IEC 60061-3:1969/AMD29:2002
(Amendment)Amendment 29 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
Amendment 29 - Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
Subscribe to IEC 60061 Database to access the full and updated content of the series.
Amendement 29 - Culots de lampes et douilles ainsi que calibres pour le contrôle de l'interchangeabilité et de la sécurité - Partie 3: Calibres
Subscribe to IEC 60061 Database to access the full and updated content of the series.
General Information
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
INTERNATIONAL 60061-3
STANDARD
AMENDEMENT 29
AMENDMENT 29
2002-10
Amendement 29
Culots de lampes et douilles ainsi que calibres
pour le contrôle de l'interchangeabilité
et de la sécurité –
Partie 3:
Calibres
Amendment 29
Lamp caps and holders together with
gauges for the control of interchangeability
and safety –
Part 3:
Gauges
Les feuilles de cet amendement sont à insérer dans la
CEI 60061-3 (1969)
The sheets contained in this amendment are to be inserted
in IEC 60061-3 (1969)
IEC 2002 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
S
International Electrotechnical Commission PRICE CODE
Международная Электротехническая Комиссия
Pour prix, voir catalogue en vigueur
For price, see current catalogue
NORME CEI
INTERNATIONALE IEC
INTERNATIONAL 60061-3
Edition 3.29
STANDARD
2002-10
Modifiée selon les Compléments:
Amended in accordance with Supplements:
A(1970), B(1971), C(1971), D(1972), E(1972), F(1975),
G(1977), H(1980), J(1983), K(1987), L(1989), M(1992), N(1994),
P(1994), Q(1995), R(1996), S(1996), T(1996), U(1997),
et les amendements/amendments 20(1998) 21(1999), 22(1999),
23(2000), 24(2001), 25(2001), 26(2001), 27(2002), 28(2002) et/and 29 (2002)
Culots de lampes et douilles ainsi que calibres
pour le contrôle de l'interchangeabilité
et de la sécurité –
Partie 3:
Calibres
Lamp caps and holders together with
gauges for the control of interchangeability
and safety –
Part 3:
Gauges
IEC 2002 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni No part of this publication may be reproduced or utilized in
utilisée sous quelque forme que ce soit et par aucun procédé, any form or by any means, electronic or mechanical,
électronique ou mécanique, y compris la photo-copie et les including photocopying and microfilm, without permission in
microfilms, sans l'accord écrit de l'éditeur. writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
Commission Electrotechnique Internationale
International Electrotechnical Commission
Международная Электротехническая Комиссия
60061-3 Amend.29 © CEI/IEC:2002
INSTRUCTIONS POUR L'INSERTION DES INSTRUCTIONS FOR THE INSERTION OF NEW
NOUVELLES PAGES ET FEUILLES DE NORMES PAGES AND STANDARD SHEETS IN IEC 60061-3
DANS LA CEI 60061-3
1. Retirer la page de titre existante, les pages 1, 2, 3, 1. Remove existing title page, existing pages 1, 2, 3,
4, 5, 6, 7, 8, 9, 10, 11 and 12 and existing contents
4, 5, 6, 7, 8 ,9, 10, 11 et 12 existantes et le
sommaire par désignation existant pour culots et by designation for caps and bases (pages 1/3, 2/3,
socles (pages 1/3, 2/3 et 3/3) et sommaire par 3/3) and contents by designation for holders (pages
désignation pour douilles (pages 1/5, 2/5, 3/5, 4/5 1/5, 2/5, 3/5, 4/5 and 5/5), and insert in their place
and 5/5), et insérer la nouvelle page de titre, les new title page, new pages 1, 2, 3, 4, 5, 6, 7, 8, 9,
10, 11 and 12 and new contents by designation for
nouvelles pages 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 et 12
et le nouveau sommaire par désignation pour culots caps and bases (pages 1/4, 2/4, 3/4 and 4/4) and
et socles (pages 1/4, 2/4, 3/4 et 4/4), et le nouveau new contents by designation for holders (pages 1/5,
sommaire par désignation pour douilles (pages 1/5, 2/5, 3/5, 4/5 and 5/5).
2/5, 3/5, 4/5 and 5/5).
