IEC 60947-5-8:2006
(Main)Low-voltage switchgear and controlgear - Part 5-8: Control circuit devices and switching elements - Three-position enabling switches
Low-voltage switchgear and controlgear - Part 5-8: Control circuit devices and switching elements - Three-position enabling switches
This part of IEC 60947 specifies requirements for three-position enabling switches.
Appareillage à basse tension - Partie 5-8: Appareils et éléments de commutation pour circuit de commande - Interrupteurs de commande de validation à trois positions
La présente partie de la CEI 60947 spécifie les exigences pour les interrupteurs de commande de validation à trois positions.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE
IEC
60947-5-8
INTERNATIONAL
Première édition
STANDARD
First edition
2006-10
Appareillage à basse tension –
Partie 5-8:
Appareils et éléments de
commutation pour circuit de commande –
Interrupteurs de commande de validation
à trois positions
Low-voltage switchgear and controlgear –
Part 5-8:
Control circuit devices and switching elements –
Three-position enabling switches
Numéro de référence
Reference number
CEI/IEC 60947-5-8:2006
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE
IEC
60947-5-8
INTERNATIONAL
Première édition
STANDARD
First edition
2006-10
Appareillage à basse tension –
Partie 5-8:
Appareils et éléments de
commutation pour circuit de commande –
Interrupteurs de commande de validation
à trois positions
Low-voltage switchgear and controlgear –
Part 5-8:
Control circuit devices and switching elements –
Three-position enabling switches
© IEC 2006 Droits de reproduction réservés ⎯ Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
S
PRICE CODE
Commission Electrotechnique Internationale
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60947-5-8 © CEI:2006
SOMMAIRE
AVANT-PROPOS.4
1 Généralités.8
1.1 Domaine d’application.8
1.2 Références normatives.8
2 Termes et définitions .10
3 Classification.12
3.1 Eléments de contact.12
3.2 Interrupteur de commande de validation à trois positions .12
4 Caractéristiques.12
4.1 Enumération des caractéristiques.12
4.2 Type d’interrupteur de commande de validation à trois positions .12
4.3 Valeurs assignées et valeurs limites pour les éléments de commutation.12
4.4 Catégories d’emploi des éléments de commutation .14
4.5 Disponible .14
4.6 Disponible .14
4.7 Disponible .14
4.8 Disponible .14
4.9 Surtensions de manœuvre.14
4.10 Séparation électrique des éléments de contact.14
5 Informations sur le matériel .14
5.1 Nature des informations.14
5.2 Marquage.16
5.3 Instructions d’installation, de fonctionnement et d’entretien .16
5.4 Informations complémentaires.16
6 Conditions normales de service, de montage et de transport .16
6.3 Montage.16
7 Dispositions relatives à la construction et au fonctionnement .18
7.1 Dispositions constructives .18
7.2 Dispositions relatives au fonctionnement.22
8 Essais.24
8.1 Nature des essais.24
8.2 Conformité aux dispositions constructives .26
8.3 Fonctionnement.26
Annexe A (informative) Exemple d’un appareil de commande de validation incorporant
un interrupteur de commande de validation à trois positions .38
Bibliographie.40
Figure 1 – Fonctionnement des interrupteurs de commande de validation à trois positions .20
Figure 2 – Effort de manœuvre, course et état du contact .22
Figure A.1 − Appareil de commande de validation.38
60947-5-8 © IEC:2006 – 3 –
CONTENTS
FOREWORD.5
1 General.9
1.1 Scope.9
1.2 Normative references.9
2 Terms and definitions .11
3 Classification.13
3.1 Contact elements.13
3.2 Three-position enabling switch.13
4 Characteristics.13
4.1 Summary of characteristics.13
4.2 Type of three-position enabling switch.13
4.3 Rated and limiting values for switching elements.13
4.4 Utilization categories for switching elements .15
4.5 Vacant.15
4.6 Vacant.15
4.7 Vacant.15
4.8 Vacant.15
4.9 Switching overvoltages.15
4.10 Electrically separated contact elements.15
5 Product information .15
5.1 Nature of information.15
5.2 Marking.17
5.3 Instructions for installation, operation and maintenance .17
5.4 Additional information.17
6 Normal service, mounting and transport conditions.17
6.3 Mounting.17
7 Constructional and performance requirements.19
7.1 Constructional requirements.19
7.2 Performance requirements .23
8 Tests.25
8.1 Kinds of test.25
8.2 Compliance with constructional requirements .27
8.3 Performance.27
