EN 761:1994/AC:1995
(Corrigendum)Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of the creep factor under dry conditions
- BACK
- 19-Jan-1995
- 01-Aug-2023
- 23.040.20
- 93/38/EEC
- M/BC/CEN/88/15
- CEN/TC 155
Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of the creep factor under dry conditions
Kunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Bestimmung des Kriechfaktors im trockenen Zustand
Systèmes de canalisations plastiques - Tubes plastiques thermodurcissables renforcés de verre (PRV) - Détermination du coefficient de fluage en condition sèche
Cevni sistemi iz polimernih materialov - Cevi iz duromernih materialov, ojačenih s steklenimi vlakni (GRP) - Določanje koeficienta lezenja v suhem
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-februar-1997
&HYQLVLVWHPLL]SROLPHUQLKPDWHULDORY&HYLL]GXURPHUQLKPDWHULDORYRMDþHQLKV
VWHNOHQLPLYODNQL*53'RORþDQMHNRHILFLHQWDOH]HQMDYVXKHP
Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes -
Determination of the creep factor under dry conditions
Kunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen
Kunststoffen (GFK) - Bestimmung des Kriechfaktors im trockenen Zustand
Systemes de canalisations plastiques - Tubes plastiques thermodurcissables renforcés
de verre (PRV) - Détermination du coefficient de fluage en condition seche
Ta slovenski standard je istoveten z: EN 761:1994
ICS:
23.040.20 Cevi iz polimernih materialov Plastics pipes
83.120 2MDþDQLSROLPHUL Reinforced plastics
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Pag
...
This May Also Interest You
ISO 7510:2017 specifies a method for the determination of constituent materials of a test sample cut from a glass-reinforced plastics (GRP) component intended for use in a piping system. It includes determination of resin, glass, aggregate and filler contents.
It is also applicable to the determination of the type and arrangement of the reinforcements. If used to determine the amounts of constituent materials in layered constructions it may be necessary to separate the laminate layers by cutting or splitting and testing each separately.
- Standard12 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Feb-2024
- 23.040.20
- 23.040.45
- CEN/TC 155
This document specifies the requirements of fitness for purpose of assembled polyethylene (PE) piping systems intended for the conveyance of water intended for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
It specifies the requirements for electrofusion, socket fusion, butt fusion and mechanical joints.
It specifies the method of preparation of test piece joints, and the tests to be carried out on these joints for assessing the fitness for purpose of the system under normal and extreme conditions.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to the introduction of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems, are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
This document is intended to only be used by the product manufacturer to assess the performance of components in accordance with EN 12201 2, EN 12201 3, or EN 12201 4 when joined together under normal and extreme conditions in accordance with this document. It is not intended for on-site testing of pipe systems.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 4 this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature for design purposes.
NOTE 3 For applications operating at constant temperatures greater than 20 °C up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
- Standard15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- CEN/TC 155
This document specifies materials and the general aspects of polyethylene (PE) pressure piping systems (mains and service pipes) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment attention is drawn to Clause 6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [6].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-2, EN 12201 3, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 3 For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- CEN/TC 155
This document specifies the characteristics of pipes made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.3 of this document. Components manufactured for water for general purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
For use in contaminated soils special consideration is taken for pipes intended for the transport of water intended for human consumption or raw water prior to treatment.
NOTE 3 Pipes constructions including barrier layers are not covered by this document. ISO 21004 provides an alternative solution for use in contaminated soils [10].
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201-3, EN 12201-4 and EN 12201-5, this document is applicable to PE pipes, fitting and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 4 For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
This document is applicable to three types of pipes:
— PE pipes (outside diameter dn) including any identification stripes;
— PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) as specified in Annex B, where all PE layers have the same MRS rating;
— PE pipes (outside diameter dn) with a peelable and contiguous thermoplastics additional layer on the outside of the pipe (“coated pipe”) as specified in Annex C.
NOTE 5 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
NOTE 6 Assessment of the resistance to slow crack growth of the PE pipe compound used for the manufacture of products conforming to this document is required in accordance with EN 12201-1:2024, Table 2.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- CEN/TC 155
This document specifies the characteristics of fusion fittings made from polyethylene (PE) as well as of mechanical fittings for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to subclause 6.6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 3 For applications operating at constant temperature greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
These fittings can be of the following types:
— electrofusion socket fittings;
— electrofusion saddle fittings;
— spigot end fittings (for butt fusion using heated tools and electrofusion socket fusion);
— socket fusion fittings (see Annex A);
— mechanical fittings;
— fabricated fittings (see Annex B).
