Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems

SIGNIFICANCE AND USE
5.1 This practice can be used to determine an expected capacity for an existing or a proposed photovoltaic system in a particular location during a specified period of time (see data collection period in Test Method E2848).  
5.2 The expected capacity calculated in accordance with this practice can be compared with the capacity measured according to Test Method E2848 when the RC are the same.  
5.3 The comparison of expected capacity and measured capacity can be used as a criterion for plant acceptance.  
5.4 The user of this practice must select the performance simulation period over which the reporting conditions and expected capacity will be derived. Seasonal variations will likely cause both of these to change with differing performance simulation periods.  
5.5 When this practice is used in conjunction with Test Method E2848, the performance simulation period and the data collection period must agree. If they do not agree, the comparison between expected and measured capacity will not be meaningful.  
5.6 Historical or measured5 plane-of-array irradiance, ambient air temperature, and wind speed data can be used to select reporting conditions and calculate expected capacity. If historical data are used, the data collection period should match the time period of the measured data in terms of season and length.  
5.7 The simulated power output that is used to calculate the expected capacity should be derived from a performance model designed to represent the photovoltaic system which will be reported per Test Method E2848.
SCOPE
1.1 This practice provides procedures for determining the expected capacity of a specific photovoltaic system in a specific geographical location that is in operation under natural sunlight during a specified period of time. The expected capacity is intended for comparison with the measured capacity determined by Test Method E2848.  
1.2 This practice is intended for use with Test Method E2848 as a procedure to select appropriate reporting conditions (RC), including solar irradiance in the plane of the modules, ambient temperature, and wind speed needed for the photovoltaic system capacity measurement.  
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-Jul-2023
Current Stage
Ref Project

Buy Standard

Standard
ASTM E2939-13(2023) - Standard Practice for Determining Reporting Conditions and Expected Capacity for Photovoltaic Non-Concentrator Systems
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: E2939 − 13 (Reapproved 2023) An American National Standard
Standard Practice for
Determining Reporting Conditions and Expected Capacity
1
for Photovoltaic Non-Concentrator Systems
This standard is issued under the fixed designation E2939; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
3
1. Scope 2.2 IEEE Standards:
IEEE 1547-2003 Standard for Interconnecting Distributed
1.1 This practice provides procedures for determining the
Resources with Electric Power Systems
expected capacity of a specific photovoltaic system in a
specific geographical location that is in operation under natural
3. Terminology
sunlight during a specified period of time. The expected
3.1 Definitions of terms used in this practice may be found
capacity is intended for comparison with the measured capacity
in Terminology E772, IEEE 1547-2003, and Test Method
determined by Test Method E2848.
E2848.
1.2 This practice is intended for use with Test Method
3.2 Definitions:
E2848 as a procedure to select appropriate reporting conditions
3.2.1 expected capacity, photovoltaic system, n—the pre-
(RC), including solar irradiance in the plane of the modules,
dicted power rating that is derived from meteorological data
ambient temperature, and wind speed needed for the photovol-
and a performance model that describes a specific PV system in
taic system capacity measurement.
a specific location and time period.
1.3 The values stated in SI units are to be regarded as
3.2.2 measured capacity, photovolaic system, n—the output
standard. No other units of measurement are included in this
power of a photovoltaic system measured according to Test
standard.
Method E2848.
1.4 This standard does not purport to address all of the
3.2.3 performance model, photovoltaic system, n—a com-
safety concerns, if any, associated with its use. It is the
puter model which, at a minimum, simulates the operation of a
responsibility of the user of this standard to establish appro-
particular photovoltaic system using plane-of-array irradiance,
priate safety, health, and environmental practices and deter-
ambient temperature, and wind speed data as inputs to calcu-
mine the applicability of regulatory limitations prior to use.
late the instantaneous, simulated power output.
1.5 This international standard was developed in accor-
3.2.4 performance simulation period, photovoltaic system,
dance with internationally recognized principles on standard-
n—the period of time over which a single expected capacity
ization established in the Decision on Principles for the
prediction is performed. Compare with data collection period
Development of International Standards, Guides and Recom-
in Test Method E2848.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
3.2.5 plane-of-array irradiance, POA, n—see solar
irradiance, hemispherical in Terminology E772.
2. Referenced Documents
3.2.6 simulated power output, photovoltaic system,
2
2.1 ASTM Standards:
n—photovoltaic system power output derived from meteoro-
E772 Terminology of Solar Energy Conversion
logical data and a performance model.
E2848 Test Method for Reporting Photovoltaic Non-
3.2.7 time resolution, meteorological data, n—the time
Concentrator System Performance
interval between individual meteorological data points that has
a maximum averaging interval of 1 h, used to calculate both the
1
This practice is under the jurisdiction of ASTM Committee E44 on Solar, reporting conditions and the expected capacity.
Geothermal and Other Alternative Energy Sources and is the direct responsibility of
Subcommittee E44.09 on Photovoltaic Electric Power Conversion.
4. Summary of Practice
Current edition approved Aug. 1, 2023. Published August 2023. Originally
4.1 Test Method E2848 provides a procedure to measure the
approved in 2013. Last previous edition approved in 2018 as E2939 – 13 (2018).
DOI: 10.1520/E2939-13R23.
capacity of a photovoltaic system. The procedure involves a
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE),
the ASTM website. 445 Hoes Ln., Piscataway, NJ 08854, http://www.ieee.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.