IEC 61076-2-118:2026
(Main)Connectors for electrical and electronic equipment - Product requirements - Part 2-118: Circular connectors - Detail specification for shielded and unshielded, free and fixed connectors with bayonet-locking size B12, B17, B23 and B40, for power, signal and data transmission
General Information
- Abstract
This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications. These connectors consist of fixed and free connectors either rewirable or non-rewirable.
- Status
- Published
- Publication Date
- 30-Aug-2026
- Technical Committee
- SC 48B - Electrical connectors
- Current Stage
- PPUB - Publication issued
- Start Date
- 31-Aug-2026
- Completion Date
- 22-May-2026
Buy Documents
IEC 61076-2-118:2026 - Connectors for electrical and electronic equipment - Product requirements - Part 2-118: Circular connectors - Detail specification for shielded and unshielded, free and fixed connectors with bayonet-locking size B12, B17, B23 and B40, for power, signal and data transmission
IEC 61076-2-118:2026 - Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-118: Connecteurs circulaires - Spécification particuliere relative aux fiches et embases écrantées ou non écrantées avec verrouillage a baionnette, des tailles B12, B17, B23 et B40, pour la transmission de signaux, de puissance et de données
Overview
IEC 61076-2-118:2026 is an International Electrotechnical Commission (IEC) standard specifying requirements for circular connectors with bayonet locking in sizes B12, B17, B23, and B40. These connectors are designed for robust power, signal, and data transmission in industrial environments. The standard covers both shielded and unshielded versions, as well as free and fixed connectors that may be rewirable or non-rewirable.
These circular connectors are engineered to ensure secure and reliable connections in demanding applications, such as factory automation, process control, and other electrical and electronic equipment setups. With performance classifications, dimensional specifications, and test schedules, IEC 61076-2-118 ensures interoperability, mechanical safety, and data integrity.
Key Topics
Connector Sizes and Types:
- Bayonet-locking sizes: B12, B17, B23, B40
- Free (inline) and fixed (panel-mount) connectors
- Shielded/unshielded designs for electromagnetic compatibility
- Rewirable and non-rewirable options
Intended Functions:
- Power transmission (current ratings per pole up to 64 A)
- Signal transmission (up to 20 A per pole)
- Data transmission modules (covering 1 MHz–600 MHz)
Applications and Configurations:
- Multipurpose connectors handling power, signal, and high-frequency data lines
- Application A: Data transmission with power over data
- Application B: Data transmission without power over data
Performance and Testing:
- Electrical requirements: voltage proof, current capacity, insulation, and resistance
- Transmission performance: insertion loss, return loss, crosstalk, impedance, and attenuation
- Mechanical characteristics: durability, locking/unlocking torque, vibration resistance
- Climatic categories assessed for environmental suitability
Codings and Safety:
- Mechanical and polarization codes prevent mis-mating
- Safety features for industrial environments
- IP ratings for ingress protection
Applications
Circular connectors compliant with IEC 61076-2-118:2026 are critical in various industrial applications, ensuring dependable connectivity for:
Automation and Robotics:
- Secure power, signal, and data links in production lines and robotic systems
Process Control:
- Reliable connectors for sensors, actuators, and control modules in harsh environments
Machine Tools and Equipment:
- Rugged, quick-locking connectors for machinery requiring frequent maintenance
Power Distribution:
- Safe, high-current connectors for equipment panels and field installations
Data Networks in Industrial Environments:
- Shielded connections to prevent interference, supporting high-speed communication
The bayonet-locking mechanism provides fast, secure mating and unmating, essential in scenarios requiring rapid device installation or replacement. The range of sizes and contact configurations accommodates diverse cable types, transmission requirements, and installation constraints.
Related Standards
Connectors for electrical and electronic equipment often require compatibility and compliance with other IEC and international standards. Key related standards include:
IEC 61076 Series:
- Other parts cover alternative connector shapes, sizes, and applications
IEC 60512 Series:
- Test methods for connectors, including measurements for electrical continuity, contact resistance, insulation, and climatic testing
IEC 60068-1:
- Environmental testing standards relevant for connector qualification
IEC 60352 Series:
- Specifications for solderless connections in electrical components
By following IEC 61076-2-118:2026, manufacturers and end-users benefit from globally recognized guidelines, ensuring safe, compatible, and high-performance connectors for demanding industrial environments. Adopting this standard streamlines product development, compliance, and market acceptance for electrical connectors.
Buy Documents
IEC 61076-2-118:2026 - Connectors for electrical and electronic equipment - Product requirements - Part 2-118: Circular connectors - Detail specification for shielded and unshielded, free and fixed connectors with bayonet-locking size B12, B17, B23 and B40, for power, signal and data transmission
IEC 61076-2-118:2026 - Connecteurs pour équipements électriques et électroniques - Exigences de produit - Partie 2-118: Connecteurs circulaires - Spécification particuliere relative aux fiches et embases écrantées ou non écrantées avec verrouillage a baionnette, des tailles B12, B17, B23 et B40, pour la transmission de signaux, de puissance et de données
Frequently Asked Questions
IEC 61076-2-118:2026 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Connectors for electrical and electronic equipment - Product requirements - Part 2-118: Circular connectors - Detail specification for shielded and unshielded, free and fixed connectors with bayonet-locking size B12, B17, B23 and B40, for power, signal and data transmission". This standard covers: This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications. These connectors consist of fixed and free connectors either rewirable or non-rewirable.
This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23 and B40, typically used for power, signal and data transmissions in industrial applications. These connectors consist of fixed and free connectors either rewirable or non-rewirable.
IEC 61076-2-118:2026 is classified under the following ICS (International Classification for Standards) categories: 31.220.10 - Plug-and-socket devices. Connectors. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61076-2-118:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
IEC 61076-2-118 ®
Edition 1.0 2026-08
INTERNATIONAL
STANDARD
Connectors for electrical and electronic equipment - Product requirements -
Part 2-118: Circular connectors - Detail specification for shielded and
unshielded, free and fixed connectors with bayonet-locking size B12, B17, B23
and B40, for power, signal and data transmission
ICS 31.220.10 ISBN 978-2-8327-1466-9
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or
by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either
IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright
or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local
IEC member National Committee for further information.
IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigendum or an amendment might have been published.
IEC publications search - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Discover our powerful search engine and read freely all the
The advanced search enables to find IEC publications by a publications previews, graphical symbols and the glossary.
variety of criteria (reference number, text, technical With a subscription you will always have access to up to date
committee, …). It also gives information on projects, content tailored to your needs.
replaced and withdrawn publications.
Electropedia - www.electropedia.org
The world's leading online dictionary on electrotechnology,
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published containing more than 22 500 terminological entries in English
details all new publications released. Available online and and French, with equivalent terms in 25 additional languages.
once a month by email. Also known as the International Electrotechnical Vocabulary
(IEV) online.
IEC Customer Service Centre - webstore.iec.ch/csc
If you wish to give us your feedback on this publication or
need further assistance, please contact the Customer
Service Centre: sales@iec.ch.
