ISO 2971:2013
(Main)Cigarettes and filter rods — Determination of nominal diameter — Method using a non-contact optical measuring apparatus
Cigarettes and filter rods — Determination of nominal diameter — Method using a non-contact optical measuring apparatus
ISO 2971:2013 specifies a non contact, optical method of gauging for determination of the mean, minimum and maximum diameters and the ovality (or roundness) of rod-shaped objects with a nominally circular or oval cross section that is convex curvilinear. The method is applicable, in particular, to cigarettes and filter rods.
Cigarettes et bâtonnets-filtres — Détermination du diamètre nominal — Méthode utilisant un instrument de mesure optique sans contact
L'ISO 2971:2013 spécifie une méthode optique de détermination, par calibrage sans contact, des diamètres moyen, minimal et maximal et de l'ovalisation (ou circularité) des objets cylindriques de section droite circulaire ou ovale qui est curviligne convexe. La méthode est applicable en particulier aux cigarettes et aux bâtonnets-filtres.
Cigarete in filtri - Določevanje nazivnega premera - Metoda uporabe nekontaktnih optičnih merilnih naprav
Ta mednarodni standard določa nekontaktno, optično merilno metodo za določevanje povprečnega, najmanjšega in največjega premera ter ovalnosti (ali okroglosti) predmetov v obliki valja z nominalno okroglim ali ovalnim prerezom, ki je konveksno ukrivljen. Ta metoda se uporablja zlasti za cigarete in filtre.
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2014
1DGRPHãþD
SIST ISO 2971:1998
&LJDUHWHLQILOWUL'RORþHYDQMHQD]LYQHJDSUHPHUD0HWRGDXSRUDEHQHNRQWDNWQLK
RSWLþQLKPHULOQLKQDSUDY
Cigarettes and filter rods - Determination of nominal diameter - Method using a non-
contact optical measuring apparatus
Cigarettes et bâtonnets-filtres - Détermination du diamètre nominal - Méthode utilisant un
instrument de mesure optique sans contact
Ta slovenski standard je istoveten z: ISO 2971:2013
ICS:
65.160 7REDNWREDþQLL]GHONLLQ Tobacco, tobacco products
RSUHPD and related equipment
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
INTERNATIONAL ISO
STANDARD 2971
Fourth edition
2013-04-01
Cigarettes and filter rods —
Determination of nominal diameter —
Method using a non-contact optical
measuring apparatus
Cigarettes et bâtonnets-filtres — Détermination du diamètre nominal —
Méthode utilisant un instrument de mesure optique sans contact
Reference number
©
ISO 2013
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
6 Sampling . 3
7 Procedure. 3
7.1 Preparation of test pieces . 3
7.2 Adjustment and calibration . 4
7.3 Measurement . 4
8 Expression of results . 4
9 Repeatability and reproducibility . 5
10 Test report . 5
Annex A (normative) Calibration standards . 7
Annex B (informative) Measurement principle and required number of scans .8
Annex C (informative) Information on possible source of measurement error
...................................................10
Annex D (informative) Non-contact measurement techniques .12
Annex E (informative) Alternative measurement techniques for the determination of nominal
diameter of cigarettes and filter rods .15
Annex F (informative) Protocol for ISO/TC 126/SC 1/WG 2 interlaboratory diameter
measurement uncertainty study .17
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International
Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies
casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 2971 was prepared by Technical Committee ISO/TC 126, Tobacco and tobacco products, Subcommittee
SC 1, Physical and dimensional tests.
This fourth edition cancels and replaces the third edition (ISO 2971:1998), which has been technically
revised.
iv © ISO 2013 – All rights reserved
INTERNATIONAL STANDARD ISO 2971:2013(E)
Cigarettes and filter rods — Determination of nominal
diameter — Method using a non-contact optical
measuring apparatus
1 Scope
This International Standard specifies a non contact, optical method of gauging for determination of
the mean, minimum and maximum diameters and the ovality (or roundness) of rod-shaped objects
with a nominally circular or oval cross section that is convex curvilinear. The method is applicable, in
particular, to cigarettes and filter rods.
NOTE 1 Non-contact measurement techniques are discussed in Annex D.
NOTE 2 Alternative contact or pneumatic methods may be used but should be considered as secondary methods
and do not come within the scope of the standard. These alternative measurement techniques are discussed in Annex E.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 3402, Tobacco and tobacco products — Atmosphere for conditioning and testing
ISO 5725-2:1994, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic
method for the determination of repeatability and reproducibility of a standard measurement method
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1
diameter
arithmetical mean value of n apparent diameters measured on a test piece following the method specified
in this International Standard, which represents the diameter of a circle with the same circumference as
the perimeter of the sample being measured, provided that the boundary of its cross section is convex
Note 1 to entry: The result of the measurement can be affected by n, the number of readings taken.
3.2
convex cross section
a cross section where the straight line between any two points from the section is also included
within the section
3.3
perimeter
length of the line that is the boundary of the cross section
Note 1 to entry: Errors will exist in the estimated value of the perimeter if the sample is not circular. The error
will increase as the ovality increases.