2. Retirer les feuilles existantes 2. Remove existing sheets
7006-39-1 (Page 1/1) 7006-39-1 (Page 1/1)
7006-39A-3 (Page 1/1) 7006-39A-3 (Page 1/1)
7006-39B-2 (Page 1/1) 7006-39B-2 (Page 1/1)
7006-77A-2 (page 1/1) 7006-77A-2 (page 1/1)
7006-78-3 (pages 1/3, 2/3 et 3/3) 7006-78-3 (pages 1/3, 2/3 and 3/3)
7006-78A-4 (pages 1/3, 2/3 et 3/3) 7006-78A-4 (pages 1/3, 2/3 and 3/3)
7006-78B-4 (pages 1/3, 2/3 et 3/3) 7006-78B-4 (pages 1/3, 2/3 and 3/3)
7006-78C-4 (pages 1/3, 2/3 et 3/3) 7006-78C-4 (pages 1/3, 2/3 and 3/3)
7006-78F-5 (pages 1/3, 2/3 et 3/3) 7006-78F-5 (pages 1/3, 2/3 and 3/3)
7006-78G-4 (pages 1/3, 2/3 et 3/3) 7006-78G-4 (pages 1/3, 2/3 and 3/3)
et les remplacer par les feuilles and insert in their place sheets
7006-39-1 (Page 1/1) Corrigendum 7006-39-1 (Page 1/1) Correction
7006-39A-3 (Page 1/1) Corrigendum 7006-39A-3 (Page 1/1) Correction
7006-39B-2 (Page 1/1) Corrigendum 7006-39B-2 (Page 1/1) Correction
7006-77A-2 (page 1/1) Corrigendum 7006-77A-2 (page 1/1) Correction
7006-78-4 (pages 1/3, 2/3 et 3/3) 7006-78-4 (pages 1/3, 2/3 and 3/3)
7006-78A-5 (pages 1/3, 2/3 et 3/3) 7006-78A-5 (pages 1/3, 2/3 and 3/3)
7006-78B-5 (pages 1/3, 2/3 et 3/3) 7006-78B-5 (pages 1/3, 2/3 and 3/3)
7006-78C-5 (pages 1/3, 2/3 et 3/3) 7006-78C-5 (pages 1/3, 2/3 and 3/3)
7006-78F-6 (pages 1/3, 2/3 et 3/3) 7006-78F-6 (pages 1/3, 2/3 and 3/3)
7006-78G-5 (pages 1/3, 2/3 et 3/3) 7006-78G-5 (pages 1/3, 2/3 and 3/3)
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 34B: Culots et douilles, du comité
d’études 34 de la CEI: Lampes et équipements associés.
Le texte de cet amendement est issu des documents suivants
FDIS Rapport de vote
34B/1026/FDIS 34B/1033/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
Le comité a décidé que le contenu de la publication de base et de ses amendements ne sera
pas modifié avant 2003-02. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
__________
FOREWORD
This amendment has been prepared by subcommittee 34B: Lamp caps and holders, of IEC
technical committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34B/1026/FDIS 34B/1033/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table. The committee has decided that the contents of the
base publication and its amendments will remain unchanged until 2003-02. At this date, the
publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
_____________
60061-3 Amend. 29 © CEI/IEC:2002 – 1 –
SOMMAIRE CONTENTS
CALIBRES – SOMMAIRE PAR DÉSIGNATION GAUGES – CONTENTS BY DESIGNATION
Feuilles Sheet
Chanfreins sur les arêtes des calibres. 7006-1-2 Facets on gauge edges . 7006-1-2
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées BA20 . 7006-2-3 lamps BA20 . 7006-2-3
Calibre d'acceptation pour culots B22d destinés à Acceptance gauge for B22d caps intended for
un enfilage automatique . 7006-3-1 automatic wire threading . 7006-3-1
Calibres «Entre» pour culots à deux broches G1.27, "Go" gauges for bi-pin caps G1.27, GX1.27,
GX1.27, GY1.3, G2.54, GX2.54, GY2.5, G3.17 GY1.3, G2.54, GX2.54, GY2.5, G3.17
& GY3.2 . 7006-4-1 & GY3.2. 7006-4-1
Calibres pour vérifier l'insertion des culots dans Gauges for testing the insertion of caps
les douilles B15d, B22d & BY22d. 7006-4A-2 in lampholders B15d, B22d & BY22d . 7006-4A-2
Calibres pour vérifier la tenue des culots B15d Gauges for testing the retention of B15d and
et B22d dans la douille . 7006-4B-1 B22d caps in the holder . 7006-4B-1
Calibre «Entre» pour culot préfocus PX26 . 7006-5-2 "Go" gauge for prefocus cap PX26 . 7006-5-2
Calibre «Entre» et «N'Entre Pas» pour les languettes "Go" and "Not Go" gauge for the tabs of prefocus
du culot préfocus PX26 . 7006-5A-1 cap PX26. 7006-5A-1
