Tobacco and tobacco products — Cigarettes and filters — Determination of nominal diameter

Tabac et produits du tabac — Cigarettes et filtres — Détermination du diamètre nominal

General Information

Status
Withdrawn
Publication Date
31-May-1976
Withdrawal Date
31-May-1976
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Aug-1987
Ref Project

Relations

Buy Standard

Standard
ISO 2971:1976 - Tobacco and tobacco products -- Cigarettes and filters -- Determination of nominal diameter
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2971:1976 - Tobacco and tobacco products — Cigarettes and filters — Determination of nominal diameter Released:6/1/1976
French language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD 2 971
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .MEXflYHAPOnHAfl OPrAHM3AUHfl iI0 CTAHnAPTH3AUMM .ORGANISATION INTERNATIONALE DE NORMALISATION
f
i
Tobacco and tobacco products - Cigarettes and filters -
j
t
Deter mi nation of nom inal diameter
I
1
Tabac et produits du tabac - Cigarettes et filtres - Détermination du diamètre nominal
I
First edition - 1976-06-01
i
f
-
w
-
Ref. No. IS0 2971 -1976 (E)
UDC 663.974
W
w
Descriptors : cigarettes, cigarette filters, tests, measurement, dimensions, diameter.
7
r-
w
O
E
Price based on 6 pages

---------------------- Page: 1 ----------------------
1 FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
to the Member Bodies for approval before their acceptance as International
Standards by the IS0 Council.
International Standard IS0 2971 was drawn up by Technical Committee
ISO/TC 126, Tobacco and tobacco products, and circulated to the Member Bodies
in October 1972.
it has been approved by the Member Bodies of the following countries :
South Africa, Rep. of
Australia I ran
Ireland Sweden
Belgium
Italy Switzerland
Egypt, Arab Rep. of
Mexico Thailand
France
Netherlands Turkey
Germany
New Zealand United Kingdom
Greece
Poland U S.S. R.
Hungary
India Romania
No Member Body expressed disapproval of the document.
Q International Organization for Standardization, 1976
Printed in Switzerland

---------------------- Page: 2 ----------------------
INTERNATIONAL STANDARD IS0 2971-1976 (E)
Tobacco and tobacco products - Cigarettes and filters -
Determination of nominal diameter
an accuracy of 1: 0,005 mm giving in the same measuring
O INTRODUCTION
head the same pressure reading (water height h) as the
The determination of the diameter of cigarettes and filters
cigarette or filter submitted to the measurement.
is difficult to achieve with sufficient accuracy by usual
NOTE - By convention, it is accepted that the results obtained
metrology using a sliding caliper or a micrometer gauge,
define the nominal diameter of cigarettes or filters which may
particularly because of :
possibly not be perfectly circular.
- possible distortion during measurement,
4.2 nominal diameter of a measuring head (D,) : The
- a slight ovality in practice of the cigarettes and
diameter in millimetres of the metal measuring rod ground
filters.
to an accuracy of 1: 0,005 mm with which the reading is
situated in the centre of the measuring range, this position
Using the method specified in this International Standard,
corresponding to maximum sensitivity.
there is a difference of about 0.02 mm between the results
obtained with a metal rod and those obtained with a filter
rod, because of the roughness of the paper.
5 PRINCIPLE
Introduction of the test piece into a measuring head having
1 SCOPE
a slightly larger circular cross-section through which
This International Standard specifies a method for
compressed air is applied to the test piece, and
determining the nominal diameter of cigarettes and filters
determination of the loss of pressure, which is proportional
by the pneumatic measuring head process. to the diameter of the test piece.
After calibration, the water column may be directly
graduated "in diameters" : To each height h of the water
2 FIELD OF APPLICATION
column corresponds a value D of the diameter.
The method is generally applicable to cylindrically shaped
cigarettes and filters.
6 APPARATUS
NOTE - Errors may occur in the case of cigarettes or filters
wrapped with papers of very high air permeability. These errors may
be overcome by plugging the extremities of the test piece (capsule,
6.1 Conditioning chamber, regulated in accordance with
paraffin wax, etc.).
the requirements of IS0 3402.
6.2 Pneumatic micromeasurer or micrometer giving one
3 REFERENCE
reading'), or other similar apparatus.
IS0 3402, Tobacco and tobacco products - Atmospheres
for conditioning and testing.
6.3 Device supplying compressed air, equipped with a
pressure stabilizer.
4 DEFINITIONS
6.4 Main jet2).
4.1 nominal diameter of a cigarette or filter : The
6.5 Outlet connection, with a ,diameter of about 12 mm.
diameter in millimetres of a metal measuring rod ground to
-
1) See annex B.
See clause 8.4 of annex B.
2)
1