3.4
circumference
perimeter of a circular cross section
3.5
minimum diameter
minimum value obtained from the results of n individual readings performed on a test piece
3.6
maximum diameter
maximum value obtained from the results of n individual readings performed on a test piece
3.7
absolute ovality
expression of the out-of-roundness of a rod-like test piece, which is obtained from the arithmetic
difference between the maximum and minimum diameters obtained from n individual readings
3.8
relative ovality
ratio of the absolute ovality and the diameter, expressed as a percentage
3.9
relative roundness
100 minus relative ovality
Note 1 to entry: Caution should be exercised in interpreting maximum diameters, absolute ovality, relative ovality
and relative roundness as these can be affected by the quality of the gum line (raised laps) or other product
defects, generating erroneous individual readings.
4 Principle
The principle of measurement of the mean diameter of a shape having a convex cross section follows the
generalization of ‘Barbier’s Theorem’, which states that the mean diameter of a section is equal to the
arithmetic mean of the apparent (or projected) diameters of the section as it is rotated at equiangular
intervals in the field of view. It is required that the section is rotated by an integer multiple of 180°.
NOTE The principle is demonstrated in Annex B.1.
5 Apparatus
5.1 Sample conditioning enclosure, to be capable of maintaining the conditions given in ISO 3402.
5.2 Optical measuring apparatus, to consist of the following.
5.2.1 Optical measuring instrument
This must have an uncertainty of no more than 0,01 mm and be suitable for the determination of the
diameter of rod-like test pieces with a nearly circular cross section. A schematic diagram of such an
instrument is presented in Figure 1 and three different implementations are described in Annex D.
The scanning rate of the instrument shall be such that no eccentric motion of the test piece parallel to
the longitudinal axis, within the measurement area, shall affect the accuracy of the measurement of
mean diameter.
The ratio between the scanning rate of the apparatus and the rotational speed of the test piece shall be
constant and high enough to ensure that the measured diameter, as well as the minimum and maximum
values, shall be determined with sufficient accuracy, despite the possible ovality of the test piece.
The length of the scan path shall be sufficiently greater than the maximum diameter to be measured to
avoid errors due to test piece eccentricity. The test piece shall be scanned a minimum of 32 times during
a half-rotation (180°) or 64 times during a full (360°) rotation.
NOTE The rationale for the required number of scans is presented in Annex B.2.
2 © ISO 2013 – All rights reserved
5.2.2 Apparatus or fixture for rotating the test piece or scan path
This shall rotate the test piece within the measurement area or rotate the direction of view around the
test piece while maintaining the longitudinal axis of the test piece perpendicular to the measurement
area during a full 360° rotation.
Key
1 test piece
2 test piece longitudinal axis and axis of rotation
3 plane of the measurement
4 measurement centreline
5 measurement area
6 test piece cross section
7 projection plane
8 apparent diameter (orthogonal projection or image) of the test piece cross section
Figure 1 — Diagram of a generic non-contact optical gauging system
6 Sampling
Take a statistically representative sample of the population of test pieces to be characterized.
Samples shall be free of obvious visible defects which may affect the measurement.
7 Procedure
7.1 Preparation of test pieces
Condition the test pieces, prior to measurement, in a conditioning enclosure in accordance with ISO 3402.
Select at random, from the sample taken in accordance with Clause 6, the number of test pieces required
for the test.
The time required for the curing of filter rods and the duration of conditioning for both filter rods
and cigarettes are not specified in this International Standard and are to be determined by practical
experience. They shall be reported in the test report together with the results.
7.2 Adjustment and calibration
Working standards are routinely used to adjust c
...
INTERNATIONAL ISO
STANDARD 2971
Fourth edition
2013-04-01
Cigarettes and filter rods —
Determination of nominal diameter —
Method using a non-contact optical
measuring apparatus
Cigarettes et bâtonnets-filtres — Détermination du diamètre nominal —
Méthode utilisant un instrument de mesure optique sans contact
Reference number
©
ISO 2013
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
6 Sampling . 3
7 Procedure. 3
7.1 Preparation of test pieces . 3
7.2 Adjustment and calibration . 4
7.3 Measurement . 4
8 Expression of results . 4
9 Repeatability and reproducibility . 5
10 Test report . 5
Annex A (normative) Calibration standards . 7
Annex B (informative) Measurement principle and required number of scans .8
Annex C (informative) Information on possible source of measurement error
...................................................10
Annex D (informative) Non-contact measurement techniques .12
Annex E (informative) Alternative measurement techniques for the determination of nominal
diameter of cigarettes and filter rods .15
Annex F (informative) Protocol for ISO/TC 126/SC 1/WG 2 interlaboratory diameter
measurement uncertainty study .17
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International
Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies
casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 2971 was prepared by Technical Committee ISO/TC 126, Tobacco and tobacco products, Subcommittee
SC 1, Physical and dimensional tests.
This fourth edition cancels and replaces the third edition (ISO 2971:1998), which has been technically
revised.
iv © ISO 2013 – All rights reserved
INTERNATIONAL STANDARD ISO 2971:2013(E)
Cigarettes and filter rods — Determination of nominal
diameter — Method using a non-contact optical
measuring apparatus
1 Scope
This International Standard specifies a non contact, optical method of gauging for determination of
the mean, minimum and maximum diameters and the ovality (or roundness) of rod-shaped objects
with a nominally circular or oval cross section that is convex curvilinear. The method is applicable, in
particular, to cigarettes and filter rods.
NOTE 1 Non-contact measurement techniques are discussed in Annex D.
