Amendment 2 - Single-capped fluorescent lamps - Performance specifications

Amendement 2 - Lampes à fluorescence à culot unique - Prescriptions de performances.

General Information

Status
Published
Publication Date
27-Apr-2000
Drafting Committee
Current Stage
PPUB - Publication issued
Start Date
15-May-2000
Completion Date
28-Apr-2000
Ref Project

Relations

Buy Standard

Standard
IEC 60901:1996/AMD2:2000 - Amendment 2 - Single-capped fluorescent lamps - Performance specifications
English and French language
115 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NORME
CEI
INTERNATIONALE
IEC
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2000-04
Amendement 2
Lampes à fluorescence à culot unique –
Prescriptions de performances
Amendment 2
Single-capped fluorescent lamps –
Performance specifications
Les feuilles de cet amendement sont à insérer dans la
Publication 60901 (1996)
The sheets contained in this amendment are to be
inserted in Publication 60901 (1996)
 CEI 2000 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
Commission Electrotechnique Internationale
CODE PRIX
XA
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

INSTRUCTIONS POUR L’INSERTION INSTRUCTIONS FOR THE INSERTION
DES NOUVELLES PAGES ET FEUILLES OF NEW PAGES AND SHEETS
DE CARACTÉRISTIQUES DANS IN PUBLICATION
LA PUBLICATION
__________ __________
1. Retirer la page de titre et insérer la nouvelle page de titre. 1. Remove title page and insert new title page.
2. Retirer les pages I-1 à A-1 et insérer les nouvelles 2. Remove pages I-2 to A-1 and insert new pages I-2
pages I-1 à A-1. to A-1.
3. Retirer les pages B-7 à E-1 et insérer les nouvelles 3. Remove pages B-8 to E-1 and insert new pages B-8
pages B-7 à E-1. to E-1.
4. Retirer les pages II-3 à II-7 et insérer les nouvelles 4. Remove pages II-4 to II-8 and insert new pages II-4
pages II-3 à II-7. to II-8.
SECTION 2 – FEUILLES DE CARACTÉRISTIQUES SECTION 2 – DATA SHEETS
5. Retirer les feuilles 5. Remove sheets.
0518-1 (pages 1 et 2) 0518-1 (pages 1 and 2)
0526-1 (pages 1 et 2) 0526-1 (pages 1 and 2)
1413-1 (page 2) 1413-1 (page 2)
1418-1 (page 2) 1418-1 (page 2)
1426-1 (page 2) 1426-1 (page 2)
2005-1 (pages 1 et 2) 2005-1 (pages 1 and 2)
2007-1 (pages 1 et 2) 2007-1 (pages 1 and 2)
2009-1 (pages 1 et 2) 2009-1 (pages 1 and 2)
2011-1 (pages 1 et 2) 2011-1 (pages 1 and 2)
2218-1 (page 1) 2218-1 (page 1)
2224-1 (page 1) 2224-1 (page 1)
2236-1 (page 1) 2236-1 (page 1)
2510-1 (pages 1 et 2) 2510-1 (pages 1 and 2)
2513-1 (pages 1 et 2) 2513-1 (pages 1 and 2)
2518-1 (pages 1 et 2) 2518-1 (pages 1 and 2)
2526-1 (pages 1 et 2) 2526-1 (pages 1 and 2)
3118-1 (page 1) 3118-1 (page 1)
3124-1 (page 1) 3124-1 (page 1)
3136-1 (page 1) 3136-1 (page 1)
6240-1 (page 1) 6240-1 (page 1)
6255-1 (page 1) 6255-1 (page 1)
7412-1 (pages 1 et 2) 7412-1 (pages 1 and 2)
7416-1 (pages 1 et 2) 7416-1 (pages 1 and 2)
7424-1 (pages 1 et 2) 7424-1 (pages 1 and 2)
7432-1 (pages 1 et 2) 7432-1 (pages 1 and 2)
7442-1 (pages 1 et 2) 7442-1 (pages 1 and 2)
6. Insérer les nouvelles feuilles 6. Insert new sheets
0518-2 (pages 1 et 2) 0518-2 (pages 1 and 2)
0526-2 (pages 1 et 2) 0526-2 (pages 1 and 2)
1413-2 (page 2) 1413-2 (page 2)
1418-2 (page 2) 1418-2 (page 2)
1426-2 (page 2) 1426-2 (page 2)
2005-2 (pages 1 et 2) 2005-2 (pages 1 and 2)
2007-2 (pages 1 et 2) 2007-2 (pages 1 and 2)
2009-2 (pages 1 et 2) 2009-2 (pages 1 and 2)
2011-2 (pages 1 et 2) 2011-2 (pages 1 and 2)
2218-2 (page 1) 2218-2 (page 1)
2224-2 (page 1) 2224-2 (page 1)
2236-2 (page 1) 2236-2 (page 1)
2510-2 (pages 1 et 2) 2510-2 (pages 1 and 2)
2513-2 (pages 1 et 2) 2513-2 (pages 1 and 2)
2518-2 (pages 1 et 2) 2518-2 (pages 1 and 2)
2526-2 (pages 1 et 2) 2526-2 (pages 1 and 2)
3118-2 (page 1) 3118-2 (page 1)
3124-2 (page 1) 3124-2 (page 1)
3136-2 (page 1) 3136-2 (page 1)
3413-1 (pages 1, 2 et 3) 3413-1 (pages 1, 2 and 3)
3418-1 (pages 1, 2 et 3) 3418-1 (pages 1, 2 and 3)
3426-1 (pages 1, 2 et 3) 3426-1 (pages 1, 2 and 3)
6240-2 (page 1) 6240-2 (page 1)
6255-2 (page 1) 6255-2 (page 1)
7432-2 (pages 1 et 2) 7432-2 (pages 1 and 2)
7442-2 (pages 1 et 2) 7442-2 (pages 1 and 2)
7. Insérer les nouvelles feuilles A020-1 et B410-1. 7. Insert new sheets A020-1 and B410-1.

AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34A: Lampes, du comité d’études 34
de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
34A/908/FDIS 34A/914/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l’approbation de cet amendement.
___________
FOREWORD
This amendment has been prepared by subcommittee 34A: Lamps, of technical committee 34:
Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34A/908/FDIS 34A/914/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
___________
NORME CEI
INTERNATIONALE
IEC
INTERNATIONAL
Deuxième édition
STANDARD
Second edition
Modifiée selon les amendements 1 (1997) et 2 (2000)
Amended in accordance with amendments 1 (1997) and 2 (2000)
Lampes à fluorescence à culot unique –
Prescriptions de performances
Single-capped fluorescent lamps –
Performance specifications
 IEC 2000 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni utilisée No part of this publication may be reproduced or utilized in
sous quelque forme que ce soit et par aucun procédé, électronique any form or by any means, electronic or mechanical, including
ou mécanique, y compris la photocopie et les microfilms, sans photocopying and microfilm, without permission in writing from
l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
Commission Electrotechnique Internationale
International Electrotechnical Commission

– 2 – 60901 amend. 1  CEI:1997
SOMMAIRE
Pages
AVANT-PROPOS . 4
SECTION 1: GÉNÉRALITÉS
Articles
1.1 Domaine d'application . I-1
1.2 Enoncé général . I-1
1.3 Références normatives. I-1
1.4 Définitions. I-3
1.5 Prescriptions applicables aux lampes. I-5
1.6 Renseignements pour la conception du ballast et du starter . I-9
1.7 Renseignements pour la conception du luminaire. I-9
Annexes
A Méthode d'essai des caractéristiques d'amorçage . A-1
B Méthode d'essai des caractéristiques électriques, photométriques et de cathodes . B-1
C Méthode d'essai du maintien du flux et de la durée . C-1
D Renseignements pour la conception du ballast et du starter . D-1
E Renseignements pour la conception du luminaire. E-1
SECTION 2: FEUILLES DE CARACTÉRISTIQUES
Articles
2.1 Principes généraux de numérotation des feuilles de caractéristiques . II-1
2.2 Feuilles de dessins schématiques pour la localisation des dimensions des lampes II-1
2.3 Feuilles de caractéristiques des lampes . II-3
2.4 Feuilles d'encombrement maximal des lampes . II-7

901  IEC:1996 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
________
SINGLE-CAPPED FLUORESCENT LAMPS –
PERFORMANCE SPECIFICATIONS
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international cooperation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters, prepared by technical committees on
which all the National Committees having a special interest therein are represented, express, as nearly as
possible, an international consensus of opinion on the subjects dealt with.
3) They have the form of recommendations for international use published in the form of standards, technical
reports or guides and they are accepted by the National Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
International Standard IEC 901 has been prepared by sub-committee 34A: Lamps, of IEC
technical committee 34: Lamps and related equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
34A/588/FDIS 34A/634/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Annexes A, B and C form an integral part of this standard.
Annexes D and E are for information only.
This second edition of IEC 901 cancels and replaces the first edition, published in 1987,
amendment 1 (1989) and amendment 2 (1992). The main changes relate to:
– the removal of safety related items;
– the abandonment of the division into three sections;
– the introduction of new terminology;
– a new numbering of the lamp data sheets;
– the introduction of new lamp data sheets.

