Amendment 29 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges

Subscribe to IEC 60061 Database to access the full and updated content of the series.

Amendement 29 - Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et de la sécurité - Partie 3: Calibres

Subscribe to IEC 60061 Database to access the full and updated content of the series.

General Information

Status
Published
Publication Date
30-Oct-2002
Technical Committee
Current Stage
PPUB - Publication issued
Start Date
15-Nov-2002
Completion Date
31-Oct-2002
Ref Project

Buy Standard

Standard
IEC 60061-3:1969/AMD29:2002 - Amendment 29 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
English and French language
45 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NORME CEI




INTERNATIONALE IEC






INTERNATIONAL 60061-3




STANDARD


AMENDEMENT 29


AMENDMENT 29




2002-10






Amendement 29


Culots de lampes et douilles ainsi que calibres

pour le contrôle de l'interchangeabilité

et de la sécurité –
Partie 3:
Calibres

Amendment 29
Lamp caps and holders together with
gauges for the control of interchangeability
and safety –
Part 3:
Gauges


Les feuilles de cet amendement sont à insérer dans la
CEI 60061-3 (1969)

The sheets contained in this amendment are to be inserted

in IEC 60061-3 (1969)
 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
S
International Electrotechnical Commission PRICE CODE
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue

---------------------- Page: 1 ----------------------
NORME CEI




INTERNATIONALE IEC






INTERNATIONAL 60061-3




Edition 3.29
STANDARD




2002-10





Modifiée selon les Compléments:

Amended in accordance with Supplements:

A(1970), B(1971), C(1971), D(1972), E(1972), F(1975),

G(1977), H(1980), J(1983), K(1987), L(1989), M(1992), N(1994),

P(1994), Q(1995), R(1996), S(1996), T(1996), U(1997),

et les amendements/amendments 20(1998) 21(1999), 22(1999),

23(2000), 24(2001), 25(2001), 26(2001), 27(2002), 28(2002) et/and 29 (2002)


Culots de lampes et douilles ainsi que calibres

pour le contrôle de l'interchangeabilité
et de la sécurité –
Partie 3:
Calibres

Lamp caps and holders together with
gauges for the control of interchangeability
and safety –
Part 3:
Gauges



 IEC 2002 Droits de reproduction réservés  Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photo-copie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
Commission Electrotechnique Internationale
International Electrotechnical Commission
Международная Электротехническая Комиссия

---------------------- Page: 2 ----------------------
60061-3 Amend.29 © CEI/IEC:2002


INSTRUCTIONS POUR L'INSERTION DES INSTRUCTIONS FOR THE INSERTION OF NEW

NOUVELLES PAGES ET FEUILLES DE NORMES PAGES AND STANDARD SHEETS IN IEC 60061-3
DANS LA CEI 60061-3








1. Retirer la page de titre existante, les pages 1, 2, 3, 1. Remove existing title page, existing pages 1, 2, 3,

4, 5, 6, 7, 8, 9, 10, 11 and 12 and existing contents
4, 5, 6, 7, 8 ,9, 10, 11 et 12 existantes et le
sommaire par désignation existant pour culots et by designation for caps and bases (pages 1/3, 2/3,
socles (pages 1/3, 2/3 et 3/3) et sommaire par 3/3) and contents by designation for holders (pages

désignation pour douilles (pages 1/5, 2/5, 3/5, 4/5 1/5, 2/5, 3/5, 4/5 and 5/5), and insert in their place

and 5/5), et insérer la nouvelle page de titre, les new title page, new pages 1, 2, 3, 4, 5, 6, 7, 8, 9,
10, 11 and 12 and new contents by designation for
nouvelles pages 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 et 12

et le nouveau sommaire par désignation pour culots caps and bases (pages 1/4, 2/4, 3/4 and 4/4) and

et socles (pages 1/4, 2/4, 3/4 et 4/4), et le nouveau new contents by designation for holders (pages 1/5,
sommaire par désignation pour douilles (pages 1/5, 2/5, 3/5, 4/5 and 5/5).
2/5, 3/5, 4/5 and 5/5).


