Determination of the ultimate aerobic biodegradability of plastic materials under controlled composting conditions — Method by analysis of evolved carbon dioxide — Part 1: General method

ISO 14855-1:2012 specifies a method for the determination of the ultimate aerobic biodegradability of plastics, based on organic compounds, under controlled composting conditions by measurement of the amount of carbon dioxide evolved and the degree of disintegration of the plastic at the end of the test. This method is designed to simulate typical aerobic composting conditions for the organic fraction of solid mixed municipal waste. The test material is exposed to an inoculum which is derived from compost. The composting takes place in an environment wherein temperature, aeration and humidity are closely monitored and controlled. The test method is designed to yield the percentage conversion of the carbon in the test material to evolved carbon dioxide as well as the rate of conversion. Also specified is a variant of the method, using a mineral bed (vermiculite) inoculated with thermophilic microorganisms obtained from compost with a specific activation phase, instead of mature compost. This variant is designed to yield the percentage of carbon in the test substance converted to carbon dioxide and the rate of conversion.

Évaluation de la biodégradabilité aérobie ultime des matériaux plastiques dans des conditions contrôlées de compostage — Méthode par analyse du dioxyde de carbone libéré — Partie 1: Méthode générale

General Information

Status
Published
Publication Date
25-Nov-2012
Current Stage
9093 - International Standard confirmed
Start Date
11-Jul-2017
Completion Date
30-Jun-2022
Ref Project

RELATIONS

Buy Standard

Standard
ISO 14855-1:2012 - Determination of the ultimate aerobic biodegradability of plastic materials under controlled composting conditions -- Method by analysis of evolved carbon dioxide
English language
20 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 14855-1:2012 - Évaluation de la biodégradabilité aérobie ultime des matériaux plastiques dans des conditions contrôlées de compostage -- Méthode par analyse du dioxyde de carbone libéré
French language
22 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

INTERNATIONAL ISO
STANDARD 14855-1
Second edition
2012-12-01
Determination of the ultimate aerobic
biodegradability of plastic materials
under controlled composting
conditions — Method by analysis of
evolved carbon dioxide —
Part 1:
General method
Évaluation de la biodégradabilité aérobie ultime des matériaux
plastiques dans des conditions contrôlées de compostage — Méthode
par analyse du dioxyde de carbone libéré —
Partie 1: Méthode générale
Reference number
ISO 14855-1:2012(E)
ISO 2012
---------------------- Page: 1 ----------------------
ISO 14855-1:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012

All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,

electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s

member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2012 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 14855-1:2012(E)
Contents Page

Foreword ............................................................................................................................................................................iv

Introduction ........................................................................................................................................................................ v

1 Scope ...................................................................................................................................................................... 1

2 Normative references ......................................................................................................................................... 1

3 Terms and definitions ......................................................................................................................................... 1

4 Principle ................................................................................................................................................................. 2

5 Test environment ................................................................................................................................................. 3

6 Reagents ................................................................................................................................................................ 3

6.1 TLC (thin-layer chromatography) grade cellulose ..................................................................................... 3

6.2 Vermiculite ............................................................................................................................................................. 3

7 Apparatus .............................................................................................................................................................. 4

8 Procedure .............................................................................................................................................................. 5

8.1 Preparation of the inoculum ............................................................................................................................. 5

8.2 Preparation of test material and reference material .................................................................................. 5

8.3 Start-up of the test .............................................................................................................................................. 6

8.4 Incubation period ................................................................................................................................................ 6

8.5 Termination of the test ....................................................................................................................................... 7

8.6 Use of vermiculite ............................................................................................................................................... 7

8.7 Recovery procedure and carbon balance when using vermiculite ....................................................... 8

9 Calculation and expression of results ........................................................................................................... 9

9.1 Calculation of the theoretical amount of carbon dioxide ......................................................................... 9

9.2 Calculation of the percentage biodegradation ............................................................................................ 9

9.3 Calculation of loss in mass .............................................................................................................................. 9

9.4 Expression of results ......................................................................................................................................... 9

10 Validity of results ...............................................................................................................................................10

11 Test report ...........................................................................................................................................................10

Annex A (informative) Principle of test system ........................................................................................................ 11

Annex B (informative) Examples of graphical representation of carbon dioxide evolution and

biodegradation curves .....................................................................................................................................12

Annex C (informative) Example of mass loss determination................................................................................14

Annex D (informative) Round-robin testing ...............................................................................................................16

Annex E (informative) Examples of forms .................................................................................................................17

Bibliography .....................................................................................................................................................................20

© ISO 2012 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 14855-1:2012(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies

(ISO member bodies). The work of preparing International Standards is normally carried out through ISO

technical committees. Each member body interested in a subject for which a technical committee has been

established has the right to be represented on that committee. International organizations, governmental and

non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International

Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.

International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.

The main task of technical committees is to prepare International Standards. Draft International Standards

adopted by the technical committees are circulated to the member bodies for voting. Publication as an

International Standard requires approval by at least 75 % of the member bodies casting a vote.

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent

rights. ISO shall not be held responsible for identifying any or all such patent rights.

ISO 14855-1 was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-

chemical properties.

This second edition of ISO 14855-1 cancels and replaces the first edition (ISO 14855-1:2005), of which it

constitutes a minor revision intended principally to clarify the wording of the fourth paragraph in Subclause 8.1.

In addition, the footnote to 6.2 concerning a possible supplier of “concrete” type vermiculite has been deleted

as it appeared to be no longer valid.

This second edition also cancels and replaces the Technical Corrigendum ISO 14855-1:2005/Cor.1:2009.

ISO 14855 consists of the following parts, under the general title Determination of the ultimate aerobic

biodegradability of plastic materials under controlled composting conditions — Method by analysis of evolved

carbon dioxide:
— Part 1: General method

— Part 2: Gravimetric measurement of carbon dioxide evolved in a laboratory-scale test

iv © ISO 2012 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 14855-1:2012(E)
Introduction

The main method specified in this part of ISO 14855 uses a solid-phase respirometric test system based on

mature compost used as a solid bed, a source of nutrients, and an inoculum rich in thermophilic microorganisms.