CONTENTS
FOREWORD . 6
INTRODUCTION . 8
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 11
4 Technical information . 12
4.1 Systems of levels . 12
4.1.1 Performance levels . 12
4.1.2 Compatibility levels . 12
4.2 Classification into climatic categories . 12
4.3 Current-carrying capacity . 12
4.4 Type designation . 13
4.5 Marking . 16
4.6 Safety aspects . 16
5 Dimensional information . 16
5.1 General . 16
5.2 Survey of styles and variants . 16
5.2.1 General . 16
5.2.2 Terminations. 16
5.2.3 Fixed connectors . 16
5.2.4 Free connectors. 21
5.3 Interface dimensions . 30
5.3.1 Interface dimensions – B12 . 30
5.3.2 Interface dimensions – B17 . 37
5.3.3 Interface dimensions – B23 . 55
5.3.4 Interface dimensions – B40 . 66
5.3.5 Interface dimensions – Trapezoidal data module . 75
5.3.6 Engagement (mating) direction . 78
5.4 Gauges . 82
6 Characteristics . 83
6.1 General . 83
6.2 Contact assignment and other definitions . 83
6.3 Classification into climatic categories . 83
6.4 Electrical characteristics . 84
6.4.1 General . 84
6.4.2 Voltage proof . 84
6.4.3 Rated impulse withstand voltage – pollution degree . 85
6.4.4 Current-carrying capacity – temperature rise . 85
6.4.5 Contact and shield resistance . 86
6.4.6 Insulation resistance . 86
6.5 Transmission performance . 86
6.5.1 General . 86
6.5.2 Insertion loss . 86
6.5.3 Return loss . 87
6.5.4 Near-end cross talk (NEXT) . 87
6.5.5 Far-end cross talk (FEXT). 87
6.5.6 Transverse conversion loss (TCL) . 88
6.5.7 Transverse conversion transfer loss (TCTL) . 88
6.5.8 Transfer impedance . 88
6.5.9 Coupling attenuation . 89
6.5.10 Power sum alien (exogenous) NEXT (PS NEXT) . 89
6.5.11 Power sum alien (exogenous) FEXT (PS AFEXT) . 89
6.5.12 Propagation delay . 90
6.6 Mechanical characteristics . 90
6.6.1 Mechanical operations . 90
6.6.2 Effectiveness of connector coupling device . 90
6.6.3 Insertion and withdrawal forces . 91
6.6.4 Polarization and coding . 91
6.7 Other characteristics . 92
6.7.1 Vibration (sinusoidal) . 92
6.7.2 Shock . 92
6.7.3 Degree of protection provided by enclosures (IP code) . 92
6.7.4 Locking and unlocking torque . 92
6.7.5 Environmental aspects – Marking of insulation material (plastics) . 92
7 Test schedule . 93
7.1 General . 93
7.1.1 Overview . 93
7.1.2 Climatic category . 93
7.1.3 Arrangement for contact resistance measurements . 93
7.1.4 Arrangement for dynamic stress tests (vibration) . 94
7.1.5 Wiring of specimens . 95
7.2 Test schedule . 96
7.2.1 Test group P – Preliminary . 96
7.2.2 Test group AP – Dynamic/climatic . 96
7.2.3 Test group BP – Mechanical endurance . 99
7.2.4 Test group CP – Electrical load . 100
7.2.5 Test group DP – Connection method tests . 101
7.2.6 Test group EP – Signal integrity requirements . 101
7.2.7 Test group FP – Current carrying capacity . 102
Bibliography . 103
Figure 1 – Fixed connector with wire ends, male power contacts, male data contacts,
bayonet locking notch, and square flange front mounting . 17
Figure 2 – Fixed connector with wire ends, male power contacts, male data contacts,
bayonet locking notch, single hole front mounting, and keyway orientation . 18
Figure 3 – Fixed connector with wire ends, male power contacts, male data contacts,
bayonet locking notch, single hole rear mounting, and keyway orientation . 19
Figure 4 – Fixed connector with wire ends, female power contacts, female data
contacts, bayonet locking notch, and square flange front mounting . 19
Figure 5 – Fixed connector with wire ends, female power contacts, female data
contacts, bayonet locking notch, single hole front mounting, and keyway orientation . 20
Figure 6 – Fixed connector with wire ends, female power contacts, female data
contacts, bayonet locking notch, single hole rear mounting, and keyway orientation . 21
Figure 7 – Rewirable connector, male, straight version, with bayonet locking nut . 22
Figure 8 – Rewirable connector, male, angled version, with bayonet locking nut . 23
Figure 9 – Non-rewirable connector, male, straight version, with bayonet locking nut . 24
Figure 10 – Non-rewirable connector, male, angled version, with bayonet locking nut . 24
Figure 11 – Rewirable connector, male, straight version, with bayonet locking notch . 25
Figure 12 – Non-rewirable connector, male, straight version, with bayonet locking notch . 26
Figure 13 – Rewirable connector, female, straight version, with bayonet locking nut . 26
Figure 14 – Rewirable connector, female, angled version, with bayonet locking nut . 27
Figure 15 – Non-rewirable connector, female, straight version, with bayonet locking nut . 27
Figure 16 – Non-rewirable connector, female, angled version, with bayonet locking nut . 28
Figure 17 – Rewirable connector, female, straight version, with bayonet locking notch . 29
Figure 18 – Non-rewirable connector, female, straight version, with bayonet locking notch . 29
Figure 19 – Dimensions of contact positioning of type B1201011 . 31
Figure 20 – Dimensions of contact positioning of type B1201012 . 32
Figure 21 – Dimension of B12 bayonet locking (2 bayonet grooves) . 35
Figure 22 – Dimensions of contact positioning of type B1702011 . 37
Figure 23 – Dimensions of contact positioning of type B1702012 . 38
Figure 24 – Dimensions of contact positioning of type B1703011 . 40
Figure 25 – Dimensions of contact positioning of type B1703012 . 41
Figure 26 – Dimensions of contact positioning of type B1704011 . 43
Figure 27 – Dimensions of contact positioning of type B1704012 . 44
Figure 28 – Dimensions of contact positioning of type B1705011 . 46
Figure 29 – Dimensions of contact positioning of type B1705012 . 47
Figure 30 – Dimension of contact positioning of type B1706211 . 49
Figure 31 – Dimensions of contact positioning of type B1706212 . 50
Figure 32 – Dimension of B17 bayonet locking (2 bayonet grooves) . 53
Figure 33 – Dimensions of contact positioning of type B2307011 . 56
Figure 34 – Dimensions of contact positioning of type B2307012 . 57
Figure 35 – Dimension of contact positioning of type B2308111 . 60
Figure 36 – Dimensions of contact positioning of type B2308112 . 61
Figure 37 – Dimension of B23 bayonet locking (2 bayonet grooves) . 64
Figure 38 – Dimensions of contact positioning of type B4009011 . 67
Figure 39 – Dimensions of contact positioning of type B4009012 . 68
Figure 40 – Dimension of B40 bayonet locking (3 bayonet grooves) . 71
Figure 41 – Dimensions of contact positioning and cross section of D1 data module . 75
Figure 42 – Area for electric contact of shielding of D1 shielded data module . 76
Figure 43 – Dimensions of contact positioning and cross section D2 data module . 77
Figure 44 – Area for electric contact of shielding of D2 shielded data module . 78
Figure 45 – Engagement (mating) information . 79
Figure 46 – Gauge dimension . 83
Figure 47 – Contact resistance arrangement . 94
Figure 48 – Dynamic stress test arrangement . 95
Table 1 – Ratings of connector power part . 12
Table 2 – Ratings of connector signal part . 13
Table 3 – Ratings of connector data part (data module) . 13
Table 4 – Type designation . 14
Table 5 – Combination possibilities of power, signal and data . 15
Table 6 – Styles of fixed connectors . 17
Table 7 – Dimensions of style DM . 17
Table 8 – Dimensions of style EM . 18
Table 9 – Dimensions of style FM . 19
