ASTM D5469-00(2005)
(Guide)Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems
Standard Guide for Application of New Spray Applied Polyurethane Foam and Coated Roofing Systems
SIGNIFICANCE AND USE
This guide outlines general procedures and precautions necessary for correct and safe application of spray applied polyurethane foam roofing systems.
This guide is not all-inclusive; this guide is intended only to supplement detailed instructions from manufacturers and safety requirements established by law.
Refer to Polyurethane Foam Contractors Alliance AY-104 and NRCA Spray Polyurethane Foam-Based Manual for industry guidelines.
SCOPE
1.1 This guide covers the application of new roofing systems consisting of spray applied polyurethane foam insulation, elastomeric protective coatings, and optional mineral granules. This guide does not apply to retrofit or remedial applications.
1.2 Design criteria associated with the installation of spray in place polyurethane foam are beyond the scope of this specification.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
Designation:D5469 −00 (Reapproved 2005)
Standard Guide for
Application of New Spray Applied Polyurethane Foam and
1
Coated Roofing Systems
This standard is issued under the fixed designation D5469; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope D4442 Test Methods for Direct Moisture Content Measure-
ment of Wood and Wood-Base Materials
1.1 This guide covers the application of new roofing sys-
2.2 Other Standard:
tems consisting of spray applied polyurethane foam insulation,
4
SSPC SP-6 Steel Structures Painting Council
elastomeric protective coatings, and optional mineral granules.
5
2.3 Spray Polyurethane Foam Alliance Documents:
This guide does not apply to retrofit or remedial applications.
AY-102 Guide for Selection of Protective Coatings Over
1.2 Design criteria associated with the installation of spray
Spray Polyurethane Foam Roofing Systems
in place polyurethane foam are beyond the scope of this
AY-104 SprayPolyurethaneFoamRoofingSystemsforNew
specification.
and Remedial Roofing
1.3 The values stated in SI units are to be regarded as the
AY-118 Moisture Vapor Transmission
standard. The values given in parentheses are for information
NRCA Roofing and Waterproofing Manual, Spray Polyure-
only.
thane Foam-Based Roofing Manual
NRCA/SPFAQuality Control Guidelines for theApplication
1.4 This standard does not purport to address all of the
of Spray Polyurethane Foam Roofing
safety concerns, if any, associated with its use. It is the
NRCA/SPFA Manual for Inspection and Maintenance of
responsibility of the user of this standard to establish appro-
Spray Polyurethane Foam-Based Roof Systems, A Guide
priate safety and health practices and determine the applica-
for Building Owners
bility of regulatory limitations prior to use.
2.4 Other Documents:
2. Referenced Documents
Underwriters Laboratories, Roofing Materials and Systems
2 6
2.1 ASTM Standards: Directory
C1029 Specification for Spray-Applied Rigid Cellular Poly- FactoryMutualResearchCorporation, LossPreventionData
7
urethane Thermal Insulation Sheets 1–28
D451 Test Method for Sieve Analysis of Granular Mineral Alliance for the Polyurethane IndustryAX119 Guide for the
Surfacing For Asphalt Roofing Products Safe Handling and Use of Polyurethane and Polyisocya-
5
D1079 Terminology Relating to Roofing and Waterproofing nurate Foam Systems
D1621 Test Method for Compressive Properties of Rigid
NOTE 1—Details: Numerous details are found in the referenced
Cellular Plastics
documents, in foam and coating manufacturers literature, and from other
D1622 Test Method for Apparent Density of Rigid Cellular
sources. These details are to be considered general in nature. They should
not be used without modification to allow for movement between the
Plastics
building, roofing, roof top equipment, and roof drainage systems.
D2856 Test Method for Open-Cell Content of Rigid Cellular
3
Plastics by the Air Pycnometer (Withdrawn 2006)
3. Terminology
3.1 Definitions—Definitions are in accordance with Termi-
1
This guide is under the jurisdiction of ASTM Committee D08 on Roofing and
nology D1079.
Waterproofing and is the direct responsibility of Subcommittee D08.06 on Spray
Polyurethane Foam Roof Systems.
Current edition approved May 1, 2005. Published May 2005. Originally
4
approved in 1993. Last previous edition approved in 2000 as D5469 – 00. DOI: Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor,
10.1520/D5469-00R05. Pittsburgh, PA 15222-4656.
2 5
For referenced ASTM standards, visit the ASTM website, www.astm.org, or Available from Spray Polyurethane Foam Alliance, 1300 Wilson Boulevard,
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Suite 800, Arlington, VA 22209.
6
Standards volume information, refer to the standard’s Document Summary page on Available from Underwriters Laboratories (UL), Corporate Progress, 333
the ASTM website. Pfingsten Rd., Northbrook, IL 60062.
3 7
The last approved version of this historical standard is referenced on AvailablefromFactoryMutualResearchCorporation,1151Boston-Providence
www.astm.org. Tpke., Norwood, MA 02062.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
D5469−00 (2005)
3.2 Definitions of Terms Specific to This Standard: undercuts (upper surface of foam overhangs a lower surface)
3.2.1 F
...
Questions, Comments and Discussion