Annex A (informative) Example of an enabling device incorporating a three-position
enabling switch .39
Bibliography.41
Figure 1 – Operation of three-position enabling switches .21
Figure 2 – Operating force, travel and contact status .23
Figure A.1 − Enabling device .39
– 4 – 60947-5-8 © CEI:2006
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
APPAREILLAGE Á BASSE TENSION –
Partie 5-8: Appareils et éléments de
commutation pour circuit de commande –
Interrupteurs de commande de validation
à trois positions
AVANT-PROPOS
1) La Commission Electrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de la CEI
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CEI. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes Publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) La CEI n’a prévu aucune procédure de marquage valant indication d’approbation et n'engage pas sa
responsabilité pour les équipements déclarés conformes à une de ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme internationale CEI 60947-5-8 a été établie par le sous-comité 17B: Appareillage à
basse tension, du comité d'études 17 de la CEI: Appareillage.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
17B/1492/FDIS 17B/1511/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
60947-5-8 © IEC:2006 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR –
Part 5-8: Control circuit devices and switching elements –
Three-position enabling switches
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60947-5-8 has been prepared by subcommittee 17B: Low-voltage
switchgear and controlgear, of IEC technical committee 17: Switchgear and controlgear.
The text of this standard is based on the following documents:
FDIS Report on voting
17B/1492/FDIS 17B/1511/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
– 6 – 60947-5-8 © CEI:2006
Cette norme internationale doit être utilisée conjointement avec la CEI 60947-1 et la
CEI 60947-5-1.
Les dispositions des règles générales, CEI 60947-1, sont applicables à la présente norme,
lorsque celle-ci le précise. Les articles et paragraphes des règles générales ainsi rendues
applicables, ainsi que les tableaux, figures et annexes, sont identifiés par référence à la
CEI 60947-1, par exemple 1.2.3 ou Annexe A de la CEI 60947-1.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
Une liste de toutes les parties de la série CEI 60947, présentées sous le titre général
Appareillage à basse tension, peut être consultée sur le site web de la CEI.
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60947-5-8 © IEC:2006 – 7 –
This International Standard should be used in conjunction with IEC 60947-1 and IEC 60947-5-1.
The provisions of the general rules, IEC 60947-1, are applicable to this standard, where
specifically called for. General rules clauses and subclauses thus applicable, as well as
tables, figures and annexes are identified by a reference to IEC 60947-1, for example 1.2.3 or
Annex A of IEC 60947-1.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A list of all parts in the IEC 60947 series, under the general title Low-voltage swtichgear and
controlgear, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
– 8 – 60947-5-8 © CEI:2006
APPAREILLAGE À BASSE TENSION –
Partie 5-8: Appareils et éléments de
commutation pour circuit de commande –
Interrupteurs de commande de validation
à trois positions
1 Généralités
1.1 Domaine d’application
La présente partie de la CEI 60947 spécifie les exigences pour les interrupteurs de
commande de validation à trois positions.
Ces interrupteurs sont utilisés comme composants dans les appareils de commande de
validation décrits en 10.9 de la CEI 60204-1 pour fournir des signaux qui,
a) lorsqu’ils sont activés, permettent la mise en marche de la machine par une commande
séparée de démarrage, et
b) lorsqu’ils sont désactivés
i) initient une fonction d’arrêt, et
ii) évitent la mise en marche de la machine.
NOTE 1 La fonction de commande de validation est décrite en 9.2.6.3 de la CEI 60204-1.
NOTE 2 La présente norme ne traite pas des appareils de commande de validation.
La présente norme ne s’applique pas aux:
− interrupteurs de commande de validation à trois positions pour des circuits de commande
non électriques, par exemple hydrauliques, pneumatiques;
− interrupteurs de commande de validation sans mécanisme à trois positions;
− appareils d’arrêt d’urgence (voir la CEI 60947-5-5).