---------------------- Page: 3 ----------------------
IS0 2971 -1976 (E)
6.6 Measuring headl) Therefore the graduations on a scale should only be used
within the approximate range of :
- inside diameter of the internal rings nominal
dimension + 0,30 mm;
(Dn - 0,30 mm) to (D, + 0.20 mm)
The useful range of nominal diameters of measuring heads,
- inside diameter of the external rings: nominal
D,, varies from 7 to 10,5 mm, but a certain overlapping of
dimension + 0,25 mm.
the scales of measurement of the different measuring heads
NOTE - The external rings are used not directly for measuring, but
is provided, with the result that it is always possible to
as a centering device and as a protection for the internal rings; there
operate other than at the limit of the scale on at least one
is no risk of inadvertently inserting a test piece with too great a
measuring head.
diameter.
7.2.2 Calibra tion
6.7 Set of cylindrical metal measuring rods, ground to an
For each measuring head (6.6). calibrate the apparatus
accuracy of 5 0,005 mm, graduated in diameter steps of
equipped with a given main jet (6.41, using a set of metal
0.05 mm.
measuring rods (6.7).
Transfer to the graduated scale corresponding to each
measuring head the value of the diameter D of the metal
7 PROCEDURE
measuring rod corresponding to the water height h
obtained.
If necessary, "smooth out" the calibration curve (see
7.1 Conditioning of the test pieces
annex A) in order to reduce the slight experimental
Introduce the test pieces into the conditioning chamber
deviations noted.
(6.1) and keep them there until equilibrium is attained (see
NOTE - The calibration concerns only the measuring head (6.6)
IS0 3402). For newly manufactured cigarettes, condition-
and the main jet (6.4).
ing is not necessary.
The main jets (6.4) are calibrated. They shall comply with
the standards in force. However, two
...

~~
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .MEXAYHAPOAHAfl OPrAHMJAUMfl IT0 CTAHLIAPTMSAUMM -0RGANISATlOP INTERNATIONALE DE NORMALISATION
Tabac Tabac et et produits produits du du tabac tabac - - Cigarettes Cigarettes et et filtres filtres - -
Détermination Détermination du du diamètre diamètre nominal nominal
Tobacco Tobacco and and tobacco tobacco products products - - Cigarettes Cigarettes and and filters filters - - Determination Determination of of nominal nominal diameter diameter
Première Première édition édition - - 1976-06-01 1976-06-01
CDU 663.974 Réf. no : IS0 2971-1976 (FI
Desaipteum : cigarette, filtre à cigarette, essai, mesurage, dimension, diamètre.
Prix base sur 6 pages

---------------------- Page: 1 ----------------------
AVANT-PROPOS
L'ISO (Organisation Internationale de Normalisation) est une fédération mondiale
d'organismes nationaux de normalisation (Comités Membres ISO). L'élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
et non
correspondant. Les organisations internationales, gouvernementales
gouvernementales, en liaison avec I'ISO, participent également aux travaux.
les Comités Techniques sont
Les Projets de Normes internationales adoptés par
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I'ISO.
La Norme Internationale IS0 2971 a été établie par le Comité Technique
ISO/TC 126, Tabac et produits du tabac, et soumise aux Comités Membres en
octobre 1972.
Elle a été approuvée par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d' Inde Roumanie
Allemagne Iran Royaume-Uni
Australie Irlande Suède
Belgique Italie Suisse
Egypte, Rép. arabe d' Mexique Tha ïI a nde
France Nouvel le-Zélande Turquie
Grèce Pays-Bas U.R.S.S.
Hongrie Pologne
Aucun Comité Membre n'a désapprouvé le document.
O Organisation Internationale de Normalisation, 1976 O
Imprimé en Suisse