NOTE 2 Alternative contact or pneumatic methods may be used but should be considered as secondary methods
and do not come within the scope of the standard. These alternative measurement techniques are discussed in Annex E.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 3402, Tobacco and tobacco products — Atmosphere for conditioning and testing
ISO 5725-2:1994, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic
method for the determination of repeatability and reproducibility of a standard measurement method
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1
diameter
arithmetical mean value of n apparent diameters measured on a test piece following the method specified
in this International Standard, which represents the diameter of a circle with the same circumference as
the perimeter of the sample being measured, provided that the boundary of its cross section is convex
Note 1 to entry: The result of the measurement can be affected by n, the number of readings taken.
3.2
convex cross section
a cross section where the straight line between any two points from the section is also included
within the section
3.3
perimeter
length of the line that is the boundary of the cross section
Note 1 to entry: Errors will exist in the estimated value of the perimeter if the sample is not circular. The error
will increase as the ovality increases.
3.4
circumference
perimeter of a circular cross section
3.5
minimum diameter
minimum value obtained from the results of n individual readings performed on a test piece
3.6
maximum diameter
maximum value obtained from the results of n individual readings performed on a test piece
3.7
absolute ovality
expression of the out-of-roundness of a rod-like test piece, which is obtained from the arithmetic
difference between the maximum and minimum diameters obtained from n individual readings
3.8
relative ovality
ratio of the absolute ovality and the diameter, expressed as a percentage
3.9
relative roundness
100 minus relative ovality
Note 1 to entry: Caution should be exercised in interpreting maximum diameters, absolute ovality, relative ovality
and relative roundness as these can be affected by the quality of the gum line (raised laps) or other product
defects, generating erroneous individual readings.
4 Principle
The principle of measurement of the mean diameter of a shape having a convex cross section follows the
generalization of ‘Barbier’s Theorem’, which states that the mean diameter of a section is equal to the
arithmetic mean of the apparent (or projected) diameters of the section as it is rotated at equiangular
intervals in the field of view. It is required that the section is rotated by an integer multiple of 180°.
NOTE The principle is demonstrated in Annex B.1.
5 Apparatus
5.1 Sample conditioning enclosure, to be capable of maintaining the conditions given in ISO 3402.
5.2 Optical measuring apparatus, to consist of the following.
5.2.1 Optical measuring instrument
This must have an uncertainty of no more than 0,01 mm and be suitable for the determination of the
diameter of rod-like test pieces with a nearly circular cross section. A schematic diagram of such an
instrument is presented in Figure 1 and three different implementations are described in Annex D.
The scanning rate of the instrument shall be such that no eccentric motion of the test piece parallel to
the longitudinal axis, within the measurement area, shall affect the accuracy of the measurement of
mean diameter.
The ratio between the scanning rate of the apparatus and the rotational speed of the test piece shall be
constant and high enough to ensure that the measured diameter, as well as the minimum and maximum
values, shall be determined with sufficient accuracy, despite the possible ovality of the test piece.
The length of the scan path shall be sufficiently greater than the maximum diameter to be measured to
avoid errors due to test piece eccentricity. The test piece shall be scanned a minimum of 32 times during
a half-rotation (180°) or 64 times during a full (360°) rotation.
NOTE The rationale for the required number of scans is presented in Annex B.2.
2 © ISO 2013 – All rights reserved
5.2.2 Apparatus or fixture for rotating the test piece or scan path
This shall rotate the test piece within the measurement area or rotate the direction of view around the
test piece while maintaining the longitudinal axis of the test piece perpendicular to the measurement
area during a full 360° rotation.
Key
1 test piece
2 test piece longitudinal axis and axis of rotation
3 plane of the measurement
4 measurement centreline
5 measurement area
6 test piece cross section
7 projection plane
8 apparent diameter (orthogonal projection or image) of the test piece cross section
Figure 1 — Diagram of a generic non-contact optical gauging system
6 Sampling
Take a statistically representative sample of the population of test pieces to be characterized.
Samples shall be free of obvious visible defects which may affect the measurement.
7 Procedure
7.1 Preparation of test pieces
Condition the test pieces, prior to measurement, in a conditioning enclosure in accordance with ISO 3402.
Select at random, from the sample taken in accordance with Clause 6, the number of test pieces required
for the test.
The time required for the curing of filter rods and the duration of conditioning for both filter rods
and cigarettes are not specified in this International Standard and are to be determined by practical
experience. They shall be reported in the test report together with the results.
7.2 Adjustment and calibration
Working standards are routinely used to adjust calibrate or check the calibration of the measurement
system. Calibration shall be performed in accordance with the manufacturer’s instructions.
NOTE The essential properties of calibration standards are given in Annex A.
7.3 Measurement
In accordance with the manufacturer’s instructions, position the test piece within the measurement
area, as close as possible to the centre of the measurement area.
The test piece, or the measuring apparatus, shall be capable of being rotated around the rotation axis
such that any eccentric motion of the test piece, relative to the plane of the measurement, remains in
parallel with the plane of the measurement and perpendicular to the longitudinal axis of the test piece.
Adjust the instrument and/or feeding and rotational apparatus for the plane of the measurement to
measure the required section of the test piece.
Operate the apparatus in accordance with the manufacturer’s instructions and accurately record the
mean, minimum and maximum diameters.