1.2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60068-2-1:1990, Essais d’environnement – Deuxième partie: Essais – Essai A: Froid
Amendement 1 (1993)
Amendement 2 (1994)
CEI 60068-2-2:1974, Essais d’environnement – Deuxième partie: Essais – Essai B: Chaleur
sèche
Amendement 1 (1993)
Amendement 2 (1994)
CEI 60068-2-6:1995, Essais d’environnement – Partie 2: Essais – Essai Fc: Vibrations
(sinusoïdales)
CEI 60068-2-27:1987, Essais d’environnement – Partie 2: Essais – Essai Ea et guide: Chocs
60947-5-8 © IEC:2006 – 9 –
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR –
Part 5-8: Control circuit devices and switching elements –
Three-position enabling switches
1 General
1.1 Scope
This part of IEC 60947 specifies requirements for three-position enabling switches.
These switches are used as components of enabling devices described in 10.9 of
IEC 60204-1 to provide signals that,
a) when activated, allow machine operation to be initiated by a separate start control, and
b) when de-activated,
i) initiate a stop function, and
ii) prevent initiation of machine operation.
NOTE 1 The enabling control function is described in 9.2.6.3 of IEC 60204-1.
NOTE 2 This standard does not deal with enabling devices.
This standard does not apply to:
− three-position enabling switches for non-electrical control circuits, for example hydraulic,
pneumatic;
− enabling switches without three-position mechanism;
− emergency stop devices (see IEC 60947-5-5).
1.2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-2-1:1990, Environmental testing – Part 2: Tests – Test A: Cold
Amendment 1 (1993)
Amendment 2 (1994)
IEC 60068-2-2:1974, Environmental testing – Part 2: Tests – Test B: Dry heat
Amendment 1 (1993)
Amendment 2 (1994)
IEC 60068-2-6:1995, Environmental testing – Part 2: Tests – Test Fc: Vibration (sinusoidal)
IEC 60068-2-27:1987, Environmental testing – Part 2: Tests – Test Ea and guidance: Shock
– 10 – 60947-5-8 © CEI:2006
CEI 60204-1:2005, Sécurité des machines – Equipement électrique des machines – Partie 1:
Règles générales
CEI 60947-1:2004, Appareillage à basse tension – Partie 1: Règles générales
CEI 60947-5-1:2003, Appareillage à basse tension – Partie 5-1: Appareils et éléments de
commutation pour circuits de commande – Appareils électromécaniques pour circuits de
commande
2 Termes et définitions
Pour les besoins du présent document, les définitions appropriées de l’Article 2 de la
CEI 60947-1 et de l’Article 2 de la CEI 60947-5-1 s’appliquent ainsi que les définitions
complémentaires suivantes.
Index alphabétique des définitions
Référence
A
Appareil de commande de validation. 2.1
C
Contact auxiliaire. 2.5
I
Interrupteur de commande de validation à trois positions. 2.2
M
Mécanisme transmetteur (d’un interrupteur de commande de validation à trois positions) 2.3
O
Organe de commande (d’un interrupteur de commande de validation à trois positions) 2.4
2.1
appareil de commande de validation
appareil de commande manuelle utilisé en conjonction avec une commande démarrage et,
lorsqu’il est continuellement activé, permet la mise en marche d’une machine
2.2
interrupteur de commande de validation à trois positions
interrupteur ayant trois positions séquentielles, dans lequel les contacts sont fermés lorsque
l’organe de commande est dans la position milieu (partiellement appuyé) et ouverts lorsque
l’organe de commande est dans la position repos (non appuyé) et dans la position totalement
appuyé
2.3
mécanisme transmetteur (d’un interrupteur de commande de validation à trois positions)
parties mécaniques qui transmettent l’effort de commande aux éléments de contact
[VEI 441-15-21, modifiée]
2.4
organe de commande (d’un interrupteur de commande de validation à trois positions)
partie du mécanisme transmetteur qui est activée par une partie du corps humain
EXEMPLE un bouton.
