Photography — Light sources for use in sensitometric exposure — Simulation of the spectral distribution of photoflood illumination

Photographie — Sources de lumière destinées à l'exposition sensitométrique — Reproduction de la distribution spectrale des lampes survoltées

General Information

Status
Withdrawn
Publication Date
30-Sep-1972
Withdrawal Date
30-Sep-1972
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
01-Oct-1984
Ref Project

Relations

Buy Standard

Standard
ISO 2242:1972 - Photography -- Light sources for use in sensitometric exposure -- Simulation of the spectral distribution of photoflood illumination
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 2242:1972 - Photography — Light sources for use in sensitometric exposure — Simulation of the spectral distribution of photoflood illumination Released:10/1/1972
French language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION .MEWlYHAPOnHAR OPrAHR3AUMR no CTAHJlAPTM3AUWM *ORGANISATION INTERNATIONALE DE NORMALISATION
Photography -
Light sources for use in sensitometric exposure -
Simulation of the spectral distribution
of photoflood i I I u mi nat ion
First edition - 1972-10-15
-
w
UDC 771.449.7 Ref. No. IS0 2242-1972 (E)
-
N
pi
m
c
Descriptors : photography, light sources, sensitometers, spectral energy distribution, simulation, photographic flood lights
64
P N
N
Price based on 3 pages

---------------------- Page: 1 ----------------------
FOREWORD
IS0 (the International Organization for Standardization) is a worldwide federation
of national standards institutes (IS0 Member Bodies). The work of developing
International Standards is carried out through IS0 Technical Committees. Every
Member Body interested in a subject for which a Technical Committee has been set
up has the right to be represented on that Committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work.
Draft International Standards adopted by the Technical Committees are circulated
as International
to the Member Bodies for approval before their acceptance
Standards by the IS0 Council.
International Standard IS0 2242 was drawn up by Technical Committee
iSO/TC 42, Photography.
It was approved in September 1971 by the Member Bodies of the following
countries :
Belgium Japan Thailand
Czechoslovakia New Zealand United Kingdom
Egypt, Arab Rep. of Romania U.S.A.
France South Africa, Rep. of U.S.S.R.
Germany Spain
Italy Switzerland
No Member Body expressed disapproval of the document.
O International Organization for Standardization, 1972
Printed in Switzerland

---------------------- Page: 2 ----------------------
I NTE RNATl ON AL STAN DARD IS0 2242-1972 (E)
Photography -
Light sources for use in sensitometric exposure -
Simulation of the spectral distribution
of photoflood il lu mination
O INTRODUCTION transmittance which best characterizes a representative
camera lens, the values given in Table 3 are considered
Colour films at present available for photography with
reasonable and adequate for the intended purpose of this
artificial light are of two types. One type is balanced for
International Standard.
exposure to incandescent tungsten sources operated at a
colour temperature of 3 200 K; the other is balanced for
incandescent tungsten sources operated at 3 400 K. The
sensitometric illuminant described in this International 1 SCOPE AND FIELD OF APPLICATION
Standard is intended for use with the latter (3 400 K).
This International Standard specifies requirements for light
In this International Standard the specifications of the sources appropriate for use in the sensitometric exposure of
spectral energy distribution for the sensitometric illuminant photographic materials, both monochrome and colour. The
are derived from the spectral energy distribution of a black spectral quality of the exposing radiant energy closely
body having a colour temperature of 3 400 K modified by matches the spectral energy distribution of average
photoflood illumination modified by the spectral
the spectral transmittance values for a representative
transmittance of a representative camera lens (see Table 3).
camera lens as given in Table 3. Although further study is
L
exclusive of the infrared.
required to establish with certainty the spectral
1

---------------------- Page: 3 ----------------------
IS0 2242 -1972 (E)
.-
TABLE 2 - Relative spectral energy distribution of standard
2 LIGHT SOURCE
'
sensitometric photoflood'
Wavelength Interval
inergy/Total energy
lelative energ)
sum
nm
360 2,7
2.1 General requirements
370 6.7
The light source shall be a lamp operated at a condition
11.3
380
such that, with an absorbing filter if necessary, the energy
16.0
390
incident on the exposure plane of the sensitometer will
5812 871 = 0,020
21 ,O 57,7
400
have, within the limits shown in Table 1, the sp
...