2. Retirer les feuilles existantes 2. Remove existing sheets
7006-39-1 (Page 1/1) 7006-39-1 (Page 1/1)
7006-39A-3 (Page 1/1) 7006-39A-3 (Page 1/1)
7006-39B-2 (Page 1/1) 7006-39B-2 (Page 1/1)
7006-77A-2 (page 1/1) 7006-77A-2 (page 1/1)
7006-78-3 (pages 1/3, 2/3 et 3/3) 7006-78-3 (pages 1/3, 2/3 and 3/3)
7006-78A-4 (pages 1/3, 2/3 et 3/3) 7006-78A-4 (pages 1/3, 2/3 and 3/3)
7006-78B-4 (pages 1/3, 2/3 et 3/3) 7006-78B-4 (pages 1/3, 2/3 and 3/3)
7006-78C-4 (pages 1/3, 2/3 et 3/3) 7006-78C-4 (pages 1/3, 2/3 and 3/3)
7006-78F-5 (pages 1/3, 2/3 et 3/3) 7006-78F-5 (pages 1/3, 2/3 and 3/3)
7006-78G-4 (pages 1/3, 2/3 et 3/3) 7006-78G-4 (pages 1/3, 2/3 and 3/3)

et les remplacer par les feuilles and insert in their place sheets
7006-39-1 (Page 1/1) Corrigendum 7006-39-1 (Page 1/1) Correction
7006-39A-3 (Page 1/1) Corrigendum 7006-39A-3 (Page 1/1) Correction
7006-39B-2 (Page 1/1) Corrigendum 7006-39B-2 (Page 1/1) Correction
7006-77A-2 (page 1/1) Corrigendum 7006-77A-2 (page 1/1) Correction
7006-78-4 (pages 1/3, 2/3 et 3/3) 7006-78-4 (pages 1/3, 2/3 and 3/3)
7006-78A-5 (pages 1/3, 2/3 et 3/3) 7006-78A-5 (pages 1/3, 2/3 and 3/3)
7006-78B-5 (pages 1/3, 2/3 et 3/3) 7006-78B-5 (pages 1/3, 2/3 and 3/3)
7006-78C-5 (pages 1/3, 2/3 et 3/3) 7006-78C-5 (pages 1/3, 2/3 and 3/3)
7006-78F-6 (pages 1/3, 2/3 et 3/3) 7006-78F-6 (pages 1/3, 2/3 and 3/3)
7006-78G-5 (pages 1/3, 2/3 et 3/3) 7006-78G-5 (pages 1/3, 2/3 and 3/3)

---------------------- Page: 3 ----------------------
AVANT-PROPOS


Le présent amendement a été établi par le sous-comité 34B: Culots et douilles, du comité

d’études 34 de la CEI: Lampes et équipements associés.


Le texte de cet amendement est issu des documents suivants

FDIS Rapport de vote

34B/1026/FDIS 34B/1033/RVD



Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant

abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2003-02. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.

__________
FOREWORD
This amendment has been prepared by subcommittee 34B: Lamp caps and holders, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:

FDIS Report on voting
34B/1026/FDIS 34B/1033/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table. The committee has decided that the contents of the
base publication and its amendments will remain unchanged until 2003-02. At this date, the
publication will be

• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________

---------------------- Page: 4 ----------------------
60061-3 Amend. 29 © CEI/IEC:2002 – 1 –


SOMMAIRE CONTENTS



CALIBRES – SOMMAIRE PAR DÉSIGNATION GAUGES – CONTENTS BY DESIGNATION


Feuilles Sheet

Chanfreins sur les arêtes des calibres. 7006-1-2 Facets on gauge edges . 7006-1-2

Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished

terminées BA20 . 7006-2-3 lamps BA20 . 7006-2-3

Calibre d'acceptation pour culots B22d destinés à Acceptance gauge for B22d caps intended for

un enfilage automatique . 7006-3-1 automatic wire threading . 7006-3-1

Calibres «Entre» pour culots à deux broches G1.27, "Go" gauges for bi-pin caps G1.27, GX1.27,
GX1.27, GY1.3, G2.54, GX2.54, GY2.5, G3.17 GY1.3, G2.54, GX2.54, GY2.5, G3.17

& GY3.2 . 7006-4-1 & GY3.2. 7006-4-1

Calibres pour vérifier l'insertion des culots dans Gauges for testing the insertion of caps

les douilles B15d, B22d & BY22d. 7006-4A-2 in lampholders B15d, B22d & BY22d . 7006-4A-2