60947-5-8 © IEC:2006 – 11 –
IEC 60204-1:2005, Safety of machinery – Electrical equipment of machines – Part 1: General
requirements
IEC 60947-1:2004, Low-voltage switchgear and controlgear – Part 1: General rules
IEC 60947-5-1:2003, Low-voltage switchgear and controlgear – Part 5-1: Control circuit
devices and switching elements – Electromechanical control circuit devices
2 Terms and definitions
For the purposes of this document, the relevant definitions given in Clause 2 of IEC 60947-1
and Clause 2 of IEC 60947-5-1 apply, with the following additional definitions.
Alphabetical index of definitions
Reference
A
Actuating system (of a three-position enabling switch). 2.3
Actuator (of a three-position enabling switch) . 2.4
Auxiliary contact. 2.5
E
Enabling device. 2.1
T
Three-position enabling switch. 2.2
2.1
enabling device
manually operated control device used in conjunction with a start control and which, when
continuously actuated, allows a machine operation
2.2
three-position enabling switch
switch having three sequential actuator positions, in which the contacts are closed when the
actuator is in the mid position (partly depressed) and are open when the actuator is in the rest
(not pressed) position and in the fully depressed position
2.3
actuating system (of a three-position enabling switch)
mechanical parts which transmit the actuating force to the contact elements
[IEV 441-15-21, modified]
2.4
actuator (of a three-position enabling switch)
part of the actuating system which is actuated by a part of the human body
EXAMPLE a button.
– 12 – 60947-5-8 © CEI:2006
2.5
contact auxiliaire
contact d’un interrupteur de commande de validation à trois positions qui fournit une fonction
auxiliaire
NOTE Les contacts auxiliaires peuvent être normalement ouverts et/ou normalement fermés.
3 Classification
3.1 Eléments de contact
Le paragraphe 3.1 de la CEI 60947-5-1 s’applique.
3.2 Interrupteur de commande de validation à trois positions
Les interrupteurs de commande de validation à trois positions peuvent être classés en
fonction de leur élément de contact et de la nature de leur mécanisme transmetteur, par
exemple interrupteurs de commande de validation à trois positions, forme B.
4 Caractéristiques
4.1 Enumération des caractéristiques
Le paragraphe 4.1 de la CEI 60947-5-1 s’applique.
4.1.1 Fonctionnement d’un auxiliaire de commande
Le paragraphe 4.1.1 de la CEI 60947-5-1 s’applique.
4.1.1.1 Conditions normales d’emploi
Le paragraphe 4.1.1.1 de la CEI 60947-5-1 s’applique.
4.1.1.2 Conditions anormales d’emploi
Le paragraphe 4.1.1.2 de la CEI 60947-5-1 s’applique.
4.2 Type d’interrupteur de commande de validation à trois positions
4.2.1 Exemples d’appareils incorporant des interrupteurs de commande de validation
à trois positions
− boutons-poussoirs de commande de validation;
− poignée de commande de validation;
− pédale de commande de validation; etc.
4.2.2 Nombre de pôles
Le nombre de pôles doit être déclaré par le constructeur.
4.2.3 Nature du courant
Courant alternatif ou courant continu.
4.3 Valeurs assignées et valeurs limites pour les éléments de commutation
Le paragraphe 4.3 de la CEI 60947-5-1 s’applique.
60947-5-8 © IEC:2006 – 13 –
2.5
auxiliary contact
contact of a three-position enabling switch that provides an auxiliary function
NOTE Auxiliary contacts may be normally open and/or normally closed.
3 Classification
3.1 Contact elements
Subclause 3.1 of IEC 60947-5-1 applies.
3.2 Three-position enabling switch
Three-position enabling switches may be classified according to the contact element and the
nature of the actuating system, e.g. three-position enabling switches, form B.
4 Characteristics
4.1 Summary of characteristics
Subclause 4.1 of IEC 60947-5-1 applies.
4.1.1 Operation of a control switch
Subclause 4.1.1 of IEC 60947-5-1 applies.
4.1.1.1 Normal conditions of use
Subclause 4.1.1.1 of IEC 60947-5-1 applies.
4.1.1.2 Abnormal conditions of use
Subclause 4.1.1.2 of IEC 60947-5-1 applies.
4.2 Type of three-position enabling switch
4.2.1 Examples of devices incorporating three-position enabling switches
− push-button enabling devices;
− grip actuated enabling devices;
− foot actuated enabling devices; etc.