At least 10 test pieces fro
...
INTERNATIONAL ISO
STANDARD 2971
Fourth edition
2013-04-01
Cigarettes and filter rods —
Determination of nominal diameter —
Method using a non-contact optical
measuring apparatus
Cigarettes et bâtonnets-filtres — Détermination du diamètre nominal —
Méthode utilisant un instrument de mesure optique sans contact
Reference number
©
ISO 2013
© ISO 2013
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2013 – All rights reserved
Contents Page
Foreword .iv
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Apparatus . 2
6 Sampling . 3
7 Procedure. 3
7.1 Preparation of test pieces . 3
7.2 Adjustment and calibration . 4
7.3 Measurement . 4
8 Expression of results . 4
9 Repeatability and reproducibility . 5
10 Test report . 5
Annex A (normative) Calibration standards . 7
Annex B (informative) Measurement principle and required number of scans .8
Annex C (informative) Information on possible source of measurement error
...................................................10
Annex D (informative) Non-contact measurement techniques .12
Annex E (informative) Alternative measurement techniques for the determination of nominal
diameter of cigarettes and filter rods .15
Annex F (informative) Protocol for ISO/TC 126/SC 1/WG 2 interlaboratory diameter
measurement uncertainty study .17
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International
Standards adopted by the technical committees are circulated to the member bodies for voting.
Publication as an International Standard requires approval by at least 75 % of the member bodies
casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 2971 was prepared by Technical Committee ISO/TC 126, Tobacco and tobacco products, Subcommittee
SC 1, Physical and dimensional tests.
This fourth edition cancels and replaces the third edition (ISO 2971:1998), which has been technically
revised.
iv © ISO 2013 – All rights reserved
INTERNATIONAL STANDARD ISO 2971:2013(E)
Cigarettes and filter rods — Determination of nominal
diameter — Method using a non-contact optical
measuring apparatus
1 Scope
This International Standard specifies a non contact, optical method of gauging for determination of
the mean, minimum and maximum diameters and the ovality (or roundness) of rod-shaped objects
with a nominally circular or oval cross section that is convex curvilinear. The method is applicable, in
particular, to cigarettes and filter rods.
NOTE 1 Non-contact measurement techniques are discussed in Annex D.
NOTE 2 Alternative contact or pneumatic methods may be used but should be considered as secondary methods
and do not come within the scope of the standard. These alternative measurement techniques are discussed in Annex E.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
ISO 3402, Tobacco and tobacco products — Atmosphere for conditioning and testing
ISO 5725-2:1994, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic
method for the determination of repeatability and reproducibility of a standard measurement method
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1
diameter
arithmetical mean value of n apparent diameters measured on a test piece following the method specified
in this International Standard, which represents the diameter of a circle with the same circumference as
the perimeter of the sample being measured, provided that the boundary of its cross section is convex
Note 1 to entry: The result of the measurement can be affected by n, the number of readings taken.
3.2
convex cross section
a cross section where the straight line between any two points from the section is also included
within the section
3.3
perimeter
length of the line that is the boundary of the cross section
Note 1 to entry: Errors will exist in the estimated value of the perimeter if the sample is not circular. The error
will increase as the ovality increases.
3.4
circumference
perimeter of a circular cross section
3.5
minimum diameter
minimum value obtained from the results of n individual readings performed on a test piece
3.6
maximum diameter
maximum value obtained from the results of n individual readings performed on a test piece
3.7
absolute ovality
expression of the out-of-roundness of a rod-like test piece, which is obtained from the arithmetic
difference between the maximum and minimum diameters obtained from n individual readings
3.8
relative ovality
ratio of the absolute ovality and the diameter, expressed as a percentage
3.9
relative roundness
100 minus relative ovality
Note 1 to entry: Caution should be exercised in interpreting maximum diameters, absolute ovality, relative ovality
and relative roundness as these can be affected by the quality of the gum line (raised laps) or other product
defects, generating erroneous individual readings.
4 Principle
The principle of measurement of the mean diameter of a shape having a convex cross section follows the
generalization of ‘Barbier’s Theorem’, which states that the mean diameter of a section is equal to the
arithmetic mean of the apparent (or projected) diameters of the section as it is rotated at equiangular
intervals in the field of view. It is required that the section is rotated by an integer multiple of 180°.
NOTE The principle is demonstrated in Annex B.1.
5 Apparatus
5.1 Sample conditioning enclosure, to be capable of maintaining the conditions given in ISO 3402.
5.2 Optical measuring apparatus, to consist of the following.
5.2.1 Optical measuring instrument
This must have an uncertainty of no more than 0,01 mm and be suitable for the determination of the
diameter of rod-like test pieces with a nearly circular cross section. A schematic diagram of such an
instrument is presented in Figure 1 and three different implementations are described in Annex D.
The scanning rate of the instrument shall be such that no eccentric motion of the test piece parallel to
the longitudinal axis, within the measurement area, shall affect the accuracy of the measurement of
mean diameter.
The ratio between the scanning rate of the apparatus and the rotational speed of the test piece shall be
constant and high enough to ensure that the measured diameter, as well as the minimum and maximum
values, shall be determined with sufficient accuracy, despite the possible ovality of the test piece.
The length of the scan path shall be sufficiently greater than the maximum diameter to be measured to
avoid errors due to test piece eccentricity. The test piece shall be scanned a minimum of 32 times during
a half-rotation (180°) or 64 times during a full (360°) rotation.