Mature compost is a very heterogeneous and complex material. Therefore, it can be difficult to quantify

the residual polymeric material left in the bed at the end of the test, to detect possible low-molecular-mass

molecules released into the solid bed by the polymeric material during degradation, and to assess the biomass.

As a result, it can be difficult to perform a complete carbon balance. Another difficulty which is sometimes

encountered with mature compost is a “priming effect”: the organic matter present in large amounts in the

mature compost can undergo polymer-induced degradation, known as the “priming effect”, which affects the

measurement of the biodegradability.

To overcome these difficulties and to improve the reliability of the method, the mature compost can be replaced

by a solid mineral medium which is used as the composting bed, thus facilitating analyses. This variant can

be used to measure the biodegradation in terms of CO evolution, to quantify and analyse the biomass and

the residues of polymeric material left in the solid bed at the end of the test, and to perform a complete carbon

balance. Furthermore, the method is not significantly affected by the priming effect and can, therefore, be used

to assess materials known to cause this problem with mature compost. The mineral bed can also be subjected

to an ecotoxicological analysis to verify the absence of any ecotoxic activity in the bed after biodegradation.

© ISO 2012 – All rights reserved v
---------------------- Page: 5 ----------------------
INTERNATIONAL STANDARD ISO 14855-1:2012(E)
Determination of the ultimate aerobic biodegradability of plastic
materials under controlled composting conditions — Method by
analysis of evolved carbon dioxide —
Part 1:
General method

WARNING — Sewage, activated sludge, soil and compost may contain potentially pathogenic

organisms. Therefore appropriate precautions should be taken when handling them. Toxic test

compounds and those whose properties are unknown should be handled with care.
1 Scope

This part of ISO 14855 specifies a method for the determination of the ultimate aerobic biodegradability of

plastics, based on organic compounds, under controlled composting conditions by measurement of the amount

of carbon dioxide evolved and the degree of disintegration of the plastic at the end of the test. This method is

designed to simulate typical aerobic composting conditions for the organic fraction of solid mixed municipal

waste. The test material is exposed to an inoculum which is derived from compost. The composting takes place

in an environment wherein temperature, aeration and humidity are closely monitored and controlled. The test

method is designed to yield the percentage conversion of the carbon in the test material to evolved carbon

dioxide as well as the rate of conversion.

Subclauses 8.6 and 8.7 specify a variant of the method, using a mineral bed (vermiculite) inoculated with

thermophilic microorganisms obtained from compost with a specific activation phase, instead of mature

compost. This variant is designed to yield the percentage of carbon in the test substance converted to carbon

dioxide and the rate of conversion.

The conditions described in this part of ISO 14855 may not always correspond to the optimum conditions for

the maximum degree of biodegradation to occur.
2 Normative references

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced document

(including any amendments) applies.

ISO 5663, Water quality — Determination of Kjeldahl nitrogen — Method after mineralization with selenium

ISO 8245, Water quality — Guidelines for the determination of total organic carbon (TOC) and dissolved

organic carbon (DOC)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
ultimate aerobic biodegradation

breakdown of an organic compound by microorganisms in the presence of oxygen into carbon dioxide, water

and mineral salts of any other elements present (mineralization) plus new biomass

© ISO 2012 – All rights reserved 1
---------------------- Page: 6 ----------------------
ISO 14855-1:2012(E)
3.2
composting
aerobic process designed to produce compost

NOTE Compost is an organic soil conditioner obtained by biodegradation of a mixture consisting principally of

vegetable residues, occasionally with other organic material, and having a limited mineral content.

3.3
disintegration
physical breakdown of a material into very small fragments
3.4
total dry solids

amount of solids obtained by taking a known volume of test material or compost and drying at about 105 °C to

constant mass
3.5
volatile solids

amount of solids obtained by subtracting the residue of a known volume of test material or compost after

incineration at about 550 °C from the total dry solids of the same sample

NOTE The volatile-solids content is an indication of the amount of organic matter present.

3.6
theoretical amount of evolved carbon dioxide
ThCO

maximum theoretical amount of carbon dioxide evolved after completely oxidizing a chemical compound,

calculated from the molecular formula and expressed as milligrams of carbon dioxide evolved per milligram or

gram of test compound
3.7
lag phase

time, measured in days, from the start of a test until adaptation and/or selection of the degrading microorganisms

is achieved and the degree of biodegradation of a chemical compound or organic matter has increased to

about 10 % of the maximum level of biodegradation
3.8
maximum level of biodegradation

degree of biodegradation, measured in per cent, of a chemical compound or organic matter in a test, above

which no further biodegradation takes place during the test
3.9
biodegradation phase

time, measured in days, from the end of the lag phase of a test until about 90 % of the maximum level of

biodegradation has been reached
3.10
plateau phase

time, measured in days, from the end of the biodegradation phase until the end of a test

3.11
activated vermiculite

vermiculite colonized by an active microbial population during a preliminary growth phase

4 Principle

The test method determines the ultimate biodegradability and degree of disintegration of test material under

conditions simulating an intensive aerobic composting process. The inoculum used consists of stabilized,

mature compost derived, if possible, from composting the organic fraction of solid municipal waste.

2 © ISO 2012 – All rights reserved
---------------------- Page: 7 ----------------------
ISO 14855-1:2012(E)

The test material is mixed with the inoculum and introduced into a static composting vessel where it is intensively

composted under optimum oxygen, temperature and moisture conditions for a test period not exceeding 6 months.

During the aerobic biodegradation of the test material, carbon dioxide, water, mineral salts and new microbial

cellular constituents (biomass) are the ultimate biodegradation products. The carbon dioxide produced is

continuously monitored, or measured at regular intervals, in test and blank vessels to determine the cumulative

carbon dioxide production. The percentage biodegradation is given by the ratio of the carbon dioxide produced

from the test material to the maximum theoretical amount of carbon dioxide that can be produced from the

test material. The maximum theoretical amount of carbon dioxide produced is calculated from the measured

total organic carbon (TOC) content. The percentage biodegradation does not include that amount of carbon

converted to new cell biomass which is not metabolized in turn to carbon dioxide during the course of the test.