– I-1 – 60901 amend. 2  CEI:2000
LAMPES À FLUORESCENCE À CULOT UNIQUE –
PRESCRIPTIONS DE PERFORMANCES
1 Section 1: Généralités
1.1 Domaine d’application
La présente Norme Internationale fournit les prescriptions de performances des lampes à
fluorescence à culot unique pour éclairage général.
Les prescriptions de la présente norme concernent uniquement les essais de type.
Les conditions de conformité, y compris les méthodes d’évaluation statistique, sont à l’étude.
La présente norme traite des types de lampes et des modes de fonctionnement avec ballast
externe suivants:
a) lampes à dispositif d’amorçage interne et à cathodes préchauffées, destinées à fonc-
tionner aux fréquences des réseaux à courant alternatif;
b) lampes à dispositif d’amorçage externe et à cathodes préchauffées, destinées
à fonctionner à l’aide d’un starter aux fréquences des réseaux à courant alternatif et à
fonctionner, en outre, en haute fréquence;
c) lampes à dispositif d’amorçage externe et à cathodes préchauffées, destinées à
fonctionner sans l’aide d’un starter aux fréquences des réseaux à courant alternatif et
à fonctionner, en outre, en haute fréquence;
d) lampes à dispositif d’amorçage externe et à cathodes préchauffées, destinées à
fonctionner en haute fréquence;
e) lampes à dispositif d’amorçage externe et à cathodes non préchauffées, destinées
à fonctionner en haute fréquence.
1.2 Déclaration générale
On peut s’attendre à ce que les lampes conformes à la présente norme s’amorcent et
fonctionnent de façon satisfaisante sous des tensions comprises entre 92 % et 106 % de la
tension d’alimentation assignée et à une température ambiante comprise entre 10 °C
et 50 °C, lorsqu’elles sont associées à un ballast conforme à la CEI 60921 ou à la CEI 60929,
le cas échéant, à un starter conforme à la CEI 60155 ou à la CEI 60927, et à un luminaire
conforme à la CEI 60598-1.
NOTE Pour certaines lampes, des informations complémentaires pour la conception du ballast sont fournies pour
assurer un amorçage correct à une température ambiante de –15 °C.
1.3 Références normatives
Les documents normatifs suivants contiennent des dispositions qui, par suite de la référence
qui y est faite, constituent des dispositions valables pour la présente Norme internationale.
Pour les références datées, les amendements ultérieurs ou les révisions de ces publications
ne s’appliquent pas. Toutefois les parties prenantes aux accords fondés sur la présente
Norme internationale sont invitées à rechercher la possibilité d’appliquer les éditions les plus
récentes des documents normatifs indiqués ci-après. Pour les références non datées, la
dernière édition du document normatif en référence s’applique. Les membres de la CEI et de
l’ISO possèdent le registre des Normes internationales en vigueur.

60901 Amend. 2  IEC:2000 – I-2 –
SINGLE-CAPPED FLUORESCENT LAMPS –
PERFORMANCE SPECIFICATIONS
1 Section 1: General
1.1 Scope
This International Standard specifies the performance requirements for single-capped
fluorescent lamps for general lighting service.
The requirements of this standard relate only to type testing. Conditions of compliance,
including methods of statistical assessment, are under consideration.
The following lamp types and modes of operation with external ballasts are included:
a) lamps operated with an internal means of starting, having preheated cathodes, for oper-
ation on a.c. mains frequencies;
b) lamps operated with an external means of starting, having preheated cathodes, for
operation on a.c. mains frequencies with the use of a starter, and additionally operating on
high frequency;
c) lamps operated with an external means of starting, having preheated cathodes, for oper-
ation on a.c. mains frequencies without the use of a starter (starterless), and additionally
operating on high frequency;
d) lamps operated with an external means of starting, having preheated cathodes, for oper-
ation on high frequency;
e) lamps operated with
...