- Standard43 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- 23.040.45
- CEN/TC 155
This document specifies the characteristics of valves or valve bodies made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial applications.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.4. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It is applicable to isolating unidirectional and bi-directional valves with spigot ends or electrofusion sockets intended to be fused with PE pipes or fittings conforming to EN 12201-2 and EN 12201-3 respectively.
Valves made from materials other than PE, conforming to the relevant standards can be used in PE piping systems according to EN 12201, provided that they have PE connections for butt fusion or electrofusion ends, conforming to EN 12201-3, or material transition joints (e.g. flanged joints).
NOTE 3 For valves or valve bodies intended for drains and sewers, additional information is given in Clause 9.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 4 For applications operating at constant temperature greater than 20 °C and up to 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours and additives.
NOTE 5 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
This document covers valves for pipes with a nominal outside diameter dn ≤ 400 mm.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- 23.060.01
- CEN/TC 155
This document specifies the definitions and requirements for unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) road gullies intended for use in non-pressure underground drains and sewers for surface water having a maximum depth of 4 m from ground level to the lowest point of the internal surface of the road gully. Road gullies complying with this document are intended to be used in pedestrian or vehicular traffic areas outside the building structure.
NOTE 1 Products complying with this document can also be used in non-traffic areas.
NOTE 2 Road gullies can be subject to national regulation which limit the maximum installation depth and / or local provisions. The installer checks for compliance prior to installation.
Road gullies complying with this document are made from a prescribed set of components that are manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) and assembled together.
Road gullies complying with this document may be equipped with optional devices (e.g. removable sand or silt bucket, leaf separator etc.), however the performance of these optional devices is not covered within the scope of this document.
Road gully components can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, low-pressure moulding, blow moulding, thermoforming or fabricated.
NOTE 3 Products complying with this document can be installed in underground applications without additional static calculation.
NOTE 4 The complete road gully assembly can also include non-plastic items (near surface or surface components for example) which are not covered by this document.
NOTE 5 The complete road gully assembly can be supplied with covers, frame covers and gratings complying with the relevant part of EN 124 which are not covered by this document. However, reference is made to this document for geometrical characteristics where applicable.
NOTE 6 Road gullies can be site assembled from different components, but can also be manufactured as a single unit.
This document covers:
- road gullies with or without sand / silt trap;
- road gullies with or without water seal preventing odour release;
- road gullies where the traffic load will or will not be carried by the complete gully (resp. "Direct loaded gullies" or "Indirect loaded gullies").
- Standard49 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Oct-2023
- 23.040.20
- 93.030
- CEN/TC 155
This document specifies a method for determining the longitudinal reversion of thermoplastics pipes,
to be carried out in either a liquid or in air. In case of dispute, heated liquid is used as the reference.
This document is applicable to all thermoplastics pipes with smooth internal and external walls of
constant cross‑section. It is not applicable to non‑smooth structured‑wall thermoplastics pipes.
The parameters appropriate to the pipe material and recommendations for the maximum levels of
reversion as a function of the pipe material are given in Annex A.
This method is applicable for pipes of wall thickness ≤ 16 mm.
- Standard13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-Oct-2023
- 23.040.20
- CEN/TC 155
This document gives guidance for specifying requirements for the AoC of compounds/formulations, products, joints and assemblies in accordance with the applicable part of EN 1566 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE A basic test matrix provides an overview of the testing scheme in Annex A.
In conjunction with EN 1566 1 (see European foreword), this document is applicable to solid-wall piping systems made of chlorinated poly(vinyl chloride) (PVC C) intended to be used for or soil and waste discharge systems (low and high temperature):
- inside buildings (application area code "B");
- for both inside buildings and buried in ground within the building structure (application area code "BD").
- Technical specification26 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Oct-2023
- 23.040.01
- 23.040.20
- 91.140.80
- CEN/TC 155
This document specifies methods for determining the ring creep properties for glass-reinforced thermosetting plastics (GRP) pipes. Properties include the creep factor and the long-term creep stiffness. Testing is performed under either wet (total immersion in water) or dry conditions.
Dry creep testing is typically performed for the assessment and control of raw material consistency. Wet creep testing is typically undertaken to determine the long-term creep performance in simulated use conditions.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 01-Aug-2023
- 23.040.20
- CEN/TC 155
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.