Additionally, the degree of disintegration of the test material is determined at the end of the test, and the loss

in mass of the test material may also be determined.
Vermiculite should be used instead of mature compost

a) whenever the determination of the degree of biodegradation is affected by a priming effect induced by the

test material
and/or

b) when performing a final carbon balance with biomass determination and retrieval of the residual test material.

The vermiculite bed, being inorganic, substantially reduces the priming effect, thus improving the reliability of

the method. A further advantage of using vermiculite is the very small amount of carbon dioxide evolved in the

blank vessels (nearly zero), because of the low level of microbial activity. This permits low levels of degradation

activity to be evaluated precisely.

The mineralization rates obtained with the activated vermiculite are identical, or very similar, to those obtained

with mature compost, both in terms of the final degradation level and the degradation rate.

5 Test environment

Incubation shall be in the dark or in diffused light, in an enclosure or room maintained at a constant temperature

of 58 °C ± 2 °C and free from vapours inhibitory to microorganisms.

In special cases, e.g. when the melting point of the test material is low, another temperature may be chosen.

This temperature shall be kept constant during the test to within ±2 °C. Any change in temperature shall be

justified and clearly indicated in the test report.
6 Reagents
6.1 TLC (thin-layer chromatography) grade cellulose

Use TLC (thin-layer chromatography) grade cellulose with a particle size of less than 20 µm as the positive-

control reference material.
6.2 Vermiculite

Vermiculite is a clay mineral used for building purposes, known to be particularly suitable as a microbial carrier,

allowing survival and full activity of microbes. The composition of the native mineral, before heat treatment, is

Al O 10 %, MgO 30 %, CaO 5 %, SiO 50 % and combined H O 5 %. When the mineral is subjected to heat

2 3 2 2

treatment, it loses the combined water and expands, giving “expanded vermiculite”. Expanded vermiculite in

flake form shall be used. Expanded vermiculite has a large capacity for water storage, and a water content

comparable with that of mature compost can be obtained in the bed.
© ISO 2012 – All rights reserved 3
---------------------- Page: 8 ----------------------
ISO 14855-1:2012(E)
Vermiculite can be classified into three types, as follows:
3 3

“Concrete” type: apparent density 80 kg/m ± 16 kg/m (at the time the material is put into sacks); particle size:

80 % between 12 mm and 4 mm, 2 % passing through a 0,5 mm sieve.
3 3

“Medium” type: apparent density 90 kg/m ± 16 kg/m ; particle size: 80 % between 6 mm and 1 mm, 2 %

passing through a 0,5 mm sieve.
3 3

“Fine” type: apparent density 100 kg/m ± 20 kg/m ; particle size: 80 % between 3 mm and 0,7 mm, 5 %

passing through a 0,5 mm sieve.
For the purposes of this part of ISO 14855, the concrete type is used.
7 Apparatus

Ensure that all glassware is thoroughly cleaned and, in particular, free from organic or toxic matter.

7.1 Composting vessels: Glass flasks or bottles that allow an even gas purge in an upward direction.

A minimum volume of 2 litres is required to meet the requirements specified in 8.2 and 8.3. Depending on the

test material, a smaller volume may be used for screening purposes. If the loss in mass of the test material is

to be determined, weigh each composting vessel empty.

7.2 Air-supply system, capable of supplying each composting vessel with dry or water-saturated, if required

carbon-dioxide-free, air at a pre-set flow rate which shall be high enough to provide truly aerobic conditions

during the test (see example given in Annex A).

7.3 Apparatus for the determination of carbon dioxide, designed to determine carbon dioxide directly or by

complete absorption in a basic solution and determination of the dissolved inorganic carbon (DIC) (see example

given in Annex A). If the carbon dioxide in the exhaust air is measured directly, for example with a continuous

infrared analyser or a gas chromatograph, exact control or measurement of the air-flow rate is required.

7.4 Gas-tight tubes, to connect the composting vessels with the air supply and the carbon dioxide

measurement system.
7.5 pH-meter.

7.6 Analytical equipment, for the determination of dry solids (at 105 °C), volatile solids (at 550 °C) and

total organic carbon (TOC), for elemental analysis of the test material and, if required, for the determination of

dissolved inorganic carbon (DIC).

7.7 Balance (optional), to measure the mass of test vessels containing compost and test material, which is

normally in the range between 3 kg and 5 kg.

7.8 Analytical equipment (optional), for the determination of oxygen in the air, moisture, volatile fatty acids

and total nitrogen (e.g. by the Kjeldahl method as specified in ISO 5663).

7.9 Bioreactors for activation of the vermiculite: Containers, with a volume between 5 l and 20 l, which

are not actively aerated. The containers shall be closed in such a way as to avoid excessive drying out of the

contents. Openings shall, however, be provided to allow gas exchange with the atmosphere and ensure aerobic

conditions throughout the activation phase.

An example of a suitable bioreactor is a box, made of polypropylene or another suitable material, having the

following dimensions: 30 cm × 20 cm × 10 cm (l, w, h). The box shall have a tightly fitting lid in order to avoid

excessive loss of water vapour. In the middle of the two 20-cm-wide sides, a hole 5 mm in diameter shall be

4 © ISO 2012 – All rights reserved
---------------------- Page: 9 ----------------------
ISO 14855-1:2012(E)

made at a height of about 6,5 cm from the bottom of the box. It is these two holes which allow gas exchange

between the atmosphere inside the box and the outside environment.
8 Procedure
8.1 Preparation of the inoculum

Well aerated compost from a properly operating aerobic composting plant shall be used as the inoculum. The

inoculum shall be homogeneous and free from large inert objects such as glass, stones or pieces of metal.

Remove them manually and then sieve the compost on a screen of about 0,5 cm to 1 cm.

NOTE 1 It is recommended that compost from a plant composting the organic fraction of solid municipal waste be used

in order to ensure sufficient diversity of microorganisms. The age of the compost should preferably be between 2 and 4

months. If such compost is not available, compost from plants treating garden or farmyard waste or mixtures of garden

waste and solid municipal waste may be used.