Table 10 – Dimensions of style DF . 20
Table 11 – Dimensions of style EF . 20
Table 12 – Dimensions of style FF . 21
Table 13 – Styles of free connectors . 22
Table 14 – Dimensions of style GM . 23
Table 15 – Dimensions of style HM . 23
Table 16 – Dimensions of style IM . 24
Table 17 – Dimensions of style JM . 25
Table 18 – Dimensions of style KM . 25
Table 19 – Dimensions of style LM . 26
Table 20 – Dimensions of style GF . 26
Table 21 – Dimensions of style HF . 27
Table 22 – Dimensions of style IF . 28
Table 23 – Dimensions of style JF . 28
Table 24 – Dimensions of style KF . 29
Table 25 – Dimensions of style LF . 30
Table 26 – Dimensions of contact positioning of type B12010 . 33
Table 27 – Type of B12 combined with D1 and D2 as application A . 34
Table 28 – Type of B12 combined with D1 and D2 as application B . 34
Table 29 – Dimensions of B12 bayonet locking . 35
Table 30 – Mechanical codings B12 connectors . 36
Table 31 – Dimensions of B12 mechanical codings . 36
Table 32 – Dimensions of contact positioning of types B17020 . 39
Table 33 – Dimensions of contact positioning of types B17030 . 42
Table 34 – Dimensions of contact positioning of types B17040 . 45
Table 35 – Dimensions of contact positioning of types B17050 . 48
Table 36 – Dimensions of contact positioning of types B17062 . 51
Table 37 – Types of B17 combined with D1 and D2 as application A . 52
Table 38 – Types of B17 combined with D1 and D2 as application B . 52
Table 39 – Dimensions of B17 bayonet locking . 53
Table 40 – Mechanical codings B17 connectors . 54
Table 41 – Dimensions of B17 mechanical codings . 55
Table 42 – Dimensions of contact positioning of types B23070 . 58
Table 43 – Dimensions of contact positioning of types B23081 . 62
Table 44 – Types of B23 combined with D1 and D2 as application A . 63
Table 45 – Types of B23 combined with D1 as application B . 64
Table 46 – Dimensions of B23 bayonet locking . 65
Table 47 – Mechanical codings of B23 connectors . 65
Table 48 – Dimensions of B23 mechanical codings . 66
Table 49 – Dimensions of contact positioning of types B40090 . 69
Table 50 – Type of B40 combined with D1 and D2 as application A . 70
Table 51 – Type of B40 combined with D1 and D2 as application B . 70
Table 52 – Dimensions of B40 bayonet locking . 72
Table 53 – Mechanical codings of B40 connectors . 72
Table 54 – Dimensions of B40 mechanical codings . 74
Table 55 – Dimensions of contact positioning of the D1 data module . 76
Table 56 – Dimensions of contact positioning of the D2 data module . 78
Table 57 – Connectors dimensions in mated and locked position . 79
Table 58 – Gauges . 83
Table 59 – Climatic category . 84
Table 60 – Voltage proof . 84
Table 61 – Rated impulse voltage and pollution degree . 85
Table 62 – Insertion loss requirements . 86
Table 63 – Return loss requirements . 87
Table 64 – Near-end cross talk requirements . 87
Table 65 – Far-end cross talk requirements . 87
Table 66 – Transverse conversion loss requirements . 88
Table 67 – Transverse conversion transfer loss requirements . 88
Table 68 – Transfer impedance requirements . 88
Table 69 – Coupling attenuation requirements . 89
Table 70 – Power sum alien NEXT requirements . 89
Table 71 – Power sum alien FEXT requirements . 89
Table 72 – Propagation delay requirements . 90
Table 73 – Number of cycles of mechanical operations . 90
Table 74 – Minimum axial test force . 91
Table 75 – Maximum insertion and withdrawal forces . 91
Table 76 – Polarization insertion force . 91
Table 77 – Maximum locking and unlocking torque . 92
Table 78 – Number of test specimens and contacts . 93
Table 79 – Test group P . 96
Table 80 – Test group AP . 96
Table 81 – Test group BP . 99
Table 82 – Test group CP . 100
Table 83 – Test group DP . 101
Table 84 – Test group EP . 101
Table 85 – Test group FP . 102
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
Connectors for electrical and electronic equipment -
Product requirements -
Part 2-118: Circular connectors - Detail specification for free and fixed
connectors with bayonet-locking size B12, B17, B23 and B40, for power,
signal and data transmission
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) IEC draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). IEC takes no position concerning the evidence, validity or applicability of any claimed patent rights in
respect thereof. As of the date of publication of this document, IEC had not received notice of (a) patent(s), which
may be required to implement this document. However, implementers are cautioned that this may not represent
the latest information, which may be obtained from the patent database available at https://patents.iec.ch. IEC
shall not be held responsible for identifying any or all such patent rights.
IEC 61076-2-118 has been prepared by subcommittee 48B: Electrical connectors, of IEC
technical committee 48: Electrical connectors and mechanical structures for electrical and
electronic equipment. It is an International Standard.
The text of this International Standard is based on the following documents:
Draft Report on voting
48B/3196/FDIS 48B/3205/RVD
Full information on the voting for its approval can be found in the report on voting indicated in
the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in
accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available
at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are
described in greater detail at www.iec.ch/publications.
A list of all parts in the IEC 61076 series, published under the general title Connectors for
electrical and electronic equipment - Product requirements, can be found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under webstore.iec.ch in the data related to the
specific document. At this date, the document will be
– reconfirmed,
– withdrawn, or
– revised.
INTRODUCTION
IEC SC 48B – Electrical connectors IEC 61076-2-118 ED1
Specification available from:
IEC General secretariat
or from the addresses shown on the inside cover.
DETAIL SPECIFICATION in accordance with IEC 61076-1
Circular connectors
With bayonet-locking
Size B12, B17, B23 and
B40, for power, signal and
data transmission
B12: 2-way power, 2 or
4-way data;
B17: 2 to 5-way power, 0 or
2-way signal, 2 or 4-way
data;
B23: 4 or 5-way power, 0 or
2-way signal, 2 or 4-way
data;
B40: 5-way power, 2 or
4-way data
Female (power and signal) +
male (data) and male (power
and signal) + female (data)
connectors
Female (power and signal)
+ female (data) and male
(power and signal) + male
(data) connectors
Male and female contacts
Rewirable
Non-rewirable
Free connectors, straight
and angled
Fixed connectors, flange
mounting and single hole
mounting
___________
Under preparation. Stage at the time of publication: IEC CDV 61076-1:2026.
1 Scope
This part of IEC 61076 specifies circular connectors with bayonet locking size B12, B17, B23
and B40, typically used for power, signal and data transmissions in industrial applications.
These connectors consist of fixed and free connectors either rewirable or non-rewirable.
NOTE B indicates that the connector is equipped with bayonet locking, while 12, 17, 23, 40 are the approximate
dimensions in millimetres of the contact carrier diameter of these circular connectors.