Calibre «N'Entre Pas» pour la dimension Mmin "Not Go" gauge for dimension Mmin of prefocus
du culot préfocus PX26 . 7006-5B-2 cap PX26. 7006-5B-2
Calibre «Entre» pour douille PX26. 7006-5C-1 "Go" gauge for lampholder PX26 . 7006-5C-1
Calibre «Entre» pour culots sur lampes "Go" gauge for caps on finished
terminées Ell . 7006-6-1 lamps Ell . 7006-6-1
Calibre «A» pour la vérification de la réalité Plug gauge"A" for testing contact-
du contact dans les douilles Ell . 7006-6A-1 making in lampholders Ell. 7006-6A-1
Calibre «B» pour la vérification de la réalité Plug gauge"B" for testing contact-
du contact dans les douilles Ell . 7006-6B-1 making in lampholders Ell. 7006-6B-1
Calibre «Entre» pour culots EY10 . 7006-7-1 "Go" gauge for caps EY10 . 7006-7-1
Calibre «Entre» pour douilles EY10 . 7006-7A-1 "Go" gauge for lampholders EY10. 7006-7A-1
Calibres «Entre» pour culots sur lampes "Go" gauges for caps on finished
terminées BAX9s & BAY9s . 7006-9-1 lamps BAX9s & BAY9s. 7006-9-1
Calibres tampons pour douilles de lampes Plug gauges for lampholders
BAX9s & BAY9s . 7006-9A-1 BAX9s & BAY9s . 7006-9A-1
Calibres pour la vérification de la réalité du Gauges for testing contact-making
contact dans les douilles de lampes BAX9s in lampholders BAX9s
& BAY9s . 7006-9B-1 & BAY9s . 7006-9B-1
Calibres «N'Entre Pas» pour la vérification de la "Not Go" gauges for checking
non-interchangeabilité des culots dans les douilles non-interchangeability of caps in lampholders
BAX9s & BAY9s . 7006-9C-1
BAX9s & BAY9s . 7006-9C-1
Calibres «N'Entre Pas» pour culots sur lampes
"Not Go" gauges for caps on finished
terminées BA9, B15, B22 & BY22d. 7006-10-8
lamps BA9, B15, B22 & BY22d. 7006-10-8
Calibres «Entre» pour culots sur lampes terminées
"Go" gauges for caps on finished lamps
BA9, B15, BA15 & B22 . 7006-11-8
BA9, B15, BA15 & B22. 7006-11-8
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished
BAY15. 7006-11B-2
lamps BAY15 . 7006-11B-2
Calibre «Entre» pour culot sur lampes terminées
"Go" gauge for cap on finished lamps
BAZ15d . 7006-11C-1
BAZ15d . 7006-11C-1
Calibre pour la dimension B des culots sur lampes
Gauge for dimension B of caps on finished
terminées BAU15 & BAZ15d. 7006-11D-1
lamps BAU15 & BAZ15d . 7006-11D-1
Calibre «Entre» pour culots sur lampes terminées
"Go" gauge for caps on finished lamps
BA15s-3 (100°/130°). 7006-11E-1
BA15s-3 (100°/130°). 7006-11E-1
Calibres tampon pour douilles BA21, B15 & B22 . 7006-12-8
Plug gauges for lampholders BA21, B15 & B22. 7006-12-8
Calibres «Entre» supplémentaires pour les
Supplementary "Go" gauges for
douilles B22d & BY22d . 7006-12A-2
lampholders B22d & BY22d . 7006-12A-2
Calibre «N'Entre Pas»/Maintien pour
"Not Go"/Retention gauge for lampholders
douilles B22. 7006-12B-2
B22. 7006-12B-2
Calibre «Entre» supplémentaire pour douilles B15d 7006-12C-2
Supplementary "Go" gauge for lampholders B15d. 7006-12C-2
Calibre «N'Entre Pas»/Maintien pour
"Not Go"/Retention gauge for lampholders
douilles B15. 7006-12D-2
B15. 7006-12D-2
Calibres pour douilles BA9, BA15, BAU15,
Gauges for lampholders BA9, BA15, BAU15,
BAY15 & BAZ15. 7006-12E-2
BAY15 & BAZ15. 7006-12E-2
IEC 60061-3
CEI 60061-3
60061-3 Amend. 29 © CEI/IEC:2002 – 2 –
Feuilles Sheet
Calibres pour la vérification de la réalité du contact dans Gauges for testing contact-making in lampholders
les douilles BA9, BA15, BAU15, BAY15 & BAZ15 7006-12F-2 BA9, BA15, BAU15, BAY15 & BAZ15. 7006-12F-2
Gauges for slots in lampholders
Calibres pour les encoches des douilles
B15d, B22d, B22d-3 & BY22d. 7006-13-5 B15d, B22d, B22d-3 & BY22d . 7006-13-5
Calibre pour vérifier la tenue des culots Gauge for t
...
Questions, Comments and Discussion