EN 1394:1996/AC:1997
(Corrigendum)Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of the apparent initial circumferential tensile strength
Plastics piping systems - Glass-reinforced thermosetting plastics (GRP) pipes - Determination of the apparent initial circumferential tensile strength
Kunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Bestimmung der scheinbaren Anfangs-Zugfestigkeit in Umfangsrichtung
Systèmes de canalisations en plastiques - Tubes en plastiques thermodurcissables renforcés de verre (PRV) - Détermination de la résistance en traction circonférentielle initiale apparente
Cevni sistemi iz polimernih materialov - Cevi iz duromernih materialov, okrepljenih s steklenimi vlakni (GRP) - Določanje navidezne začetne natezne trdnosti v obodni smeri
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.VPHULKunststoff-Rohrleitungssysteme - Rohre aus glasfaserverstärkten duroplastischen Kunststoffen (GFK) - Bestimmung der scheinbaren Anfangs-Zugfestigkeit in UmfangsrichtungSystemes de canalisations en plastiques - Tubes en plastiques thermodurcissables renforcés de verre (PRV) - Détermination de la résistance en traction circonférentielle initiale apparentePlastics piping systems
...
This May Also Interest You
This document specifies procedures suitable for the analysis of data which, when converted into logarithms of the values, have either a normal or a skewed distribution. It is intended for use with test methods and referring standards for glass-reinforced thermosetting plastics (GRP) pipes or fittings for the analysis of properties as a function of time. However, it can also be used for the analysis of other data.
Two methods are specified, which are used depending on the nature of the data. Extrapolation using these techniques typically extends a trend from data gathered over a period of approximately 10 000 h to a prediction of the property at 50 years, which is the typical maximum extrapolation time.
This document only addresses the analysis of data. The test procedures for collecting the data, the number of samples required and the time period over which data are collected are covered by the referring standards and/or test methods. Clause 6 discusses how the data analysis methods are applied to product testing and design.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 25-Feb-2025
- 23.040.20
- 23.040.45
- CEN/TC 155
This document gives guidance and requirements for the assessment of conformity of materials (compounds/formulations), products, joints and assemblies in accordance with EN 17670 2 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1 A test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2 If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065 [1] and EN ISO/IEC 17020 [2] is considered to be competent.
In conjunction with EN 17670 2 this document is applicable to road gullies.
- Technical specification24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 17-Dec-2024
- 23.040.20
- 93.030
- CEN/TC 155
This document specifies design for recycling guidelines for thermoplastics pipes and fittings, used as construction products or used for water supply to irrigation systems.
NOTE 1 Components used in irrigation systems such as flexibles and drip lines are not part of this document.
NOTE 2 Pipes and fittings used for cable management are not part of this document.
NOTE 3 Packaging of pipes and fittings is not part of this document.
The guidelines in this document are developed to facilitate mechanical recycling.
NOTE 4 The guidelines could also be beneficial for chemical recycling.
Thermoplastics pipes and fittings are considered to be those, where the total volume of the thermoplastic compound/formulation exceeds 50 %.
This document can also be used for other thermoplastics products used in a piping system such as manholes, inspection chambers, infiltration boxes and valves.
- Technical specification9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 10-Dec-2024
- 13.030.50
- 23.040.20
- 23.040.45
- M/584
- CEN/TC 155
- Corrigendum4 pagesEnglish languagesale 10% offe-Library read for×1 day
- 03-Dec-2024
- 23.040.20
- 23.040.45
- CEN/TC 155
ISO 7510:2017 specifies a method for the determination of constituent materials of a test sample cut from a glass-reinforced plastics (GRP) component intended for use in a piping system. It includes determination of resin, glass, aggregate and filler contents.
It is also applicable to the determination of the type and arrangement of the reinforcements. If used to determine the amounts of constituent materials in layered constructions it may be necessary to separate the laminate layers by cutting or splitting and testing each separately.
- Standard12 pagesEnglish languagesale 10% offe-Library read for×1 day
- 06-Feb-2024
- 23.040.20
- 23.040.45
- CEN/TC 155
This document specifies the characteristics of fusion fittings made from polyethylene (PE) as well as of mechanical fittings for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to subclause 6.6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 3 For applications operating at constant temperature greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
These fittings can be of the following types:
— electrofusion socket fittings;
— electrofusion saddle fittings;
— spigot end fittings (for butt fusion using heated tools and electrofusion socket fusion);
— socket fusion fittings (see Annex A);
— mechanical fittings;
— fabricated fittings (see Annex B).