NOTE The rationale for the required number of scans is presented in Annex B.2.
2 © ISO 2013 – All rights reserved
5.2.2 Apparatus or fixture for rotating the test piece or scan path
This shall rotate the test piece within the measurement area or rotate the direction of view around the
test piece while maintaining the longitudinal axis of the test piece perpendicular to the measurement
area during a full 360° rotation.
Key
1 test piece
2 test piece longitudinal axis and axis of rotation
3 plane of the measurement
4 measurement centreline
5 measurement area
6 test piece cross section
7 projection plane
8 apparent diameter (orthogonal projection or image) of the test piece cross section
Figure 1 — Diagram of a generic non-contact optical gauging system
6 Sampling
Take a statistically representative sample of the population of test pieces to be characterized.
Samples shall be free of obvious visible defects which may affect the measurement.
7 Procedure
7.1 Preparation of test pieces
Condition the test pieces, prior to measurement, in a conditioning enclosure in accordance with ISO 3402.
Select at random, from the sample taken in accordance with Clause 6, the number of test pieces required
for the test.
The time required for the curing of filter rods and the duration of conditioning for both filter rods
and cigarettes are not specified in this International Standard and are to be determined by practical
experience. They shall be reported in the test report together with the results.
7.2 Adjustment and calibration
Working standards are routinely used to adjust calibrate or check the calibration of the measurement
system. Calibration shall be performed in accordance with the manufacturer’s instructions.
NOTE The essential properties of calibration standards are given in Annex A.
7.3 Measurement
In accordance with the manufacturer’s instructions, position the test piece within the measurement
area, as close as possible to the centre of the measurement area.
The test piece, or the measuring apparatus, shall be capable of being rotated around the rotation axis
such that any eccentric motion of the test piece, relative to the plane of the measurement, remains in
parallel with the plane of the measurement and perpendicular to the longitudinal axis of the test piece.
Adjust the instrument and/or feeding and rotational apparatus for the plane of the measurement to
measure the required section of the test piece.
Operate the apparatus in accordance with the manufacturer’s instructions and accurately record the
mean, minimum and maximum diameters.
At least 10 test pieces fro
...
NORME ISO
INTERNATIONALE 2971
Quatrième édition
2013-04-01
Cigarettes et bâtonnets-filtres —
Détermination du diamètre nominal —
Méthode utilisant un instrument de
mesure optique sans contact
Cigarettes and filter rods — Determination of nominal diameter —
Method using a non-contact optical measuring apparatus
Numéro de référence
©
ISO 2013
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2013
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2013 – Tous droits réservés
Sommaire Page
Avant-propos .iv
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe . 2
5 Appareillage . 2
6 Échantillonnage . 3
7 Mode opératoire. 4
7.1 Préparation des éprouvettes . 4
7.2 Réglage et étalonnage . 4
7.3 Mesurage . 4
8 Expression des résultats. 4
9 Répétabilité et reproductibilité . 5
10 Rapport d’essai . 5
Annexe A (normative) Piges étalons . 7
Annexe B (informative) Principe de mesure et nombre de balayages requis .8
Annexe C (informative) Informations sur les éventuelles sources d’erreur de mesure
..............................10
Annexe D (informative) Techniques de mesure sans contact .12
Annexe E (informative) Variantes de technique de mesure pour la détermination du diamètre
nominal des cigarettes et bâtonnets-filtres.15
Annexe F (informative) Protocole pour l’essai interlaboratoires de l’ISO/TC 126/SC 1/WG 2
portant sur l’incertitude de mesure du diamètre .17
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui concerne
la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives
ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de
Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour vote.
Leur publication comme Normes internationales requiert l’approbation de 75 % au moins des comités
membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de
ne pas avoir identifié de tels droits de propriété et averti de leur existence.
L’ISO 2971 a été élaborée par le comité technique ISO/TC 126, Tabac et produits du tabac, sous-comité
SC 1, Essais physiques et dimensionnels.
Cette quatrième édition annule et remplace la troisième édition (ISO 2971:1998), qui a fait l’objet d’une
révision technique.
iv © ISO 2013 – Tous droits réservés
NORME INTERNATIONALE ISO 2971:2013(F)
Cigarettes et bâtonnets-filtres — Détermination du
diamètre nominal — Méthode utilisant un instrument de
mesure optique sans contact
1 Domaine d’application
La présente Norme internationale spécifie une méthode optique de détermination, par calibrage
sans contact, des diamètres moyen, minimal et maximal et de l’ovalisation (ou circularité) des objets
cylindriques de section droite circulaire ou ovale qui est curviligne convexe. La méthode est applicable
en particulier aux cigarettes et aux bâtonnets-filtres.
NOTE 1 L’Annexe D décrit des techniques de mesure sans contact.
NOTE 2 D’autres méthodes avec contact ou pneumatiques peuvent être utilisées mais il convient de les
considérer comme des méthodes secondaires. Elles ne font pas partie du domaine d’application de la présente
Norme internationale. Ces techniques alternatives sont décrites dans l’Annexe E.
2 Références normatives
Les documents suivants, en totalité ou en partie, sont référencés de manière normative dans le présent
document et sont indispensables pour son application. Pour les références datées, seule l’édition citée
s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y
compris les éventuels amendements).