Calibres pour vérifier la tenue des culots B15d Gauges for testing the retention of B15d and
et B22d dans la douille . 7006-4B-1 B22d caps in the holder . 7006-4B-1
Calibre «Entre» pour culot préfocus PX26 . 7006-5-2 "Go" gauge for prefocus cap PX26 . 7006-5-2
Calibre «Entre» et «N'Entre Pas» pour les languettes "Go" and "Not Go" gauge for the tabs of prefocus
du culot préfocus PX26 . 7006-5A-1 cap PX26. 7006-5A-1
Calibre «N'Entre Pas» pour la dimension Mmin "Not Go" gauge for dimension Mmin of prefocus
du culot préfocus PX26 . 7006-5B-2 cap PX26. 7006-5B-2
Calibre «Entre» pour douille PX26. 7006-5C-1 "Go" gauge for lampholder PX26 . 7006-5C-1
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées Ell . 7006-6-1 lamps Ell . 7006-6-1
Calibre «A» pour la vérification de la réalité Plug gauge"A" for testing contact-
du contact dans les douilles Ell . 7006-6A-1 making in lampholders Ell. 7006-6A-1
Calibre «B» pour la vérification de la réalité Plug gauge"B" for testing contact-
du contact dans les douilles Ell . 7006-6B-1 making in lampholders Ell. 7006-6B-1
Calibre «Entre» pour culots EY10 . 7006-7-1 "Go" gauge for caps EY10 . 7006-7-1
Calibre «Entre» pour douilles EY10 . 7006-7A-1 "Go" gauge for lampholders EY10. 7006-7A-1
Calibres «Entre» pour culots sur lampes "Go" gauges for caps on finished
terminées BAX9s & BAY9s . 7006-9-1 lamps BAX9s & BAY9s. 7006-9-1
Calibres tampons pour douilles de lampes Plug gauges for lampholders
BAX9s & BAY9s . 7006-9A-1 BAX9s & BAY9s . 7006-9A-1
Calibres pour la vérification de la réalité du Gauges for testing contact-making
contact dans les douilles de lampes BAX9s in lampholders BAX9s
& BAY9s . 7006-9B-1 & BAY9s . 7006-9B-1
Calibres «N'Entre Pas» pour la vérification de la "Not Go" gauges for checking
non-interchangeabilité des culots dans les douilles non-interchangeability of caps in lampholders
BAX9s & BAY9s . 7006-9C-1
BAX9s & BAY9s . 7006-9C-1
Calibres «N'Entre Pas» pour culots sur lampes
"Not Go" gauges for caps on finished
terminées BA9, B15, B22 & BY22d. 7006-10-8
lamps BA9, B15, B22 & BY22d. 7006-10-8
Calibres «Entre» pour culots sur lampes terminées
"Go" gauges for caps on finished lamps
BA9, B15, BA15 & B22 . 7006-11-8
BA9, B15, BA15 & B22. 7006-11-8
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished
BAY15. 7006-11B-2
lamps BAY15 . 7006-11B-2
Calibre «Entre» pour culot sur lampes terminées
"Go" gauge for cap on finished lamps
BAZ15d . 7006-11C-1
BAZ15d . 7006-11C-1
Calibre pour la dimension B des culots sur lampes
Gauge for dimension B of caps on finished
terminées BAU15 & BAZ15d. 7006-11D-1
lamps BAU15 & BAZ15d . 7006-11D-1
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished lamps
BA15s-3 (100°/130°). 7006-11E-1
BA15s-3 (100°/130°). 7006-11E-1
Calibres tampon pour douilles BA21, B15 & B22 . 7006-12-8
Plug gauges for lampholders BA21, B15 & B22. 7006-12-8
Calibres «Entre» supplémentaires pour les
Supplementary "Go" gauges for
douilles B22d & BY22d . 7006-12A-2
lampholders B22d & BY22d . 7006-12A-2
Calibre «N'Entre Pas»/Maintien pour
"Not Go"/Retention gauge for lampholders
douilles B22. 7006-12B-2
B22. 7006-12B-2
Calibre «Entre» supplémentaire pour douilles B15d 7006-12C-2
Supplementary "Go" gauge for lampholders B15d. 7006-12C-2
Calibre «N'Entre Pas»/Maintien pour
"Not Go"/Retention gauge for lampholders
douilles B15. 7006-12D-2
B15. 7006-12D-2
Calibres pour douilles BA9, BA15, BAU15,
Gauges for lampholders BA9, BA15, BAU15,
BAY15 & BAZ15. 7006-12E-2
BAY15 & BAZ15. 7006-12E-2


