dishwashers (hereafter referred to as dishwashers). Dishwashers may have a remote or self-contained booster heater. This test method does not address cleaning or sanitizing performance.  
1.2 This test method is applicable to both hot water sanitizing and chemical sanitizing stationary rack machines, which includes undercounter single rack machines, upright door-type machines, pot, pan and utensil machines, fresh water rinse machines and fill-and-dump machines. Dishwasher tank heaters are evaluated separately from the booster heater. Machines designed to be interchangeable in the field from high temp and low temp (that is, Dual Sanitizing Machines) and vice versa, shall be tested at both settings. Machines should be set for factory settings. If a dishwasher includes a booster heater as an option, energy should be sub metered separately for the booster heater. When the test method specifies to use the data plate or manufacturer’s recommendations, instructions, specifications, or requirements, the information source shall be used in the following order of preference and documented in the test report: data plate, user manual, communication with manufacturer.  
1.3 The following procedures are included in this test method:  
1.3.1 Procedures to Confirm Dishwasher is Operating Properly Prior to Performance Testing:  
1.3.1.1 Maximum energy input rate of the tank heaters (see 10.3).
1.3.1.2 Maximum energy input rate of the booster heater, if applicable (see 10.4).
1.3.1.3 Water consumption calibration (see 10.5).
1.3.1.4 Booster temperature calibration, if applicable (see 10.2).
1.3.1.5 Tank temperature calibration (see 10.7.6.1 and 10.7.6.2).  
1.3.2 Energy Usage and Cycle Rate Performance Tests:  
1.3.2.1 Washing energy test (see 10.7).
1.3.2.2 Idle energy rate (door(s) open and door(s) closed) (see 10.8).  
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information only.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
28-Feb-2018
Current Stage
Ref Project