NOTE 2 It is recommended that compost with sufficient porosity be used to enable aerobic conditions to be maintained

as much as possible. Addition of structural material such as small wood particles or inert or poorly biodegradable material

may prevent the compost sticking together and clogging during the test.

Determine the total dry solids and the volatile-solids content of the inoculum. The total dry solids content shall

be between 50 % and 55 % of the wet solids and the volatile solids shall be more than about 15 % of the wet

(or 30 % of the dry) solids. Adjust the water content, if necessary, before the compost is used by adding water

or gentle drying, e.g. by aerating the compost with dry air.

Prepare a mixture of 1 part of inoculum with 5 parts of deionized water. Mix by shaking and measure the pH

immediately. It shall be between 7,0 and 9,0.

NOTE 3 For further characterization of the inoculum, suitable parameters such as the content of total organic carbon,

total nitrogen or fatty acids can optionally be determined at the beginning and the end of the test.

Check the activity of the inoculum during the test by means of a biodegradable reference material (see Clause 6)

and by measuring the carbon dioxide evolution in the blank vessels. The reference material shall be degraded

by 70 % or more at the end of the test (see Clause 10). The inoculum in the blank shall produce between 50 mg

and 150 mg of carbon dioxide per gram of volatile solids over the first 10 days of the test (see Clause 10). If the

production of carbon dioxide is too high, stabilize the compost by aeration for several days before using it in a

new test. If the activity is too low, use another compost for the inoculum.
8.2 Preparation of test material and reference material

Determine the total organic carbon (TOC) of the test material and the reference material using e.g. ISO 8245

and report it, preferably, as grams of TOC per gram of total dry solids. Alternatively, provided the materials do

not contain inorganic carbon, it is possible to determine the carbon content by elemental analysis. The test

material shall have sufficient organic carbon to yield carbon dioxide in an amount suitable for the determination.

Normally, a minimum of 50 g of total dry solids containing 20 g of TOC is required per vessel.

If the loss in mass is to be determined, determine the total dry solids and volatile solids of the test material.

NOTE The loss in mass of the test material and reference material during the test can be determined, optionally, as

additional information. In the example given in Annex C, the volatile-solids content of the test material is determined at the

beginning of the test and compared with that at the end of the test.

Use test material in the form of granules, powder, film or simple shapes (e.g. dumb-bells). The maximum

surface area of any individual piece of test material shall be about 2 cm × 2 cm. If any pieces in the original test

material are larger, reduce them in size.
© ISO 2012 – All rights reserved 5
---------------------- Page: 10 ----------------------
ISO 14855-1:2012(E)
8.3 Start-up of the test
Set up at least the following numbers of composting vessels (7.1):
a) three vessels for the test material;
b) three vessels for the reference material;
c) three vessels for the blank.

The amount of test mixture, containing inoculum and test material, used in the test will depend on the quality of

the test material (see 8.2) and the size of the composting vessels. The ratio of the dry mass of the inoculum to

the dry mass of the test material shall be about 6:1. Be sure that the same amount of compost is in each vessel.

Inert material, if added (see Note 2 to 8.1), is not considered in this relationship. Fill about three-quarters of the

volume of the composting vessel with the test mixture. Leave sufficient headspace to allow manual shaking of

the test mixture.

In a typical case, prepare composting vessels which have a volume of about 3 litres, weigh out an amount of

inoculum containing 600 g of total dry solids and an amount of test material containing 100 g of dry solids and

mix well. The test mixture shall have the same water content (about 50 %) as the inoculum (see 8.1). It should

feel somewhat sticky and have some free water available when gently pressed by hand. Adjust the moisture

content of the mixture, if required, by adding water or by aerating with dry air. Introduce the mixture into the

composting vessels.

NOTE 1 It is recommended that the ratio between organic carbon and nitrogen (C/N ratio) of the test mixture is optimized

so as to ensure a good composting process. The C/N ratio for the test mixture should preferably be between 10 and 40. It

may be adjusted with urea, if necessary. The organic-carbon content can be calculated from the TOC of the inoculum and

the test material. The total nitrogen content can be measured in a representative sample of the test mixture, e.g. by using

the Kjeldahl method as specified in ISO 5663.

Place the composting vessels in the test environment at 58 °C ± 2 °C (see Clause 5) and initiate aeration using

water-saturated, carbon-dioxide-free air. This can be produced by passing the air through wash-bottles filled

with sodium hydroxide solution (see Annex A).

NOTE 2 Normal air, rather than carbon-dioxide-free air, can be used if the carbon dioxide concentration in the exhaust air

is directly measured. In this case, measurement of the carbon dioxide concentration at the inlet and outlet of each test vessel

is recommended. For correction, subtract the inlet concentration from the outlet concentration (which will be much higher).

Use a sufficiently high flow rate to ensure that aerobic conditions are maintained during the test throughout

each composting vessel. Check the air flow regularly at each outlet, e.g. by using wash-bottles, to ensure that

there are no leaks in any part of the system.

NOTE 3 Regular measurement of the oxygen concentration in the exhaust air from the composting vessels will help

maintain aerobic conditions. If this is done, the oxygen concentration should not be allowed to drop below about 6 %.

Oxygen levels should be closely monitored during the fi
...

NORME ISO
INTERNATIONALE 14855-1
Deuxième édition
2012-12-01
Évaluation de la biodégradabilité aérobie
ultime des matériaux plastiques dans des
conditions contrôlées de compostage —
Méthode par analyse du dioxyde de
carbone libéré —
Partie 1:
Méthode générale
Determination of the ultimate aerobic biodegradability of plastic
materials under controlled composting conditions — Method by analysis
of evolved carbon dioxide —
Part 1: General method
Numéro de référence
ISO 14855-1:2012(F)
ISO 2012
---------------------- Page: 1 ----------------------
ISO 14855-1:2012(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2012

Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous

quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord écrit

de l’ISO à l’adresse ci-après ou du comité membre de l’ISO dans le pays du demandeur.

ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2012 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 14855-1:2012(F)
Sommaire Page

Avant-propos .....................................................................................................................................................................iv

Introduction ........................................................................................................................................................................ v

1 Domaine d’application ....................................................................................................................................... 1

2 Références normatives ...................................................................................................................................... 1

3 Termes et définitions .......................................................................................................................................... 1

4 Principe .................................................................................................................................................................. 2

5 Environnement d’essai ...................................................................................................................................... 3

6 Réactifs .................................................................................................................................................................. 3

6.1 Cellulose de qualité CCM (chromatographie sur couche mince) ........................................................... 3

6.2 Vermiculite ............................................................................................................................................................. 3

7 Appareillage .......................................................................................................................................................... 4

8 Mode opératoire ................................................................................................................................................... 5

8.1 Préparation de l’inoculum ................................................................................................................................. 5

8.2 Préparation du matériau d’essai et de la substance de référence ......................................................... 5

8.3 Début de l’essai ................................................................................................................................................... 6

8.4 Période d’incubation .......................................................................................................................................... 7

8.5 Fin de l’essai ......................................................................................................................................................... 7

8.6 Utilisation de la vermiculite .............................................................................................................................. 8

8.7 Mode opératoire de récupération et bilan carbone lors de l’utilisation de la vermiculite ............... 9

9 Calcul et expression des résultats ................................................................................................................. 9

9.1 Calcul de la teneur théorique en dioxyde de carbone ............................................................................... 9

9.2 Calcul du pourcentage de biodégradation ................................................................................................... 9

9.3 Calcul des pertes de masse ...........................................................................................................................10

9.4 Expression des résultats .................................................................................................................................10

10 Validité des résultats ........................................................................................................................................10

11 Rapport d’essai ..................................................................................................................................................10

Annexe A (informative) Principe de fonctionnement d’un système d’essai .....................................................12

Annexe B (informative) Exemples de représentation graphique des courbes de libération de dioxyde de

carbone et de biodégradation ........................................................................................................................14

Annexe C (informative) Exemple de détermination des pertes de masse ........................................................16

Annexe D (informative) Essai interlaboratoires........................................................................................................18

Annexe E (informative) Exemples de fiches techniques........................................................................................19

Bibliographie ....................................................................................................................................................................22

© ISO 2012 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 14855-1:2012(F)
Avant-propos

L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de

normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en général confiée aux

comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité

technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales,

en liaison avec l’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission

électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.

Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 2.

La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de Normes

internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur publication

comme Normes internationales requiert l’approbation de 75 % au moins des comités membres votants.

L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de droits

de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de ne pas avoir

identifié de tels droits de propriété et averti de leur existence.

L’ISO 14855-1 a été élaborée par le comité technique ISO/TC 61, Plastiques, sous-comité SC 5, Propriétés

physicochimiques.

Cette deuxième édition annule et remplace la première édition (ISO 14855-1:2005), dont elle constitue une

révision mineure destinée principalement à clarifier le texte du quatrième alinéa du Paragraphe 8.1. Par ailleurs,

la note de bas de page en 6.2 relative à un éventuel fournisseur de vermiculite type béton a été supprimée car

il apparaît qu’elle n’est plus valable.

Cette deuxième édition annule et remplace également le Rectificatif technique ISO 14855-1:2005/Cor.1:2009.

L’ISO 14855 comprend les parties suivantes, présentées sous le titre général Évaluation de la biodégradabilité

aérobie ultime des matériaux plastiques dans des conditions contrôlées de compostage — Méthode par

analyse du dioxyde de carbone libéré:
— Partie 1: Méthode générale

— Partie 2: Mesurage gravimétrique du dioxyde de carbone libéré lors d’un essai de laboratoire

iv © ISO 2012 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 14855-1:2012(F)
Introduction

La méthode principale spécifiée dans la présente partie de l’ISO 14855 utilise un essai respirométrique en

phase solide d’un compost mature utilisé comme lit solide, source de nutriments, et d’un inoculum riche en

micro-organismes thermophiles. Le compost mature est une substance très hétérogène et complexe. Il peut

donc être difficile de quantifier le matériau polymère résiduel dans le lit à la fin de l’essai, afin de détecter

d’éventuelles molécules à faible masse moléculaire dégagées dans le lit solide par le matériau polymère durant

la dégradation, et d’évaluer la biomasse. En conséquence, il peut être difficile de réaliser un bilan carbone

complet. Une autre difficulté parfois rencontrée avec le compost mature est un «effet d’activation»: la matière

organique qui est présente en grandes quantités dans le compost mature peut subir une dégradation induite

par le polymère, connue sous le nom d’«effet d’activation», perturbant le mesurage de la biodégradabilité.

Pour surmonter ces difficultés et améliorer la fiabilité de la méthode d’essai, le compost mature peut être

remplacé par un milieu minéral solide, qui est utilisé comme lit de compostage facilitant ainsi les analyses. La

méthode d’essai peut être appliquée pour mesurer la biodégradation par le CO libéré, pour quantifier et analyser

la biomasse et les résidus de matériau polymère subsistant dans le lit solide à l’issue de l’essai, et réaliser un

bilan carbone complet. En outre, la méthode d’essai n’est pas sensiblement affectée par l’effet d’activation et

peut, par conséquent, être utilisée pour mettre à l’essai des substances d’essai qui sont réputées causer ce

problème avec le compost mature. Le lit minéral peut aussi être soumis à une analyse écotoxicologique afin de

vérifier l’absence d’activité écotoxique dans le lit après biodégradation.
© ISO 2012 – Tous droits réservés v
---------------------- Page: 5 ----------------------
NORME INTERNATIONALE ISO 14855-1:2012(F)
Évaluation de la biodégradabilité aérobie ultime des matériaux
plastiques dans des conditions contrôlées de compostage —
Méthode par analyse du dioxyde de carbone libéré —
Partie 1:
Méthode générale

AVERTISSEMENT — Les eaux usées, les boues activées et les matières en suspension dans le sol

et le compost peuvent contenir des organismes potentiellement pathogènes. Il convient donc de les

manipuler avec les précautions appropriées, de même que les composés à analyser toxiques ou dont

les propriétés ne sont pas connues.
1 Domaine d’application

La présente partie de l’ISO 14855 prescrit une méthode d’évaluation, d’une part, de la biodégradabilité aérobie

ultime des plastiques à partir de composés organiques dans des conditions contrôlées de compostage, par

mesurage du dioxyde de carbone libéré, et d’autre part, de leur désintégration à la fin de l’essai. La présente

méthode est conçue pour se rapprocher des conditions de compostage aérobies caractéristiques de la fraction

organique des déchets municipaux solides non triés. Le matériau d’essai est exposé dans le cadre d’un essai

de laboratoire à un inoculum provenant d’un échantillon de compost. Le compostage aérobie a lieu dans

un environnement où la température, l’aération et l’humidité, en particulier, sont étroitement contrôlées et

maîtrisées. La méthode permet d’accéder au pourcentage et au taux de conversion du carbone contenu dans

la substance à analyser, en dioxyde de carbone libéré.