Power contacts of male connectors are round contacts with Ø 1 mm, Ø 1,5 mm, Ø 1,8 mm,
Ø 2,25 mm and Ø 4 mm, with current ratings up to 64 A per pole and rated voltage of 50 V,
300 V or 600 V AC/DC. Power contact groups are classified by type and identified throughout
this document as “P” followed by two digits “01” through “09” (see 4.3, Table 1).
Signal contacts of male connectors are round contacts with Ø 1 mm and Ø 1,8 mm, with current
ratings up to 20 A per pole and rated voltage of 50 V AC/DC. Signal contact groups are classified
by type and identified throughout this document as “S” followed by “0”, “1”, or “2” (see 4.3,
Table 2).
Male data contacts are round with Ø 0,8 mm and Ø 1 mm, with current ratings up to 4 A and
rated voltage of 50 V AC/DC, Data modules are classified by type and identified throughout this
document as “D” followed by “1”, or “2” (see 4.3, Table 3). D1 modules provide data
transmission with frequencies from 1 MHz to 100 MHz; D2 modules provide data transmission
with frequencies from 0,1 MHz to 600 MHz.
Besides the size of their bayonet locking (B12, B17, B23 or B40), connectors according to this
document can be identified by data module (D) and complementing power (P) and signal (S)
contact groups and optionally by number of poles, and finally by their application.
These connectors are designated for two main target applications, which differ as follows:
– Application A is for data transmission with power over data.
– Application B is for data transmission without power over data.
Connectors with power, signal and data contacts of the same gender are intended to also
transmit power over the data contacts (application A), while connectors with data contacts not
of the same gender of power and signal contacts are not intended to transmit power over the
data contacts (application B).
The codings provided by this document prevent the mating to any other connector with similarly
sized interfaces covered by this document.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies.
For undated references, the latest edition of the referenced document (including any
amendments) applies.
IEC 60068-1, Environmental testing - Part 1: General and guidance
IEC 60352 (all parts), Solderless connections
IEC 60512-1, Connectors for electrical and electronic equipment - Tests and measurements -
Part 1: Generic specification
IEC 60512-1-1, Connectors for electronic equipment - Tests and measurements - Part 1-1:
General examination - Test 1a: Visual examination
IEC 60512-1-2, Connectors for electronic equipment - Tests and measurements - Part 1-2:
General examination - Test 1b: Examination of dimension and mass
IEC 60512-2-1, Connectors for electronic equipment - Tests and measurements - Part 2-1:
Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level
method
IEC 60512-2-5, Connectors for electronic equipment - Tests and measurements - Part 2-5:
Electrical continuity and contact resistance tests - Test 2e: Contact disturbance
IEC 60512-3-1, Connectors for electronic equipment - Tests and measurements - Part 3-1:
Insulation tests - Test 3a: Insulation resistance
IEC 60512-4-1, Connectors for electronic equipment - Tests and measurements - Part 4-1:
Voltage stress tests - Test 4a: Voltage proof
IEC 60512-5-1, Connectors for electronic equipment - Tests and measurements - Part 5-1:
Current-carrying capacity tests - Test 5a: Temperature rise
IEC 60512-6-3, Connectors for electronic equipment - Tests and measurements - Part 6-3:
Dynamic stress tests - Test 6c: Shock
IEC 60512-6-4, Connectors for electronic equipment - Tests and measurements - Part 6-4:
Dynamic stress tests - Test 6d: Vibration (sinusoidal)
IEC 60512-9-1, Connectors for electronic equipment - Tests and measurements - Part 9-1:
Endurance tests - Test 9a: Mechanical operation
IEC 60512-9-2, Connectors for electronic equipment - Tests and measurements - Part 9-2:
Endurance tests - Test 9b: Electrical load and temperature
IEC 60512-11-1, Connectors for electrical and electronic equipment - Tests and
measurements - Part 11-1: Climatic tests - Test 11a - Climatic sequence
IEC 60512-11-4, Connectors for electronic equipment - Tests and measurements - Part 11-4:
Climatic tests - Test 11d: Rapid change of temperature
IEC 60512-11-9, Connectors for electronic equipment - Tests and measurements - Part 11-9:
Climatic tests - Test 11i: Dry heat
IEC 60512-11-10, Connectors for electronic equipment - Tests and measurements - Part 11-10:
Climatic tests - Test 11j: Cold
IEC 60512-11-12, Connectors for electronic equipment - Tests and measurements - Part 11-12:
Climatic tests - Test 11m: Damp heat, cyclic
IEC 60512-13-2, Connectors for electronic equipment - Tests and measurements - Part 13-2:
Mechanical operation tests - Test 13b: Insertion and withdrawal forces
IEC 60512-13-5, Connectors for electronic equipment - Tests and measurements - Part 13-5:
Mechanical operation tests - Test 13e: Polarizing and keying method
IEC 60512-16-5, Connectors for electronic equipment - Tests and measurements - Part 16-5:
Mechanical tests on contacts and terminations - Test 16e: Gauge retention force (resilient
contacts)
IEC 60512-28-100, Connectors for electrical and electronic equipment - Tests and
measurements - Part 28-100: Signal integrity tests up to 2 000 MHz - Tests 28a to 28g
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60529:1989/AMD1:1999
IEC 60529:1989/AMD2:2013
IEC 60664-1:2020, Insulation coordination for equipment within low-voltage supply systems -
Part 1: Principles, requirements and tests
IEC 60998-2-1, Connecting devices for low-voltage circuits for household and similar
purposes - Part 2-1: Particular requirements for connecting devices as separate entities with
screw-type clamping units
IEC 60999-1, Connecting devices - Electrical copper conductors - Safety requirements for
screw-type and screwless-type clamping units - Part 1: General requirements and particular
2 2
up to 35 mm (included)
requirements for clamping units for conductors from 0,2 mm
IEC 61076-1 , Connectors for electronic equipment - Product requirements - Part 1: Generic
specification
IEC 61984:2008, Connectors - Safety requirements and tests
ISO 21920-1, Geometrical product specifications (GPS) - Surface texture: Profile - Part 1:
Indication of surface texture
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61076-1,
IEC 61076-2, IEC 60512-1, IEC 61984 and the following apply.
ISO and IEC maintain terminology databases for use in standardization at the following
addresses:
– IEC Electropedia: available at https://www.electropedia.org/
– ISO Online browsing platform: available at https://www.iso.org/obp
3.1
PE
protective conductor
conductor provided for purposes of safety, for example protection against electric shock
Note 1 to entry: In an electrical installation, the conductor identified PE is normally also considered as protective
earthing conductor.
[SOURCE: IEC 60050-581:2008, 581-27-26]
___________
Under preparation. Stage at the time of publication: IEC CDV 61076-1:2026.
3.2
mounting orientation
circular mounting position of the connector in relation to the polarization of the mating interface
Note 1 to entry: Where the free connector has an angled cable entry (as opposed to a straight cable entry), the
angle between the cable entry direction and the polarization keyway should be specified.
4 Technical information
4.1 Systems of levels
4.1.1 Performance levels
Performance levels for these connectors are specified in 6.6.1, Table 73.
4.1.2 Compatibility levels
Connectors according to this document are intermateable according to IEC 61076-1.
4.2 Classification into climatic categories
Classification into climatic categories is specified in 6.3, Table 59.
4.3 Current-carrying capacity
The current rating of each connector part (power, signal, data) shall be as specified in Table 1,
Table 2 and Table 3, respectively.