---------------------- Page: 2 ----------------------
IS0 2971 -1976 (F)
NORME INTERNATIONALE
Tabac et produits du tabac - Cigarettes et filtres -
Détermination du diamètre nominal
f 0,005 mm, donnant, dans une même tête de mesurage,
O INTRODUCTION
la même indication de pression (hauteur d'eau h), que la
La détermination du diamètre des cigarettes et des filtres
cigarette ou le filtre soumis à la mesure.
est difficilement accessible avec une precision suffisante par
NOTE - Par convention, il est admis que les résultats obtenus
la métrologie habituelle, à l'aide du pied à coulisse ou du
définissent le diamètre nominal de cigarettes ou de filtres qui,
palmer, notamment à cause de
éventuellement, peuvent ne pas être parfaitement circulaires.
- la déformation possible au mesurage,
4.2 diamètre nominal d'une tête de mesurage (û,) :
- I'ovalisation pratique légère,
Diamètre, en millimètres, de la pige métallique rectifiée à
k 0,005 mm pour lequel la lecture se situe au milieu de
des cigarettes et des filtres.
l'échelle des mesures, position qui correspond à la sensi-
En utilisant la méthode spécifiée dans la présente Norme
bilité maximale.
Internationale, il y aura une différence d'environ 0.02 mm
entre les résultats obtenus avec un bâtonnet métallique et
ceux obtenus avec un bâtonnet filtre, due à la rugosité du
papier. 5 PRINCIPE
introduction de l'éprouvette dans une tête de mesurage
1 OBJET de section circulaire légèrement supérieure par laquelle de
l'air comprimé est appliqué sur l'éprouvette, et
La présente Norme Internationale spécifie une méthode de
détermination de la perte de charge qui est proportionnelle
détermination du diamètre nominal des cigarettes et des
au diamètre de l'éprouvette.
filtres, par le procédé pneumatique à tête de mesurage.
La colonne d'eau, après étalonnage, peut être directement
graduée «en diamètres)) : À chaque hauteur h de la colonne
2 DOMAINE D'APPLICATION
d'eau correspond une valeur D du diamètre.
La méthode est généralement applicable aux cigarettes et
aux filtres de forme cylindrique.
6 APPAREILLAGE
NOTE - Des erreurs peuvent se produire dans le cas de cigarettes ou
de filtres enveloppés dans du papier a perméabilité a l'air très élevée.
On peut éviter ces erreurs en fermant les extrémités de l'échantillon
6.1 Enceinte de conditionnement, réglée selon les
(capsuie, paraffine, etc.)
spécifications de I'ISO 3402.
6.2 Micromesureur ou micromètre pneumatique à une
3 RÉFÉRENCE
lecture'), ou autre appareillage approprié.
IS0 3402, Tabac et produits du tabac - Atmosphères de
conditionnement et d'essai.
6.3 Dispositif d'alimentation en air comprimé, muni d'un
stabilisateur de pression.
4 DÉFINITIONS
6.4 Gicleur de tête.2)
4.1 diamètre nominal d'une cigarette ou d'un filtre :
Diamètre, en millimètres, d'une pige métallique rectifiée à 6.5 Raccord de sortie. d'un diamètre d'environ 12 mm.
1) Voir annexe B.
2) Voir chapitre B.4 de l'annexe B.
1

---------------------- Page: 3 ----------------------
IS0 2971 -1976 (FI
II convient donc en pratique de n'utiliser l'échelle que sur
6.6 Tête de mesuragel)
une plage s'étendant d'environ :
- diamètre intérieur des bagues internes : cote
nominale 4- 0,30 mm;
(D, - 0,30 mm) à (D, + 0,20 mm)
- diamètre intérieur des bagues externes : cote La gamme utile des diamètres nominaux des têtes de
mesurage, D,, varie de 7 à 10,5 mm; mais un certain
nominale + 0,25 mm.
recouvrement des plages de mesurage des différentes
NOTE - Les bagues externes n'interviennent pas directement dans
têtes de mesurage est prévu, de sorte qu'il est toujours
le mesurage : elles servent de dispositif de centrage et de protection
possible d'opérer autrement qu'en limite de plage sur au
des bagues internes; il n'y a pas de risque d'engager, par mégarde,
moins une tête de mesurage.
une éprouvette de diamètre trop élevé.
7.2.2 Étalonnage
6.7 Jeu de piges métalliques cylindriques, rectifiées à
+, 0,005 mm, de diamètres échelonnés de 0,05 mm en
Pour chaque tête de mesurage (6.6), étalonner l'appareil
0.05 mm.
équipé d'un gicleur de tête (6.4) donné, à l'aide du jeu de
piges métalliques (6.7).
7 MODE OPÉRATOIRE
Porter sur l'échelle graduée, correspondant à chaque tête
de mesurage la valeur de diamètre D de la pige métallique
correspondant à la hauteur d'eau obtenue, h.
7.1 Conditionnement des éprouvettes
Au besoin, ((lisser)) la courbe d'étalonnage pour réduire les
Introduire les éprouvettes dans l'enceinte de
légers écarts expérimentaux constatés.
conditionnement (6.1) et les y maintenir jusqu'à ce que
l'équilibre soit obtenu (voir IS0 3402). Pour les cigarettes
NOTE - L'étalonnage concerne exclusivement la tête de mesurage
fraîchement fabriquées, le conditionnement n'est pas
(6.6) et le gicleur de tête (6.4).
nécessaire.
Les gicleurs de tête (6.4) sont calibrés et doivent répondre
aux normes en vi
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.