Home and Building Electronic Systems (HBES) - Part 5-1: Media and media dependent layers - Power line for HBES Class 1

This European Standard defines the mandatory and optional requirements for the medium specific physical and data link layer of power line Class 1 in its two variations PL110 and PL132. Data link layer interface and general definitions, which are medium independent, are given in EN 50090 4-1.

Elektrische Systemtechnik für Heim und Gebäude (ESHG) - Teil 5-1: Medien und medienabhängige Schichten - Signalübertragung auf elektrischen Niederspannungsnetzen für ESHG Klasse 1

Systèmes électroniques pour les foyers domestiques et les bâtiments (HBES) - Partie 5-1: Medias et couches dépendantes des medias - Courants porteurs pour HBES Classe 1

Stanovanjski in stavbni elektronski sistemi (HBES) - 5-1. del: Mediji in nivoji, odvisni od medijev - Napajalni vod za HBES razreda 1

General Information

Status
Withdrawn
Publication Date
24-Feb-2005
Withdrawal Date
31-Aug-2007
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
24-Apr-2023
Completion Date
24-Apr-2023

Relations

Buy Standard

Standard
EN 50090-5-1:2005
English language
45 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2005
Stanovanjski in stavbni elektronski sistemi (HBES) - 5-1. del: Mediji in nivoji,
odvisni od medijev - Napajalni vod za HBES razreda 1
Home and Building Electronic Systems (HBES) - Part 5-1: Media and media dependent
layers - Power line for HBES Class 1
Elektrische Systemtechnik für Heim und Gebäude (ESHG) - Teil 5-1: Medien und
medienabhängige Schichten - Signalübertragung auf elektrischen
Niederspannungsnetzen für ESHG Klasse 1
Systèmes électroniques pour les foyers domestiques et les bâtiments (HBES) - Partie 5-
1: Medias et couches dépendantes des medias - Courants porteurs pour HBES Classe 1
Ta slovenski standard je istoveten z: EN 50090-5-1:2005
ICS:
97.120 Avtomatske krmilne naprave Automatic controls for
za dom household use
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 50090-5-1
NORME EUROPÉENNE
EUROPÄISCHE NORM February 2005

ICS 97.120
English version
Home and Building Electronic Systems (HBES)
Part 5-1: Media and media dependent layers -
Power line for HBES Class 1
Systèmes électroniques pour les foyers Elektrische Systemtechnik für Heim
domestiques et les bâtiments (HBES) und Gebäude (ESHG)
Partie 5-1: Medias et couches Teil 5-1: Medien und medienabhängige
dépendantes des medias - Schichten -
Courants porteurs pour HBES Classe 1 Signalübertragung auf elektrischen
Niederspannungsnetzen
für ESHG Klasse 1
This European Standard was approved by CENELEC on 2004-09-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.

This European Standard exists in one official version (English). A version in any other language made by
translation under the responsibility of a CENELEC member into its own language and notified to the Central
Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech
Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung

Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 50090-5-1:2005 E
Foreword
This European Standard was prepared by the Technical Committee CENELEC TC 205, Home and
Building Electronic Systems (HBES) with the help of CENELEC co-operation partner Konnex Association,
Neerveldstraat 105, B-1200 Brussels, (former EHBESA).
The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50090-5-1
on 2004-09-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2005-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2007-09-01
CENELEC takes no position concerning the evidence, validity and scope of patent rights.
Konnex Association as Cooperating Partner to CENELEC confirms that to the extent that the standard
contains patents and like rights, the Konnex Association's members are willing to negotiate licenses
thereof with applicants throughout the world on fair, reasonable and non-discriminatory terms and
conditions.
Attention is drawn to the possibility that some of the elements of this standard may be the subject of
patent rights other than those identified above. CENELEC shall not be held responsible for identifying any
or all such patent rights.
EN 50090-5-1 is part of the EN 50090 series of European Standards, which will comprise the following
parts:
Part 1: Standardization structure
Part 2: System overview
Part 3: Aspects of application
Part 4: Media independent layers
Part 5: Media and media dependent layers
Part 6: Interfaces
Part 7: System management
Part 8: Conformity assessment of products
Part 9: Installation requirements
_______
- 3 - EN 50090-5-1:2005
Contents
1 Scope.5
2 Normative references .5
3 Definitions and abbreviations.6
3.1 Definitions .6
3.2 Abbreviations .6
4 Requirements for HBES Class 1, power line PL110 .7
4.1 Physical layer PL110 .7
4.1.1 General .7
4.1.2 Transmission medium.8
4.1.3 Medium attachment unit (MAU).9
4.1.4 Installation topology .12
4.1.5 Installation requirements .12
4.1.6 Surge protection .13
4.1.7 Services at the data link layer / physical layer interface .13
4.1.8 Features of PL110 physical layer.14
4.2 Data link layer type PL110.18
4.2.1 Domain Address/Individual Address/Group Address .19
4.2.2 Frame formats .20
4.2.3 Medium access control .24
4.2.4 Data link layer services .28
4.2.5 Parameters of layer-2 .30
4.2.6 Data link layer protocol.30
4.2.7 The layer-2 of a repeater .31
5 Requirements for HBES Class 1, power line PL132 .32
5.1 General .32
5.2 Physical layer PL132 .32
5.2.1 Medium definition .32
5.2.2 Datagram service .33
5.3 Data link layer type power line 132 .36
5.3.1 Frame format.36
5.3.2 Medium access control .41
5.3.3 L_Data service and protocol .41
5.3.4 L_PollData service .44
5.3.5 L_Busmon service .44
5.3.6 L_Service_Information service.44
Bibliography.45
Figure 1 - Structure of the MAU (example) .8
Figure 2 - Signal encoding.10
Figure 3 - Idealized overlapping of 105,6 kHz and 115,2 kHz .11
Figure 4 - Example of a PL inductive coupling circuit .12
Figure 5 - Example of a typical PL topology.12
Figure 6 - Character .14
Figure 7 - Structure of a datagram .15
Figure 8 - Structure of an acknowledgement frame .15
Figure 9 - Generation matrix of PL110 .16

Figure 10 - Operations of Galois-Field GF2 .17
Figure 11 - Three phase system .18
Figure 12 - Domain Address .19
Figure 13 - Individual Address.19
Figure 14 - Group Address.19
Figure 15 - Format 1s, frame fields with standard fieldname abbreviations .20
Figure 16 - Format 1s, L_Data_standard request frame format.20
Figure 17 - Control field.21
Figure 18 - Check octet .22
Figure 19 - Frame fields with standard fieldname abbreviations .22
Figure 20 - Format 1e, L_Data_extended request frame format.22
Figure 21 - Extended control cield.23
Figure 22 - Format 2, short acknowledgement frame format.24
Figure 23 - Timing diagram of an L_Data-request frame .27
Figure 24 - Complete frame encapsulation (datagram) .34
Figure 25 - Overview of primitives.35
Figure 26 - Frame fields with standard fieldname abbreviations .36
Figure 27 - L_Data request standard frame format.37
Figure 28 - Control field.37
Figure 29 - NPCI Field.38
Figure 30 - Frame fields with standard fieldname abbreviations .39
Figure 31 - L_Data_extended request frame format .39
Figure 32 - Extended control field .39
Figure 34 - Complete acknowledgement frame encapsulation (ACK) .40

Table 1 - General requirements for physical layer PL110.7
Table 2 - Example of typical cable characteristics .9
Table 3 - Power supply of the MAU.9
Table 4 - Requirements for the impedance of the MAU.11
Table 5 - Table of syndromes related to errors .16
Table 6 - L_Data-request priorities.26
Table 7 - Parameters for Ph-Data service.35
Table 8 - Ph-Service class parameters .35
Table 9 - Ph-Result values .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.