IEC 60238 ®
Edition 8.0 2011-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 2
AMENDEMENT 2
Edison screw lampholders
Douilles à vis Edison pour lampes

IEC 60238:2004/A2:2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
 Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
 IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
 Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
 Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.
 Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm
Le Catalogue en-ligne de la CEI vous permet d’effectuer des recherches en utilisant différents critères (numéro de référence,
texte, comité d’études,…). Il donne aussi des informations sur les projets et les publications retirées ou remplacées.
 Just Published CEI: www.iec.ch/online_news/justpub
Restez informé sur les nouvelles publications de la CEI. Just Published détaille deux fois par mois les nouvelles
publications parues. Disponible en-ligne et aussi par email.
 Electropedia: www.electropedia.org
Le premier dictionnaire en ligne au monde de termes électroniques et électriques. Il contient plus de 20 000 termes et
définitions en anglais et en français, ainsi que les termes équivalents dans les langues additionnelles. Egalement appelé
Vocabulaire Electrotechnique International en ligne.
 Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm
Si vous désirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez le FAQ du
Service clients ou contactez-nous:
Email: csc@iec.ch
Tél.: +41 22 919 02 11
Fax: +41 22 919 03 00
IEC 60238 ®
Edition 8.0 2011-02
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
AMENDMENT 2
AMENDEMENT 2
Edison screw lampholders
Douilles à vis Edison pour lampes

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE PRICE CODE
G
CODE PRIX
ICS 29.140.10 ISBN 978-2-88912-387-2

– 2 – 60238 Amend.2 © IEC:2011
FOREWORD
This amendment has been prepared by subcommittee 34B: Lamp caps and holders, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34B/1577/FDIS 34B/1593/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
_____________
2 Definitions
Add the following two new definitions:
2.28
enclosed reinforced insulated lampholder
lampholder for building-in so designed that on its own it fulfils the requirements for double or
reinforced insulated parts in class II applications
2.29
partly reinforced insulated lampholder
lampholder for building-in so designed that some parts of the lampholder require additional
means to fulfil the requirements with regard to double or reinforced insulation
NOTE In some cases, the dimensions might be achieved only after mounting into the luminaire.

60238 Amend.2 © IEC:2011 – 3 –
6 Classification
Replace the existing Subclause 6.5 by the following:
6.5 According to protection against electric shock
− unenclosed lampholders;
− enclosed lampholders;
− independent lampholders;
− partly reinforced insulated lampholders;
− enclosed reinforced insulated lampholders.
NOTE Where a lampholder is used with a working voltage of 50 % or less of its maximum rating, it may be
regarded as equivalent to a reinforced insulated lampholder.
7 Marking
Replace, in Subclause 7.1, the fourth paragraph (“Lampholders complying with the…”),
Note 3 and the fifth paragraph, added by Amendment 1, by the following new text:
Enclosed reinforced insulated lampholders offer an adequate level of protection for use in
luminaires where they are accessible in normal use. This information shall be indicated in the
manufacturer’s catalogue or the like.
For partly reinforced insulated lampholders, sufficient creepage distances and clearances to
outer accessible surfaces will require additional protection to some parts of the lampholder by
the luminaire design or by use of additional attachment(s) or cover(s). This information shall
be indicated in the manufacturer’s catalogue or the like.
Add the following new Note 3 to Subclause 7.1 below the first indent “- type reference”:
NOTE 3 Available technical documentation of the manufacturer like printed catalogues or online catalogues
should allow a clear identification of a lampholder either by a unique catalogue number or by an identifying
reference on the holder, specifying the essential characteristic features and the basic design of the product
supplemented by a clear description. Variations of the basic design like for example different cable length, fixing
means, colours etc., which do not affect safety or performance of the lampholder, may be disregarded in the type
reference marked on the product. Variations included in the type testing procedure are listed in the corresponding
test reports.
Add the following new Note 4 to Subclause 7.1 below the second indent “- type reference”:
NOTE 4 Note 3 applies.
Add the following new Note 5 to Subclause 7.1 below the thirdindent “- type reference”:
NOTE 5 Note 3 applies.
Renumber the existing last note as Note 6.

– 4 – 60238 Amend.2 © IEC:2011
14 Moisture resistance, insulation resistance and electrical strength
14.4 Replace the tenth paragraph (“Immediately after the insulation…”) by the following new
paragraph:
Immediately after the insulation resistance test, an a.c. voltage of substantially sine wave
form, with a frequency of 50 Hz or 60 Hz and with an r. m. s. value of (2 U + 1 000) V (where
U is the rated voltage) is applied for 1 min between the points prescribed. For enclosed and
unenclosed reinforced insulated lampholders, the test voltage shall be determined from
Table 10.2 of IEC 60598-1. Additionally, for switched lampholders, this voltage shall be
applied between live parts of different polarity and other metal parts with the switch both
closed and open.
17 Creepage distances and clearances
Replace the existing Table 13a by the following new table:

Rated voltage
Distances
V
mm
50 150 250 4)
1 Between live parts of different polarity, and
2 Between live parts and external metal parts, if not
covered with insulating material:

(this includes screws of backplate lampholders)

Basic insulation
- Creepage distances
1)
0,6 0,8 1,5 3
insulation PTI ≥ 600
1)
PTI < 600
1,2 1,6 2,5 5
4) 0,2 0,8 1,5 3
- Clearances
Reinforced insulation
- Creepage distances
1)
- 1,6 3 6
insulation PTI ≥ 600
1)
PTI < 600
- 3,2 5 6
4) - 1,6 3 6
- Clearances
3 Clearances for backplate lampholders *
- between live parts of different polarity, and
- between live parts and the boundary of the
space for the supply wires in backplate

lampholders not specifically intended for
building in:
0,6 0,8 1,5 3
NOTE Values for creepage distances and clearances may be found for intermediate values of rated voltages by
linear interpolation between tabulated values. No values are specified for rated voltages below 25 V as the
voltage test of 14.4 is considered sufficient.
* These values take account of possible unevenness of the mounting surface.

60238 Amend.2 © IEC:2011 – 5 –
Annex B – Guidance for requirements in IEC 61058-1 applicable to switches in
lampholders (see 13.2)
7.1.4 According to number of operating cycles
Replace the existing first paragraph by the following:
Only 7.1.4.4 is applicable.
Figure 1a – Nipple thread for lampholders. Basic profile and design profile for the nut
and for the screw
Replace the existing Figure 1a by the following new Figure 1a:
Metric thread
h = 0,866 03 s
s
h/4 = 0,216 51 s
h/8 = 0,108 25 s
60°
h/8
t0 = 5/8h = 0,541 27 s
h/2
30°
t0
h
h/4
IEC  452/11
Basic profile*
* The basic profile is the profile to which the deviations defining the limits of the external and the internal threads
are applied.
Design profile for the nut
d1 d d2 D D1 D2
Design profile for the screw
IEC  453/11
Dimensions in millimetres
Screw Nut
Designation d d2 d1 D D2 D1
s Max. Min. Max. Min. Max. Min. Max. Min. Max. Min.
M8×1 1 8,000 7,800 7,350 7,238 6,917 8,000 7,462 7,350 7,117 6,917
1 10,000 9,800 9,350 9,238 8,917 10,000 9,462 9,350 9,117 8,917
M10×1
1 13,000 12,800 12,350 12,190 11,917 13,000 12,510 12,350 12,117 11,917
M13×1
1 16,000 15,800 15,350 15,190 14,917 16,000 15,510 15,350 15,117 14,917
M16×1
– 6 – 60238 Amend.2 © IEC:2011
Figure 2a – Gauges for metric ISO thread for nipples
Replace the existing title and Figure 2a by the following new title and figure:
Gauges for the screw
d1 d2 d
Basic profile (see figure 1a)
"Go" gauge
"Not Go" gauge
IEC  454/11
Dimensions in millimetres
d d2 d1
Designation s Tolerance Tolerance Tolerance Wear
M10×1 1 9,800 +0,004 9,350 –0,012 8,917 +0,004 0,012
–0,004 –0,020 –0,004
M13×1 1 12,800 +0,004 12,350 –0,012 11,917 +0,004 0,012
–0,004 –0,020 –0,004
M16×1 1 15,800 +0,004 15,350 –0,012 14,917 +0,004 0,012
–0,004 –0,020 –0,004
NOTE The tolerances in the column d2 are on purpose positioned both on the same side of the
dimension to safeguard a no-man’s-land.

60238 Amend.2 © IEC:2011 – 7 –
Gauges for the nut
D D2 D1
Basic profile (see figure 1a)
"Go" gauge
"Not Go" gauge
IEC  455/11
Dimensions in millimetres
D D2 D1
Designation s Tolerance Tolerance Tolerance Wear
M10×1 1 10,000 +0,004 9,350 +0,012 9,117 +0,004 0,012
–0,004 +0,020 –0,004
M13×1 1 13,000 +0,004 12,350 +0,012 12,117 +0,004 0,012
–0,004 +0,020 –0,004
M16×1 1 16,000 +0,004 15,350 +0,012 15,117 +0,004 0,012
–0,004 +0,020 –0,004
NOTE The tolerances in the column D2 are on purpose positioned both on the same side of the
dimension to safeguard a no-man’s-land.
Figure 2a – Gauges for metric thread for nipples

___________
– 8 – 60238 Amend. 2 © CEI:2011
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34B: Culots et douilles, du comité
d'études 34 de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34B/1577/FDIS 34B/1593/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de cet amendement et de la publication de base ne sera
pas modifié avant la date de stabilité indiquée sur le site web de la CEI sous
"http://webstore.iec.ch" dans les données relatives à la publication recherchée. A cette date,
la publication sera
• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
_____________
2 Définitions
Ajouter les deux nouvelles définitions suivantes:
2.28
douille protégée à isolation renfo
...