All contact groups and all contacts in each group, except the PE where present, shall be
concurrently loaded, each at its rated current.
NOTE The rated current is defined for an ambient temperature of 40 °C.
Table 1 – Ratings of connector power part
Type Number of Function Male Rated voltage Rated current
contacts contact Ø
AC or DC
mm V A
P01 2-pin 2 1 50 8
P02 3-pin 2 + PE 1,8 300 20
P03 3-pin 2 + PE 16
P04 4-pin 3 + PE
1,5 14
P05 5-pin 4 + PE
P06 4-pin 3 + PE 600 12
P07 5-pin
...
IEC 61076-2-118 ®
Edition 1.0 2026-08
NORME
INTERNATIONALE
Connecteurs pour équipements électriques et électroniques – Exigences de
produit -
Partie 2-118: Connecteurs circulaires - Spécification particulière relative aux
fiches et embases écrantées ou non écrantées avec verrouillage à baïonnette,
des tailles B12, B17, B23 et B40, pour la transmission de signaux, de puissance
et de données
ICS 31.220.10 ISBN 978-2-8327-1466-9
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et
les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.
IEC Secretariat Tel.: +41 22 919 02 11
3, rue de Varembé info@iec.ch
CH-1211 Geneva 20 www.iec.ch
Switzerland
A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Recherche de publications IEC - IEC Products & Services Portal - products.iec.ch
webstore.iec.ch/advsearchform Découvrez notre puissant moteur de recherche et consultez
La recherche avancée permet de trouver des publications gratuitement tous les aperçus des publications, symboles
IEC en utilisant différents critères (numéro de référence, graphiques et le glossaire. Avec un abonnement, vous aurez
texte, comité d’études, …). Elle donne aussi des toujours accès à un contenu à jour adapté à vos besoins.
informations sur les projets et les publications remplacées
ou retirées. Electropedia - www.electropedia.org
Le premier dictionnaire d'électrotechnologie en ligne au
IEC Just Published - webstore.iec.ch/justpublished monde, avec plus de 22 500 articles terminologiques en
Restez informé sur les nouvelles publications IEC. Just anglais et en français, ainsi que les termes équivalents
dans 25 langues additionnelles. Egalement appelé
Published détaille les nouvelles publications parues.
Disponible en ligne et une fois par mois par email. Vocabulaire Electrotechnique International (IEV) en ligne.
Service Clients - webstore.iec.ch/csc
Si vous désirez nous donner des commentaires sur cette
publication ou si vous avez des questions contactez-
nous: sales@iec.ch.
SOMMAIRE
AVANT-PROPOS . 7
INTRODUCTION . 9
1 Domaine d’application . 10
2 Références normatives . 11
3 Termes et définitions . 13
4 Données techniques . 13
4.1 Systèmes de niveaux . 13
4.1.1 Niveaux de performance . 13
4.1.2 Niveaux de compatibilité . 13
4.2 Classification en catégories climatiques . 13
4.3 Courant admissible . 13
4.4 Désignation de type . 15
4.5 Marquage . 17
4.6 Aspects de la sécurité . 17
5 Informations relatives aux dimensions . 17
5.1 Généralités . 17
5.2 Description des modèles et des variantes . 17
5.2.1 Généralités . 17
5.2.2 Terminaisons . 17
5.2.3 Embases . 17
5.2.4 Fiches . 22
5.3 Dimensions d’interface . 31
5.3.1 Dimensions d’interface – B12 . 31
5.3.2 Dimensions d’interface – B17 . 38
5.3.3 Dimensions d’interface – B23 . 56
5.3.4 Dimensions d’interface – B40 . 67
5.3.5 Dimensions d’interface – Module de données trapézoïdal . 76
5.3.6 Sens de l’accouplement . 79
5.4 Calibres . 83
6 Caractéristiques . 84
6.1 Généralités . 84
6.2 Affectation des contacts et autres définitions . 84
6.3 Classification en catégories climatiques . 84
6.4 Caractéristiques électriques . 85
6.4.1 Généralités . 85
6.4.2 Tension de tenue . 85
6.4.3 Tension assignée de tenue aux chocs – Degré de pollution . 86
6.4.4 Courant admissible – échauffement . 86
6.4.5 Résistance de contact et de blindage . 87
6.4.6 Résistance d’isolement . 87
6.5 Performances de transmission . 87
6.5.1 Généralités . 87
6.5.2 Perte d’insertion . 87
6.5.3 Affaiblissement de réflexion . 88
6.5.4 Paradiaphonie (NEXT) . 88
6.5.5 Télédiaphonie (FEXT) . 88
6.5.6 Perte de conversion transverse (TCL). 89
6.5.7 Perte de transfert de conversion transverse (TCTL ) . 89
6.5.8 Impédance de transfert . 89
6.5.9 Affaiblissement de couplage . 90
6.5.10 Puissance cumulée de paradiaphonie exogène (PS NEXT) . 90
6.5.11 Puissance cumulée de télédiaphonie exogène (PS AFEXT) . 90
6.5.12 Temps de propagation . 91
6.6 Caractéristiques mécaniques . 91
6.6.1 Manœuvres mécaniques . 91
6.6.2 Efficacité des dispositifs d’accouplement des connecteurs . 91
6.6.3 Forces d’insertion et d’extraction . 92
6.6.4 Polarisation et détrompage . 92
6.7 Autres caractéristiques . 93
6.7.1 Vibrations (sinusoïdales) . 93
6.7.2 Chocs . 93
6.7.3 Degré de protection procuré par les enveloppes (code IP) . 93
6.7.4 Couple de verrouillage et de déverrouillage . 93
6.7.5 Aspects environnementaux – Marquage des matériaux isolants
(plastiques) . 93
7 Programme d’essais . 94
7.1 Généralités . 94
7.1.1 Vue d’ensemble . 94
7.1.2 Catégorie climatique . 94
7.1.3 Montage pour les mesures de la résistance de contact . 94
7.1.4 Montage pour les essais de contrainte dynamique (vibrations) . 95
7.1.5 Câblage des spécimens . 96
7.2 Programme d’essais . 97
7.2.1 Groupe d’essais P – Essais préliminaires . 97
7.2.2 Groupe d’essais AP – Dynamique/climatique . 97
7.2.3 Groupe d’essais BP – Endurance mécanique . 101
7.2.4 Groupe d’essais CP – Charge électrique . 102
7.2.5 Groupe d’essais DP – Essais de méthode de connexion . 103
7.2.6 Groupe d’essais EP – Exigences d’intégrité des signaux . 103
7.2.7 Groupe d’essais FP – Courant admissible . 104
Bibliographie . 105
Figure 1 – Embase, avec extrémités de fils, contacts de puissance mâles, contacts de
données mâles, encoche de verrouillage à baïonnette, et montage avant à bride carrée. 18
Figure 2 – Embase, avec extrémités de fils, contacts de puissance mâles, contacts de
données mâles, encoche de verrouillage à baïonnette, montage avant par écrou,
et rainure de détrompage . 19
Figure 3 – Embase, avec extrémités de fils, contacts de puissance mâles, contacts de
données mâles, encoche de verrouillage à baïonnette, montage arrière par écrou,
et rainure de détrompage . 20
Figure 4 – Embase, avec extrémités de fils, contacts de puissance femelles, contacts
de données femelles, encoche de verrouillage à baïonnette, et montage avant à bride
carrée . 20
Figure 5 – Embase, avec extrémités de fils, contacts de puissance femelles, contacts
de données femelles, encoche de verrouillage à baïonnette, montage avant par écrou,
et rainure de détrompage . 21
Figure 6 – Embase, avec extrémités de fils, contacts de puissance femelles, contacts
de données femelles, encoche de verrouillage à baïonnette, montage arrière par
écrou, et rainure de détrompage . 22
Figure 7 – Connecteur démontable, mâle, version à sortie droite, avec écrou de