4.2.2 Number of poles
The number of poles shall be stated by the manufacturer.
4.2.3 Kind of current
Alternating current or direct current.
4.3 Rated and limiting values for switching elements
Subclause 4.3 of IEC 60947-5-1 applies.
– 14 – 60947-5-8 © CEI:2006
4.4 Catégories d’emploi des éléments de commutation
Le paragraphe 4.4 de la CEI 60947-5-1 s’applique.
4.5 Disponible
4.6 Disponible
4.7 Disponible
4.8 Disponible
4.9 Surtensions de manœuvre
Le paragraphe 4.9 de la CEI 60947-1 s’applique.
4.10 Séparation électrique des éléments de contact
Le paragraphe 4.10 de la CEI 60947-5-1 s’applique.
5 Informations sur le matériel
5.1 Nature des informations
Les informations suivantes doivent être données par le constructeur:
Identification
a) Nom du constructeur ou marque de fabrique.
b) Désignation du type ou numéro de série permettant d’obtenir les renseignements relatifs à
l’élément de commutation (ou à l’auxiliaire de commande complet) auprès du constructeur.
c) «CEI 60947-5-8» si le constructeur déclare la conformité à la présente norme.
d) Les interrupteurs de commande de validation à trois positions doivent être marqués d’une
manière indélébile et lisible par le symbole:
NOTE Si, pour des raisons de taille, il n’est pas possible d’apposer le marquage sur l’interrupteur, alors le
symbole peut être mis dans les instructions d’installation, de fonctionnement et d’entretien.
Valeurs assignées et emplois fondamentaux
e) Efforts de commande et course de fonctionnement.
f) Tensions assignées d’emploi (voir 4.3.1.1 de la CEI 60947-5-1).
g) Catégorie d'emploi et courants assignés d'emploi aux tensions assignées d'emploi de
l’élément de commutation.
h) Tension assignée d’isolement (voir 4.3.1.2 de la CEI 60947-5-1).
i) Tension assignée de tenue aux chocs U conformément à 4.3.1.3 de la CEI 60947-1.
imp
j) Code IP (voir 5.1 et l’Annexe C de la CEI 60947-1).
k) Degré de pollution (voir 6.1.3.2 de la CEI 60947-5-1).
l) Type et valeurs maximales des caractéristiques assignées des dispositifs de protection
contre les courts-circuits (voir 8.3.4.3 de la CEI 60947-5-1).
60947-5-8 © IEC:2006 – 15 –
4.4 Utilization categories for switching elements
Subclause 4.4 of IEC 60947-5-1 applies.
4.5 Vacant
4.6 Vacant
4.7 Vacant
4.8 Vacant
4.9 Switching overvoltages
Subclause 4.9 of IEC 60947-1 applies.
4.10 Electrically separated contact elements
Subclause 4.10 of IEC 60947-5-1 applies.
5 Product information
5.1 Nature of information
The following information shall be given by the manufacturer:
Identification
a) The manufacturer's name or trade mark.
b) A type designation or serial number that makes it possible to get the relevant information
concerning the switching element (or the entire control switch) from the manufacturer.
c) “IEC 60947-5-8” if the manufacturer claims compliance with this standard.
d) Three-position enabling switches shall be indelibly and legibly marked by the symbol:
NOTE If it is not possible to affix the marking to the switch due to size constraints, then the symbol may be put in
the instructions for installation, operation and maintenance.
Basic rated values and utilization
e) Actuating forces and operational stroke.
f) Rated operational voltages (see 4.3.1.1 of IEC 60947-5-1).
g) Utilization category and rated operational currents at the rated operational voltages of the
switching element.
h) Rated insulation voltage (see 4.3.1.2 of IEC 60947-5-1).
i) Rated impulse withstand voltage U in accordance with 4.3.1.3 of IEC 60947-1.
imp
a) j) IP code (see 5.1 and Annex C of IEC 60947-1).
k) Pollution degree (see 6.1.3.2 of IEC 60947-5-1).
l) Type and maximum ratings of short-circuit protective device (see 8.3.4.3 of
IEC 60947-5-1).