Les paragraphes 8.6 et 8.7 spécifient une variante de la méthode utilisant un lit minéral de vermiculite,

ensemencé par des micro-organismes thermophiles obtenus à partir d’un compost à une phase d’activation

spécifique, à la place d’un compost mature. Cette variante a pour objet de permettre d’obtenir un pourcentage

et un taux de conversion du carbone de la substance d’essai en dioxyde de carbone dégagé.

Les conditions utilisées dans la présente partie de l’ISO 14855 ne correspondent pas nécessairement aux

conditions optimales permettant d’obtenir le taux maximal de biodégradation.
2 Références normatives

Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les

références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du

document de référence s’applique (y compris les éventuels amendements).

ISO 5663, Qualité de l’eau — Dosage de l’azote Kjeldahl — Méthode après minéralisation au sélénium

ISO 8245, Qualité de l’eau — Lignes directrices pour le dosage du carbone organique total (COT) et du

carbone organique dissous (COD)
3 Termes et définitions

Pour les besoins du présent document, les termes et définitions suivants s’appliquent.

3.1
biodégradation aérobie ultime

décomposition d’un composé chimique organique par des micro-organismes en présence d’oxygène, en

dioxyde de carbone, eau et sels minéraux de tous les autres éléments présents (minéralisation) et en une

nouvelle biomasse
© ISO 2012 – Tous droits réservés 1
---------------------- Page: 6 ----------------------
ISO 14855-1:2012(F)
3.2
compostage
procédé aérobie destiné à produire du compost

NOTE Le compost est un conditionneur organique du sol obtenu par biodégradation d’un mélange principalement

constitué de divers résidus végétaux éventuellement associés à un autre matériau organique, et ayant une teneur en

minéraux limitée.
3.3
désintégration
cassure physique d’un matériau en très petits fragments
3.4
matières sèches totales

quantité de solides obtenue par prélèvement d’un volume connu de matériau d’essai ou de compost, et séchage

à environ 105 °C jusqu’à l’obtention d’une masse constante
3.5
solides volatils

quantité de solides obtenue par soustraction des résidus d’un volume connu de matériau d’essai ou de compost

après incinération à environ 550 °C, de la teneur en matières sèches totales du même échantillon

NOTE La teneur en solides volatils est symptomatique de la teneur en matière organique.

3.6
teneur théorique de dioxyde de carbone libéré
ThCO

teneur théorique maximale en dioxyde de carbone libéré après oxydation complète d’un composé chimique,

calculée d’après la formule moléculaire, exprimée en milligrammes de dioxyde de carbone libéré par milligramme

ou gramme de composé à analyser
3.7
phase de latence

durée, mesurée en jours, écoulée à partir du début de l’essai jusqu’à l’obtention de l’adaptation et/ou de la

sélection des micro-organismes qui provoquent la dégradation, et jusqu’à ce que le taux de biodégradation du

composé chimique ou de la matière organique ait atteint environ 10 % du niveau maximal de biodégradation

3.8
niveau maximal de biodégradation

degré de biodégradation, mesuré en pourcentage, d’un composé chimique ou d’un matériau organique lors

d’un essai, au-dessus duquel la biodégradation ne se poursuit pas
3.9
phase de biodégradation

durée, mesurée en jours, depuis la fin de la phase de latence de l’essai jusqu’à ce que l’on ait obtenu environ

90 % du niveau maximal de biodégradation
3.10
phase stationnaire

durée, mesurée en jours, écoulée entre la fin de la phase de biodégradation et la fin de l’essai

3.11
vermiculite activée

vermiculite colonisée par une population microbienne active durant une phase de croissance préliminaire

4 Principe

La méthode d’essai permet de déterminer la biodégradabilité ultime et la désintégration d’un matériau d’essai

dans des conditions simulant un processus de compostage aérobie intensif. L’inoculum est un compost stabilisé

et mature, obtenu si possible à partir du compostage de la fraction organique des déchets municipaux solides.

2 © ISO 2012 – Tous droits réservés
---------------------- Page: 7 ----------------------
ISO 14855-1:2012(F)

Le matériau d’essai est mélangé à l’inoculum et introduit dans un récipient de compostage statique où il est

transformé en compost dans des conditions optimales du point de vue de l’oxygène présent, de la température

et de l’humidité, pendant une durée d’essai ne dépassant pas 6 mois.

Pendant la biodégradation aérobie du matériau d’essai, les produits de la biodégradation ultime sont le dioxyde

de carbone, l’eau, des sels minéraux et de nouveaux constituants cellulaires microbiens (biomasse). Le dioxyde

de carbone produit est contrôlé en continu ou mesuré à intervalles réguliers dans les récipients d’essai et

du blanc, puis intégré pour déterminer la production cumulée de dioxyde de carbone. Le pourcentage de

biodégradation s’obtient en comparant le dioxyde de carbone produit par le matériau d’essai à la quantité

maximale de dioxyde de carbone qui pourrait être obtenue à partir du matériau d’essai et qui est calculée

à partir du carbone organique total mesuré (COT). Ce pourcentage de biodégradation ne comprendra pas

la quantité de carbone convertie en nouvelle biomasse cellulaire qui n’a pas été métabolisée en dioxyde de

carbone au cours de l’essai.