verrouillage à baïonnette . 23
Figure 8 – Connecteur démontable, mâle, version à sortie coudée, avec écrou de
verrouillage à baïonnette . 24
Figure 9 – Connecteur non démontable, mâle, version à sortie droite, avec écrou de
verrouillage à baïonnette . 25
Figure 10 – Connecteur non démontable, mâle, version à sortie coudée, avec écrou de
verrouillage à baïonnette . 25
Figure 11 – Connecteur démontable, mâle, version à sortie droite, avec encoche de
verrouillage à baïonnette . 26
Figure 12 – Connecteur non démontable, mâle, version à sortie droite, avec encoche
de verrouillage à baïonnette . 27
Figure 13 – Connecteur démontable, femelle, version à sortie droite, avec écrou de
verrouillage à baïonnette . 27
Figure 14 – Connecteur démontable, femelle, version à sortie coudée, avec écrou de
verrouillage à baïonnette . 28
Figure 15 – Connecteur non démontable, femelle, version à sortie droite, avec écrou
de verrouillage à baïonnette . 28
Figure 16 – Connecteur non démontable, femelle, version à sortie coudée, avec écrou
de verrouillage à baïonnette . 29
Figure 17 – Connecteur démontable, femelle, version à sortie droite, avec encoche de
verrouillage à baïonnette . 30
Figure 18 – Connecteur non démontable, femelle, version à sortie droite, avec
encoche de verrouillage à baïonnette . 30
Figure 19 – Dimensions du positionnement des contacts de type B1201011 . 32
Figure 20 – Dimensions du positionnement des contacts de type B1201012 . 33
Figure 21 – Dimension du verrouillage à baïonnette B12 (2 rainures à baïonnette) . 36
Figure 22 – Dimensions du positionnement des contacts de type B1702011 . 38
Figure 23 – Dimensions du positionnement des contacts de type B1702012 . 39
Figure 24 – Dimensions du positionnement des contacts de type B1703011 . 41
Figure 25 – Dimensions du positionnement des contacts de type B1703012 . 42
Figure 26 – Dimensions du positionnement des contacts de type B1704011 . 44
Figure 27 – Dimensions du positionnement des contacts de type B1704012 . 45
Figure 28 – Dimensions du positionnement des contacts de type B1705011 . 47
Figure 29 – Dimensions du positionnement des contacts de type B1705012 . 48
Figure 30 – Dimensions du positionnement des contacts de type B1706211 . 50
Figure 31 – Dimensions du positionnement des contacts de type B1706212 . 51
Figure 32 – Dimension du verrouillage à baïonnette B17 (2 rainures à baïonnette) . 54
Figure 33 – Dimensions du positionnement des contacts de type B2307011 . 57
Figure 34 – Dimensions du positionnement des contacts de type B2307012 . 58
Figure 35 – Dimensions du positionnement des contacts de type B2308111 . 61
Figure 36 – Dimensions du positionnement des contacts de type B2308112 . 62
Figure 37 – Dimension du verrouillage à baïonnette B23 (2 rainures à baïonnette) . 65
Figure 38 – Dimensions du positionnement des contacts de type B4009011 . 68
Figure 39 – Dimensions du positionnement des contacts de type B4009012 . 69
Figure 40 – Dimension du verrouillage à baïonnette B40 (3 rainures à baïonnette) . 72
Figure 41 – Dimensions du positionnement des contacts et section du module de
données D1 . 76
Figure 42 – Zone de contact électrique du blindage du module de données blindé D1 . 77
Figure 43 – Dimensions du positionnement des contacts et de la section du module de
données D2 . 78
Figure 44 – Zone de contact électrique du blindage du module de données blindé D2 . 79
Figure 45 – Informations relatives à l’accouplement . 80
Figure 46 – Dimensions du calibre . 84
Figure 47 – Montage pour l’essai de la résistance de contact . 95
Figure 48 – Montage d’essai de contraintes dynamiques . 96
Tableau 1 – Caractéristiques assignées de la partie puissance du connecteur . 14
Tableau 2 – Caractéristiques assignées de la partie signaux du connecteur . 14
Tableau 3 – Caractéristiques assignées de la partie données du connecteur (module
de données) . 14
Tableau 4 – Désignation du type . 15
Tableau 5 – Combinaisons possibles de puissance, signaux et données . 16
Tableau 6 – Modèles d’embases . 18
Tableau 7 – Dimensions du modèle DM . 18
Tableau 8 – Dimensions du modèle EM . 19
Tableau 9 – Dimensions du modèle FM . 20
Tableau 10 – Dimensions du modèle DF . 21
Tableau 11 – Dimensions du modèle EF . 21
Tableau 12 – Dimensions du modèle FF . 22
Tableau 13 – Modèles de fiches. 23
Tableau 14 – Dimensions du modèle GM . 24
Tableau 15 – Dimensions du modèle HM . 24
Tableau 16 – Dimensions du modèle IM. 25
Tableau 17 – Dimensions du modèle JM . 26
Tableau 18 – Dimensions du modèle KM . 26
Tableau 19 – Dimensions du modèle LM . 27
Tableau 20 – Dimensions du modèle GF . 27
Tableau 21 – Dimensions du modèle HF . 28
Tableau 22 – Dimensions du modèle IF . 29
Tableau 23 – Dimensions du modèle JF. 29
Tableau 24 – Dimensions du modèle KF . 30
Tableau 25 – Dimensions du modèle LF . 31
Tableau 26 – Dimensions du positionnement des contacts de type B12010 . 34
Tableau 27 – Type de B12 combiné avec D1 et D2 de l’application A . 35
Tableau 28 – Type de B12 combiné avec D1 et D2 de l’application B . 35
Tableau 29 – Dimensions du verrouillage à baïonnette B12 . 36
Tableau 30 – Connecteurs B12 à détrompage mécanique . 37
Tableau 31 – Dimensions des détrompages mécaniques B12 . 37
Tableau 32 – Dimensions du positionnement des contacts de type B17020 . 40
Tableau 33 – Dimensions du positionnement des contacts de type B17030 . 43
Tableau 34 – Dimensions du positionnement des contacts de type B17040 . 46
Tableau 35 – Dimensions du positionnement des contacts de type B17050 . 49
Tableau 36 – Dimensions du positionnement des contacts de type B17062 . 52
Tableau 37 – Types de B17 combiné avec D1 et D2 de l’application A . 53
Tableau 38 – Types de B17 combiné avec D1 et D2 de l’application B . 53
Tableau 39 – Dimensions du verrouillage à baïonnette B17 . 54
Tableau 40 – Connecteurs B17 à détrompage mécanique . 55
Tableau 41 – Dimensions des détrompages mécaniques B17 . 56
Tableau 42 – Dimensions du positionnement des contacts de type B23070 . 59
Tableau 43 – Dimensions du positionnement des contacts de type B23081 . 63
Tableau 44 – Types de B23 combiné avec D1 et D2 de l’application A . 64
Tableau 45 – Types de B23 combinés avec D1 de l’application B . 65
Tableau 46 – Dimensions du verrouillage à baïonnette B23 . 66
Tableau 47 – Connecteurs de B23 à détrompage mécanique . 66
Tableau 48 – Dimensions des détrompages mécaniques B23 . 67
Tableau 49 – Dimensions du positionnement des contacts de type B40090 . 70
Tableau 50 – Type de B40 combiné avec D1 et D2 de l’application A . 71
Tableau 51 – Type de B40 combiné avec D1 et D2 de l’application B . 71
Tableau 52 – Dimensions du verrouillage à baïonnette B40 . 73
Tableau 53 – Connecteurs de B40 à détrompage mécanique . 73
Tableau 54 – Dimensions des détrompages mécaniques B40 . 75
Tableau 55 – Dimensions du positionnement des contacts du module de données D1 . 77