NORME INTERNATIONALE
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION *MEXKnYHAPOKnHAR OPiAHHJAUillI no CiAHKnAPTHSAUHH*ORGANlSATION INTERNATIONALE DE NORMALISATION
L Photographie -
Sources de lumière destinées à l'exposition sensitométrique -
Reproduction de la distribution spectrale
des lampes survoltées
Première édition - 1972-10-15
Réf. NO : IS0 2242-1972 (F)
CDU 771.449.7
N
h
Descripteurs : photographie, source lumineuse, sensitomhe, répartition spectrale d'énergie, simulation, lampe d'éclairage survoltée.
N
N
N
Prix basé sur 3 pages
s

---------------------- Page: 1 ----------------------
_-
AVANT-PROPOS
IS0 (Organisation Internationale de Normalisation) est une fédération mondiale
d’organismes nationaux de normalisation (Comités Membres ISO). L’élaboration de
Normes Internationales est confiée aux Comités Techniques ISO. Chaque Comité
Membre intéressé par une étude a le droit de faire partie du Comité Technique
correspondant. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec I’ISO, participent également aux travaux.
Les Projets de Normes Internationales adoptés par les Comités Techniques sont
soumis aux Comités Membres pour approbation, avant leur acceptation comme
Normes Internationales par le Conseil de I’ISO.
La Norme Internationale IS0 2242 a été établie par le Comité Technique
42, Photographie.
ISO/TC
Elle fut approuvée en septembre 1971 par les Comités Membres des pays suivants :
Afrique du Sud, Rép. d‘ Italie Tchécoslovaquie
Japon Thaïlande
Allemagne
Belgique Nouvel leZélande U.R S.S.
Egypte, Rép. arabe d‘ Roumanie U.S.A.
Espagne Royaume-Uni
France Suisse
Aucun Comité Membre n’a désapprouvé le document.
Q Organisation Internationale de Normalisation, 1972 0
Imprimé en Suisse

---------------------- Page: 2 ----------------------
NORME INTERNATIONALE IS0 2242-1972 (F)
.-
Photographie -
Sources de lumière destinées à l'exposition sensitométrique -
Reproduction de la distribution spectrale
des lampes survoltées
L
est encore un
O INTRODUCTION transmission spectrale d'un objectif moyen
sujet d'étude mais dans le cadre de la présente Norme
Les pellicules en couleur actuellement disponibles pour la
Internationale, les valeurs données dans le Tableau 3 sont
photographie à la lumière artificielle sont de deux types.
considérées comme valables.
L'un d'eux est équilibré pour l'exposition à des sources au
tungstène portées à la température de couleur de 3 200 K;
l'autre est équilibré pour des sources au tungstène portées a
1 OBJET ET DOMAINE D'APPLICATION
3 400 K. La source sensitométrique décrite dans la présente
La présente Norme Internationale fixe les caractéristiques
Norme Internationale est concue pour être utilisée avec le
des sources lumineuses qui conviennent à l'exposition
second type (3 400 K).
des surfaces photosensibles en noir et
sensitométriques
Dans la présente Norme Internationale, les spécifications de
blanc et en couleurs. La distribution spectrale du
distribution spectrale énergétique de l'illuminant
rayonnement d'exposition coïncide étroitement avec la
sensitométrique sont déduites de la distribution spectrale
distribution spectrale énergétique de la lumière d'une lampe
énergétique du corps noir à la température de couleur de
survoltée (flood) moyenne modifiée par la transmission
'L 3 400 K modifiée par la transmittance spectrale d'un
spectrale d'un objectif moyen d'appareil photographique
objectif photographique moyen spécifié au Tableau 3. La
(voir Tableau 3), sauf dans l'infrarouge.
1

---------------------- Page: 3 ----------------------
IS0 2242 -1972 (F)
.-
TABLEAU 2 - Distribution spectrale énergétique relative
2 SOURCE LUMINEUSE
de la lampe flood normalide pour la sensitometriel )
1
Longueur
Energie ;omme dei
d'onde
InergielEnergie totali
relative intervalles
nm
360
2.7
2.1 Spécifications générales
370
6,7
La source lumineuse doit être une lampe telle que le
380 11.3
rayonnement incident sur le plan d'exposition du
390 16.0
sensitomètre ait, avec un filtre absorbant, si nécessaire, la
57.7 5812 871 = 0,020
400 21.0
distribution spectrale indiquée dans le Tableau 2, pour la
lampe flood nor
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.