Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed, Base Metal Thermocouple Cable

SCOPE
1.1 This specification establishes requirements for compacted, mineral-insulated, metal-sheathed, base-metal thermocouple cable, with at least two thermoelements.  
1.2 This specification describes the required material, processing and testing requirements, and also the optional supplementary testing and quality assurance and verification choices.  
1.3 The material of construction includes standard base metal thermoelements, austenitic stainless steel or other corrosion resistant sheath material, and either magnesia (MgO) or alumina(Al2O3) insulation.  
1.4 The values stated in inch-pound units or SI units may be regarded separately as standard. The values stated in each system are not exact equivalents, and each system shall be used independently of the other.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Dec-2001
Technical Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM E585/E585M-01a - Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed, Base Metal Thermocouple Cable
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E 585/E 585M – 01a
Standard Specification for
Compacted Mineral-Insulated, Metal-Sheathed, Base Metal
1
Thermocouple Cable
This standard is issued under the fixed designation E 585/E 585M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
4
1. Scope Stainless Steel Tubing for General Service
A 632 Specification for Seamless and Welded Austenitic
1.1 This specification establishes requirements for com-
Stainless Steel Tubing (Small-Diameter) for General Ser-
pacted, mineral-insulated, metal-sheathed, base metal thermo-
4
2 3 vice
couple cable, with at least two thermoelements.
B 163 Specification for Seamless Nickel and Nickel Alloy
1.2 This specification describes the required material, pro-
5
Condenser and Heat-Exchanger Tubes
cessing and testing requirements, and also the optional supple-
B 167 Specification for Nickel-Chromium-Iron Alloy (UNS
mentary testing and quality assurance and verification choices.
N06600, N06601, N06603, N06690, N06025, and
1.3 The material of construction includes standard base
5
N06045) Seamless Pipe and Tube
metal thermoelements, austenitic stainless steel or other corro-
B 516 Specification for Welded Nickel-Chromium-Iron Al-
sion resistant sheath material, and either magnesia (MgO) or
loy (UNS N06600, UNS N06603, UNS N06025, and UNS
alumina (Al O ) insulation.
2 3
5
N06045) Tubes
1.4 The values stated in inch-pound units or SI (metric)
E 220 Test Method for Calibration of Thermocouples by
units may be regarded separately as standard. The values stated
6
Comparison Techniques
in each system are not the exact equivalents, and each system
E 230 Specification and Temperature-Electromotive Force
shall be used independently of the other.
6
(EMF) Tables for Standardized Thermocouples
1.5 This standard does not purport to address all of the
E 235 Specification for Thermocouples, Sheathed, Type K,
safety concerns, if any, associated with its use. It is the
6
for Nuclear or for Other High-Reliability Applications
responsibility of the user of this standard to establish appro-
E 344 Terminology Relating to Thermometry and Hydrom-
priate safety and health practices and determine the applica-
6
etry
bility of regulatory limitations prior to use.
E 608/E 608M Specification for Metal-Sheathed Base-
6
2. Referenced Documents Metal Thermocouples
E 780 Test Method for Measuring the Insulation Resistance
2.1 The following documents of the latest issue form a part
6
of Sheathed Thermocouple Material at Room Temperature
of this specification to the extent specified herein. In the event
E 839 Test Methods for Sheathed Thermocouples and
of a conflict between this specification and other specifications
6
Sheathed Thermocouple Material
referenced herein, this specification shall take precedence.
E 1652 Specification for Magnesium Oxide and Aluminum
2.2 ASTM Standards:
Oxide Powder and Crushable Insulators Used in the
A 213/A 213M Specification for Seamless Ferritic and
Manufacture of Metal-Sheathed Platinum Resistance Ther-
Austenitic Alloy-Steel Boiler, Superheater, and Heat-
4
mometers, Base Metal Thermocouples, and Noble Metal
Exchanger Tubes
6
Thermocouples
A 249/A 249M Specification for Welded Austenitic Steel
2.3 ANSI Standard:
Boiler, Superheater, Heat-Exchanger, and Condenser
7
4
B46.1 Surface Texture
Tubes
A 269 Specification for Seamless and Welded Austenitic
3. Terminology
3.1 Definitions—The definitions given in Terminology
E 344 shall apply to this specification.
1
This specification is under the jurisdiction of ASTM Committee E20 on
3.2 Definitions of Terms Specific to This Standard:
Temperature Measurement and is the direct responsibility of Subcommittee E20.04
on Thermocouples.
Current edition approved Dec. 10, 2001. Published February 2002. Originally
published as E 585/E 585M-96. Last previous edition E 585/E 585M-01.
2 5
The terms “metal sheathed thermocouple cable” or “cable” will be used to Annual Book of ASTM Standards, Vol 02.04.
6
describe the subject description. Annual Book of ASTM Standards, Vol 14.03.
3 7
“Wire” is also used to describe “thermoelements.” Available from American National Standards Institute, 11 W. 42nd St., 13th
4
Annual Book of ASTM Standards, Vol 01.01. Floor, New York, NY 10036.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E 585/E 585M
FIG. 2 Examples of Alternating Configurations
FIG. 1 Examples of Adjacent Configurations
5.1.5 The kind of ceramic insulation (see 7.2). Note that
other insulation composition and impurity levels may
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.