IEC 60061-3
CEI 60061-3

---------------------- Page: 5 ----------------------
60061-3 Amend. 29 © CEI/IEC:2002 – 2 –


Feuilles Sheet

Calibres pour la vérification de la réalité du contact dans Gauges for testing contact-making in lampholders
les douilles BA9, BA15, BAU15, BAY15 & BAZ15 7006-12F-2 BA9, BA15, BAU15, BAY15 & BAZ15. 7006-12F-2

Gauges for slots in lampholders
Calibres pour les encoches des douilles

B15d, B22d, B22d-3 & BY22d. 7006-13-5 B15d, B22d, B22d-3 & BY22d . 7006-13-5

Calibre pour vérifier la tenue des culots Gauge for testing the retention of

BA15 et BAY15 dans la douille. 7006-14-1 BA15 and BAY15 caps in the holder. 7006-14-1

Calibres de vérification de l'insertion des culots Gauges for testing the correct insertion of caps
in lampholders BA15, BAY15 & BAZ15. 7006-14A-2
dans les douilles BA15, BAY15 & BAZ15 . 7006-14A-2

Calibre pour la dimension B des culots BA15 et Gauge for dimension B of caps BA15 and

BAY15d sur lampes terminées. 7006-14B-1 BAY15d on finished lamps . 7006-14B-1

Calibre «Entre» pour dimension «P max» des "Go" gauge for dimension "P max" of

culots sur lampes terminées BAY15 . 7006-14C-2 caps on finished lamps BAY15 . 7006-14C-2

Gauge for checking contact position
Calibre pour la vérification de la position du
contact et de la force de contact dans les douilles and contact force in bayonet lampholders

à baïonnette B22d-3 (90°/135°). 7006-15-7 B22d-3 (90°/135°) . 7006-15-7

Calibres pour la vérification de la position du Gauges for checking contact position
contact et de la force de contact dans les douilles and contact force in bayonet lampholders
B22d & BY22d . 7006-15A-2
à baïonnette B22d & BY22d . 7006-15A-2
Calibre pour la vérification de la position du Gauge for checking contact position
contact et de la force de contact dans les douilles and contact force in bayonet lampholders
à baïonnette B15d . 7006-15B-1 B15d. 7006-15B-1
Calibre pour la vérification de la position du Gauge for checking contact position
contact et de la force de contact dans les douilles and contact force in bayonet lampholders
à baïonnette BA21d-3(120°) . 7006-15C-1 BA21d-3(120°) . 7006-15C-1
Calibre «Entre» pour culots BA21-3(120°) sur "Go" gauge for caps BA21-3(120°) on
lampes terminées . 7006-17-4 finished lamps. 7006-17-4
Calibre «Entre» pour culot sur lampes terminées "Go" gauge for cap on finished lamps
BY22d. 7006-17A-1 BY22d. 7006-17A-1
Calibre tampon pour douilles BY22d. 7006-17B-1 Plug gauge for lampholders BY22d . 7006-17B-1
Calibre tampon pour douilles BA20. 7006-18-2 Plug gauge for lampholders BA20 . 7006-18-2
Calibre pour la vérification de la réalité du Gauge for testing contact-
contact dans les douilles BA20 . 7006-18A-1 making in lampholders BA20. 7006-18A-1
Calibre «Entre» pour culot B22d-3(90°/135°)/25x26 "Go" gauge for cap B22d-3(90°/135°)/25x26
sur lampes terminées . 7006-19-2 on finished lamps. 7006-19-2
Calibre «Entre» pour culot sur lampe terminée "Go" gauge for cap on finished lamp
BAU15s . 7006-19A-1 BAU15s . 7006-19A-1
Calibre pour douille à baïonnette B22d-3 Plug gauge for bayonet lampholder B22d-3
(90°/135°) . 7006-20-4 (90°/135°) . 7006-20-4
Calibre pour la vérification de la protection contre Gauge for testing protection against bulb-neck
la fêlure du col de l'ampoule et pour la vérification damage and for testing contact-making
de la réalité du contact dans les douilles E27. 7006-21-5 in lampholders E27. 7006-21-5
Calibre pour la vérification de la réalité du contact Gauge for testing contact-making
et de la protection contre les contacts accidentels and protection against accidental contact
pendant l'insertion des lampes dans les during insertion of lamps in
douilles E27 . 7006-22A-4 lampholders E27 . 7006-22A-4
Calibre pour la détection de contacts latéraux par Gauge for detecting side-contacts with
des arêtes coupantes dans les douilles E27 . 7006-22B-1 cutting-edges in lampholders E27 . 7006-22B-1
Calibre I pour la vérification de la résilience Gauge I for checking side-contact resiliency
in lampholders E27. 7006-22C-1
du contact latéral dans les douilles E27 . 7006-22C-1
Calibre II pour la vérification de la résilience Gauge II for checking side-contact resiliency