Tableau 56 – Dimensions de positionnement des contacts du module de données D2 . 79
Tableau 57 – Dimensions des connecteurs en position accouplée et verrouillée . 80
Tableau 58 – Calibres . 84
Tableau 59 – Catégorie climatique . 85
Tableau 60 – Tenue en tension . 85
Tableau 61 – Tension de choc assignée et degré de pollution . 86
Tableau 62 – Exigences relatives à la perte d’insertion . 87
Tableau 63 – Exigences relatives à l’affaiblissement de réflexion . 88
Tableau 64 – Exigences relatives à la paradiaphonie . 88
Tableau 65 – Exigences relatives à la télédiaphonie . 88
Tableau 66 – Exigences relatives à la perte de conversion transverse . 89
Tableau 67 – Exigences relatives à la perte de transfert de conversion transverse . 89
Tableau 68 – Exigences relatives à l’impédance de transfert . 89
Tableau 69 – Exigences relatives à l’affaiblissement de couplage . 90
Tableau 70 – Exigences relatives à la puissance cumulée de paradiaphonie exogène . 90
Tableau 71 – Exigences relatives à la puissance cumulée de paradiaphonie exogène . 90
Tableau 72 – Exigences relatives au temps de propagation . 91
Tableau 73 – Nombre de manœuvres mécaniques . 91
Tableau 74 – Force d’essai axiale minimale . 92
Tableau 75 – Forces d’insertion et d’extraction maximales. 92
Tableau 76 – Force d’insertion de détrompage . 92
Tableau 77 – Couple maximal de verrouillage et de déverrouillage . 93
Tableau 78 – Nombre de spécimens et de contacts . 94
Tableau 79 – Groupe d’essais P . 97
Tableau 80 – Groupe d’essais AP . 97
Tableau 81 – Groupe d’essais BP . 101
Tableau 82 – Groupe d’essais CP . 102
Tableau 83 – Groupe d’essais DP . 103
Tableau 84 – Groupe d’essais EP . 103
Tableau 85 – Groupe d’essais FP . 104
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
Connecteurs pour équipements électriques et électroniques -
Exigences de produit -
Partie 2-118: Connecteurs circulaires - Spécification particulière relative
aux fiches et embases écrantées ou non écrantées avec verrouillage à
baïonnette, des tailles B12, B17, B23 et B40, pour la transmission de
signaux, de puissance et de données
AVANT-PROPOS
1) La Commission Électrotechnique Internationale (IEC) est une organisation mondiale de normalisation composée
de l’ensemble des comités électrotechniques nationaux (Comités nationaux de l’IEC). L’IEC a pour objet de
favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de
l’électricité et de l’électronique. À cet effet, l’IEC – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de l’IEC"). Leur élaboration est confiée à des comités d’études,
aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec l’IEC, participent également aux
travaux. L’IEC collabore étroitement avec l’Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de l’IEC concernant les questions techniques représentent, dans la mesure du
possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de l’IEC intéressés
sont représentés dans chaque comité d’études.
3) Les Publications de l’IEC se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de l’IEC. Tous les efforts raisonnables sont entrepris afin que l’IEC
s’assure de l’exactitude du contenu technique de ses publications; l’IEC ne peut pas être tenue responsable de
l’éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d’encourager l’uniformité internationale, les Comités nationaux de l’IEC s’engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de l’IEC dans leurs publications nationales
et régionales. Toutes divergences entre toutes Publications de l’IEC et toutes publications nationales ou
régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) L’IEC elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d’évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de l’IEC. L’IEC n’est responsable d’aucun des services effectués par les organismes de certification
indépendants.
6) Tous les utilisateurs doivent s’assurer qu’ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à l’IEC, à ses administrateurs, employés, auxiliaires ou mandataires,
y compris ses experts particuliers et les membres de ses comités d’études et des Comités nationaux de l’IEC,
pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque
nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les dépenses
découlant de la publication ou de l’utilisation de cette Publication de l’IEC ou de toute autre Publication de l’IEC,
ou au crédit qui lui est accordé.
8) L’attention est attirée sur les références normatives citées dans cette publication. L’utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’IEC attire l’attention sur le fait que la mise en application du présent document peut entraîner l’utilisation d’un
ou de plusieurs brevets. L’IEC ne prend pas position quant à la preuve, à la validité et à l’applicabilité de tout
droit de brevet revendiqué à cet égard. À la date de publication du présent document, l’IEC n’avait pas reçu
notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa mise en application. Toutefois, il y a lieu
d’avertir les responsables de la mise en application du présent document que des informations plus récentes
sont susceptibles de figurer dans la base de données de brevets, disponible à l’adresse https://patents.iec.ch.
L’IEC ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de brevet.
L’IEC 61076-2-118 a été établie par le sous-comité 48B: Connecteurs électriques, du comité
d’études 48 de l’IEC: Connecteurs électriques et structures mécaniques pour les équipements
électriques et électroniques. Il s’agit d’une Norme internationale.
Le texte de cette Norme internationale est issu des documents suivants:
Projet Rapport de vote
48B/3196/FDIS 48B/3205/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à son approbation.
La langue employée pour l’élaboration de cette Norme internationale est l’anglais.
Ce document a été rédigé selon les Directives ISO/IEC, Partie 2, il a été développé selon les
Directives ISO/IEC, Partie 1 et les Directives ISO/IEC, Supplément IEC, disponibles sous
www.iec.ch/members_experts/refdocs. Les principaux types de documents développés par
l’IEC sont décrits plus en détail sous www.iec.ch/publications.
Une liste de toutes les parties de la série IEC 61076, publiées sous le titre général Connecteurs
pour équipements électriques et électroniques - Exigences de produit, se trouve sur le site web
de l’IEC.
Le comité a décidé que le contenu de ce document ne sera pas modifié avant la date de stabilité
indiquée sur le site web de l’IEC sous webstore.iec.ch dans les données relatives au document
recherché. À cette date, le document sera:
– reconduit,
– supprimé, ou
– révisé.
INTRODUCTION
IEC SC 48B – Connecteurs électriques IEC 61076-2-118 Éd.1
Spécification disponible:
Secrétariat Général de l’IEC ou aux adresses indiquées à l’intérieur de la page
de couverture.