Buy Standard

Standard
ASTM F1696-18 - Standard Test Method for Energy Performance of Stationary-Rack, Door-Type Commercial Dishwashing Machines
English language
19 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM F1696-18 - Standard Test Method for Energy Performance of Stationary-Rack, Door-Type Commercial Dishwashing Machines
English language
19 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F1696 − 18 An American National Standard
Standard Test Method for
Energy Performance of Stationary-Rack, Door-Type
1
Commercial Dishwashing Machines
This standard is issued under the fixed designation F1696; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.3.1.3 Water consumption calibration (see 10.5).
1.3.1.4 Booster temperature calibration, if applicable (see
1.1 Thistestmethodcoverstheevaluationoftheenergyand
10.2).
water consumption of single-rack, door-type commercial dish-
1.3.1.5 Tank temperature calibration (see 10.7.6.1 and
washers (hereafter referred to as dishwashers). Dishwashers
10.7.6.2).
may have a remote or self-contained booster heater. This test
1.3.2 Energy Usage and Cycle Rate Performance Tests:
method does not address cleaning or sanitizing performance.
1.3.2.1 Washing energy test (see 10.7).
1.2 This test method is applicable to both hot water sanitiz-
1.3.2.2 Idle energy rate (door(s) open and door(s) closed)
ing and chemical sanitizing stationary rack machines, which
(see 10.8).
includes undercounter single rack machines, upright door-type
1.4 The values stated in inch-pound units are to be regarded
machines, pot, pan and utensil machines, fresh water rinse
as standard. The SI units given in parentheses are for informa-
machines and fill-and-dump machines. Dishwasher tank heat-
tion only.
ers are evaluated separately from the booster heater. Machines
1.5 This standard does not purport to address all of the
designed to be interchangeable in the field from high temp and
safety concerns, if any, associated with its use. It is the
low temp (that is, Dual Sanitizing Machines) and vice versa,
responsibility of the user of this standard to establish appro-
shall be tested at both settings. Machines should be set for
priate safety, health, and environmental practices and deter-
factorysettings.Ifadishwasherincludesaboosterheaterasan
mine the applicability of regulatory limitations prior to use.
option,energyshouldbesubmeteredseparatelyforthebooster
1.6 This international standard was developed in accor-
heater. When the test method specifies to use the data plate or
dance with internationally recognized principles on standard-
manufacturer’s recommendations, instructions, specifications,
ization established in the Decision on Principles for the
or requirements, the information source shall be used in the
Development of International Standards, Guides and Recom-
following order of preference and documented in the test
mendations issued by the World Trade Organization Technical
report: data plate, user manual, communication with manufac-
Barriers to Trade (TBT) Committee.
turer.
1.3 The following procedures are included in this test 2. Referenced Documents
method: 2
2.1 ASTM Standards:
1.3.1 Procedures to Confirm Dishwasher is Operating
D3588Practice for Calculating Heat Value, Compressibility
Properly Prior to Performance Testing:
Factor, and Relative Density of Gaseous Fuels
1.3.1.1 Maximum energy input rate of the tank heaters (see
F857Specification for Hot Water and Chemical Sanitizing
10.3).
Commercial Dishwashing Machines, Stationary Rack
1.3.1.2 Maximum energy input rate of the booster heater, if
Type
applicable (see 10.4).
F861Specification for Commercial Dishwashing Racks
F953Specification for Commercial Dishwashing Machines
(Stationary Rack, Dump Type) Chemical Sanitizing
1
This test method is under the jurisdiction of ASTM Committee F26 on Food
Service Equipment and is the direct responsibility of Subcommittee F26.06 on
2
Productivity and Energy Protocol.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved March 1, 2018. Published March 2018. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 1996. Last previous edition approved in 2015 as F1696–15. DOI: Standards volume information, refer to the standard’s Document Summary page on
10.1520/F1696-18. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1696 − 18
3
2.2 NSF Standards: shut-down of certain machine components (pumps or belt
NSF/ANSI 3Commercial Warewashing Equipment motors) or reduction of certain temperature set points.
NSF/ANSI 170Glossary of Foodservice Terms
3.1.13 factory settings, n—a setting that has been pro-
4
2.3 ASHRAE Document:
grammed or adjusted at the factory and is representative of the
ASHRAE Guideline 2-1986 (RA90)Engineering Analysis
way that model is
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F1696 − 15 F1696 − 18 An American National Standard
Standard Test Method for
Energy Performance of Stationary-Rack, Door-Type
1
Commercial Dishwashing Machines
This standard is issued under the fixed designation F1696; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the evaluation of the energy and water consumption of single-rack, door-type commercial
dishwashers (hereafter referred to as dishwashers). Dishwashers may have a remote or self-contained booster heater. This test
method does not address cleaning or sanitizing performance.
1.2 This test method is applicable to both hot water sanitizing and chemical sanitizing stationary rack machines, which includes
undercounter single rack machines, upright door-type machines, pot, pan and utensil machines, fresh water rinse machines and
fill-and-dump machines. Dishwasher tank heaters are evaluated separately from the booster heater. Machines designed to be
interchangeable in the field from high temp and low temp (that is, Dual Sanitizing Machines) and vice versa, shall be tested at both
settings. Machines should be set for factory settings. If a dishwasher includes a booster heater as an option, energy should be sub
metered separately for the booster heater. When the test method specifies to use the data plate or manufacturer’s recommendations,
instructions, specifications, or requirements, the information source shall be used in the following order of preference and
documented in the test report: data plate, user manual, communication with manufacturer.
1.3 The following procedures are included in this test method:
1.3.1 Procedures to Confirm Dishwasher is Operating Properly Prior to Performance Testing:
1.3.1.1 Maximum energy input rate of the tank heaters (see 10.3).
1.3.1.2 Maximum energy input rate of the booster heater, if applicable (see 10.4).
1.3.1.3 Water consumption calibration (see 10.5).
1.3.1.4 Booster temperature calibration, if applicable (see 10.2).
1.3.1.5 Tank temperature calibration (see 10.7.6.1 and 10.7.6.2).
1.3.2 Energy Usage and Cycle Rate Performance Tests:
1.3.2.1 Washing energy test (see 10.7).
1.3.2.2 Idle energy rate (door(s) open and door(s) closed) (see 10.8).
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information
only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
D3588 Practice for Calculating Heat Value, Compressibility Factor, and Relative Density of Gaseous Fuels
F857 Specification for Hot Water and Chemical Sanitizing Commercial Dishwashing Machines, Stationary Rack Type
F861 Specification for Commercial Dishwashing Racks
1
This test method is under the jurisdiction of ASTM Committee F26 on Food Service Equipment and is the direct responsibility of Subcommittee F26.06 on Productivity
and Energy Protocol.
Current edition approved Aug. 1, 2015March 1, 2018. Published October 2015March 2018. Originally approved in 1996. Last previous edition approved in 20142015 as
F1696 – 14.F1696 – 15. DOI: 10.1520/F1696-15.10.1520/F1696-18.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F1696 − 18
F953 Specification for Commercial Dishwashing Machines (Stationary Rack, Dump Type) Chemical Sanitizing
3
2.2 NSF Standards:
NSF/ANSI 3 Commercial Warewashi
...

Questions, Comments and Discussion