du contact latéral dans les douilles E27 . 7006-22D-1 in lampholders E27. 7006-22D-1
Calibre pour la vérification de la protection contre Gauge for testing protection against bulb-neck
la fêlure du col de l'ampoule et pour la vérification damage and for testing contact-making in
de la réalité du contact dans les douilles E40. 7006-23-3 lampholders E40 . 7006-23-3
Calibre pour douille pour la vérification de la Plug gauge for lampholders for testing
protection contre les contacts accidentels E40. 7006-24-3 protection against accidental contact E40 . 7006-24-3
Calibre pour vérifier la réalité du contact pour Gauge for finished lamps fitted with E39
lampes munies du culot E39. 7006-24A-1 caps for testing contact-making. 7006-24A-1
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées E39 . 7006-24B-1 lamps E39 . 7006-24B-1
Calibre «N'Entre Pas» pour culots sur lampes "Not Go" gauge for caps on finished
terminées E39 . 7006-24C-1 lamps E39 . 7006-24C-1
Calibre pour la vérification de la protection contre Gauge for testing protection against bulb-neck
damage and for testing contact-making
la fêlure du col de l'ampoule et pour la vérification
de la réalité du contact dans les douilles E39. 7006-24D-1 in lampholders E39. 7006-24D-1

IEC 60061-3
CEI 60061-3

---------------------- Page: 6 ----------------------
60061-3 Amend.29 © CEI/IEC:2002 – 3 –


Feuilles Sheet

Calibre «Entre» pour le taraudage des douilles E39. 7006-24E-1 "Go" gauge for screw thread of lampholders E39. 7006-24E-1
Calibre pour la vérification de la torsion maximale Gauge for testing maximum insertion
torque in lampholders with shell-grip
d'insertion dans des douilles avec dispositif

de blocage E39. 7006-24F-1 features E39 . 7006-24F-1

Calibre pour la vérification de la torsion minimale Gauge for testing minimum torque in

dans des douilles avec dispositif de blocage E39 . 7006-24G-1 lampholders with shell-grip features E39. 7006-24G-1

Calibres «Entre» pour les taraudages des "Go" gauges for screw threads of
lampholders E10, E14 & E40. 7006-25-7
douilles E10, E14 & E40. 7006-25-7

Calibre «Entre» pour douilles E27. 7006-25A-2 "Go" gauge for lampholders E27 . 7006-25A-2

Calibre «Entre» pour douilles E26. 7006-25B-2 "Go" gauge for lampholders E26 . 7006-25B-2

Calibre «Entre» pour douilles E12. 7006-25C-1 "Go" plug gauge for lampholders E12 . 7006-25C-1

Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished

lamps E5 . 7006-25D-1
terminées E5 . 7006-25D-1

Calibre «N'Entre Pas» pour culots sur lampes "Not Go" gauge for caps on finished

terminées E5 . 7006-25E-1 lamps E5 . 7006-25E-1
Calibre «Entre» pour vérifier les taraudages "Go" plug gauge for checking screw threads
des douilles E5. 7006-25F-1 of lampholders E5. 7006-25F-1
"Not Go"gauge for checking screw threads
Calibre «N'Entre Pas» pour vérifier les taraudages
des douilles E5. 7006-25G-1 of lampholders E5. 7006-25G-1
Calibre «Entre» pour douilles E17. 7006-25H-1 "Go" gauge for lampholders E17 . 7006-25H-1
Calibre pour la vérification de la réalité du contact Gauge for testing contact-making in lamp-
dans les douilles E26 . 7006-25J-1 holders E26 . 7006-25J-1
Calibres «N'Entre Pas» pour les taraudages des "Not Go" gauges for screw threads of lampholders
douilles E10, EP10, EY10, E14, E27, E39 & E40. 7006-26-4 E10, EP10, EY10, E14, E27, E39 & E40. 7006-26-4
Calibre «N'Entre Pas» pour douilles E26 & E26d . 7006-26A-2 "Not Go" gauge for lampholders E26 & E26d. 7006-26A-2
Calibre «N'Entre Pas» pour douilles E12. 7006-26B-1 "Not Go" plug gauge for lampholders E12 . 7006-26B-1
Calibre «N'Entre Pas» pour douilles E17. 7006-26C-1 "Not Go" gauge for lampholders E17 . 7006-26C-1
Calibre pour la vérification de la réalité du contact Gauge for testing contact-making of lamps fitted
pour lampes munies du culot E17 . 7006-26D-1 with caps E17. 7006-26D-1
Calibre pour la vérification de la réalité du contact Gauge for testing contact-making in
dans les douilles E17 . 7006-26E-1 lampholders E17 . 7006-26E-1
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées E40 . 7006-27-7 lamps E40 . 7006-27-7
Calibre «Entre» pour culots E10 . 7006-27A-2 "Go" gauge for caps E10 . 7006-27A-2
Calibre «Entre» pour culots E27 sur lampes terminées 7006-27B-1 "Go" gauge for E27 caps on finished lamps. 7006-27B-1
Calibre «Entre» pour dimension «S1» des culots "Go" gauge for dimension "S1" of E27
E27 sur lampes terminées. 7006-27C-1 caps on finished lamps. 7006-27C-1
Calibre «Entre» pour culots E26, E26/50x39, "Go" gauge for caps E26, E26/50x39, E26/51x39
E26/51x39 & E26d. 7006-27D-3 & E26d. 7006-27D-3
Calibre «Entre» pour culots E14 sur lampes "Go" gauge for E14 caps on finished
terminées. 7006-27F-1 lamps. 7006-27F-1
Calibre «Entre» pour dimension «S1» des culots "Go" gauge for dimension "S1" of
E14 sur lampes terminées. 7006-27G-1 E14 caps on finished lamps . 7006-27G-1
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées E12 . 7006-27H-1 lamps E12 . 7006-27H-1
Calibre «Entre» additionnel pour culots sur Additional "Go" gauge for caps on
lampes terminées E12. 7006-27J-1 finished lamps E12 . 7006-27J-1
Calibre «Entre» pour culots sur "Go" gauge for caps on finished

lampes terminées E17. 7006-27K-1 lamps E17 . 7006-27K-1
Calibre «N'Entre Pas» pour culots EP10. 7006-28-7 "Not Go" gauge for caps EP10. 7006-28-7
Calibre «N'Entre Pas» pour culots E27 "Not Go" gauge for E27 caps
sur lampes terminées . 7006-28A-1 on finished lamps. 7006-28A-1
Calibre «N'Entre Pas» pour culots E14 "Not Go" gauge for E14 caps
sur lampes terminées . 7006-28B-1 on finished lamps. 7006-28B-1
Calibre «N'Entre Pas» pour culots sur "Not Go" gauge for caps on
lampes terminées E12. 7006-28C-1 finished lamps E12 . 7006-28C-1
Calibre «N'Entre Pas» pour culots sur "Not Go" gauge for caps on
lampes terminées E40. 7006-28D-1 finished lamps E40 . 7006-28D-1
Calibre «N'Entre Pas» pour culots E10 & EY10 . 7006-28E-1 "Not Go" gauge for caps E10 & EY10. 7006-28E-1
Calibre «N'Entre Pas» pour culots sur "Not Go" gauge for caps on
lampes terminées E17. 7006-28F-1 finished lamps E17 .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.