En outre, on détermine la désintégration d’un matériau d’essai compact à la fin de l’essai, et la perte de masse

subie par le matériau d’essai peut également être déterminée.
Il convient d’utiliser de la vermiculite à la place de compost mature

a) chaque fois que l’évaluation de la biodégradation est compromise par un effet d’activation induit par le

matériau d’essai
et/ou

b) pour réaliser un bilan final du carbone avec détermination de la biomasse et récupération des résidus du

matériau d’essai.

Du fait que la vermiculite est un lit inorganique, elle réduit substantiellement l’effet d’activation, améliorant la

fiabilité de la méthode d’essai. Un autre avantage de l’utilisation de la vermiculite est la très faible valeur du

dioxyde de carbone libéré dans les réacteurs à blanc de l’essai (proche de zéro), à cause de la faible activité

microbienne. C’est pourquoi des activités de dégradation faible peuvent aussi être évaluées avec exactitude.

Les taux de minéralisation obtenus avec la vermiculite activée sont identiques, ou très semblables, à ceux

obtenus avec le compost mature, à la fois au niveau de la dégradation finale et du taux de dégradation.

5 Environnement d’essai

L’incubation doit avoir lieu dans l’obscurité ou sous une lumière diffuse, dans une enceinte devant être

maintenue à une température constante de 58 °C ± 2 °C et exempte de vapeurs susceptibles d’inhiber les

micro-organismes.

Dans certains cas, par exemple lorsque le point de fusion du matériau d’essai est bas, il est possible de retenir

une autre température. La température en question doit être maintenue constante à ±2 °C près tout au long de

l’essai. Tout changement de température doit être justifié et clairement indiqué dans le rapport d’essai.

6 Réactifs
6.1 Cellulose de qualité CCM (chromatographie sur couche mince)

Utiliser comme matériau de référence pour le témoin positif de la cellulose de qualité CCM (pour chromatographie

sur couche mince) ayant une granulométrie inférieure à 20 µm.
6.2 Vermiculite

La vermiculite est un minéral argileux utilisé pour la construction, connu pour convenir particulièrement bien en

tant que support microbien autorisant la survie et l’activité complète des microbes. La composition du minéral

natif, avant traitement à chaud, est la suivante: Al O 10 %, MgO 30 %, CaO 5 %, SiO 50 % et H O 5 %

2 3 2 2

combinée. Quand le minéral est soumis à un traitement thermique, il perd sa teneur en eau et se dilate, pour

se transformer en «vermiculite expansée». On doit utiliser de la vermiculite expansée sous forme de flocons.

© ISO 2012 – Tous droits réservés 3
---------------------- Page: 8 ----------------------
ISO 14855-1:2012(F)

La vermiculite expansée a une grande capacité de stockage de l’eau et une teneur en eau comparable à celle

du compost mature peut être obtenue dans ce lit minéral.
La vermiculite peut être classée en trois types comme suit:
3 3

Type «béton»: masse volumique apparente 80 kg/m ± 16 kg/m (au moment de la mise en sacs); granulométrie:

80 % entre 12 mm et 4 mm, 2 % inférieure à 0,5 mm;
3 3

Type «moyen»: masse volumique apparente 90 kg/m ± 16 kg/m ; granulométrie: 80 % entre 6 mm et 1 mm,

2 % inférieure à 0,5 mm;
3 3

Type «fin»: masse volumique apparente 100 kg/m ± 20 kg/m ; granulométrie: 80 % entre 3 mm et 0,7 mm,

5 % inférieure à 0,5 mm.

Pour les besoins de la présente partie de l’ISO 14855, le type béton est utilisé.

7 Appareillage

S’assurer que toute la verrerie de laboratoire a été soigneusement nettoyée et, en particulier, qu’elle est

exempte de toute trace de substances organiques ou toxiques.

7.1 Récipients de compostage: flacons ou fioles en verre, produisant un courant ascendant régulier de gaz.

Un volume minimal de 2 l est nécessaire pour satisfaire aux prescriptions de 8.2 et 8.3. Pour le tamisage,

selon le matériau d’essai employé, il est également possible d’utiliser un plus petit volume. Si l’on détermine les

pertes de masse subies par le matériau d’essai, peser chaque récipient de compostage à vide.

7.2 Système de production d’air, pouvant alimenter chaque récipient de compostage en air sec ou saturé

en eau, si nécessaire exempt de dioxyde de carbone, au débit prédéfini. Ce débit doit être suffisamment élevé

pour créer des conditions véritablement aérobies durant l’essai (voir l’exemple donné dans l’Annexe A).

7.3 Appareillage pour la détermination du dioxyde de carbone, permettant de déterminer à la fois

le dioxyde de carbone directement ou après absorption complète dans une solution basique, et le carbone

inorganique dissous (CID) (voir l’exemple donné dans l’Annexe A). Si l’air de sortie est mesuré directement,

par exemple au moyen d’un analyseur continu à infrarouge ou d’un appareil de chromatographie en phase

gazeuse, un dosage ou mesurage exact du débit d’air est nécessaire.

7.4 Tubes étanches aux gaz, pour raccorder les récipients de compostage au système de production d’air

et au dispositif de détermination du dioxyde de carbone.
7.5 pH-mètre.

7.6 Appareillage analytique, pour la détermination des matières sèches (à 105 °C), des solides volatils (à

550 °C) et du carbone organique total (COT), ou pour l’analyse élémentaire du matériau d’essai et, si besoin

est, pour la détermination du carbone inorganique dissous (CID).

7.7 Balance (facultative), permettant de peser les récipients d’essai remplis de compost et de matériau

d’essai (masse normalement comprise entre 3 kg et 5 kg).

7.8 Appareillage analytique (facultatif), pour la détermination de l’oxygène dans l’air, de l’humidité, des

acides gras volatils et de l’azote total (par exemple par la méthode de Kjeldahl spécifiée dans l’ISO 5663).

7.9 Bioréacteurs pour l’activation de la vermiculite: Récipients de 5 l à 20 l de contenance, qui ne sont pas

activement aérés. Les récipients doivent être fermés de façon à éviter tout dessèchement excessif du contenu.

4 © ISO 2012 – Tous droits réservés
---------------------- Page: 9 ----------------------
ISO 14855-1:2012(F)

Dans le même temps, des ouvertures doivent être assurées de façon à permettre les échanges gazeux et

assurer des conditions aérobies tout au long de la phase d’activation.