ISO 3402, Tabac et produits du tabac — Atmosphère de conditionnement et d’essai
ISO 5725-2:1994, Exactitude (justesse et fidélité) des résultats et méthodes de mesure — Partie 2: Méthode
de base pour la détermination de la répétabilité et de la reproductibilité d’une méthode de mesure normalisée
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
3.1
diamètre
moyenne arithmétique de n diamètres apparents mesurés sur une éprouvette en suivant la méthode
spécifiée dans la présente Norme internationale, dont la valeur représente le diamètre d’un cercle de
circonférence identique au périmètre de l’échantillon mesuré, à condition que la bordure de sa section
droite soit convexe
Note 1 à l’article: Le résultat de la mesure peut être affecté par n, le nombre de lectures effectuées.
3.2
section droite convexe
section droite dont le segment entre deux points quelconques de la section est également inclus
dans la section
3.3
périmètre
longueur qui constitue la bordure de la section droite
Note 1 à l’article: Des erreurs se produiront pour la valeur estimée du périmètre si l’échantillon n’est pas circulaire.
L’erreur augmentera en fonction de la hausse de l’ovalisation.
3.4
circonférence
périmètre d’une section droite circulaire
3.5
diamètre minimal
valeur minimale des résultats obtenus sur les n lectures individuelles, effectuées sur une éprouvette
3.6
diamètre maximal
valeur maximale des résultats obtenus sur les n lectures individuelles, effectuées sur une éprouvette
3.7
ovalisation absolue
expression de l’écart de circularité de forme d’une éprouvette cylindrique obtenue d’après la différence
arithmétique entre les diamètres maximal et minimal obtenue sur les n lectures individuelles
3.8
ovalisation relative
quotient de l’ovalisation absolue et du diamètre, exprimé en pourcentage
3.9
circularité relative
100 moins l’ovalisation relative
Note 1 à l’article: Il convient d’interpréter avec précaution les valeurs de diamètre maximal, d’ovalisation absolue,
d’ovalisation relative et de circularité relative, car elles peuvent être affectées par la qualité de la couture
(surépaisseur de chevauchement) ou d’autres défauts de produits qui donnent des lectures individuelles erronées.
4 Principe
Le principe de mesure du diamètre moyen d’une forme ayant une section droite convexe suit la
généralisation du ‘Théorème de Barbier’, qui énonce que le diamètre moyen d’une section est égal
à la moyenne arithmétique des diamètres apparents (ou projetés) de la section en cas de rotation à
intervalles équiangulaires dans le champ de vision. Il est nécessaire que la section soit mise en rotation
selon un multiple entier de 180°.
NOTE Le principe est démontré en B.1.
5 Appareillage
5.1 Enceinte de conditionnement de l’échantillon, capable de maintenir les conditions données
dans l’ISO 3402.
5.2 Appareil de mesurage optique, constitué des éléments suivants:
5.2.1 Instrument de mesurage optique.
Cet instrument doit avoir une incertitude ne dépassant pas 0,01 mm et être approprié pour déterminer
le diamètre d’éprouvettes cylindriques de section droite approximativement circulaire. Un schéma
d’un instrument de ce type est donné à la Figure 1 et trois différentes installations sont décrites dans
l’Annexe D.
La vitesse de balayage de l’instrument doit être telle qu’à l’intérieur de la zone de mesure, aucun
mouvement excentrique de l’éprouvette parallèlement à l’axe longitudinal n’affecte l’exactitude de
mesure du diamètre moyen.
2 © ISO 2013 – Tous droits réservés
Le rapport entre la vitesse de balayage de l’instrument et la vitesse de rotation de l’éprouvette doit
être constant et suffisamment grand pour permettre de déterminer avec une exactitude suffisante, non
seulement le diamètre mesuré, mais aussi les valeurs minimale et maximale de diamètres en dépit de la
possible ovalisation de l’éprouvette.
La longueur de la trajectoire de balayage doit être suffisamment supérieure au diamètre maximal à
mesurer pour éviter les erreurs dues à l’excentricité de l’éprouvette. L’éprouvette doit être balayée au
moins 32 fois pendant une demi-rotation (180°) ou 64 fois pendant une rotation complète (360°).
NOTE La justification du nombre de balayages requis est indiquée en B.2.
5.2.2 Appareil ou montage permettant de faire tourner l’éprouvette ou la trajectoire de balayage.
Cet appareil doit faire tourner l’éprouvette dans la zone de mesure ou faire tourner la direction de
visualisation autour de l’éprouvette tout en maintenant l’axe longitudinal de l’éprouvette perpendiculaire
à la zone de mesure pendant une rotation complète de 360°.
Légende
1 éprouvette
2 axe longitudinal de l’éprouvette et axe de rotation
3 plan de mesure
4 axe de mesure
5 zone de mesure
6 section droite de l’éprouvette
7 plan de projection
8 diamètre apparent (projection ou image orthogonale) de la section droite de l’éprouvette
Figure 1 — Schéma d’un système générique de calibrage optique sans contact
6 Échantillonnage
Prélever un échantillon représentatif sur le plan statistique de la population d’éprouvettes à caractériser.
Les échantillons doivent être exempts de défauts visibles évidents pouvant affecter le mesurage.