SPÉCIFICATION PARTICULIÈRE conformément à
l’IEC 61076-1
Connecteurs circulaires
Avec verrouillage à
baïonnette
Des tailles B12, B17, B23 et
B40, pour la transmission
de signaux, de puissance et
de données
B12: puissance 2 directions,
données 2 ou 4 directions;
B17: puissance 2 à 5
directions, signaux 0 à 2
directions, données 2 ou 4
directions;
B23: puissance 4 ou 5
directions, signaux 0 à 2
directions, données 2 ou 4
directions;
B40: puissance 5 directions,
données 2 ou 4 directions
Connecteurs femelles
(puissance et signaux) +
mâles (données) et mâles
(puissance et signaux) +
femelles (données)
Connecteurs femelles
(puissance et signaux) +
femelles (données) et mâles
(puissance et signaux) +
mâles (données)
Contacts mâles et femelles
Démontables
Non démontables
Fiches, droites et coudées
Embases, montage à bride
et montage par écrou
___________
En cours de préparation. Statut au moment de la publication: IEC CDV 61076-1:2026.
1 Domaine d’application
La présente partie de l’IEC 61076 spécifie les connecteurs circulaires avec verrouillage à
baïonnette des tailles B12, B17, B23 et B40, qui sont généralement utilisés pour la transmission
de signaux, de puissance et de données dans des applications industrielles. Ces connecteurs
se composent d’embases et de fiches démontables ou non.
NOTE B indique que le connecteur est équipé d’un verrouillage à baïonnette, tandis que les chiffres 12, 17, 23 et
40 correspondent à la dimension approximative, en millimètres, du diamètre du support de contact de ces
connecteurs circulaires.
Les contacts de puissance des connecteurs mâles sont des contacts ronds de Ø 1 mm, Ø
1,5 mm, Ø 1,8 mm, Ø 2,25 mm et Ø 4 mm, avec des courants assignés allant jusqu’à 64 A par
pôle et une tension assignée de 50 V, 300 V ou 600 V en courant alternatif et en courant
continu. Les groupes de contacts de puissance sont classés par type et identifiés, dans le
présent document, "P" suivi de deux chiffres "01" à "09" (voir 4.3, Tableau 1).
Les contacts de signaux des connecteurs mâles sont des contacts ronds de Ø 1 mm et Ø
1,8 mm, avec des courants assignés allant jusqu’à 20 A par pôle et une tension assignée de
50 V en courant alternatif et en courant continu. Les groupes de contacts de signaux sont
classés par type et identifiés, dans le présent document, "S" suivi de "0", "1" ou "2" (voir 4.3,
Tableau 2).
Les contacts de données mâles sont des contacts ronds de Ø 0,8 mm et Ø 1 mm, avec des
courants assignés allant jusqu’à 4 A et une tension assignée de 50 V en courant alternatif et
en courant continu. Les modules de données sont classés par type et identifiés, dans la
présente norme, "D" suivi de "1" ou "2" (voir 4.3, Tableau 3). Les modules D1 offrent une
transmission de données de fréquences comprises entre 1 MHz et 100 MHz; les modules D2
offrent une transmission de données de fréquences comprises entre 0,1 MHz et 600 MHz.
Outre la taille de leur verrouillage à baïonnette (B12, B17, B23 ou B40), les connecteurs
conformes au présent document peuvent être identifiés par le module de données (D) et les
groupes de contacts de puissance (P) et de signaux (S), ainsi que facultativement par le nombre
de pôles, et enfin, par leur application.
Ces connecteurs sont conçus pour deux applications cibles principales, qui se distinguent
comme suit:
– l’application A est destinée à la transmission de données avec alimentation électrique par
câble de données;
– l’application B est destinée à la transmission de données sans alimentation électrique par
câble de données.
Les connecteurs avec contacts de puissance, de signaux et de données du même genre sont
destinés à transmettre également de la puissance sur les contacts de données (application A),
alors que les connecteurs avec contacts de données du genre opposé aux contacts de
puissance et de signaux ne sont pas destinés à transmettre de la puissance par les contacts
de données (application B).
Les différents détrompages prévus par le présent document empêchent l’accouplement avec
tout autre connecteur ayant une autre interface de taille semblable couverte par le présent
document.
2 Références normatives
Les documents suivants sont cités dans le texte de sorte qu’ils constituent, pour tout ou partie
de leur contenu, des exigences du présent document. Pour les références datées,
seule l’édition citée s’applique. Pour les références non datées, la dernière édition du document
de référence s’applique (y compris les éventuels amendements).
IEC 60068-1, Essais d’environnement - Partie 1: Généralités et lignes directrices
IEC 60352 (toutes les parties), Connexions sans soudure
IEC 60512 (toutes les parties), Connecteurs pour équipements électroniques - Essais et
mesures
IEC 60512-1, Connecteurs pour équipements électriques et électroniques - Essais et mesures -
Partie 1: Spécification générique
IEC 60512-1-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 1-1:
Examen général - Essai 1a: Examen visuel
IEC 60512-1-2, Connecteurs pour équipements électroniques - Essais et mesures - Partie 1-2:
Examen général - Essai 1b: Examen de dimension et masse
IEC 60512-2-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 2-1:
Essais de continuité électrique et de résistance de contact - Essai 2a: Résistance de contact -
Méthode du niveau des millivolts
IEC 60512-2-5, Connecteurs pour équipements électroniques - Essais et mesures - Partie 2-5:
Essais de continuité électrique et de résistance de contact - Essai 2e: Perturbation de contact
IEC 60512-3-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 3-1:
Essais d’isolement - Essai 3a: Résistance d’isolement
IEC 60512-4-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 4-1:
Essais de contrainte diélectrique - Essai 4a: Tension de tenue
IEC 60512-5-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 5-1:
Essais de courant limite - Essai 5a: Echauffement
IEC 60512-6-3, Connecteurs pour équipements électroniques - Essais et mesures - Partie 6-3:
Essais de contraintes dynamiques - Essai 6c: Chocs
IEC 60512-6-4, Connecteurs pour équipements électroniques - Essais et mesures - Partie 6-4:
Essais de contraintes dynamiques - Essai 6d: Vibrations (sinusoïdales)
IEC 60512-9-1, Connecteurs pour équipements électroniques - Essais et mesures - Partie 9-1:
Essais d’endurance - Essai 9a: Fonctionnement mécanique
IEC 60512-9-2, Connecteurs pour équipements électroniques - Essais et mesures - Partie 9-2:
Essais d’endurance - Essai 9b: Charge électrique et température
IEC 60512-11-1, Connecteurs pour équipements électriques et électroniques - Essais et
- Partie 11-1: Essais climatiques - Essai 11a: Séquence climatique
mesures
IEC 60512-11-4, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-4: Essais climatiques - Essai 11d: Variations rapides de température
IEC 60512-11-9, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-9: Essais climatiques - Essai 11i: Chaleur sèche
IEC 60512-11-10, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-10: Essais climatiques - Essai 11j: Froid
IEC 60512-11-12, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 11-12: Essais climatiques - Essai 11m: Essai cyclique de chaleur humide
IEC 60512-13-2, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 13-2: Essais de fonctionnement mécanique - Essai 13b: Forces d’insertion et d’extraction
IEC 60512-13-5, Connecteurs pour équipements électroniques - Essais et mesures -
Partie 13-5: Essais de fonctionnement mécanique - Essai 13e: Méthode de polarisation et de
coda
...