Un exemple de bioréacteur fait en polypropylène ou en un autre matériau adapté, ayant les dimensions

suivantes: 30 cm × 20 cm × 10 cm (longueur, largeur, hauteur). La boîte doit être fournie avec un couvercle

assurant une fermeture étanche afin d’éviter un dégagement excessif de vapeur d’eau. Au milieu des deux

parois latérales de 20 cm de large, un trou de 5 mm de diamètre doit être pratiqué à une hauteur d’environ

6,5 cm du fond de la boîte. Ces deux trous permettent l’échange gazeux entre l’atmosphère intérieure et

l’environnement extérieur.
8 Mode opératoire
8.1 Préparation de l’inoculum

Utiliser comme inoculum du compost bien aéré provenant d’une installation de compostage aérobie

convenablement exploitée. L’inoculum de compost doit être homogène et exempt d’objets inertes de grandes

dimensions tels que verre, cailloux ou fragments de métal. Retirer ceux-ci à la main, puis tamiser le compost

sur un tamis d’environ 0,5 cm à 1 cm.

NOTE 1 Il est recommandé d’utiliser du compost provenant d’une installation de compostage de la fraction organique

des déchets municipaux solides, de façon à obtenir une gamme suffisante de micro-organismes. Il convient d’utiliser, de

préférence, un compost ayant entre 2 mois et 4 mois. Si l’on ne dispose pas de ce type de compost, on peut également

utiliser du compost provenant d’installations qui traitent des déchets végétaux ou des mélanges de déchets végétaux et

de déchets municipaux solides.

NOTE 2 Il est recommandé d’utiliser du compost de porosité suffisante pour permettre l’obtention de conditions aussi

aérobies que possible. L’ajout d’éléments structuraux comme de petites particules de bois ou de la matière inerte persistante

ou faiblement biodégradable peut empêcher le compost de devenir collant ou de s’agglomérer au cours de l’essai.

Déterminer la teneur en matières sèches totales et en solides volatils de l’inoculum de compost. La teneur en

matières sèches totales doit être comprise entre 50 % et 55 % des matières humides et la teneur en solides

volatils doit être supérieure à environ 15 % des matières humides (ou 30 % des matières sèches). Ajuster la

teneur en eau, si nécessaire, avant utilisation du compost en ajoutant de l’eau ou par un séchage modéré, en

aérant, par exemple, le compost avec de l’air sec.

Préparer un mélange d’une partie d’inoculum de compost avec cinq parties d’eau déionisée. Mélanger en

agitant et immédiatement mesurer le pH, qui doit être compris entre 7,0 et 9,0.

NOTE 3 Pour la caractérisation ultérieure de l’inoculum de compost, on peut éventuellement déterminer des paramètres

appropriés tels que la teneur en carbone organique total, en azote total ou en acides gras, au début et à la fin de l’essai.

Vérifier l’activité de l’inoculum de compost pendant l’essai au moyen d’un matériau de référence biodégradable

(voir l’Article 6) et en mesurant l’évolution du dioxyde de carbone dans les récipients du blanc. À la fin de l’essai,

le matériau de référence doit être dégradé à plus de 70 % (voir l’Article 10). L’inoculum du blanc doit produire

entre 50 mg et 150 mg de dioxyde de carbone par gramme de solides volatils, pendant les 10 premiers jours

de l’essai (voir l’Article 10). Si la production de dioxyde de carbone est trop élevée, stabiliser le compost par

aération pendant plusieurs jours avant de l’utiliser dans le cadre d’un nouvel essai. En revanche, si l’activité est

trop faible, utiliser un nouvel inoculum de compost.
8.2 Préparation du matériau d’essai et de la substance de référence

Déterminer la teneur en carbone organique total (COT) du matériau d’essai et du matériau de référence (en

utilisant, par exemple, l’ISO 8245) et l’exprimer, de préférence, en grammes de COT par gramme de matières

sèches totales. Une autre solution consiste à déterminer la teneur en carbone par une analyse élémentaire

si les matériaux ne contiennent pas de carbone inorganique. Le matériau d’essai doit contenir suffisamment

de carbone organique pour permettre l’obtention d’une quantité de dioxyde de carbone appropriée à la

détermination. Normalement, un minimum de 50 g de matières sèches totales contenant 20 g de COT est

nécessaire par récipient.
© ISO 2012 – Tous droits réservés 5
---------------------- Page: 10 ----------------------
ISO 14855-1:2012(F)

S’il est nécessaire de déterminer les pertes de masse, déterminer la teneur en matières sèches totales du

matériau d’essai, ainsi que la teneur en solides volatils.

NOTE Les pertes de masse subies pendant l’essai par le matériau d’essai et le matériau de référence peuvent

éventuellement être déterminées à titre d’informations complémentaires. Dans l’exemple donné dans l’Annexe C, la teneur

du matériau d’essai en solides volatils est déterminée au début de l’essai et comparée à celle obtenue à la fin de l’essai.

Utiliser des matériaux d’essai sous forme de granulés, de poudres, de films ou de formes simples (par exemple

sous forme d’haltères). Tout fragment individuel de matériau d’essai compact utilisé doit avoir une surface maximale

d’environ 2 cm × 2 cm. Si le matériau d’essai d’origine a une taille supérieure, réduire la taille des fragments.

8.3 Début de l’essai
Prévoir au moins les nombres suivants de récipients de compostage (7.1):
a) trois récipients pour le matériau d’essai;
b) trois récipients pour le matériau de référence;
c) trois récipients pour le blanc.

La quantité de mélange d’essai contenant l’inoculum de compost et le matériau d’essai, utilisée lors de l’essai,

dépend de la qualité du matériau d’essai (voir 8.2) et de la taille des récipients de compostage. Le rapport de

la masse à sec de l’inoculum de compost à celle du matériau d’essai doit être d’environ 6:1. S’assurer que

chaque récipient contient la même quantité de compost. Tout matériau inerte éventuellement ajouté (voir la

note 2 en 8.1) n’est pas pris
...