7 Mode opératoire
7.1 Préparation des éprouvettes
Conditionner les éprouvettes avant le mesurage dans une enceinte de conditionnement conformément
à l’ISO 3402.
Sur l’échantillon sélectionné conformément à l’Article 6, prélever au hasard le nombre d’éprouvettes
requis pour l’essai.
Le temps de séchage des bâtonnets-filtres et le temps de conditionnement des cigarettes et des bâtonnets-
filtres ne sont pas spécifiés dans la présente Norme internationale et sont déterminés par l’expérience
pratique acquise. Ils doivent être consignés dans le rapport d’essai avec les résultats.
7.2 Réglage et étalonnage
Des piges de travail sont communément utilisées pour le réglage, l’étalonnage ou la vérification de
l’étalonnage du système de mesurage. L’étalonnage doit être effectué conformément aux instructions
du fabricant.
NOTE Les propriétés essentielles des piges étalons sont données à l’Annexe A.
7.3 Mesurage
Conformément aux instructions du fabricant, placer l’éprouvette à l’intérieur de la z
...
NORME ISO
INTERNATIONALE 2971
Quatrième édition
2013-04-01
Cigarettes et bâtonnets-filtres —
Détermination du diamètre nominal —
Méthode utilisant un instrument de
mesure optique sans contact
Cigarettes and filter rods — Determination of nominal diameter —
Method using a non-contact optical measuring apparatus
Numéro de référence
©
ISO 2013
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2013
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2013 – Tous droits réservés
Sommaire Page
Avant-propos .iv
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe . 2
5 Appareillage . 2
6 Échantillonnage . 3
7 Mode opératoire. 4
7.1 Préparation des éprouvettes . 4
7.2 Réglage et étalonnage . 4
7.3 Mesurage . 4
8 Expression des résultats. 4
9 Répétabilité et reproductibilité . 5
10 Rapport d’essai . 5
Annexe A (normative) Piges étalons . 7
Annexe B (informative) Principe de mesure et nombre de balayages requis .8
Annexe C (informative) Informations sur les éventuelles sources d’erreur de mesure
..............................10
Annexe D (informative) Techniques de mesure sans contact .12
Annexe E (informative) Variantes de technique de mesure pour la détermination du diamètre
nominal des cigarettes et bâtonnets-filtres.15
Annexe F (informative) Protocole pour l’essai interlaboratoires de l’ISO/TC 126/SC 1/WG 2
portant sur l’incertitude de mesure du diamètre .17
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (CEI) en ce qui concerne
la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives
ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de
Normes internationales adoptés par les comités techniques sont soumis aux comités membres pour vote.
Leur publication comme Normes internationales requiert l’approbation de 75 % au moins des comités
membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de
ne pas avoir identifié de tels droits de propriété et averti de leur existence.
L’ISO 2971 a été élaborée par le comité technique ISO/TC 126, Tabac et produits du tabac, sous-comité
SC 1, Essais physiques et dimensionnels.
Cette quatrième édition annule et remplace la troisième édition (ISO 2971:1998), qui a fait l’objet d’une
révision technique.
iv © ISO 2013 – Tous droits réservés
NORME INTERNATIONALE ISO 2971:2013(F)
Cigarettes et bâtonnets-filtres — Détermination du
diamètre nominal — Méthode utilisant un instrument de
mesure optique sans contact
1 Domaine d’application
La présente Norme internationale spécifie une méthode optique de détermination, par calibrage
sans contact, des diamètres moyen, minimal et maximal et de l’ovalisation (ou circularité) des objets
cylindriques de section droite circulaire ou ovale qui est curviligne convexe. La méthode est applicable
en particulier aux cigarettes et aux bâtonnets-filtres.
NOTE 1 L’Annexe D décrit des techniques de mesure sans contact.
NOTE 2 D’autres méthodes avec contact ou pneumatiques peuvent être utilisées mais il convient de les
considérer comme des méthodes secondaires. Elles ne font pas partie du domaine d’application de la présente
Norme internationale. Ces techniques alternatives sont décrites dans l’Annexe E.
2 Références normatives
Les documents suivants, en totalité ou en partie, sont référencés de manière normative dans le présent
document et sont indispensables pour son application. Pour les références datées, seule l’édition citée
s’applique. Pour les références non datées, la dernière édition du document de référence s’applique (y
compris les éventuels amendements).
ISO 3402, Tabac et produits du tabac — Atmosphère de conditionnement et d’essai
ISO 5725-2:1994, Exactitude (justesse et fidélité) des résultats et méthodes de mesure — Partie 2: Méthode
de base pour la détermination de la répétabilité et de la reproductibilité d’une méthode de mesure normalisée
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions suivants s’appliquent.
3.1
diamètre
moyenne arithmétique de n diamètres apparents mesurés sur une éprouvette en suivant la méthode
spécifiée dans la présente Norme internationale, dont la valeur représente le diamètre d’un cercle de
circonférence identique au périmètre de l’échantillon mesuré, à condition que la bordure de sa section
droite soit convexe
Note 1 à l’article: Le résultat de la mesure peut être affecté par n, le nombre de lectures effectuées.
3.2
section droite convexe
section droite dont le segment entre deux points quelconques de la section est également inclus
dans la section
3.3
périmètre
longueur qui constitue la bordure de la section droite
Note 1 à l’article: Des erreurs se produiront pour la valeur estimée du périmètre si l’échantillon n’est pas circulaire.