– 16 – 60947-5-8 © CEI:2006
m) Courant de court-circuit conditionnel, s’il est inférieur à 1 000 A.
n) Indication des éléments de contact de même polarité.
o) Durabilité mécanique et/ou électrique.
5.2 Marquage
5.2.1 Généralités
Le marquage des données spécifiées aux points a), b), c) et d) de 5.1 est obligatoire sur la
plaque signalétique de l’interrupteur de commande de validation à trois positions, de manière
à pouvoir obtenir des informations complètes auprès du constructeur.
Le marquage doit être indélébile et facilement lisible, et ne doit pas être placé sur des vis et
sur des parties facilement démontables.
Lorsqu’il y a une place suffisante, les données des points e) à o) de 5.1 doivent figurer sur la
plaque signalétique, ou sur l’interrupteur de commande de validation à trois positions ou alors
dans les documents publiés par le constructeur.
5.2.2 Identification et marquage des bornes
Le paragraphe 7.1.7.4 de la CEI 60947-1 s’applique.
5.2.3 Repères de fonction
Pour éviter toute confusion avec les appareils d’arrêt d’urgence, l’organe de commande d’un
interrupteur de commande de validation ne doit pas être coloré en rouge (voir aussi la
CEI 60204-1).
5.3 Instructions d’installation, de fonctionnement et d’entretien
Le paragraphe 5.3 de la CEI 60947-1 s’applique.
5.4 Informations complémentaires
Le paragraphe 5.4 de la CEI 60947-5-1 s’applique.
6 Conditions normales de service, de montage et de transport
L’Article 6 de la CEI 60947-1 s’applique avec les compléments suivants.
6.1.3.2 Degré de pollution
Sauf spécification contraire du constructeur, un interrupteur de commande de validation à
trois positions est prévu pour être installé dans les conditions d'environnement du degré de
pollution 3. Toutefois, d'autres degrés de pollution peuvent s'appliquer en fonction du micro-
environnement.
6.3 Montage
Les moyens doivent être fournis pour permettre à l’interrupteur de commande de validation à
trois positions d’être installé de façon sûre dans sa position de montage prévue.
60947-5-8 © IEC:2006 – 17 –
m) Conditional short-circuit current if less than 1 000 A.
n) Indication of contact elements of same polarity.
o) Mechanical and/or electrical durability.
5.2 Marking
5.2.1 General
Marking of data specified in items a), b), c) and d) of 5.1 is mandatory on the nameplate of
the three-position enabling switch in order to permit the complete information to be obtained
from the manufacturer.
Marking shall be indelible and easily legible, and shall not be placed on screws and easily
removable parts.
Whenever space permits, data under items e) to o) of 5.1 shall be included on the nameplate,
or on the three-position enabling switch or otherwise in the manufacturer's published
literature.
5.2.2 Terminal identification and marking
Subclause 7.1.7.4 of IEC 60947-1 applies.
5.2.3 Functional markings
To avoid confusion with emergency stop devices, the actuator of an enabling switch shall not
be coloured RED (see also IEC 60204-1).
5.3 Instructions for installation, operation and maintenance
Subclause 5.3 of IEC 60947-1 applies.
5.4 Additional information
Subclause 5.4 of IEC 60947-5-1 applies.
6 Normal service, mounting and transport conditions
Clause 6 of IEC 60947-1 applies with the following additions.
6.1.3.2 Pollution degree
Unless otherwise stated by the manufacturer, a three-position enabling switch is intended for
installation under environmental conditions of pollution degree 3. However, other pollution
degrees may apply, depending upon the micro-environment.
6.3 Mounting
Means shall be provided to allow the three-position enabling switch to be securely installed in
its intended mounting position.
– 18 – 60947-5-8 © CEI:2006
7 Dispositions relatives à la construction et au fonctionnement
7.1 Dispositions constructives
Le paragraphe 7.1 de la CEI 60947-1 s’applique sauf 7.1.1, 7.1.2, 7.1.6, 7.1.8 et 7.1.12, avec
les compléments suivants.
7.1.1 Matériaux
Le paragraphe 7.1.1 de la CEI 60947-5-1 s’applique.
7.1.2 Parties transportant le courant et
...








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.