IEC 60384-26:2018/COR1:2020
(Corrigendum)Corrigendum 1 - Fixed capacitors for use in electronic equipment - Part 26: Sectional specification - Fixed aluminium electrolytic capacitors with conductive polymer solid electrolyte
Corrigendum 1 - Fixed capacitors for use in electronic equipment - Part 26: Sectional specification - Fixed aluminium electrolytic capacitors with conductive polymer solid electrolyte
Corrigendum 1 - Condensateurs fixes utilisés dans les équipements électroniques - Partie 26: Spécification intermédiaire - Condensateurs fixes électrolytiques en aluminium à électrolyte solide en polymère conducteur
General Information
Relations
Buy Standard
Standards Content (Sample)
IEC 2020
INTERNATIONAL ELECTROTECHNICAL COMMISSION
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
IEC 60384-26 IEC 60384-26
Edition 2.0 2018-05 Edition 2.0 2018-05
FIXED CAPACITORS FOR USE IN ELECTRONIC CONDENSATEURS FIXES UTILISÉS
EQUIPMENT – DANS LES ÉQUIPEMENTS ÉLECTRONIQUES –
Part 26: Sectional specification – Partie 26: Spécification intermédiaire –
Fixed aluminium electrolytic Condensateurs fixes
capacitors with conductive polymer solid électrolytiques en aluminium à électrolyte solide
electrolyte en polymère conducteur
CO RRI G E NDUM 1
Corrections to the French version appear after the English text.
Les corrections à la version française sont données après le texte anglais.
In Table 3, Group 0, 4.3 Dimension (detail), in the column "Conditions of test and
measurements", replace the text "See 4.3.2" with "See 4.3.1".
Group 0 ND See Table 2
e
See 4.22.1
4.22 High surge current
4.3 Visual examination See 4.3.1 No visible damage
Legible marking and as
specified in the detail
specification
4.3 Dimension (detail) See 4.3.1 See detail specification
In Table 3, Group 2, 4.13.5 Final inspections, Leakage current, in the column "Performance
requirements", replace the text "≤ 5 times of the limit in 4.4.3.1" with "≤ 5 times the limit in
4.4.1.3".
Group 2 D See Table 2
4.13 Damp heat, steady
See 4.13.1
state
4.13.2 Initial inspec
...
Questions, Comments and Discussion