L’erreur augmentera en fonction de la hausse de l’ovalisation.
3.4
circonférence
périmètre d’une section droite circulaire
3.5
diamètre minimal
valeur minimale des résultats obtenus sur les n lectures individuelles, effectuées sur une éprouvette
3.6
diamètre maximal
valeur maximale des résultats obtenus sur les n lectures individuelles, effectuées sur une éprouvette
3.7
ovalisation absolue
expression de l’écart de circularité de forme d’une éprouvette cylindrique obtenue d’après la différence
arithmétique entre les diamètres maximal et minimal obtenue sur les n lectures individuelles
3.8
ovalisation relative
quotient de l’ovalisation absolue et du diamètre, exprimé en pourcentage
3.9
circularité relative
100 moins l’ovalisation relative
Note 1 à l’article: Il convient d’interpréter avec précaution les valeurs de diamètre maximal, d’ovalisation absolue,
d’ovalisation relative et de circularité relative, car elles peuvent être affectées par la qualité de la couture
(surépaisseur de chevauchement) ou d’autres défauts de produits qui donnent des lectures individuelles erronées.
4 Principe
Le principe de mesure du diamètre moyen d’une forme ayant une section droite convexe suit la
généralisation du ‘Théorème de Barbier’, qui énonce que le diamètre moyen d’une section est égal
à la moyenne arithmétique des diamètres apparents (ou projetés) de la section en cas de rotation à
intervalles équiangulaires dans le champ de vision. Il est nécessaire que la section soit mise en rotation
selon un multiple entier de 180°.
NOTE Le principe est démontré en B.1.
5 Appareillage
5.1 Enceinte de conditionnement de l’échantillon, capable de maintenir les conditions données
dans l’ISO 3402.
5.2 Appareil de mesurage optique, constitué des éléments suivants:
5.2.1 Instrument de mesurage optique.
Cet instrument doit avoir une incertitude ne dépassant pas 0,01 mm et être approprié pour déterminer
le diamètre d’éprouvettes cylindriques de section droite approximativement circulaire. Un schéma
d’un instrument de ce type est donné à la Figure 1 et trois différentes installations sont décrites dans
l’Annexe D.
La vitesse de balayage de l’instrument doit être telle qu’à l’intérieur de la zone de mesure, aucun
mouvement excentrique de l’éprouvette parallèlement à l’axe longitudinal n’affecte l’exactitude de
mesure du diamètre moyen.
2 © ISO 2013 – Tous droits réservés
Le rapport entre la vitesse de balayage de l’instrument et la vitesse de rotation de l’éprouvette doit
être constant et suffisamment grand pour permettre de déterminer avec une exactitude suffisante, non
seulement le diamètre mesuré, mais aussi les valeurs minimale et maximale de diamètres en dépit de la
possible ovalisation de l’éprouvette.
La longueur de la trajectoire de balayage doit être suffisamment supérieure au diamètre maximal à
mesurer pour éviter les erreurs dues à l’excentricité de l’éprouvette. L’éprouvette doit être balayée au
moins 32 fois pendant une demi-rotation (180°) ou 64 fois pendant une rotation complète (360°).
NOTE La justification du nombre de balayages requis est indiquée en B.2.
5.2.2 Appareil ou montage permettant de faire tourner l’éprouvette ou la trajectoire de balayage.
Cet appareil doit faire tourner l’éprouvette dans la zone de mesure ou faire tourner la direction de
visualisation autour de l’éprouvette tout en maintenant l’axe longitudinal de l’éprouvette perpendiculaire
à la zone de mesure pendant une rotation complète de 360°.
Légende
1 éprouvette
2 axe longitudinal de l’éprouvette et axe de rotation
3 plan de mesure
4 axe de mesure
5 zone de mesure
6 section droite de l’éprouvette
7 plan de projection
8 diamètre apparent (projection ou image orthogonale) de la section droite de l’éprouvette
Figure 1 — Schéma d’un système générique de calibrage optique sans contact
6 Échantillonnage
Prélever un échantillon représentatif sur le plan statistique de la population d’éprouvettes à caractériser.
Les échantillons doivent être exempts de défauts visibles évidents pouvant affecter le mesurage.
7 Mode opératoire
7.1 Préparation des éprouvettes
Conditionner les éprouvettes avant le mesurage dans une enceinte de conditionnement conformément
à l’ISO 3402.
Sur l’échantillon sélectionné conformément à l’Article 6, prélever au hasard le nombre d’éprouvettes
requis pour l’essai.
Le temps de séchage des bâtonnets-filtres et le temps de conditionnement des cigarettes et des bâtonnets-
filtres ne sont pas spécifiés dans la présente Norme internationale et sont déterminés par l’expérience
pratique acquise. Ils doivent être consignés dans le rapport d’essai avec les résultats.
7.2 Réglage et étalonnage
Des piges de travail sont communément utilisées pour le réglage, l’étalonnage ou la vérification de
l’étalonnage du système de mesurage. L’étalonnage doit être effectué conformément aux instructions
du fabricant.
NOTE Les propriétés essentielles des piges étalons sont données à l’Annexe A.
7.3 Mesurage
Conformément aux instructions du fabricant, placer l’éprouvette à l’intérieur de la z
...
Questions, Comments and Discussion