- Standard43 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- 23.040.45
- CEN/TC 155
This document specifies the characteristics of pipes made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.3 of this document. Components manufactured for water for general purposes, drains and sewers, and vacuum sewer systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [4].
The intended uses include sea outfalls, laid in water and pipes suspended below bridges.
For use in contaminated soils special consideration is taken for pipes intended for the transport of water intended for human consumption or raw water prior to treatment.
NOTE 3 Pipes constructions including barrier layers are not covered by this document. ISO 21004 provides an alternative solution for use in contaminated soils [10].
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201-3, EN 12201-4 and EN 12201-5, this document is applicable to PE pipes, fitting and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 4 For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
This document is applicable to three types of pipes:
— PE pipes (outside diameter dn) including any identification stripes;
— PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) as specified in Annex B, where all PE layers have the same MRS rating;
— PE pipes (outside diameter dn) with a peelable and contiguous thermoplastics additional layer on the outside of the pipe (“coated pipe”) as specified in Annex C.
NOTE 5 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
NOTE 6 Assessment of the resistance to slow crack growth of the PE pipe compound used for the manufacture of products conforming to this document is required in accordance with EN 12201-1:2024, Table 2.
- Standard31 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- CEN/TC 155
This document specifies the characteristics of valves or valve bodies made from polyethylene (PE) for buried and above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial applications.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment, attention is drawn to 6.4. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It is applicable to isolating unidirectional and bi-directional valves with spigot ends or electrofusion sockets intended to be fused with PE pipes or fittings conforming to EN 12201-2 and EN 12201-3 respectively.
Valves made from materials other than PE, conforming to the relevant standards can be used in PE piping systems according to EN 12201, provided that they have PE connections for butt fusion or electrofusion ends, conforming to EN 12201-3, or material transition joints (e.g. flanged joints).
NOTE 3 For valves or valve bodies intended for drains and sewers, additional information is given in Clause 9.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 4 For applications operating at constant temperature greater than 20 °C and up to 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours and additives.
NOTE 5 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
This document covers valves for pipes with a nominal outside diameter dn ≤ 400 mm.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- 23.060.01
- CEN/TC 155
This document specifies materials and the general aspects of polyethylene (PE) pressure piping systems (mains and service pipes) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
NOTE 1 For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment attention is drawn to Clause 6 of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [6].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
In conjunction with EN 12201-2, EN 12201 3, EN 12201 4 and EN 12201 5, this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature.
NOTE 3 For applications operating at constant temperatures greater than 20 °C and up to and including 50 °C, see Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.
- Standard29 pagesEnglish languagesale 10% offe-Library read for×1 day
- 30-Jan-2024
- 23.040.20
- CEN/TC 155
This document specifies the requirements of fitness for purpose of assembled polyethylene (PE) piping systems intended for the conveyance of water intended for human consumption, raw water prior to treatment, drains and sewers under pressure, vacuum sewer systems, and water for other purposes, with the exception of industrial application.
It specifies the requirements for electrofusion, socket fusion, butt fusion and mechanical joints.
It specifies the method of preparation of test piece joints, and the tests to be carried out on these joints for assessing the fitness for purpose of the system under normal and extreme conditions.
NOTE 1 For PE components intended for the conveyance of water for human consumption and raw water prior to treatment attention is drawn to the introduction of this document. Components manufactured for water for other purposes, drains and sewers, and vacuum systems, are possibly not suitable for water supply for human consumption.
NOTE 2 Industrial application is covered by EN ISO 15494 [2].
The intended use includes sea outfalls, laid in water and pipes suspended below bridges.
It also specifies the test parameters for the test methods referred to in this document.
This document is intended to only be used by the product manufacturer to assess the performance of components in accordance with EN 12201 2, EN 12201 3, or EN 12201 4 when joined together under normal and extreme conditions in accordance with this document. It is not intended for on-site testing of pipe systems.
In conjunction with EN 12201-1, EN 12201 2, EN 12201 3 and EN 12201 4 this document is applicable to PE pipes, fittings and valves, their joints and joints with components of PE and other materials intended to be used under the following conditions:
a) allowable operating pressure, PFA, up to 25 bar ;
b) an operating temperature of 20 °C as a reference temperature for design purposes.
NOTE 3 For applications operating at constant temperatures greater than 20 °C up to and including 50 °C, see EN 12201-1:2024, Annex A.
The EN 12201 series covers a range of allowable operating pressures and gives requirements concerning colours.
NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes.